SCF: Seismicity-Constrained Fault Detection and Characterization
SCF: Seismicity-Constrained Fault Detection and Characterization
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
SCF: Seismicity-Constrained Fault Detection and Characterization
Geological fault detection and characterization are crucial for understanding subsurface dynamics across scales. While methods for fault delineation based on either seismicity location analysis or seismic image reflector discontinuity are well-established, a systematic approach that integrates both data types remains absent. We develop a novel machine learning model that unifies seismic reflector images and seismicity location information to automatically identify geological faults and characterize their geometrical properties. The model encodes a seismic image and a seismicity location image separately, and fuses the encoded features with a spatial-channel attention fusion module to improve the learning of important features in both inputs. We design an automated strategy to generate high-quality synthetic training data and labels. To improve the realism of the seismicity location image, we include random seismicity noise and missing seismicity location associated with some of the faults. We validate the model’s efficacy and accuracy using synthetic data examples and two field data examples. Moreover, we show that fine-tuning the trained model with a small, domain-specific dataset enhances its fidelity for field data applications. The results demonstrate that integrating seismicity location and seismic images into a unified framework allows the end-to-end neural network to achieve higher fidelity and accuracy in delineating subsurface faults and their geometrical properties compared with image-only fault detection methods. Our approach offers an adaptive data-driven tool for geological fault characterization and seismic hazard mitigation, bridging the gap between seismicity location and image-based fault detection methods.
This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.
Site characterization for underground injection and storage of gigatonne-scale CO₂ requires reliable and cost-effective methods to detect and characterize faults and fractures and to assess their stress state and fault activation potential. This is critical, as wastewater injection and disposal have been shown to activate faults and induce earthquakes, and CO₂ leakage remains a key concern for long-term storage. In this project, we developed seismic methods to detect and characterize large-scale sedimentary and crystalline basement faults and associated small-scale fractures below conventional seismic imaging resolution using multicomponent (9C) surface seismic data. Machine learning was used to automatically interpret large-scale faults, providing key information for estimating the maximum magnitude of potential induced earthquakes. High-fidelity imaging was achieved by exploiting redundancy across multiple elastic wave modes, where independent images from different modes and frequencies cross-validate each other. We also used our nonlinear signal comparison (NLSC) method for ground roll removal, improving data quality in complex near-surface conditions. The methods were validated using field data acquired in central Montana. Results show that basement faults extend into the sedimentary section and that small-scale fractures are widespread above the basement. The inferred stress orientation is consistent with regional stress data, and the estimated maximum induced earthquake magnitude is small (Mw ~2.3). The developed workflow provides a practical approach for fault and fracture characterization and for assessing induced seismicity and leakage risk. It is directly applicable to CO₂ storage site selection and to other subsurface systems.
Utilizing spread spectrum time domain reflectometry (SSTDR) to detect, locate, and characterize faults in photovoltaic (PV) systems is examined in this paper. We present a method to obtain the model parameters that are needed to produce digital twin SSTDR responses for PV systems. The digital twin SSTDR responses could be used to predict faults within the PV systems. Here, the model parameters are the reflection and transmission coefficients at each impedance discontinuity in the PV system along with the propagation coefficients across each PV cable segment. We obtain model parameter by applying inverse modeling techniques to experimental SSTDR data associated with PV systems. Our model parameters can be used in any digital twin simulation method for modeling reflectometry in frequency-dependent and complex loads. For validation, we used the model parameters in a graph network simulation engine and adapted it to be used for SSTDR digital twin simulations in PV systems. We produced simulations for 0 to 10 PV modules connected in series. We also simulated SSTDR responses for open circuit disconnections in a PV setup containing 10 PV modules in series. Results show that all but one simulated disconnect locations match experimental disconnection locations of the same setup with an error of less than 5%.
Accurate characterization of subsurface geophysical properties and detection of the fault system are essential for geothermal energy exploration and production. The Soda Lake geothermal field is in western Nevada with a complex fault system. Previous seismic characterization only produced a low-resolution, smooth velocity model along with a simple, conceptual fault model. Using optimized correlation-based full-waveform inversion, wavefield-separation-based reverse-time migration, and automatic fault detection techniques, we present 3D seismic characterization for the Soda Lake geothermal field using 3D surface seismic data acquired with Vibroseis sources. Here, we obtain 3D high-resolution velocity, density, and acoustic impedance models, 3D seismic images with different grid spacings, and a high-resolution fault system. Consistency check between the constructed faults and currently active injection and production geothermal wells verifies that our seismic inversion and imaging results and detected faults are reliable. These results can provide valuable information for optimizing well placement and geothermal energy production at the Soda Lake geothermal field.
