Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Facility for Rare Isotope Beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heavy ion beam physics at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) will be the world's premier rare-isotope beam facility. Experiments with the majority (~80%) of the isotope predicted to exist will become available. The FRIB facility is based on a superconducting (SC) heavy ion linac with output energy above 200 MeV/u for any ions at beam power of 400 kW. FRIB includes a target facility for in-flight production of rare isotopes. A three-stage fragment separator will be used to prepare fast rare isotope beams with high-purity for nuclear physics experiments. The installation work of the accelerator and experimental systems is approaching completion and multi-stage beam commissioning activities started in summer 2017 with expected project completion in early 2022. In conclusion, the commencement of operation for users' experiments is planned immediately following the project completion.

43 PARTICLE ACCELERATORS↗

Acceleration of uranium beam to record power of 10.4 kW and observation of new isotopes at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) is a major nuclear physics facility for research with fast, stopped, and reaccelerated beams that was successfully commissioned in May 2022. A key capability of FRIB is the production of an acceleration of the uranium beam, but this capability requires the facility to work at the design limits of the lowest charge-to-mass ratio and the highest power density on the beam intercepting devices. This paper presents techniques for overcoming the significant challenges in accelerating the uranium beam, culminating in the demonstration of 10.4 kW on target, and the discovery of three new isotopes. The high-power uranium beam enabled us to produce and identify G 88 a , A 93 s , and S 96 e , within the first 24 h of operation. The successful uranium operation at FRIB sets a new record for accelerated uranium beam power above 10 kW and opens a new avenue of research with rare isotopes. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Commissioning Status of the Linac for the Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams will be completed in late 2021. Here, we report here on the current efforts to commission the first stages of the 200-MeV/u superconducting, continuous wave heavy-ion linac. The statuses of the cryogenic plant and its distribution system, the accelerator cryomodule commissioning and operations, the ion source and front end transport development, the radio-frequency quadrupole commissioning, and then beam dynamics development to support high-power operation are reviewed. Plans for commissioning the remainder of the linac systems are presented.

43 PARTICLE ACCELERATORS↗

Considerations on the design of a rare isotope beam facility based on superconducting heavy ion linacs

To establish an accelerator facility based on superconducting linear accelerator (linac) for nuclear and applied sciences in Korea, the rare isotope science project started in December 2011 under the auspices of the Institute for Basic Science (IBS). The layout of the facility has been mostly frozen since 2013 and civil construction began in 2016. On the other hand, an alternative linac design option was recently investigated in collaboration with the linac development group of Argonne National Lab in search of a further optimized configuration. A new linac lattice was developed and evaluated against realistic machine errors using TRACK. The beam optics simulations and error analysis then proved the soundness of this alternative design. In addition, beam optics of the injector was studied for simultaneous acceleration of both stable and rare isotope beams with the use of an electron beam ion source (EBIS). Additionally considered are alternative options of high-power cyclotrons as ISOL driver in order to enhance the capability of rare isotope beam production and fully exploit the superconducting linac facility built at high cost.

07 ISOTOPE AND RADIATION SOURCES↗

Gas stopping and reacceleration techniques at the Facility for Rare Isotope Beams (FRIB)

The Facility for Rare Isotope Beams (FRIB) at Michigan State University provides a wide range of beams and energies for science with fast, stopped and reaccelerated rare-isotope beams. FRIB was commissioned in 2022 with the science program beginning in May 2022. Here, the combination of fast beams followed by gas stopping of rare-isotope beams together with reacceleration is unique to FRIB. Stopping techniques and beam manipulation at very-low energies are important to slow down fast beams for use in either stopped-beam experimental devices, or subsequent injection in the reaccelerator for experiments at energies ranging from 0.3 MeV/u to 12 MeV/u, depending on the Q/A of the ion. Innovative stopped-beam techniques to optimize the stopping and extraction efficiencies across a wide range of atomic numbers, as well as to reduce contamination and increase extraction speed, were developed. Reacceleration of those beams involve cooling, bunching, charge breeding and acceleration by a state-of-the-art superconducting reaccelerator, ReA. In this contribution we present the latest results of various gas stoppers and techniques to eliminate contaminants after reacceleration by the ReA.

