Engineering PapersSearch

SEARCH · Engineering Papers

Results for “FREQUENCY SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of oscillations above the acoustic cut-off frequency for a sample of Kepler stars. II. Identifying temporal frequency shifts

ABSTRACT Stellar oscillations with frequencies greater than the acoustic cut-off frequency are not trapped within the star’s interior. Geometric interference between these high-frequency waves produces a peak-like structure in the power spectrum of the star, known as the pseudo-modes. In this study, we aim to analyse 51 stars previously identified (from a sample of 91 Kepler stars) to contain statistically significant evidence for pseudo-modes, to determine if the pseudo-mode frequencies vary in time. We obtained these frequency variations and the uncertainty by the resampled periodogram approach, where periodogram realisations were created from successive, overlapping 90-d time segments, and a cross-correlation function was generated between them. The computed shifts were compared against temporal p-mode frequency shifts and a stellar magnetic activity proxy, $S_{\mathrm{ph}}$. We found that for 16 per cent of the stars pseudo-mode frequency shifts were significantly anticorrelated with p-mode shifts, as is the case for the Sun. However, we also found pseudo-mode and p-mode shifts to be significantly correlated in-phase in 8 per cent of our sample. The remainder showed no significant correlation. We also searched for trends between the maximum variation of pseudo-mode frequency shifts and stellar parameters. Whilst we found no correlation between the maximum variation and stellar photospheric and chromospheric proxies, we found frequency variations to have a greater amplitude for cooler and slower rotating stars, which is in opposition to p-mode frequency shift variation. Temporal changes to pseudo-mode frequencies may be attributable to variations in stellar magnetic activity, and therefore can contribute to our understanding of stellar activity cycles.

Millson, L. J. (ORCID:0009000342542676)

The Frequency Shift and $Q$ of Disordered Superconducting RF Cavities

Niobium superconducting radio-frequency (SRF) cavities for high-energy accelerator applications have been greatly improved in terms of the quality factor $Q$ by techniques such as Nitrogen doping. However, the mechanisms leading to improvement in $Q$ are still not fully understood. Quite recently the SRF group at Fermilab measured anomalies in the frequency shift of N-doped SRF Niobium cavities near the transition temperature. Here we report our theoretical analysis of these results based on the microscopic theory of superconductivity that incorporates anisotropy of the superconducting gap and inhomogeneous disorder in the screening region of the SRF cavities. We are able to account for frequency shift anomalies very close to $T_c$ on the order of fractions of 1 kHz. Our results for the frequency shift and Q are in good agreement with the experimental data reported for all four N-doped Nb SRF cavities by Bafia et al. We also compare our theory with an earlier report on a Nb sample measured at 60 GHz. In addition, we show that the quality factor calculated theoretically has a peak of upper convexity with the largest $Q$ at intermediate levels of disorder. For strong disorder, i.e. the dirty limit, pair breaking in the presence of disorder and screening currents limits the $Q$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Frequency shifts in the electron paramagnetic resonance spectrum of 39 K due to spin-exchange collisions with polarized 3 He and precise 3 He polarimetry

The Zeeman splittings and electron paramagnetic resonance frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter 𝜅 0 that is unique to each alkali-metal-atom–noble-gas pair. Here, we present a precise measurement of 𝜅 0 for the 39 K − 3 He system with a relative accuracy of better than 1%. A critical component of achieving subpercent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter 𝜅 0 plays an important role in establishing the absolute polarization of 3 He in a variety of contexts, including polarized targets for electron-scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using 𝜅 0 for polarimetry purposes. Just as important, the work presented here represents a direct measurement of 𝜅 0 for the 39 K − 3 He system; previous values for 𝜅 0 in the 39 K − 3 He system relied on a chain of measurements that were benchmarked by previous measurements of 𝜅 0 in the Rb- 3 He system.

