Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRICTION FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Correction to the Stress–Strain Curve During Multistage Hot Deformation of 7150 Aluminum Alloy Using Instantaneous Friction Factors

Multistage stress–strain curve correction based on an instantaneous friction factor was studied for axisymmetric uniaxial hot compression of 7150 aluminum alloy. Experimental friction factors were calculated based on continuous isothermal axisymmetric uniaxial compression tests at various deformation parameters. Then, an instantaneous friction factor equation was fitted by mathematic analysis. After verification by comparing single-pass flow stress correction with traditional average friction factor correction, the instantaneous friction factor equation was applied to correct multistage stress–strain curves. The corrected results were reasonable and validated by multistage relative softening calculations. This research provides a broad potential for implementing axisymmetric uniaxial compression in multistage physical simulations and friction optimization in finite element analysis.

36 MATERIALS SCIENCE↗

Friction-factor characteristics for narrow channels with honeycomb surfaces

The experimental determination of friction-factors for the flow of air in a narrow channel lined with various honeycomb geometries has been carried out. Test results show that, generally, the friction-factor is nearly constant or slightly decreases as the Reynolds number increases, a characteristic common to turbulent flow in pipes. However, in some test geometries this trend is remarkably different. The friction factor dramatically drops and then rises as the Reynolds number increases. This phenomenon can be characterized as a 'friction-factor jump'. Further investigations of the acoustic spectrum and friction-factor measurements for a broad range of Reynolds numbers indicate that the 'friction-factor jump' phenomenon is accompanied by an onset of a normal mode resonance excited coherent flow fluctuation structure, which occurs at Reynolds number of the order of 10,000. The purpose of this paper is to explain the friction-factor-jump phenomenon and friction-factor characteristics.

Ha, T. W.↗

Friction factor data for flat plate tests of smooth and honeycomb surfaces

Friction factors for honeycomb surfaces were measured with a flat plate tester. The flat plate test apparatus was described and a method was discussed for determining the friction factor experimentally. The friction factor model was developed for the flat plate test based on the Fanno Line Flow. The comparisons of the friction factor were plotted for smooth surfaces and six-honeycomb surfaces with three-clearances, 6.9 bar to 17.9 bar range of inlet pressures, and 5,000 to 100,000 range of the Reynolds number. The optimum geometries for the maximum friction factor were found as a function of cell width to cell depth and cell width to clearance ratios.

Ha, Tae Woong↗

Friction-factor data for flat-plate tests of smooth and honeycomb surfaces

Friction factors for honeycomb surfaces were measured with a flat plate tester. The flat plate test apparatus was described and a method was discussed for determining the friction factor experimentally. The friction factor model was developed for the flat plate test based on the Fanno Line Flow. The comparisons of the friction factor were plotted for smooth surfaces and six-honeycomb surfaces with three-clearances, 6.9 bar to 17.9 bar range of inlet pressures, and 5,000 to 100,000 range of the Reynolds number. The optimum geometries for the maximum friction factor were found as a function of cell width to cell depth and cell width to clearance ratios.

Ha, T. W.↗

Experimental studies on heat transfer and friction factor characteristics of forced circulation solar water heater system fitted with helical twisted tapes

Experimental investigation of heat transfer, friction factor and thermal performance of twisted tape solar water heater with various twist ratios has been conducted and the results are compared with plain tube collector for the same operating conditions with Reynolds number varied from 3000 to 23,000. Experimental data from plain tube collector is validated with the fundamental equations and found that the discrepancy is less than {+-}5.35% and {+-}8.80% for Nusselt number and friction factor, respectively. Correlations have been developed for Nusselt number and friction factor with various twist ratios (Y = 3, 4, 5, 6) and are compared with the experimental values. Results conclude that, heat transfer and pressure drop are higher in twisted tape collector compared to the plain one. Among the various twist ratios, the minimum twist ratio 3 is found to enhance the heat transfer and pressure drop due to swirl generation. As the twist ratio increases, the swirl generation decreases and minimizes the heat transfer and friction factor. (author)

14 SOLAR ENERGY↗

Experimental Study on the Effect of Localized Blockages on the Friction Factor of a 61-Pin Wire-Wrapped Bundle

Abstract The thermal-hydraulic behavior of the flow in rod bundles has motivated numerous experimental and computational investigations. Previous studies have identified potential for accumulation of debris within the small subchannels of typical wire-wrapped assemblies with subsequent total or partial blockage of subchannel coolant flow. A test campaign was conducted to study the effects of localized blockages on the bundle averaged friction factor of a tightly packed wire-wrapped rod bundle. Blockages were installed within the bundle, and fluid pressure drop was measured across one wire pitch for a Reynolds number range of 500–17,200. The Darcy–Weisbach friction factor of the perturbed rod bundle geometry was compared with that of the unblocked bundle, as well as with the predictions of a well-established friction factor correlation. Differing effects based on blockage size and location for various flow regimes were studied. A number of conclusions can be made about the effects of the blockages on the friction factor, such as an increasing effect of the blockage on friction factor with an increase in Reynolds number, a change in flow behavior in the turbulent transition flow regime near Reynolds number 3000, differences in effect on friction factor for different types of subchannel blockage, and a nonlinear trend in friction factor variation with flow area impeded for edge subchannels. To this end, all data and quantified uncertainty produced in this study are made available for comparison and validation of advanced computational tools.