43 PARTICLE ACCELERATORS↗

Twentieth Exotic Beam Summer School (EBSS2023)

The study of unstable nuclei with unusual ratios of protons to neutrons is one of the frontiers of science. Investigating these rare isotopes is critical for understanding the synthesis of the chemical elements in stellar explosions as well as the fundamental nature of the nuclear forces that bind atomic nuclei together. Scientific progress in this field is driven by the development of exotic beams in present and next-generation rare-isotope beam facilities including the Facility for Rare Isotope Beams (FRIB). Nuclear physics is a broad discipline, influencing our knowledge on subjects as diverse as weakly-bound nuclei, many-body quantum theory, the super heavy elements, and the inner structure of neutron stars. Applications based on nuclear science and technologies include medical diagnostics and therapies, materials science, and national security. The major goal achieved in this project was to hold Exotic Beam Summer School 2023 (EBSS2023), the twentieth installment of EBSS series, July 9-15, 2023 at the Facility for Rare Isotope Beams on the campus of Michigan State University to educate and train the next generation of scientists that will drive research with rare-isotope beams. FRIB became operational in 2022 and is now providing beams of exotic nuclei that will ramp up to unmatched intensities, exceeding what is available today by orders of magnitude. Beams available at FRIB are facilitating a wide variety of studies in nuclear structure, astrophysics, fundamental symmetries and societal applications. There is a large community of scientists interested in working with rare isotope beams; for example, the FRIB User Organization currently has over 1,700 members. In order to maximize the scientific output of FRIB, there must be a workforce continuously trained in both the physics of exotic beams and in the practical techniques of carrying out an experiment. This summer school series is designed to specifically address this need - to ensure that new generations of scientists from a broad range of institutions and backgrounds is trained, motivated, and equipped to push the field forward to new and important breakthroughs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Customized Bayesian optimization for efficient beam tuning at the facility for rare isotope beams

Bayesian optimization (BO) has recently emerged as a powerful approach for on-line beam tuning, and it is rapidly gaining adoption across accelerator facilities due to its flexibility and efficiency in handling complex optimization tasks. At the Facility for Rare Isotope Beams, rapid and reliable tuning is essential to support the delivery of diverse ion species. To improve the practicality of BO in this setting, we implemented several enhancements, including scalarized composite objective construction for multicriteria optimization, asynchronous evaluation for better resource utilization, prior-mean-assisted optimization to accelerate convergence, and a local search strategy for rapid completion of the task. We present the details of these methods, discuss challenges-encountered, and share our experience applying them to specific beam-tuning tasks.

Accelerators & storage rings↗

Quantification and purification of isotopic contamination at the ReAccelerator of the Facility for Rare Isotope Beams

At the ReAccelerator within the Facility for Rare Isotope Beams, a combination of an interchangeable aluminum foil and a silicon detector was developed to quantify isobaric contamination in rare isotope beams. The device is simple to operate and is now used routinely. In this article, we describe the system and show an application of the device to determine the level of contamination of an Si-32 rare isotope beam by stable S-32. In addition, we describe how the new diagnostic device helped confirm an enhancement of the beam purity prior to beam delivery to experiments.

Instruments & Instrumentation↗

Accelerator commissioning and rare isotope identification at the Facility for Rare Isotope Beams

In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.

