Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUX DENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Planck intermediate results: LII. Planet flux densities

Measurements of flux density are described for five planets, Mars, Jupiter, Saturn, Uranus, and Neptune, across the six Planck High Frequency Instrument frequency bands (100-857 GHz) and these are then compared with models and existing data. In our analysis, we have also included estimates of the brightness of Jupiter and Saturn at the three frequencies of the Planck Low Frequency Instrument (30, 44, and 70 GHz). The results provide constraints on the intrinsic brightness and the brightness time-variability of these planets. The majority of the planet flux density estimates are limited by systematic errors, but still yield better than 1% measurements in many cases. Applying data from Planck HFI, the Wilkinson Microwave Anisotropy Probe (WMAP), and the Atacama Cosmology Telescope (ACT) to a model that incorporates contributions from Saturn's rings to the planet's total flux density suggests a best fit value for the spectral index of Saturn's ring system of β ring = 2.30 ± 0.03 over the 30-1000 GHz frequency range. Estimates of the polarization amplitude of the planets have also been made in the four bands that have polarization-sensitive detectors (100-353 GHz); this analysis provides a 95% confidence level upper limit on Mars's polarization of 1.8, 1.7, 1.2, and 1.7% at 100, 143, 217, and 353 GHz, respectively. The average ratio between the Planck -HFI measurements and the adopted model predictions for all five planets (excluding Jupiter observations for 353 GHz) is 1.004, 1.002, 1.021, and 1.033 for 100, 143, 217, and 353 GHz, respectively. Model predictions for planet thermodynamic temperatures are therefore consistent with the absolute calibration of Planck -HFI detectors at about the three-percent level. We compare our measurements with published results from recent cosmic microwave background experiments. In particular, we observe that the flux densities measured by Planck HFI and WMAP agree to within 2%. These results allow experiments operating in the mm-wavelength range to cross-calibrate against Planck and improve models of radiative transport used in planetary science.

79 ASTRONOMY AND ASTROPHYSICS↗

AN ACCURATE FLUX DENSITY SCALE FROM 1 TO 50 GHz

We develop an absolute flux density scale for centimeter-wavelength astronomy by combining accurate flux density ratios determined by the Very Large Array between the planet Mars and a set of potential calibrators with the Rudy thermophysical emission model of Mars, adjusted to the absolute scale established by the Wilkinson Microwave Anisotropy Probe. The radio sources 3C123, 3C196, 3C286, and 3C295 are found to be varying at a level of less than {approx}5% per century at all frequencies between 1 and 50 GHz, and hence are suitable as flux density standards. We present polynomial expressions for their spectral flux densities, valid from 1 to 50 GHz, with absolute accuracy estimated at 1%-3% depending on frequency. Of the four sources, 3C286 is the most compact and has the flattest spectral index, making it the most suitable object on which to establish the spectral flux density scale. The sources 3C48, 3C138, 3C147, NGC 7027, NGC 6542, and MWC 349 show significant variability on various timescales. Polynomial coefficients for the spectral flux density are developed for 3C48, 3C138, and 3C147 for each of the 17 observation dates, spanning 1983-2012. The planets Venus, Uranus, and Neptune are included in our observations, and we derive their brightness temperatures over the same frequency range.

79 ASTRONOMY AND ASTROPHYSICS↗

A model of heat transfer in sapwood and implications for sap flux density measurements using thermal dissipation probes

A variety of thermal approaches are used to estimate sap flux density in stems of woody plants. Models have proven valuable tools for interpreting the behavior of heat pulse, heat balance, and heat field deformation techniques, but have seldom been used to describe heat transfer dynamics for the heat dissipation method. Therefore, to better understand the behavior of heat dissipation probes, a model was developed that takes into account the thermal properties of wood, the physical dimensions and thermal characteristics of the probes, and the conductive and convective heat transfer that occurs due to water flow in the sapwood. Probes were simulated as aluminum tubes 20 mm in length and 2 mm in diameter, whereas sapwood, heartwood, and bark each had a density and water fraction that determined their thermal properties. Base simulations assumed a constant sap flux density with sapwood depth and no wounding or physical disruption of xylem beyond the 2 mm diameter hole drilled for probe installation. Simulations across a range of sap flux densities showed that the dimensionless quantity k defined as ( Tm T)/ T where Tm is the temperature differential ( T) between the heated and unheated probe under zero flow conditions was dependent on the thermal conductivity of the sapwood. The relationship between sap flux density and k was also sensitive to radial gradients in sap flux density and to xylem disruption near the probe. Monte Carlo analysis in which 1000 simulations were conducted while simultaneously varying thermal conductivity and wound diameter revealed that sap flux density and k showed considerable departure from the original calibration equation used with this technique. The departure was greatest for abrupt patterns of radial variation typical of ring-porous species. Depending on the specific combination of thermal conductivity and wound diameter, use of the original calibration equation resulted in an 81% under- to 48% over-estimation of sap flux density at modest flux rates. Future studies should verify these simulations and assess their utility in estimating sap flux density for this widely used technique.

09 BIOMASS FUELS↗

Magnetic flux density in the heliosphere through several solar cycles

We studied the magnetic flux density carried by solar wind to various locations in the heliosphere, covering a heliospheric distance range of 0.3-5.4 AU and a heliolatitudinal range from 80° south to 80° north. Distributions of the radial component of the magnetic field, B{sub R} , were determined over long intervals from the Helios, ACE, STEREO, and Ulysses missions, as well as from using the 1 AU OMNI data set. We show that at larger distances from the Sun, the fluctuations of the magnetic field around the average Parker field line distort the distribution of B{sub R} to such an extent that the determination of the unsigned, open solar magnetic flux density from the average (|B{sub R} |) is no longer justified. We analyze in detail two methods for reducing the effect of fluctuations. The two methods are tested using magnetic field and plasma velocity measurements in the OMNI database and in the Ulysses observations, normalized to 1 AU. It is shown that without such corrections for the fluctuations, the magnetic flux density measured by Ulysses around the aphelion phase of the orbit is significantly overestimated. However, the matching between the in-ecliptic magnetic flux density at 1 AU (OMNI data) and the off-ecliptic, more distant, normalized flux density by Ulysses is remarkably good if corrections are made for the fluctuations using either method. The main finding of the analysis is that the magnetic flux density in the heliosphere is fairly uniform, with no significant variations having been observed either in heliocentric distance or heliographic latitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-term Longitudinal Recurrences of the Open Magnetic Flux Density in the Heliosphere

Open magnetic flux in the heliosphere is determined from the radial component of the magnetic field vector measured onboard interplanetary space probes. Previous Ulysses research has shown remarkable independence of the flux density from heliographic latitude, explained by super-radial expansion of plasma. Here we are investigating whether any longitudinal variation exists in the 50 year long OMNI magnetic data set. The heliographic longitude of origin of the plasma package was determined by applying a correction according to the solar wind travel time. Significant recurrent enhancements of the magnetic flux density were observed throughout solar cycle 23, lasting for several years. Similar, long-lasting recurring features were observed in the solar wind velocity, temperature and the deviation angle of the solar wind velocity vector from the radial direction. Each of the recurrent features has a recurrence period slightly differing from the Carrington rotation rate, although they show a common trend in time. Examining the coronal temperature data of ACE leads to the possible explanation that these long-term structures are caused by slow–fast solar wind interaction regions. A comparison with MESSENGER data measured at 0.5 au shows that these longitudinal magnetic modulations do not exist closer to the Sun, but are the result of propagation.

79 ASTRONOMY AND ASTROPHYSICS↗

WHAT DOES A SUBMILLIMETER GALAXY SELECTION ACTUALLY SELECT? THE DEPENDENCE OF SUBMILLIMETER FLUX DENSITY ON STAR FORMATION RATE AND DUST MASS

We perform three-dimensional dust radiative transfer (RT) calculations on hydrodynamic simulations of isolated and merging disk galaxies in order to quantitatively study the dependence of observed-frame submillimeter (submm) flux density on galaxy properties. We find that submm flux density and star formation rate (SFR) are related in dramatically different ways for quiescently star-forming galaxies and starbursts. Because the stars formed in the merger-induced starburst do not dominate the bolometric luminosity and the rapid drop in dust mass and more compact geometry cause a sharp increase in dust temperature during the burst, starbursts are very inefficient at boosting submm flux density (e.g., a {approx}> 16 Multiplication-Sign boost in SFR yields a {approx}< 2 Multiplication-Sign boost in submm flux density). Moreover, the ratio of submm flux density to SFR differs significantly between the two modes; thus one cannot assume that the galaxies with highest submm flux density are necessarily those with the highest bolometric luminosity or SFR. These results have important consequences for the bright submillimeter-selected galaxy (SMG) population. Among them are: (1) The SMG population is heterogeneous. In addition to merger-driven starbursts, there is a subpopulation of galaxy pairs, where two disks undergoing a major merger but not yet strongly interacting are blended into one submm source because of the large ({approx}> 15'' or {approx}130 kpc at z = 2) beam of single-dish submm telescopes. (2) SMGs must be very massive (M{sub *} {approx}> 6 Multiplication-Sign 10{sup 10} M{sub Sun }). (3) The infall phase makes the SMG duty cycle a factor of a few greater than what is expected for a merger-driven starburst. Finally, we provide fitting functions for SCUBA and AzTEC submm flux densities as a function of SFR and dust mass and bolometric luminosity and dust mass; these should be useful for calculating submm flux density in semi-analytic models and cosmological simulations when performing full RT is computationally not feasible.