Engineering↗

Calculation of Friction Factors in Heat Pipes Using CFD in Support of the Sockeye Code

A heat pipe is two-phase heat transfer device which relies on surface tension and capillary pressure to provide a very efficient heat transfer mechanism. Currently, there is interest in designing micro nuclear power reactors using high temperature heat pipes to provide totally passive cooling. To support this, Sockeye is being developed as a heat pipe simulation capability. To support the development of Sockeye, individual phenomena must be tested. This work focuses on applying a CFD model to evaluate friction factors for use in Sockeye. A CFD model has been developed in Nek5000 which simulates each component fluid, i.e. sodium liquid and vapor, independently and captures the effects of the wick on friction factor. The model tests the effect of the wick permeability and the thickness of the wick occupied by each fluid component. The thickness of the wick occupied by each component can be directly related to the local vapor volume fraction from the Sockeye heat pipe model. Results from the CFD model indicate that friction factor in the liquid flow decreases with increasing wick permeability, while the friction factor in the vapor flow increases with increasing wick permeability. In the liquid, this is likely a direct result of the increased cross sectional area available for the flow. For the vapor, this is explained as the wick acting like a rough wall, while the increased area has only a negligible impact. Results for the tests of the thickness of the wick occupied by each fluid showed a thresholding behavior for both liquid and vapor. When the thickness of the wick occupied by each fluid was increased, it increased the effect of the wick, but only up to a certain point. Once a certain thickness was reached, the friction factors remained constant. When the fluid occupied only a very small fraction of the wick, friction factors returned to nominal values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Entrance and exit region friction factor models for annular seal analysis

The Mach number definition and boundary conditions in Nelson's nominally-centered, annular gas seal analysis are revised. A method is described for determining the wall shear stress characteristics of an annular gas seal experimentally. Two friction factor models are developed for annular seal analysis; one model is based on flat-plate flow theory; the other uses empirical entrance and exit region friction factors. The friction factor predictions of the models are compared to experimental results. Each friction model is used in an annular gas seal analysis. The seal characteristics predicted by the two seal analyses are compared to experimental results and to the predictions of Nelson's analysis. The comparisons are for smooth-rotor seals with smooth and honeycomb stators. The comparisons show that the analysis which uses empirical entrance and exit region shear stress models predicts the static and stability characteristics of annular gas seals better than the other analyses. The analyses predict direct stiffness poorly.

Elrod, David Alan↗

An annular gas seal analysis using empirical entrance and exit region friction factors

Wall shear stress results from stationary-rotor flow tests of five annular gas seals are used to develop entrance and exit region friction factor models. The friction factor models are used in a bulk-flow seal analysis which predicts leakage and rotor-dynamic coefficients. The predictions of the analysis are compared to experimental results and to the predictions of Nelson's analysis (1985). The comparisons are for smooth-rotor seals with smooth and honeycomb-stators. The present analysis predicts the destabilizing cross-coupled stiffness of a seal better than Nelson's analysis. Both analyses predict direct damping well and direct stiffness poorly.

Elrod, D. A.↗

Friction Factor Characterization for High-Porosity Random Fiber Regenerators

NASA Glenn Research Center, the Department of Energy (DOE), and Stirling Technology Company (STC) of Kennewick, Washington are developing a Stirling convertor for a high-efficiency Stirling Radioisotope Power System to provide electric power for NASA Space Science Missions. STC is developing the 55-We Technology Demonstration Convertor (TDC) under contract to DOE. Steady-flow tests were completed to determine the friction factor for the high-porosity regenerators that are used in the TDC. STC fabricated a flow test fixture and three random fiber regenerator test samples, one each at approximately 80, 88, and 96 percent porosities. The flow tests were then completed by the NASA Glenn Flow Calibration Laboratory, and the data reduced to Reynolds number and friction factor. The results showed that the 80 and 88 percent porosity samples had similar characteristics while the 96 percent porosity sample had significantly higher friction factors for given Reynolds numbers compared to the samples with lower porosities. Comparisons were also made between the test data and existing correlations. STC used this data to derive a modified regenerator friction factor correlation for use in the Stirling design code GLIMPS for porosities greater than 88 percent. Using this new correlation, the final optimized regenerator design porosity was reduced from 96 to 90 percent.