Geologic storage of carbon dioxide can efficiently contribute to reduce greenhouse gas emissions to the atmosphere. Two major hazards of this technology are leakage towards the ground surface and fluid-induced seismicity. While major faults may be detected and avoided during site characterization, undetected subseismic faults could be encountered once injection has started. This paper investigates leakage and reactivation of undetected faults through coupled thermal–hydraulic–mechanical modeling. The simulations are performed using a recently developed sequential simulator, TOUGH-Pylith, that allows to accurately account for the thermodynamics of brine-CO 2 injection mixtures, and to model faults as surfaces of discontinuity using state-of-the-art fault friction laws. The simulator is benchmarked against well-known analytical solutions and subsequently applied to investigate two cases of CO 2 injection injection close to undetected faults under normal and strike-slip faulting regimes. Furthermore, although the scenarios are generic and represent unfavorable conditions, they suggest that leakage could occur and that undetected faults could trigger minor seismic events. Therefore, careful site characterization and continuous monitoring during operations should be always performed.
As the photovoltaics (PV) industry grows in sophistication, so must the extent to which systems are characterized. UV Fluorescence (UVF) imaging is a valuable, easy-to-perform, high-throughput, nonintrusive technique for characterizing modules in the field and in the lab. However, UVF is still a relatively new technique, and many in the PV industry are still unaware of its potential. We provide a guideline for obtaining, processing, and interpreting UVF images. We have provided a list of considerations for imaging hardware and settings, a suggested pipeline for image processing, and details on a survey of features shown in UVF images. As a result, a new database with UVF images of 7190 modules and another database curated by BrightSpot Automation are publicly available.
Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.
This project directly supports the Geothermal Technologies Office (GTO) objectives outlined in the Multi-Year Program Plan (MYPP) by advancing two key research areas: “Exploration and Characterization” and “Data, Modeling, and Analysis.” This project has successfully demonstrated a pre-drilling ability to image and characterize the distribution and connectivity of subsurface faults and fractures, key parameters for identifying permeable pathways that enable geothermal fluids to circulate and produce energy. Specifically, we developed and implemented innovative machine learning methodologies to enhance geothermal exploration. Large-scale faults were detected using a Convolutional Neural Network (CNN), while small-scale fractures were characterized using a novel Double-Beam Neural Network (DBNN). These tools have proven both technically effective and cost-efficient by reducing reliance on expensive exploratory drilling. Through collaboration with our geothermal industry partner, this research has significantly advanced techniques for identifying hidden geothermal systems and extending the productive lifespan of existing geothermal fields. We applied our methods to two geothermal fields—Soda Lake (Nevada) and Lightning Dock (New Mexico)—to identify shallow steam-charged fracture zones and characterize deep faults at depths of 1.5-2 km. The steam zone identified at the Soda Lake geothermal field showed excellent agreement with prior drilling data, validating the effectiveness of our approaches. In addition, the analysis revealed three new prospective drilling targets for further development and verification. The outcomes of this project improve our scientific understanding of geothermal reservoir behavior, enhance exploration efficiency, extend the economic life of existing geothermal plants. Ultimately, these advancements contribute to GTO’s goal of achieving more sustainable, affordable, and data-driven geothermal energy development across the United States.
The exploration of topologically-ordered states of matter is a long-standing goal at the interface of several subfields of the physical sciences. Such states feature intriguing physical properties such as long-range entanglement, emergent gauge fields and non-local correlations, and can aid in realization of scalable fault-tolerant quantum computation. However, these same features also make creation, detection, and characterization of topologically-ordered states particularly challenging. Motivated by recent experimental demonstrations, we introduce a paradigm for quantifying topological states—locally error-corrected decoration (LED)—by combining methods of error correction with ideas of renormalization-group flow. Our approach allows for efficient and robust identification of topological order, and is applicable in the presence of incoherent noise sources, making it particularly suitable for realistic experiments. We demonstrate the power of LED using numerical simulations of the toric code under a variety of perturbations. We subsequently apply it to an experimental realization, providing new insights into a quantum spin liquid created on a Rydberg-atom simulator. Finally, we extend LED to generic topological phases, including those with non-abelian order.