79 ASTRONOMY AND ASTROPHYSICS↗

MAGNETIC FLUX DENSITY MEASURED IN FAST AND SLOW SOLAR WIND STREAMS

The radial component of the heliospheric magnetic field vector is used to estimate the open magnetic flux density of the Sun. This parameter has been calculated using observations from the Ulysses mission that covered heliolatitudes from 80 Degree-Sign S to 80 Degree-Sign N, from 1990 to 2009 and distances from 1 to 5.4 AU, the Advanced Composition Explorer mission at 1 AU from 1997 to 2010, the OMNI interplanetary database from 1971, and the Helios 1 and 2 missions that covered the distance range from 0.3 to 1 AU. The flux density was found to be much affected by fluctuations in the magnetic field which make its calculated value dependent on heliospheric location, type of solar wind (fast or slow), and the level of solar activity. However, fluctuations are distributed symmetrically perpendicular to the average Parker direction. Therefore, distributions of the field vector in the two-dimensional plane defined by the radial and azimuthal directions in heliospheric coordinates provide a way to reduce the effects of the fluctuations on the measurement of the flux density. This leads to a better defined flux density parameter; the distributions modified by removing the effects of fluctuations then allow a clearer assessment of the dependence of the flux density on heliospheric location, solar wind type, and solar activity. This assessment indicates that the flux density normalized to 1 AU is independent of location and solar wind type (fast or slow). However, there is a residual dependence on solar activity which can be studied using the modified flux density measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Gauge-invariant perturbation expansion in powers of electric charge for the density-of-states of a network model for charged-particle motion in a uniform background magnetic flux density

An explicitly gauge-invariant expansion in powers of e/$\hbar$ times the magnetic flux density is formally obtained for the density of states [as characterized by the trace of the resolvent $\hat{G}$ = (ω-$\hat{ℎ}$)-1] of a charged particle moving on a Hermitian quantum network that is embedded in a Euclidean background that supports a uniform magnetic flux density. The explicit expressions, given here up to third order in the flux density, are also valid for the “local trace” (the trace of $\hat{P}_i\hat{G}$ , where $\hat{P}_i$ is the projector on a network node) and do not appear to have been previously given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chemical sputtering of graphite by low temperature nitrogen plasmas at various substrate temperatures and ion flux densities

We report measurements of chemical sputtering yields of graphite exposed to low temperature nitrogen plasmas. The influence of surface temperature and incoming ion energy on the sputtering yields has been investigated in two distinct ion flux density regimes. Sputtering yields grow consistently with increasing temperatures in experiments with low flux density (Γ{sub i}≈10{sup 20} m{sup −2}s{sup −1}−10{sup 21} m{sup −2}s{sup −1}) and high flux density (Γ{sub i}≈10{sup 23} m{sup −2}s{sup −1}). Moreover, empirical fitting of the data suggests that the temperature of 670 °C is optimal for chemical sputtering at high flux density. Negative biasing of the samples was used to vary the ion energy in the low flux density regime. The sputtering yield in this case increases from 0.07 atoms/ion for E{sub i} = 1.5 eV to 0.19 atoms/ion for E{sub i} = 35 eV. After taking into account the dependence of the yields on temperature and ion energy, we evidenced a flux dependence of sputtering, similar to that found for chemical sputtering of carbon by hydrogen.

