Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fast counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Normally Expected Aberrations in the 8-hour Dynamic EKG

The establishment of norms for interpreting long term dynamic electrocardiograms is attempted by correlating a completely disease symptom and cardiac risk factor free sample with a non-pure sample in the direction of normality on various variables. Out of a population of 362 subjects exposed to dynamic electrocardiogram testing, a discrimination between normals and abnormals in terms of traditional risk factors was observed. The two groups differed significantly on the following variables: cholesterol, smoking, systolic blood pressure, white blood count, fasting blood sugar, uric acid, resting EKG, year of birth, and coronary insufficiency.

Fleck, R. L.↗

Fast Vehicle Turning-Movement Counting using Localization-based Tracking

Despite the high utility of traffic volume and turning movement data, such data is still hard to come by for the vast majority of roadways and intersections in nearly ev- ery city. Edge computing devices offer a promising tool for recording turning movement data if lightweight algorithms can be designed to run in real-time with relatively modest computational complexity. To that end, this work presents Vehicle Turning-Movement Counting using Localization- based Tracking (LBT-Count). This method is fast because it never performs detection on a full frame. Instead, only a few portions of the image are cropped and used to de- tect objects within the frame. The method achieves com- petitive performance on the public evaluation server for Track 1 of the AI City Challenge (7th overall on the first 50% of data). Furthermore, we show that LBT-Count is 52% faster than an analogous counting algorithm utilizing a traditional tracking-by-detection framework on available challenge data.

42 ENGINEERING↗

Fast correlation function calculator: A high-performance pair-counting toolkit

A novel high-performance exact pair-counting toolkit called fast correlation function calculator (FCFC) is presented. With the rapid growth of modern cosmological datasets, the evaluation of correlation functions with observational and simulation catalogues has become a challenge. High-efficiency pair-counting codes are thus in great demand. We introduce different data structures and algorithms that can be used for pair-counting problems, and perform comprehensive benchmarks to identify the most efficient algorithms for real-world cosmological applications. We then describe the three levels of parallelisms used by FCFC, SIMD, OpenMP, and MPI, and run extensive tests to investigate the scalabilities. Finally, we compare the efficiency of FCFC with alternative pair-counting codes. The data structures and histogram update algorithms implemented in FCFC are shown to outperform alternative methods. FCFC does not benefit greatly from SIMD because the bottleneck of our histogram update algorithm is mainly cache latency. Nevertheless, the efficiency of FCFC scales well with the numbers of OpenMP threads and MPI processes, even though speedups may be degraded with over a few thousand threads in total. FCFC is found to be faster than most (if not all) other public pair-counting codes for modern cosmological pair-counting applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast event-based electron counting for small-molecule structure determination by MicroED

Electron counting helped realize the resolution revolution in single-particle cryoEM and is now accelerating the determination of MicroED structures. Its advantages are best demonstrated by new direct electron detectors capable of fast (kilohertz) event-based electron counting (EBEC). This strategy minimizes the inaccuracies introduced by coincidence loss (CL) and promises rapid determination of accurate structures. We used the Direct Electron Apollo camera to leverage EBEC technology for MicroED data collection. Given its ability to count single electrons, the Apollo collects high-quality MicroED data from organic small-molecule crystals illuminated with incident electron beam flux densities as low as 0.01–0.045 e − /Å 2 /s. Under even the lowest flux density (0.01 e − /Å 2 /s) condition, fast EBEC data produced ab initio structures of a salen ligand (268 Da) and biotin (244 Da). Each structure was determined from a 100° wedge of data collected from a single crystal in as few as 50 s, with a delivered fluence of only ∼0.5 e − /Å 2 . Fast EBEC data collected with a fluence of 2.25 or 3.33 e − /Å 2 also facilitated a 1.5 Å structure of thiostrepton (1665 Da). While refinement of these structures appeared unaffected by CL, a CL adjustment applied to EBEC data further improved the distribution of intensities measured from the salen ligand and biotin crystals. However, CL adjustment only marginally improved the refinement of their corresponding structures, signaling the already high counting accuracy of detectors with counting rates in the kilohertz range. Overall, by delivering low-dose structure-worthy data, fast EBEC collection strategies open new possibilities for high-throughput MicroED.

EBEC↗

Performance of a Space-Based Wavelet Compressor for Plasma Count Data on the MMS Fast Plasma Investigation

Data compression has been a staple of imaging instruments for years. Recently, plasma measurements have utilized compression with relatively low compression ratios. The Fast Plasma Investigation (FPI) on board the Magnetospheric Multiscale (MMS) mission generates data roughly 100 times faster than previous plasma instruments, requiring a higher compression ratio to fit within the telemetry allocation. This study investigates the performance of a space-based compression standard employing a Discrete Wavelet Transform and a Bit Plane Encoder (DWT/BPE) in compressing FPI plasma count data. Data from the first 6 months of FPI operation are analyzed to explore the error modes evident in the data and how to adapt to them. While approximately half of the Dual Electron Spectrometer (DES) maps had some level of loss, it was found that there is little effect on the plasma moments and that errors present in individual sky maps are typically minor. The majority of Dual Ion Spectrometer burst sky maps compressed in a lossless fashion, with no error introduced during compression. Because of induced compression error, the size limit for DES burst images has been increased for Phase 1B. Additionally, it was found that the floating point compression mode yielded better results when images have significant compression error, leading to floating point mode being used for the fast survey mode of operation for Phase 1B. Despite the suggested tweaks, it was found that wavelet-based compression, and a DWT/BPE algorithm in particular, is highly suitable to data compression for plasma measurement instruments and can be recommended for future missions.

plasma↗

Time-stamping and counting of single photons using fast camera

I will discuss fast optical cameras based on the back-illuminated silicon sensor and Timepix3 ASIC. The sensor has high quantum efficiency, and the chip provides nanosecond scale time resolution and data-driven readout with 80Mpix/sec bandwidth. The intensified version of the camera is single photon sensitive and since recently has been used for registration of single photons in a variety of quantum information science and quantum imaging experiments as well as for other applications. We briefly review the camera and describe recent experiments with a Hong-Ou-Mandel interferometer to characterize its photon counting capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration and Concept of Operations for a Zero-Knowledge Protocol Passive Imaging Measurement for Arms Control

Here, we present an imaging system that employs zero-knowledge protocols to protect sensitive geometrical information, along with procedures to increase confidence in the result. The goal of this work is to enable the inclusion of warhead confirmation measurements in future arms control treaties. We present a demonstration of both true positive and true negative measurements that validate models and establish authenticating procedures toward meeting acceptance requirements for use in nuclear facilities. We use a two-dimensional time-encoded fast neutron imaging system with an anti-symmetric mask pattern; the fast neutron count values exceeding minimum or maximum thresholds indicate that two measured items are not identical. Laboratory measurements over twenty trials show that alarm rates for negative confirmation measurements are within uncertainties of model predictions. Positive confirmation measurements indicate that alarm rates are large enough to encourage treaty compliance.

Sweany, Melinda Dominique [Sandia National Laborat↗

Geochemical Mapping of 4 Vesta Begins

By December, the NASA Dawn spacecraft will have descended to a low altitude mapping orbit (LAMO), where the Gamma Ray and Neutron Detector (GRaND) will acquire global mapping data for up to four months. Measurements by GRaND will help answer elusive questions about how Vesta differentiated and the nature of processes that shaped Vesta s surface. The data will be analyzed to determine the abundances of Mg, Si, Fe, K, Th, and H at a spatial resolution of roughly 300 km full-width-at-half-maximum from a 465 km radius orbit. Thermal and fast neutron counting data will be analyzed to determine the neutron macroscopic absorption cross section and average atomic mass, providing constraints on additional elements, such as Ca and Al. GRaND will quantify the elemental composition of coarse spatial units identified by Dawn s Framing Camera (FC) and the Visible & Infrared Spectrometer (VIR). In addition, GRaND will map the mixing ratio of compositional end members selected from the howardite, eucrite and diogenite (HED) meteorites, determine the relative proportions of plagioclase and mafic minerals, and search for compositions that are absent or under-represented in the meteorite collection. While it is generally thought that Vesta s crust on a regional scale should be well-represented by linear mixing of HED whole-rock compositions, there are hints that Vesta may be more diverse than implied by this model. For example, the discovery of K-rich impact glasses in howardites suggests that K-rich rocks may be present on a portion of Vesta s surface, and the analysis of diogenites indicates considerable variability in the magmatic processes that formed them. The chemical composition of materials within Vesta s south polar structure may provide further clues to how it formed. An impact might have exposed mantle and lower crustal materials, which should have a distinctive compositional signature. We present the analysis of data acquired by GRaND from cruise through the descent to LAMO, including GRaND s sensitivity to different elements and geochemical processes.

Prettyman, Thomas H.↗

Performance of a Discrete Wavelet Transform for Compressing Plasma Count Data and its Application to the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

Plasma measurements in space are becoming increasingly faster, higher resolution, and distributed over multiple instruments. As raw data generation rates can exceed available data transfer bandwidth, data compression is becoming a critical design component. Data compression has been a staple of imaging instruments for years, but only recently have plasma measurement designers become interested in high performance data compression. Missions will often use a simple lossless compression technique yielding compression ratios of approximately 2:1, however future missions may require compression ratios upwards of 10:1. This study aims to explore how a Discrete Wavelet Transform combined with a Bit Plane Encoder (DWT/BPE), implemented via a CCSDS standard, can be used effectively to compress count information common to plasma measurements to high compression ratios while maintaining little or no compression error. The compression ASIC used for the Fast Plasma Investigation (FPI) on board the Magnetospheric Multiscale mission (MMS) is used for this study. Plasma count data from multiple sources is examined: resampled data from previous missions, randomly generated data from distribution functions, and simulations of expected regimes. These are run through the compression routines with various parameters to yield the greatest possible compression ratio while maintaining little or no error, the latter indicates that fully lossless compression is obtained. Finally, recommendations are made for future missions as to what can be achieved when compressing plasma count data and how best to do so.

Particles↗

Improved light yield and growth of large-volume ultrafast single crystal scintillators Cs 2 ZnCl 4 and Cs 3 ZnCl 5

Due to their reported fast decay times, Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are promising candidates for detection of gamma rays and X-rays in high count rate and fast timing applications. In this work, we show that single crystals with better optical quality than previously demonstrated – and larger in size – can be grown via the vertical Bridgman method. Highly transparent Ø7 mm crystals of undoped Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are grown and measured to have light yields surpassing those previously reported, achieving 1980 ± 100 ph/MeV and 1460 ± 70 ph/MeV at 662 keV – a 55% and 232% improvement, respectively. We observe single-component scintillation decay times for both Cs 2 ZnCl 4 (1.66 ns) and Cs 3 ZnCl 5 (0.82 ns) and radioluminescence emission with maximum intensity at ~290 nm. Scalability of these materials is also evaluated based on growth of Ø22 mm crystals. Minimal cracking is observed, and the fast decay times are maintained at this size. Coincidence time resolution of 3 × 3 × 5 mm 3 and 7 × 7 × 10 mm 3 pixels cut from Ø22 mm Cs 2 ZnCl 4 are measured to be 148 ± 1 ps FWHM and 175 ± 1 ps FWHM, respectively. Here, the improved performance and ability to be fabricated in large sizes now place Cs 2 ZnCl 4 and Cs 3 ZnCl 5 on the map as potential contenders for radiation detection applications where BaF 2 – the most commonly used ultrafast inorganic scintillator – is typically considered.

36 MATERIALS SCIENCE↗

Mars: Detaching of the Free Water Signature (FWS) Presence Regions on the Base of HEND/ODYSSEY Data and Their Correlation with Some Permafrost Features from MOC Data

The first results from global mapping of the neutron albedo from Mars by HEND instrument have shown the noticeable deficit of both the epithermal (EN) and the fast (FN) neutrons counts rate in the high latitudes regions of both hemispheres of the planet. The deficit is indicative for high enriching of the surface regolith by hydrogen, which may correspond to amount of any water phases and forms. The objectives of our study are the spatial and temporal variations of the free water (ice) signature in the Martian surface layer on the base of HEND/ODYSSEY data and their correlation with spatial spreading of some permafrost features, mapped on the base of MOC images. For the study we used the results of the global mapping (pixel 5 x5 ) of EN and FN albedo, realized by HEND/ODYSSEY in the period from 17 February to 10 December 2002 year.

