Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREE ENTHALPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heat flux and shock shape measurements on an Aeroassist Flight Experiment model in a high enthalpy free piston shock tunnel

This paper describes measurements of heat flux and shock shapes made on a 2.08 percent scale model of the proposed Aeroassist Flight Experiment model in a high enthalpy free piston shock tunnel T3 at the Australian National University in Canberra, Australia. The enthalpy and Reynolds number range covered were 7.5 MJ/kg to 20 MJ/kg and 150,000 to 270,000 per meter respectively. The test Mach number varied between 7.5 and 8. Two test gases, air and nitrogen, were used and the model angle of attack varied from -10 deg to +10 deg to the free stream. The results are discussed and compared to the Mach 10 cold hypersonic air data as obtained in the Langley 31 inch Mach 10 Facility as well as the perfect gas CFD calculations of NASA LaRC.

Gai, S. L.↗

Planar laser-induced fluorescence measurements of high-enthalpy free jet flow with nitric oxide

Planar laser-induced fluorescence (PLIF) measurements of property fields in a high-enthalpy, supersonic, underexpanded free jet generated in a reflection-type shock tunnel are reported. PLIF images showing velocity and temperature sensitivity are presented. The inferred radial velocity and relative rotational temperature fields are found to be in agreement with those predicted by a numerical simulation of the flowfield using the method of characteristics.

Palmer, Jennifer L.↗

Chemical equilibrium

The entropy of a gas system with the number of particles subject to external control is maximized to derive relations between the thermodynamic variables that obtain at equilibrium. These relations are described in terms of the chemical potential, defined as equivalent partial derivatives of entropy, energy, enthalpy, free energy, or free enthalpy. At equilibrium, the change in total chemical potential must vanish. This fact is used to derive the equilibrium constants for chemical reactions in terms of the partition functions of the species involved in the reaction. Thus the equilibrium constants can be determined accurately, just as other thermodynamic properties, from a knowledge of the energy levels and degeneracies for the gas species involved. These equilibrium constants permit one to calculate the equilibrium concentrations or partial pressures of chemically reacting species that occur in gas mixtures at any given condition of pressure and temperature or volume and temperature.

Source record↗

Canonical fluid thermodynamics

The space-time integral of the thermodynamic pressure plays the role of the thermodynamic potential for compressible, adiabatic flow in the sense that the pressure integral for stable flow is less than for all slightly different flows. This stability criterion can be converted into a variational minimum principle by requiring the molar free-enthalpy and the temperature, which are the arguments of the pressure function, to be generalized velocities, that is, the proper-time derivatives of scalar spare-time functions which are generalized coordinates in the canonical formalism. In a fluid context, proper-time differentiation must be expressed in terms of three independent quantities that specify the fluid velocity. This can be done in several ways, all of which lead to different variants (canonical transformations) of the same constraint-free action integral whose Euler-Lagrange equations are just the well-known equations of motion for adiabatic compressible flow.

Schmid, L. A.↗

Canonical fluid thermodynamics

The space-time integral of the thermodynamic pressure plays in a certain sense the role of the thermodynamic potential for compressible adiabatic flow. The stability criterion can be converted into a variational minimum principle by requiring the molar free-enthalpy and temperature to be generalized velocities. In the fluid context, the definition of proper-time differentiation involves the fluid velocity expressed in terms of three particle identity parameters. The pressure function is then converted into a functional which is the Lagrangian density of the variational principle. Being also a minimum principle, the variational principle provides a means for comparing the relative stability of different flows. For boundary conditions with a high degree of symmetry, as in the case of a uniformly expanding spherical gas box, the most stable flow is a rectilinear flow for which the world-trajectory of each particle is a straight line. Since the behavior of the interior of a freely expanding cosmic cloud may be expected to be similar to that of the fluid in the spherical box of gas, this suggests that the cosmic principle is a consequence of the laws of thermodynamics, rather than just an ad hoc postulate.

Schmid, L. A.↗

CSCM methodology for slot injection cooled cavity flow design in a high enthalpic stream

The CSCM method for the compressible Navier-Stokes equations is applied to study design factors in a slot injection cooled cavity flow in the side of a 2-D wedge body in a high enthalpy free stream. The flow geometry is being designed and will be tested in an arc jet tunnel at NASA-Ames Research Center. Objectives of the design are to provide adequate thermal protection for and minimize aero-optical distortion in the path above a window located in the bottom of the cavity. Among design issues, are the geometry of and flow conditions in the expanding section of the supersonic slot injection nozzle. Here, for straight walled nozzles, two geometries are considered for the upper nozzle lip between the hot, high speed outer flow and the colder, denser cooling flow. The two lip geometries - thick, square and thin, wedge - as the result of associated widely differing base/wake flows also exhibit different and interesting viscous-inviscid flow structures near the ramp termination to the cavity. For the thin lip case, the consequences on flow quality of off design nozzle conditions relative to matching pressure with the outer flow are explored.