36 MATERIALS SCIENCE↗

One-point fitting of the flux density produced by a heliostat

Accurate and simple models for the flux density reflected by an isolated heliostat should be one of the basic tools for the design and optimization of solar power tower systems. In this work, the ability and the accuracy of the Universidad de Zaragoza (UNIZAR) and the DLR (HFCAL) flux density models to fit actual energetic spots are checked against heliostat energetic images measured at Plataforma Solar de Almeria (PSA). Both the fully analytic models are able to acceptably fit the spot with only one-point fitting, i.e., the measured maximum flux. As a practical validation of this one-point fitting, the intercept percentage of the measured images, i.e., the percentage of the energetic spot sent by the heliostat that gets the receiver surface, is compared with the intercept calculated through the UNIZAR and HFCAL models. As main conclusions, the UNIZAR and the HFCAL models could be quite appropriate tools for the design and optimization, provided the energetic images from the heliostats to be used in the collector field were previously analyzed. Also note that the HFCAL model is much simpler and slightly more accurate than the UNIZAR model. (author)

14 SOLAR ENERGY↗

Absolute calibration of the radio astronomy flux density scale at 22 TO 43 GHz using Planck

The Planck mission detected thousands of extragalactic radio sources at frequencies from 28 to 857 GHz. Planck's calibration is absolute (in the sense that it is based on the satellite’s annual motion around the Sun and the temperature of the cosmic microwave background), and its beams are well characterized at sub-percent levels. Thus, Planck's flux density measurements of compact sources are absolute in the same sense. We have made coordinated Very Large Array (VLA) and Australia Telescope Compact Array (ATCA) observations of 65 strong, unresolved Planck sources in order to transfer Planck's calibration to ground-based instruments at 22, 28, and 43 GHz. The results are compared to microwave flux density scales currently based on planetary observations. Despite the scatter introduced by the variability of many of the sources, the flux density scales are determined to 1%–2% accuracy. At 28 GHz, the flux density scale used by the VLA runs 2%–3% ± 1.0% below Planck values with an uncertainty of ±1.0%; at 43 GHz, the discrepancy increases to 5%–6% ± 1.4% for both ATCA and the VLA.

79 ASTRONOMY AND ASTROPHYSICS↗

Series Solution for Magnetic Flux Density of Circular Current Loop and a Relevant Application

The series solution to the magnetic flux density of a circular current loop is presented in the paper. The convergences of these series are assessed. Comparing the result with elliptic integral method, the validity and feasibility of series solution were verified. A computer program has been developed by the method to calculate the magnetic flux density of a multi-coil magnet and its uniformity successfully.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DETECTION AND FLUX DENSITY MEASUREMENTS OF THE MILLISECOND PULSAR J2145–0750 BELOW 100 MHz

We present flux density measurements and pulse profiles for the millisecond pulsar PSR J2145–0750 spanning 37 to 81 MHz using data obtained from the first station of the Long Wavelength Array. These measurements represent the lowest frequency detection of pulsed emission from a millisecond pulsar to date. We find that the pulse profile is similar to that observed at 102 MHz. We also find that the flux density spectrum between ≈40 MHz to 5 GHz is suggestive of a break and may be better fit by a model that includes spectral curvature with a rollover around 730 MHz rather than a single power law.

79 ASTRONOMY AND ASTROPHYSICS↗

High density flux of Co nanoparticles produced by a simple gas aggregation apparatus

Gas aggregation is a well known method used to produce clusters of different materials with good size control, reduced dispersion, and precise stoichiometry. The cost of these systems is relatively high and they are generally dedicated apparatuses. Furthermore, the usual sample production speed of these systems is not as fast as physical vapor deposition devices posing a problem when thick samples are needed. In this paper we describe the development of a multipurpose gas aggregation system constructed as an adaptation to a magnetron sputtering system. The cost of this adaptation is negligible and its installation and operation are both remarkably simple. The gas flow for flux in the range of 60-130 SCCM (SCCM denotes cubic centimeter per minute at STP) is able to completely collimate all the sputtered material, producing spherical nanoparticles. Co nanoparticles were produced and characterized using electron microscopy techniques and Rutherford back-scattering analysis. The size of the particles is around 10 nm with around 75 nm/min of deposition rate at the center of a Gaussian profile nanoparticle beam.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced magnetic flux density mapping using coherent steady state equilibrium signal in MREIT

Measuring the z-component of magnetic flux density B = (B{sub x}, B{sub y}, B{sub z}) induced by transversally injected current, magnetic resonance electrical impedance tomography (MREIT) aims to visualize electrical property (current density and/or conductivity distribution) in a three-dimensional imaging object. For practical implementations of MREIT technique, it is critical to reduce injection of current pulse within safety requirements. With the goal of minimizing the noise level in measured B{sub z} data, we propose a new method to enhance the measure B{sub z} data using steady-state coherent gradient multi-echo (SSC-GME) MR pulse sequence combining with injection current nonlinear encoding (ICNE) method in MREIT, where the ICNE technique injects current during a readout gradient to maximize the signal intensity of phase signal including B{sub z}. The total phase offset in SSC-GME includes additional magnetic flux density due to the injected current, which is different from the phase signal for the conventional spoiled MR pulse sequence. We decompose the magnetization precession phase from the total phase offset including B{sub z} and optimize B{sub z} data using the steady-state equilibrium signal. Results from a real phantom experiment including different kinds of anomalies demonstrated that the proposed method enhanced B{sub z} comparing to a conventional spoiled pulse sequence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly-­laminated, high-­saturation-flux-­density, magnetic cores for on-­chip inductors in power converter applications

