A multi-channel quench detector is useful for troubleshooting of prototype HTC superconducting magnets with current lead connections and imbedded splices. There are commercially available quench detectors, but not with as many channels, or with the particular functionality of this unit. This unit was designed specifically for cold testing of a superconducting sextupole prototype, which is wound with many turns of HTC ribbon. Associated with the current lead connections and the imbedded splices are 18 voltage taps, thus 17 quench detection channels are required to monitor the condition of the magnet. Of the 20 differential input channels in this quench detection unit, 19 are configured in a ladder network. The 20th channel is isolated and can be connected across any pair of voltage taps. This quench detector is designed to be used to monitor the condition of a series-connected superconducting magnet powered by a unipolar supply, and therefore the polarity and sequence of the voltage taps must be observed. There are 20 toggle switches and 20 red LEDs on the front panel of the unit which are associated with the 20 quench detection channels. There are also 2 green LEDs to indicate the state of the +5 V and +25 V internal supplies. Channel input impedance is ~10 kΩ. The input lines are diode protected against negative voltage transients and can tolerate up to +25 V, which is greater than the compliance of supplies typically used to power superconducting magnets. The front panel switches are used to enable or disable individual channels. If a channel is not used it is disabled. There are 20 pots on the quench detector PCB. They provide adjustment for the sensitivity of each of the 20 channels. There is an onboard reference to facilitate channel sensitivity calibration. The detection sensitivity range is from ~27 mV to ~700 mV. Typically all channels are set for the same sensitivity. The response time is ~20 μs, but the time constant can be increased if desired by adding a single capacitor to each channel. When the magnet under test is cooled to the superconducting state and the supply current to the windings is slowly ramped up to the set point, if there is a voltage rise across a pair of voltage taps which exceeds the quench detection limit of a given channel, then the front panel LED for that channel illuminates and all other channels are disabled within ~25 ns. Thus only the first quench is detected for the channels which are enabled. A pushbutton switch on the front panel is used to reset a quench detection. A 25 pin D-subminiature connector on the back of the unit is used for the channel inputs. TTL level ‘quench’ and ‘quench-not’ signals, and DPDT relay contacts, are provided through a 9 pin D-subminiature connector on the back to indicate a detected quench condition, which could be used to disable the power supply and engage an energy absorber.
47 OTHER INSTRUMENTATION↗