Bardina, Jorge↗

Arc Jet Flow Properties Determined from Laser-Induced Fluorescence of Atomic Nitrogen

An laser-spectroscopic investigation of the thermocheMical state of arcjet flows is currently being conducted in the Aerodynamic Heating Facility (AHF) Circlet at NASA Ames Research Center. Downstream of the nozzle exit, but upstream of the test article, Laser-Induced Fluorescence (LIF) of atomic nitrogen is used to assess the nonequilibriuM distribution of flow enthalpy in the free stream. The two-photon LIF technique provides simultaneous measurements of free stream velocity, translational temperature, and nitrogen number density on the flow centerline. Along with information from facility instrumentation, these measurements allow a determination of the free stream total enthalpy, and its apportionment in to thermal, kinetic, and chemical mode contributions. Experimental results are presented and discussed for two different niti-ogen/argon test gas flow runs during which the current is varied while the pressure remains constant .

Fletcher, Douglas↗

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.↗

Thermochemistry of Strong Air Plasmas for Hypervelocity Earth Entry of Asteroids

The specific heat, enthalpy and free energy of nitrogen and oxygen are calculated for pressures between 1 and 100 bars and temperatures between 10,000 and 100,000 degrees Kelvin. The data are presented in a form suitable for input into computational fluid dynamics computer codes. This range of temperature and pressure are typical of the conditions expected in the bow shock layer of a meteor or small asteroid entering Earth's atmosphere. The extent of double and triple ionization of nitrogen and oxygen atoms under these conditions will be estimated.

Ionization Energy Depression↗

Comparison between thermochemical and phase stability data for the quartz-coesite-stishovite transformations

Phase stability and elasticity data have been used to calculate the Gibbs free energy, enthalpy, and entropy changes at 298 K and 1 bar associated with the quartz-coesite and coesite-stishovite transformations in the system SiO2. For the quartz-coesite transformation, these changes disagree by a factor of two or three with those obtained by calorimetric techniques. The phase boundary for this transformation appears to be well determined by experiment; the discrepancy, therefore, suggests that the calorimetric data for coesite are in error. Although the calorimetric and phase stability data for the coesite-stishovite transformation yield the same transition pressure at 298 K, the phase-boundary slopes disagree by a factor of two. At present, it is not possible to determine which of the data are in error. Thus serious inconsistencies exist in the thermodynamic data for the polymorphic transformations of silica.

Weaver, J. S.↗

A clean air continuous flow propulsion facility

Consideration is given to a contaminant-free, high enthalpy, continuous flow facility designed to obtain detailed code validation measurements of high speed combustion. The facility encompasses uncontaminated air temperature control to within 5 K, fuel temperature control to 2 K, a ceramic flow straightener, drying of inlet air, and steady state continuous operation. The air heating method provides potential for independent control of contaminant level by injection, mixing, and heating upstream. Particular attention is given to extension of current capability of 1250 K total air temperature, which simulates Scramjet enthalpy at Mach 5.

Krauss, R. H.↗

A Theoretical Analysis of Effects of Ablation on Heat Transfer to an Arbitrary Axisymmetric Body

An analysis has been performed t o determine the effect of mass injection on heat transfer to an arbitrary surface of revolution. effective heat of ablation is determined, and the downstream effects of injection are investigated. It is found that the linear relation between heat of ablation and difference between wall and free-stream enthalpy, previously verified at the stagnation point, provides a useful approximation at any point on a surface of revolution. From the investigation of the downstream effects of injection it is found that an appreciable rate of heating may be obtained, even at points considerably downstream from the point at which injection ends. However, the radiation equilibrium temperature is proportional to the fourth root of the heating rate; therefore, except in particular cases, it will be difficult to make use of this effect in the design of thermal protection systems. Effects of radiation from a hot gas layer to the ablating surface are investigated by an approximate procedure. The efficiency of ablation is found to approach a maximum value which depends on the ratio of radiant heating to aerodynamic heating and is independent of the enthalpy difference across the boundary layer.

Swann, Robert T.↗

A numerical investigation into the effects of compressibility and total enthalpy difference on the development of a laminar free shear layer.

A method is presented for integrating numerically the equations of motion for a compressible free shear layer developing from a boundary-layer profile of arbitrary shape. Sutherland's law is used to determine the coefficient of viscosity and the Prandtl number is taken as 0.72. Calculated results are reported for free-stream Mach numbers ranging from 0 to 10 and for stagnation-enthalpy ratios ranging from 0 to 5.0. The effects of varying the initial boundary-layer profile and of a discontinuity in temperature at the origin are also studied. The results include graphs showing the development of dividing-streamline velocity, of local Nusselt number, and of dividing-streamline location.

Carpenter, P. W.↗