The objective of this project is development of a manufacturing process to realize thick highly-laminated metallic magnetic cores with suppressed eddy current losses for power applications and demonstration of integrated magnetic components using the process. The continual reduction in size and increase in functionality of portable electronic devices drives the development of ultracompact electrical power converters and therefore their associated inductors, which typically occupy the largest volume within the converter. This inductor size reduction can be achieved by increasing both the converter switching frequency as well as inductor operating flux density by utilizing appropriate magnetic core materials. Magnetically soft metallic alloys (e.g., NiFe and CoNiFe) are good core material candidates due to their superior magnetic properties (e.g., high saturation flux density and low coercivity) compared to conventional ferrite. However, to minimize eddy current losses, the core thickness is limited to the skin depth (typically less than 3 µm for 10 MHz operation); cores of this thickness are likely insufficient for handling high power (> 10W). Therefore, there is great interest in the development of highly-laminated metallic alloy cores with single lamination thickness in the sub-micron range to achieve suppressed eddy-current losses and high power handling capacity simultaneously. During the project, highly-laminated metallic alloy cores comprising up to 2000 layers of permalloy (Ni 80 Fe 20 ) or CoNiFe materials with single lamination thickness less than 1 µm have been fabricated based on automated multilayer electrodeposition technology compatible with CMOS manufacturing. The developed highly-laminated metallic cores preserve the high saturation flux density and low coercivity characteristics of metallic alloys, while suppressing eddy-current losses less than 1 W/cm3 at operation flux density of 0.5 T and frequency over 1 MHz. The developed highly-laminated metallic alloy cores have been further integrated into microfabricated windings to realize compact, on-chip inductors. Utilizing CMOS-compatible integration techniques, circular (toroid) and bar-shape (solenoid) microinductors have been fabricated exhibiting a constant inductance higher than 1 µH up to 50 MHz with peak quality factor as high as 35 at 5 MHz. The microfabricated inductor with highly-laminated core was tested in a power converter and demonstrated a converter efficiency of 93% at 5.5 MHz and 42 W under 100V input and 35V output operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Korean VLBI Network Calibrator Survey (KVNCS). 1. Source Catalog of KVN Single-dish Flux Density Measurement in the K and Q Bands

We present the catalog of the KVN Calibrator Survey (KVNCS). This first part of the KVNCS is a single-dish radio survey simultaneously conducted at 22 ( K band) and 43 GHz ( Q band) using the Korean VLBI Network (KVN) from 2009 to 2011. A total of 2045 sources are selected from the VLBA Calibrator Survey with an extrapolated flux density limit of 100 mJy at the K band. The KVNCS contains 1533 sources in the K band with a flux density limit of 70 mJy and 553 sources in the Q band with a flux density limit of 120 mJy; it covers the whole sky down to −32.°5 in decl. We detected 513 sources simultaneously in the K and Q bands; ∼76% of them are flat-spectrum sources (−0.5 ≤ α ≤ 0.5). From the flux–flux relationship, we anticipated that most of the radiation of many of the sources comes from the compact components. The sources listed in the KVNCS therefore are strong candidates for high-frequency VLBI calibrators.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a vector-tensor system to measure the absolute magnetic flux density and its gradient in magnetically shielded rooms

Several experiments in fundamental physics demand an environment of very low, homogeneous, and stable magnetic fields. For the magnetic characterization of such environments, we present a portable SQUID system that measures the absolute magnetic flux density vector and the gradient tensor. This vector-tensor system contains 13 integrated low-critical temperature (LTc) superconducting quantum interference devices (SQUIDs) inside a small cylindrical liquid helium Dewar with a height of 31 cm and 37 cm in diameter. The achievable resolution depends on the flux density of the field under investigation and its temporal drift. Inside a seven-layer mu-metal shield, an accuracy better than ±23 pT for the components of the static magnetic field vector and ±2 pT/cm for each of the nine components of the gradient tensor is reached by using the shifting method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