Kuzmin, R. O.↗

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

47 OTHER INSTRUMENTATION↗

Single photon detection and sub-nanosecond timing resolution with RCA C31034 photomultiplier

The very high quantum efficiencies and low dark count rates achieved with selected RCA C31034 photomultipliers make them attractive candidates for single photoelectron fast timing experiments. Single photoelectron plateau counting and a timing resolution of 0.60 nsec (FWHM) were obtained using fast amplifiers, constant fraction timing discriminators, and a pulsed light emitting diode. A redesign of the C31034 incorporating features of the very fast C31024 is suggested to yield even better timing resolution.

Reisse, R.↗

Report on Task USA A 0931 (A.252) Implementation of Fast, Front-End Electronics for Improved Low-Dead Time Neutron Counting

The International Atomic Energy Agency's (IAEA) Department of Safeguards is working on the elaboration and implementation of advanced Non-Destructive Assay (NDA) methods, generally known as neutron noise analysis, for the verification of critical and sub-critical cores containing substantial quantities of direct use nuclear material. These verification methods rely on interpreting time properties of the neutron multiplication process, which are to be extracted from measured neutron pulse trains. The interpretations are highly dependent on the quality of the measured data, which is directly related to the capability of an employed neutron detector to resolve very close detection events originating from neutron bursts produced in a highly multiplying medium. Therefore, the application of detectors with minimum dead-time, pile-up, and other distortion effects is required. This report describes the work under Task USA A 0931 (A.252 Implementation of fast, front-end electronics for improved low-dead time neutron counting).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accounting for electron-beam-induced warping of molecular nanocrystals in MicroED structure determination

High-energy electrons induce sample damage and motion at the nanoscale to fundamentally limit the determination of molecular structures by electron diffraction. Using a fast event-based electron counting (EBEC) detector, we characterize beam-induced, dynamic, molecular crystal lattice reorientations (BIRs). These changes are sufficiently large to bring reciprocal lattice points entirely in or out of intersection with the sphere of reflection, occur as early events in the decay of diffracted signal due to radiolytic damage, and coincide with beam-induced migrations of crystal bend contours within the same fluence regime and at the same illuminated location on a crystal. These effects are observed in crystals of biotin, a series of amino acid metal chelates, and a six-residue peptide, suggesting that incident electrons inevitably warp molecular lattices. The precise orientation changes experienced by a given microcrystal are unpredictable but are measurable by indexing individual diffraction patterns during beam-induced decay. Reorientations can often tilt a crystal lattice several degrees away from its initial position before irradiation, and for an especially beam-sensitive Zn(II)-methionine chelate, are associated with dramatic crystal quakes prior to 1 e − Å −2 electron beam fluence accumulates. Since BIR coincides with the early stages of beam-induced damage, it echoes the beam-induced motion observed in single-particle cryoEM. As with motion correction for cryoEM imaging experiments, accounting for BIR-induced errors during data processing could improve the accuracy of MicroED data.

Vlahakis, Niko (ORCID:0000000250920265)↗

Low-Altitude Reconnection Inflow-Outflow Observations During a 2010 November 3 Solar Eruption

For a solar flare occurring on 2010 November 3, we present observations us- ing several SDO/AIA extreme-ultraviolet (EUV) passbands of an erupting flux rope followed by inflows sweeping into a current sheet region. The inflows are soon followed by outflows appearing to originate from near the termination point of the inflowing motion an observation in line with standard magnetic reconnection models. We measure average inflow plane-of-sky speeds to range from approximately 150 - 690 km s-1 with the initial, high-temperature inflows being the fastest. Using the inflow speeds and a range of Alfven speeds, we estimate the Alfvenic Mach number which appears to decrease with time. We also provide inflow and outflow times with respect to RHESSI count rates and find that the fast, high- temperature inflows occur simultaneously with a peak in the RHESSI thermal light curve. Five candidate inflow-outflow pairs are identified with no more than a minute delay between detections. The inflow speeds of these pairs are measured to be approximately 10(exp 2) km s-1 with outflow speeds ranging from approximately 10(exp 2) - 10(exp 33 km s-1 indicating acceleration during the reconnection process. The fastest of these outflows are in the form of apparently traveling density enhancements along the legs of the loops rather than the loop apexes themselves. These flows could possibly either be accelerated plasma, shocks, or waves prompted by reconnection. The measurements presented here show an order of magnitude difference between the retraction speeds of the loops and the speed of the density enhancements within the loops presumably exiting the reconnection site.

Savage, Sabrina L.a↗