07 ISOTOPE AND RADIATION SOURCES↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

Optical potentials for the rare-isotope beam era

Abstract We review recent progress and motivate the need for further developments in nuclear optical potentials that are widely used in the theoretical analysis of nucleon elastic scattering and reaction cross sections. In regions of the nuclear chart away from stability, which represent a frontier in nuclear science over the coming decade and which will be probed at new rare-isotope beam facilities worldwide, there is a targeted need to quantify and reduce theoretical reaction model uncertainties, especially with respect to nuclear optical potentials. We first describe the primary physics motivations for an improved description of nuclear reactions involving short-lived isotopes, focusing on its benefits for fundamental science discoveries and applications to medicine, energy, and security. We then outline the various methods in use today to build optical potentials starting from phenomenological, microscopic, and ab initio methods, highlighting in particular, the strengths and weaknesses of each approach. We then discuss publicly-available tools and resources facilitating the propagation of recent progresses in the field to practitioners. Finally, we provide a set of open challenges and recommendations for the field to advance the fundamental science goals of nuclear reaction studies in the rare-isotope beam era. This paper is the outcome of the Facility for Rare Isotope Beams Theory Alliance (FRIB-TA) topical program ‘Optical Potentials in Nuclear Physics’ held in March 2022 at FRIB. Its content is non-exhaustive, was chosen by the participants and reflects their efforts related to optical potentials.

42 ENGINEERING↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

First plasma processing trial of a quarter-wave resonator cryomodule at the Facility for Rare Isotope Beams

Studies of plasma processing for reduction of field emission in quarter-wave resonator (QWR) cryomodules are underway at the Facility for Rare Isotope Beams (FRIB), where a total of 104 QWRs are presently in operation. Driving the plasma with a higher-order mode allows for less mismatch at the fundamental power coupler and higher plasma density. The first plasma processing trial for FRIB QWRs in a cryomodule was conducted in January 2024. In-bunker cold tests of the cryomodule showed a significant reduction in field emission x-rays after plasma processing.

Glow & corona plasma discharges↗

Facility for Rare Isotope Beams (FRIB) (Final Technical Report)

This is the final technical report for cooperative agreement DE-SC0000661, between the Department of Energy Office of Science and Michigan State University, for the design and establishment of the Facility for Rare Isotope Beams, its transition to operations and early operations, and the effort to plan and design the High Rigidity Spectrometer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress towards 28 GHz operations at the Facility for Rare Isotope Beams (FRIB)

This paper provides an overview on the design, operational parameters as well as recent development and recent performance, of the superconducting electron cyclotron resonance (ECR) ion source at the Facility for Rare Isotope Beams (FRIB). The ion source has been used in support of beam operations since the end of 2022 and was designed to operate at 28 GHz and be capable of delivering high intensity uranium beams to help support beam delivery of up to a final beam power of 400 kW. Currently operating at up to 20 kW many primary beams have been developed and routinely used with the superconducting ECR including uranium. Initially operated at 18 GHz, the ion source has now been coupled to a 28 GHz gyrotron and high intensity beams have been demonstrated ahead of the facility planned power ramp up. text with the article abstract. Replace this text with the article abstract.

Machicoane, G. A. [Michigan State University, East↗

First N-Doping and Mid-T Baking of Medium-ß 644 MHz 5-Cell Elliptical Superconducting RF Cavities for Michigan State University’s Facility for Rare Isotope Beams

Two hadron linacs currently under development in the US, the PIP-II linac at Fermi National Accelerator Laboratory (FNAL) and the upgrade for Michigan State University’s Facility For Rare Isotope Beams (FRIB), will employ 650 and 644 MHz ß-0.6 elliptical superconducting cavities respectively to meet their design energy requirements. The desired CW operation modes of these two linacs sets Q-factor requirements well above any previously achieved for cavities at this operating frequency and velocity, driving the need to explore new high-Q treatments. The N-doping technique developed at FNAL and employed at an industrial scale to the LCLS-II cryomodules is a strong candidate for high-Q treatments, but work is needed to refine the treatment to the lower operating frequency and velocity regime. We present the first results of the first N-doping tests and a "mid-T" bake test in the FRIB 644 MHz 5-cell elliptical cavities.

43 PARTICLE ACCELERATORS↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