Zeeman effect

Real-Time GPU-Accelerated OFDR With an Integrated Auxiliary Interferometer

A GPU-accelerated optical frequency domain reflectometry (OFDR) system with an improved integrated auxiliary interferometer is proposed. Unlike conventional approaches that require separate auxiliary interferometers and multiple detection channels, the proposed OFDR system embeds this functionality directly into the signal via an intentional beat component. This enables self-calibration of laser nonlinearity while maintaining a cost-effective hardware configuration. Building on this simplified configuration, the system leverages GPU acceleration with an NVIDIA RTX 4070 Ti to achieve real-time performance, delivering high-throughput signal processing for continuous OFDR interrogation. The signal processing pipeline comprises signal capture, resampling for nonlinearity compensation, and frequency shift computation, all optimized for parallel execution. Hardware benchmarking demonstrates substantial acceleration over CPU implementations, achieving up to a 45× speedup for resampling and frequency shift computations and enabling processing latencies below 30 ms. Thermal response validation is conducted under two complementary scenarios: localized heating using a water bath and cryogenic-temperature conditions using liquid nitrogen. Under localized heating, the system achieves an accuracy of 0.249 °C with a thermal sensitivity of 5.971 GHz/°C, while cryogenic-temperature validation demonstrates a frequency shift response with a sensitivity of 2.383 GHz/°C and an accuracy of 2.04 °C. The high acceleration of the proposed GPU-accelerated OFDR system and its accuracy are achieved by exploiting CUDA-based stride indexing, enabling efficient parallel segmentation and processing of large datasets without additional memory copies. The benchmarking results confirm the robustness, accuracy, and deployability of the proposed OFDR system across a wide temperature range, establishing it as a practical platform for real-time distributed fiber sensing in structurally dynamic environments.

Harb, Salah [Lawrence Berkeley National Laboratory

Results from Extended Range SRF Cavity Tuner Tests for LCLS-II HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all tests, the tuners achieved a frequency shift of -565±80 kHz. This study will discuss cavity frequency during each step as it is being assembled in the cryomodule string and finally when it is being tested at 2 K. Tracking the cavity frequency helped enable the tuners to reach this large frequency shift. The specific procedures of tuner setting during assembly will be presented

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Frequency‐Locked Wireless Multifunctional Surface Acoustic Wave Sensors

Abstract Surface acoustic waves (SAWs) have shown great potential for developing sensors for structural health monitoring (SHM) and lab‐on‐a‐chip (LOC) applications. Existing SAW sensors mainly rely on measuring the frequency shifts of high‐frequency (e.g., >0.1 GHz) resonance peaks. This study presents frequency‐locked wireless multifunctional SAW sensors that enable multiple wireless sensing functions, including strain sensing, temperature measurement, water presence detection, and vibration sensing. These sensors leverage SAW resonators on piezoelectric chips, inductive coupling‐based wireless power transmission, and, particularly, a frequency‐locked wireless sensing mechanism that works at low frequencies (e.g., <0.1 GHz). This mechanism locks the input frequency on the slope of a sensor's reflection spectrum and monitors the reflection signal's amplitude change induced by the changes of sensing parameters. The proof‐of‐concept experiments show that these wireless sensors can operate in a low‐power active mode for on‐demand wireless strain measurement, temperature sensing, and water presence detection. Moreover, these sensors can operate in a power‐free passive mode for vibration sensing, with results that agree well with laser vibrometer measurements. It is anticipated that the designs and mechanisms of the frequency‐locked wireless SAW sensors will inspire researchers to develop future wireless multifunctional sensors for SHM and LOC applications.

Bo, Luyu

Results from extended range SRF cavity tuner tests for LCLS-II-HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all the tests the tuners successfully achieved a frequency shift of -565±80 kHz from the 1.3 GHz value. This study discusses the cavity frequency during each stage of assembly from the cryomodule string to when they are finally tested at 2 K. Monitoring the cavity frequency from this initial stage contributed in reaching this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS

Significant acceleration of solid-state NMR simulations via three-angle powder averaging

The anisotropic frequency shifts imparted onto the NMR resonance frequency depend on the spherical angular coordinates that describe the orientations of the NMR interaction tensors with respect to the applied magnetic field direction. Experiments performed using magic-angle spinning, however, gain a dependence on a third angle: the rotor phase γ. Traditionally, a carousel average is performed to integrate over γ, which leads to a slow convergence of intensities without contributing to the underlying powder patterns. Herein, we show an order of magnitude acceleration in computation time may be obtained by including the γ-averaging into the main powder average to eliminate redundant calculation of resonance frequencies.

magic-angle spinning

Utah FORGE: 16B(78)-32 RFS DSS Strain Change Rate vs. Depth During 16A(78)-32 Stimulation

This dataset contains strain change rate versus depth data acquired using a Rayleigh frequency shift (RFS) distributed strain sensing (DSS) system during hydraulic stimulation of well 16A(78)-32 at the Utah FORGE site in April 2024. The data were collected from an optical fiber installed in the annulus of production well 16B(78)-32, approximately 300 feet from the injection well. The dataset includes tabulated strain data and an explanation of the methodology used to generate the frac log, which integrates strain change rate signals over selected time windows to identify fracture events.