Subsurface characterization is crucial for geothermal energy exploration and production. Yet hydrothermal reservoirs usually reside in highly fractured and faulted zones where accurate characterization is very challenging because of low signal-to-noise ratios of land seismic data and lack of coherent reflection signals. We perform an active-source seismic characterization for the Blue Mountain geothermal field in Nevada using active seismic data to reveal the elastic medium property complexity and fault distribution at this field. We first employ an unsupervised machine learning method to attenuate groundroll and near-surface guided-wave noise and enhance coherent reflection and scattering signals from noisy seismic data. We then build a smooth initial P-wave velocity model based on an existing magnetotellurics survey result, and use 3D first-arrival traveltime tomography to refine the initial velocity model. We then derive a set of elastic wave velocities and anisotropic parameters using elastic full-waveform inversion, and obtain PP and PS images using elastic reverse-time migration. We identify major faults by analyzing the variations of seismic velocities and anisotropy parameters, and reveal mid- to small-scale faults by applying a supervised machine learning method to the seismic migration images. Our characterization reveals complex velocity heterogeneities and anisotropies, as well as faults, with a high spatial resolution. These results can provide valuable information for optimal placement of future injection and production wells to increase geothermal energy production at the Blue Mountain geothermal power plant.
This is the final technical report for the DOE-funded Panorama 360 project. Panorama 360 provided a resource for the collection, analysis, and sharing of performance data about end-to-end scientific workflows executing on DOE facilities. The work focused on workflows that include experimental data generation at DOE facilities. The main activities of Panorama 360 include the development of: 1. A distributed repository that stores different types of workflow execution data (e.g., point and time series performance traces at fine- and coarse-grained levels); 2. A set of open-source data capture, curation, and publishing tools fully integrated with a state-of-the-art workflow management system that automates data ingestion to the repository and enables users to discover, query, and process data from the repository; 3. A set of analysis algorithms and machine learning based tools to perform analysis and characterization of the gathered data, which can be used to detect anomalous performance or system faults; and 4. Best practices and recommendations for workflow evaluation, analysis, execution, and architectures.
This final technical report from the lead institution, USC grant #DE-SC0012636, serves as the final technical report for collaborative institution UNC-CH grant #DE-SC0012390. The goal was to develop a repository and associated capabilities for data collection, ingestion, and analysis for a broad class of DOE applications that span experimental and simulation science workflows. In particular, this work focuses on workflows that include experimental data generation at DOE facilities. The main activities of Panorama 360 include the development of: (1) A distributed repository that stores different types of workflow execution data (e.g., point and time series performance traces at fine- and coarse-grained levels); (2) A set of open-source data capture, curation, and publishing tools fully integrated with a state-of-the-art workflow management system that automates data ingestion to the repository and enables users to discover, query, and process data from the repository; (3) A set of analysis algorithms and machine learning based tools to perform analysis and characterization of the gathered data, which can be used to detect anomalous performance or system faults; and (4) Best practices and recommendations for workflow evaluation, analysis, execution, and architectures.
In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.
Abstract We discuss data of three laboratory stick‐slip experiments on Westerly Granite samples performed at elevated confining pressure and constant displacement rate on rough fracture surfaces. The experiments produced complex slip patterns including fast and slow ruptures with large and small fault slips, as well as failure events on the fault surface producing acoustic emission bursts without externally‐detectable stress drop. Preparatory processes leading to large slips were tracked with an ensemble of ten seismo‐mechanical and statistical parameters characterizing local and global damage and stress evolution, localization and clustering processes, as well as event interactions. We decompose complex spatio‐temporal trends in the lab‐quake characteristics and identify persistent effects of evolving fault roughness and damage at different length scales, and local stress evolution approaching large events. The observed trends highlight labquake localization processes on different spatial and temporal scales. The preparatory process of large slip events includes smaller events marked by confined bursts of acoustic emission activity that collectively prepare the fault surface for a system‐wide failure by conditioning the large‐scale stress field. Our results are consistent overall with an evolving process of intermittent criticality leading to large failure events, and may contribute to improved forecasting of large natural earthquakes.
Memory, used by a computer to store data, is generally prone to faults, including permanent faults (i.e. relating to a lifetime of the memory hardware), and also transient faults (i.e. relating to some external cause) which are otherwise known as soft errors. Since soft errors can change the state of the data in the memory and thus cause errors in applications reading and processing the data, there is a desire to characterize the degree of vulnerability of the memory to soft errors. In particular, once the vulnerability for a particular memory to soft errors has been characterized, cost/reliability trade-offs can be determined, or soft error detection mechanisms (e.g. parity) may be selectively employed for the memory. In some cases, memory faults can be diagnosed by redundant execution and a diagnostic coverage may be determined.