Thieme, Lanny G.↗

Convective heat transfer and friction factor characteristics of molten salts in spirally fluted tubes

Spirally fluted tubes have been widely used for heat exchangers due to their superior heat transfer enhancement. However, most of the previous studies focused on the effects of a limited number of geometric parameters, i.e., the flute pitch and flute depth, on convective heat transfer and friction factor characteristics of low-Prandtl-number fluids, i.e., air and water. The correlations developed in these studies may not be accurate or applicable for medium-Prandtl-number fluids, such as molten salts. A numerical analysis using a Computational Fluid Dynamics (CFD) tool, STAR–CCM+, is therefore carried out in this study to systematically investigate the effects of four geometric parameters, including the flute pitch ρ, flute depth e, flute start number N s (or flute helix angle θ), and trough length L tr on convective heat transfer and friction factor characteristics of a medium-Prandtl-number fluid, FLiNaK (46.5LiF-11.5NaF-42KF mol %), in spirally fluted tubes. Additionally, the convective heat transfer and Darcy friction factor correlations are proposed and validated, with ± 20% uncertainties, for medium-Prandtl-number fluids under the following conditions: Re = 88–1600, Pr = 2.5–40, ρ/D c = 0.44–3.51, e/D c = 0.10–0.40, θ/90= 0.20–0.81, and L tr /D c = 0.71–2.16. The correlations proposed help improve the design of spirally fluted-tube heat exchangers.

42 ENGINEERING↗

Experimental studies on heat transfer and friction factor characteristics of Al{sub 2}O{sub 3}/water nanofluid in a circular pipe under laminar flow with wire coil inserts

In this paper, fully developed laminar flow convective heat transfer and friction factor characteristics of Al{sub 2}O{sub 3}/water nanofluid flowing through a uniformly heated horizontal tube with and without wire coil inserts is presented. For this purpose, Al{sub 2}O{sub 3} nanoparticles of 43 nm size were synthesized, characterized and dispersed in distilled water to form stable suspension containing 0.1% volume concentration of nanoparticles. The Nusselt number in the fully developed region were measured and found to increase by 12.24% at Re = 2275 for plain tube with nanofluid compared to distilled water. Two wire coil inserts made of stainless steel with pitch ratios 2 and 3 were used which increased the Nusselt numbers by 15.91% and 21.53% respectively at Re = 2275 with nanofluid compared to distilled water. The better heat transfer performance of nanofluid with wire coil insert is attributed to the effects of dispersion or back-mixing which flattens the temperature distribution and make the temperature gradient between the fluid and wall steeper. The measured pressure loss with the use of nanofluids is almost equal to that of the distilled water. The empirical correlations developed for Nusselt number and friction factor in terms of Reynolds/Peclet number, pitch ratio and volume concentration fits with the experimental data within {+-}15%. (author)

42 ENGINEERING↗

Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs

The use of artificial roughness on the underside of the absorber plate is an effective and economic way to improve the thermal performance of a solar air heater. Several experimental investigations, involving different types of roughness elements, have been carried out to improve the heat transfer from the absorber plate to air flowing in solar air heaters. This paper presents an experimental investigation carried out to study the effect of multiple v-rib roughness on heat transfer coefficient and friction factor in an artificially roughened solar air heater duct. The experiment encompassed Reynolds number (Re) from 2000 to 20000, relative roughness height (e/D) values of 0.019-0.043, relative roughness pitch (P/e) range of 6-12, angle of attack ({alpha}) range of 30-75 and relative roughness width (W/w) range of 1-10. Extensive experimentation has been conducted to collect data on heat transfer and fluid flow characteristics of a rectangular duct roughened with multiple v-ribs. Using these experimental data, correlations for Nusselt number and friction factor in terms of roughness geometry and flow parameters have been developed. (author)

14 SOLAR ENERGY↗

Friction Factor for Flow in Rectangular Ducts with One Side Rib-Roughened

Numerical simulations of incompressible turbulent flow through rectangular ducts with one side rib-roughened were performed to determine pressure drop. The "PHOENICS " software package was used for the computations, which required provision of a wall function for transverse rib-roughened surfaces. The present study was conducted in the range of 10(exp 5) less than or equal to Reynolds number less than or equal to 10(exp 7), 0.01 less than or equal to rib height to hydraulic diameter ratio less than or equal to 0.04, 10 less than or equal to pitch to rib height ratio less than or equal to 40. Using the numerical results, friction factor charts for various aspect ratios were generated. The numerical results agreed well with experimental data that was obtained for 10(exp 5) less than Reynolds less than 2 x 10(exp 5). In addition, a scheme for predicting friction factor using existing correlations for smooth and rough walls was developed.

Youn, B.↗

An entrance region friction factor model applied to annular seal analysis - Theory versus experiment for smooth and honeycomb seals

A friction factor model is developed for the entrance-region of a duct. The model is used in an annular gas seal analysis similar to Nelson's (1984). Predictions of the analysis are compared to experimental results for a smooth-stator/smooth-rotor seal and three honeycomb-stator/smooth-rotor seals. The model predicts a leakage and direct damping well. The model overpredicts the dependence of cross-coupled stiffness on fluid prerotation. The model predicts direct stiffness poorly.

Elrod, D.↗

Friction factor for isothermal and nonisothermal flow through porous media

Measurements were performed to determine the pressure drops for gaseous flow through porous materials of different microstructures, porosities, and thickness under isothermal and nonisothermal conditions at various temperature levels. Results were satisfactorily correlated by a simple equation relating the friction factor to the Reynolds number and porosities.

Koh, J. C.↗