15 GEOTHERMAL ENERGY

Utah FORGE: Fiber Optic Cumulative Strain Change and Strain Change Rate Data From Well 16A Stimulation at Well 16B

This dataset includes Rayleigh Frequency Shift (RFS) Distributed Strain Sensing (DSS) cumulative strain change and change rate data. The data was acquired during the stimulation of Utah FORGE Well 16A(78)-32 in April 2024 via fiber installed in Well 16B(78)-32. The fiber optic data was acquired using Neubrex SR7000 RFS DSS Distributed Strain sensing instruments and is saved here in the format of HDF5 files (.h5 extension). The spatial sampling on the full wellbore profiles is 0.20 centimeters. The data is the far field strain change response from a baseline profile made down the 16B well on April 3, 2024, so each strain value represents the strain change or strain change rate at each depth relative to the baseline reference profile. The data arrays for each type share the same dimensions (number of channels and time stamps).

15 GEOTHERMAL ENERGY

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION

Investigation of coverage dependence of the stretching frequency of CO adsorbed on Pd surfaces at low coverage limits

The stretching frequency of the C—O bond is a sensitive probe of the local environment of a surface-bound CO molecule, including the adorption site and density, i.e. surface coverage. In this work, we extend our analysis beyond the frequency shift due to differences in adsorption configurations. Using density functional theory (DFT) calculations, we directly explore the correlations between surface coverage and the stretching frequency of adsorbed CO on Pd surfaces. Here we also perform constant pressure infrared reflection absorption measurements of CO on Pd(111) and use existing relations between pressure and coverage to derive coverage dependency. Both results are compared to previously reported experimental data. Our derived correlations of peak frequency and area with surface coverage can help interpret experimental IR spectra in real time and extract time-dependent concentration data from transient kinetic experiments.

77 NANOSCIENCE AND NANOTECHNOLOGY

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics

Zero-added-loss entanglement multiplexing using time-bin spectral shearing

High-quality quantum communications that enable important capabilities, such as distributed quantum computing and sensing, will require quantum repeaters for providing high-quality entanglement. To realize high-rate heralded entanglement for quantum repeaters, Chen et al . [Phys. Rev. Appl. 19 , 054029 (2023)] proposed a scheme for heralded-multiplexed generation of quasideterministic entangled photon pairs, called zero-added-loss multiplexing (ZALM). Here, we propose a design of the ZALM source using time-bin entanglement and spectral shearing. Additionally, we provide an analysis of experimentally relevant spectral-shearing parameters to optimize the spectral multiplexing. Moreover, we experimentally verify the compatibility of time-bin pulses and spectral shearing, as supported by observation of no appreciable phase shift when the same shearing is applied to both time bins. These results expand the benefits of applying a ZALM source to time-bin entanglement use cases. Moreover, more fully demonstrating time-bin and spectral shearing compatibility clears a path toward a broader use of spectral shearing that provides a deterministic frequency shift of high utility.

entanglement production

Magnetic anisotropy and GGG substrate stray field in YIG films down to millikelvin temperatures

Abstract Quantum magnonics investigates the quantum-mechanical properties of magnons, such as quantum coherence or entanglement for solid-state quantum information technologies at the nanoscale. The most promising material for quantum magnonics is the ferrimagnetic yttrium iron garnet (YIG), which hosts magnons with the longest lifetimes. YIG films of the highest quality are grown on a paramagnetic gadolinium gallium garnet (GGG) substrate. The literature has reported that ferromagnetic resonance (FMR) frequencies of YIG/GGG decrease at temperatures below 50 K despite the increase in YIG magnetization. We investigated a 97 nm-thick YIG film grown on 500 μm-thick GGG substrate through a series of experiments conducted at temperatures as low as 30 mK, and using both analytical and numerical methods. Our findings suggest that the primary factor contributing to the FMR frequency shift is the stray magnetic field created by the partially magnetized GGG substrate. This stray field is antiparallel to the applied external field and is highly inhomogeneous, reaching up to 40 mT in the center of the sample. At temperatures below 500 mK, the GGG field exhibits a saturation that cannot be described by the standard Brillouin function for a paramagnet. Including the calculated GGG field in the analysis of the FMR frequency versus temperature dependence allowed the determination of the cubic and uniaxial anisotropies. We find that the total crystallographic anisotropy increases more than three times with the decrease in temperature down to 2 K. Our findings enable accurate predictions of the YIG/GGG magnetic systems behavior at low and ultralow millikelvin temperatures, crucial for developing quantum magnonic devices.

Serha, Rostyslav O.