Engineering PapersSearch

SEARCH · Engineering Papers

Results for “FREQUENCY CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Linear voltage-to-frequency converter

Voltage-to-frequency converter, with ultra-high input impedance and linear response, is used in analog to digital data conversion systems. Voltage-to-current converter, using MOSFET devices and a multivibrator, has ultra-linear voltage-to-frequency characteristics. It replaces voltage sensitive magnetic-core oscillators.

Lokerson, D. C.

Pneumatic analog-to-pulse frequency converter

Pneumatic analog-to-pulse frequency converter circuit has output pulse frequency proportional to the pressure level of the input signal. Converter circuit drives a pneumatic stepping motor and is part of a pneumatic control system for nuclear powered spacecraft.

Dustin, M. O.

A MAGNETIC CORE VOLTAGE-TO-FREQUENCY CONVERTER

Controlling the frequency of a square-loop magnetic core oscillator using a dc voltage to give a voltage-to-frequency conversion for use in pulse frequency modulated telemetry systems

PFM TELEMETRY

Telecom-to-visible quantum frequency converter on a silicon nitride chip

Quantum frequency conversion serves a key role in the realization of hybrid quantum networks by interfacing between wavelength-incompatible platforms. Here we present what is believed to be the first quantum frequency converter connecting visible and telecom domains on a silicon nitride (SiN) chip, using Bragg-scattering four-wave mixing to upconvert heralded single photons from 1260 to 698 nm, which covers a 192 THz span. We examine the noise sources in SiN and devise approaches to suppress noise photons at the source and target frequencies to enable measurements at the single-photon level. We demonstrate an on-chip conversion efficiency of 5% in photon flux and describe design modifications that can be implemented to significantly improve it. Our results pave the way for the implementation of complementary metal-oxide-semiconductor (CMOS)-compatible devices in quantum networks.

59 BASIC BIOLOGICAL SCIENCES

A voltage to frequency converter for astronomical photometry

A voltage to frequency converter (VFC) for general use with photomultipliers is described. For high light levels, when the dead-time corrections for a photon counter would be excessive, the VFC maintains a linear response and allows the recording of data at high time resolution. Results of laboratory tests are given for the signal-to-noise characteristics, linearity, stability, and transient response of the VFC when used in conjunction with EMI 9658 and RCA C31034 photomultipliers.

Dunham, E.

Total Ionizing Dose Effects on Voltage-to-Frequency Converters

This paper discusses total dose effects on voltage-to-frequency converters which impose different requirements on internal circuitry, and are also very high-precision devices (for example, linearity is typically specified between 0.002 and 0.05%).

low dose rate (LDR) Voltage-to-Frequency Converter

Static Frequency Converter System Installed and Tested

A new Static Frequency Converter (SFC) system has been installed and tested at the NASA Glenn Research Center s Central Air Equipment Building to provide consistent, reduced motor start times and improved reliability for the building s 14 large exhausters and compressors. The operational start times have been consistent around 2 min, 20 s per machine. This is at least a 3-min improvement (per machine) over the old variable-frequency motor generator sets. The SFC was designed and built by Asea Brown Boveri (ABB) and installed by Encompass Design Group (EDG) as part of a Construction of Facilities project managed by Glenn (Robert Scheidegger, project manager). The authors designed the Central Process Distributed Control Systems interface and control between the programmable logic controller, solid-state exciter, and switchgear, which was constructed by Gilcrest Electric.

Brown, Donald P.

Resonantly two-photon pumped frequency converter

This letter describes a resonantly two-photon pumped frequency converter with application to the generation of tunable ultraviolet and vacuum ultraviolet radiation and also to infrared-to-visible up-conversion and imaging. Calculations show that up-conversion power efficiencies in excess of 100% should be obtained with tunable dye lasers having peak powers in the hundred watt to kilowatt range.

Harris, S. E.

A simple method for converting frequency domain aerodynamics to the time domain

A simple, direct procedure was developed for converting frequency domain aerodynamics into indicial aerodynamics. The data required for aerodynamic forces in the frequency domain may be obtained from any available (linear) theory. The method retains flexibility for the analyst and is based upon the particular character of the frequency domain results. An evaluation of the method was made for incompressible, subsonic, and transonic two dimensional flows.

Dowell, E. H.

Voltage-To-Frequency Converter For Pressure Calibration

Measurements of pressures on walls of wind tunnels and on surfaces of models in wind tunnels made with help of electronically scanned pressure-measurement (ESP) system. Voltage-to-frequency converter circuit, designed to convert 0- to 5-Vdc analog output voltage from high-line-pressure, low-differential-pressure standard to required frequency range. Enables selection of wider variety of high-accuracy pressure standards to enhance accuracy of measurement of ESP instrumentation while requiring little modification of manufacturer's system and no modification of operating software of system. Useful primarily in wind-tunnel instrumentation and readily adaptable to commercial instruments currently in use.

Sealey, Bradley S.

Study of switching transients in high frequency converters

As the semiconductor technologies progress rapidly, the power densities and switching frequencies of many power devices are improved. With the existing technology, high frequency power systems become possible. Use of such a system is advantageous in many aspects. A high frequency ac source is used as the direct input to an ac/ac pulse-density-modulation (PDM) converter. This converter is a new concept which employs zero voltage switching techniques. However, the development of this converter is still in its infancy stage. There are problems associated with this converter such as a high on-voltage drop, switching transients, and zero-crossing detecting. Considering these problems, the switching speed and power handling capabilities of the MOS-Controlled Thyristor (MCT) makes the device the most promising candidate for this application. A complete insight of component considerations for building an ac/ac PDM converter for a high frequency power system is addressed. A power device review is first presented. The ac/ac PDM converter requires switches that can conduct bi-directional current and block bi-directional voltage. These bi-directional switches can be constructed using existing power devices. Different bi-directional switches for the converter are investigated. Detailed experimental studies of the characteristics of the MCT under hard switching and zero-voltage switching are also presented. One disadvantage of an ac/ac converter is that turn-on and turn-off of the switches has to be completed instantaneously when the ac source is at zero voltage. Otherwise shoot-through current or voltage spikes can occur which can be hazardous to the devices. In order for the devices to switch softly in the safe operating area even under non-ideal cases, a unique snubber circuit is used in each bi-directional switch. Detailed theory and experimental results for circuits using these snubbers are presented. A current regulated ac/ac PDM converter built using MCT's and IGBT's is evaluated.

Zinger, Donald S.

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman