Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUORINE 30”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A = 30

Evaluated spectroscopic data and level schemes from radioactive decay and nuclear reaction studies are presented for {sup 30}F, {sup 30}Ne, {sup 30}Na, {sup 30}Mg, {sup 30}Al, {sup 30}Si, {sup 30}P, {sup 30}S, and {sup 30}Cl. This evaluation for A=30 supersedes the previous evaluation 1998En04. However, some additional information for these nuclides can be found in earlier evaluations 1990En08 and 1978En02. Highlights of this publication are the following: The latest studies (2010StZZ, 2010De26) by fusion evaporation reaction of {sup 14}C and {sup 18}O using GAMMASPHERE array, consisted of 101 Compton-suppressed HPGe detectors, provided new data for {sup 30}Al, {sup 30}Si, and {sup 30}Mg nuclides and extended the level scheme to higher spin states. 2010Se07 reported a new level at 4814(3) keV for {sup 30}S nuclide studied by the {sup 32}S(p,t) reaction. It did not observe the 5168(6) keV level that was reported earlier as a possible doublet by 2007Ba69. In the absence of further experiment, 2010Se07 considers the level as one of the doublets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Highly Perfluorinated Covalent Triazine Frameworks Derived from a Low-Temperature Ionothermal Approach Towards Enhanced CO 2 Electroreduction

Perfluorinated covalent triazine frameworks (F-CTFs) have shown unique features and attractive performance in separation and catalysis. However, state-of-art F-CTFs synthesized via the ZnCl 2 -promoted procedure have quite low fluorine contents due to C-F bond cleavage induced by chloride (a Lewis base) and the harsh conditions deployed (400-700 °C). Fabricating F-CTFs with high fluorine contents (> 30 wt%) remains challenging. Herein, we present a low-temperature ionothermal approach (275 °C) to prepare F-CTFs, which is achieved via polymerization of tetrafluoroterephthalonitrile (TFPN) over the Lewis superacids, e.g., zinc triflimide [Zn(NTf 2 ) 2 ] without side reactions. With low catalyst loading (equimolar), F-CTFs are afforded with high fluorine content (31 wt%), surface area up to 367 m 2 g -1 , and micropores around 1.1 nm. The highly hydrophobic F-CTF-1 exhibits good capability to boost electroreduction of CO 2 to CO, with faradaic efficiency of 95.7% at –0.8 V and high current density (–141 mA cm -2 ) surpassing most of the metal-free electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-24: An Evaluation of the Stability of Image Quality Parameters of Varian On-Board Imaging (OBI) and EPID Imaging Systems

Purpose: Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the long term stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and the radiographic MV EPID mode. Methods: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For OBI CBCT, High quality head Full-Fan acquisition and Pelvis Half-Fan acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution, HU constancy and geometric distortion. Dose and kVp for the OBI were recorded using the Unfors RaySafe Xi system with the R/F High Detector for planar kV and the CT detector for CBCT. Dose for the MV EPID was recorded using a PTW975 Semiflex Ion Chamber, PTW Unidos electrometer and SolidWater™. Results: For each metric, values were normalized to the mean and the standard deviations were recorded. For the planar radiographic spatial resolution the f30, f40, f50 were 0.015, 0.008, 0.004 and 0.006, 0.009, 0.018 for the kV and MV, respectively. The standard deviation of the dose for kV was 0.010 and 0.005 for the MV. The standard deviations for Full and half fan were averaged together and the following standard deviations for each metric were recorded: 0.075(uniformity), 0.071(noise), 0.006(AP-Geometric Distortion), 0.005(LAT-Geometric Distortion), 0.058(mean slice thickness), 0.098(f30),0.101(f40),0.124(f50), 0.031(Lung/PMP-HU constancy), 0.063(Water/poly-HU constancy), 0.015(Bone/Derlin-HU constancy),0.006(Dose-Center), 0.004(Dose-Periphery). Using these, tolerances can be reported as a warning and action threshold of 1σ and 2σ. Conclusion: A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Varian OBI and EPID Imaging systems. The two systems show consistent imaging and dosimetric properties over the evaluated time frame.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-50: An Evaluation of the Stability of Image Quality Parameters of the Elekta XVI and IView Imaging Systems

Introduction Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the long term stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and MV mode. Methods and Materials: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For XVI CBCT, Head and Neck Small20 (S20) and Pelvis Medium20 (M20) standard acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution and HU constancy. Dose and kVp for the XVI were recorded using the Unfors RaySafe Xi system with the R/F Low Detector for the kV planar radiographic mode. Results A total of 20 and 10 measurements were acquired for the planar radiographic and CBCT systems respectively over a two month period. Values were normalized to the mean and the standard deviations (STD) were recorded. For the planar radiographic spatial resolution, the STD for f30, f40, f50 were 0.004, 0.002, 0.002 and 0.005, 0.007, 0.008 for the kV and MV, respectively. The average recorded dose for kV was 38.7±2.7 μGy. The STD of the evaluated metrics for the S20 acquisition were: 0.444(f30), 0.067(f40), 0.062(f50), 0.018(Water/poly-HU constancy), 0.028(uniformity) and 0.106(noise). The standard deviations for the M20 acquisition were: 0.108(f30), 0.073(f40), 0.091(f50), 0.008(Water/poly-HU constancy), 0.005(uniformity) and 0.005(noise). Using these, tolerances can be reported as a warning and action threshold of 1σ and 2σ. Conclusion A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Elekta XVI and iView imaging systems. Consistent imaging and dosimetric properties over the evaluated time frame were noted. This work was funded in part by the Cancer Prevention Research Institute of Texas Pre doctoral fellowship training grant (RP140105) to Dennis N. Stanley M.Sc.

60 APPLIED LIFE SCIENCES↗

Extended calculations with spectroscopic accuracy: Energy levels and transition properties for the fluorine-like isoelectronic sequence with Z = 24–30

We have performed extensive multiconfiguration Dirac–Hartree–Fock calculations and second-order many-body perturbation calculations for F-like ions with Z = 24–30. Energy levels and transition rates for electric dipole (E1), electric-quadrupole (E2), electric-octupole (E3), magnetic dipole (M1), and magnetic-quadrupole (M2) transitions, as well as radiative lifetimes, are provided for the lowest 200 levels belonging to the 1s{sup 2}2s{sup 2}2p{sup 5}, 1s{sup 2}2s2p{sup 6}, 1s{sup 2}2s{sup 2}2p{sup 4}3l, 1s{sup 2}2s2p{sup 5}3l, 1s{sup 2}2p{sup 6}3l, and 1s{sup 2}2s{sup 2}2p{sup 4}4l configurations of each ion. The results from the two sets of calculations are in excellent agreement. Extensive comparisons are also made with other theoretical results and observed data from the CHIANTI and NIST databases. The present energies and wavelengths are believed to be accurate enough to aid line identifications involving the n = 3 and n = 4 configurations, for which observations are largely missing. The calculated wavelengths and transition data will be useful in the modeling and diagnostics of astrophysical and fusion plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of photoanode thickness on electrochemical performance of dye sensitized solar cell

The thickness of photoanode is crucial as it adsorbed a large amount of dye molecules that provide electrons for generation of electricity in dye sensitized solar cell (DSC). Thus, in order to realize the practical application of DSC, study on various thickness of photoanode need to be carried out to analyze its effect on the electrochemical behavior of dye sensitized solar cell. To enhance the conversion efficiency, an additional layer of TiO{sub 2} using TiCl{sub 4} treatment was deposited prior to the deposition of the photoanode (active area of 1cm{sup 2}) with the thickness of 6, 12, 18, 24, and 30 µm on fluorine doped tin oxide (FTO) glass substrate. The resulting photoanode after the soak in N719 dye for more than 12hrs were used to be assembled in a test cell in combination with liquid electrolyte and counter electrode. The fabricated cells were characterized by solar simulator, ultraviolet-visible spectroscopy (UV-VIS), and electrochemical impedance spectroscopy (EIS). Scanning electron microscopy (SEM) was used to approximate the thickness of photoanode. An optimum power conversion efficiency of 4.54% was obtained for the cell fabricated with 18 µm photoanode thickness. This is attributed to the reduced resistance related to electron transport in the TiO{sub 2}/dye/electrolyte interface as proven by the EIS result. This led to the reduction of internal resistance, the increase in the electron life time and the improvement in the conversion efficiency.

36 MATERIALS SCIENCE↗

Suppression of Disorder in Benzamide and Thiobenzamide Crystals by Fluorine Substitution

Disorder is a common feature of molecular crystals that complicates determination of structures and can potentially affect electric and mechanical properties. Suppression of disorder is observed in otherwise severely disordered benzamide and thiobenzamide crystals by substituting hydrogen with fluorine in the ortho-position of the phenyl ring. Fluorine occupancies of 20–30% are sufficient to suppress disorder without changing the packing motif. Crystal structure prediction calculations reveal a much denser lattice energy landscape for benzamide compared to 2-fluorobenzamide, suggesting that fluorine substitution makes disorder less likely.

36 MATERIALS SCIENCE↗

Optimized molecular aggregation via incorporating fluorinated unit in the polymer donor for 17.3% efficiency organic solar cells

Regulating molecular aggregation state via chemical modification of photovoltaic materials to optimize the blend morphology is an effective and challenging strategy to improve the photovoltaic performance of organic solar cells (OSCs). Here, in this work, we demonstrate a random terpolymerization strategy by incorporating 1,3-bis(5-bromo-4-fluorothiophen-2-yl)-5,7-bis(2-ethylhexyl)-4H,8H-benzo[1,2-c:4,5-c']bisthiophene-4,8-dione (BFT, 30 mol%) unit with fluorinated π-bridges into the molecular backbone of PM6 and develop a terpolymer PF1. Benefiting from the strong electronegativity of fluorine atom and noncovalent interaction of F---S, the energy levels, molecular ordering, and aggregation properties of the polymer donors are precisely regulated. Notably, in the active layer film based on PF1: Y6, the π-π stacking distance can reduce to 3.51 Å, which is significantly smaller than that of PM6:Y6 (3.65 Å) and boosts the effective exciton dissociation and charge transport, thereby effectively optimize the photovoltaic properties of the related devices. As a result, the PF1:Y6-based OSCs achieved a power conversion efficiency (PCE) of up to 17.3%, which is much higher than that of the controlled OSCs based on PM6:Y6 (PCE = 16.2%). These results demonstrate high-efficiency OSCs enabled by regulating molecular aggregation via terpolymerization strategy.

14 SOLAR ENERGY↗

Electrolytes including fluorinated solvents for use in electrochemical cells

Provided are electrochemical cells and electrolytes used to build such cells. The electrolytes include ion-supplying salts and fluorinated solvents capable of maintaining single phase solutions with the salts at between about -30.degree. C. to about 80.degree. C. The fluorinated solvents, such as fluorinated carbonates, fluorinated esters, and fluorinated esters, are less flammable than their non-fluorinated counterparts and increase safety characteristics of cells containing these solvents. The amount of fluorinated solvents in electrolytes may be between about 30% and 80% by weight not accounting weight of the salts. Fluorinated salts, such as fluoroalkyl-substituted LiPF.sub.6, fluoroalkyl-substituted LiBF.sub.4 salts, linear and cyclic imide salts as well as methide salts including fluorinated alkyl groups, may be used due to their solubility in the fluorinated solvents. In some embodiments, the electrolyte may also include a flame retardant, such as a phosphazene or, more specifically, a cyclic phosphazene and/or one or more ionic liquids.

30 DIRECT ENERGY CONVERSION↗

Progress Towards Extended Cycle Life Si-based Anodes: Investigation of Fluorinated Local High Concentration Electrolytes

Silicon (Si) anodes are promising candidates for Li-ion batteries due to their high specific capacity and low operating potential. Implementation has been challenged by the significant Si volume changes during (de)lithiation and associated growth/regrowth of the solid electrolyte interphase (SEI). In this report, fluorinated local high concentration electrolytes (FLHCEs) were designed such that each component of the electrolyte (solvent, salt, diluent) is fluorinated to modify the chemistry and stabilize the SEI of high (30%) silicon content anodes. FLHCEs were formulated to probe the electrolyte salt concentration and ratio of the fluorinated carbonate solvents to a hydrofluoroether diluent. Higher salt concentrations led to higher viscosities, conductivities, and contact angles on polyethylene separators. Electrochemical cycling of Si-graphite/NMC622 pouch cells using the FLHCEs delivered up to 67% capacity retention after 100 cycles at a C/3 rate. Post-cycling X-ray photoelectron spectroscopy (XPS) analyses of the Si-graphite anodes indicated the FLHCEs formed a LiF rich solid electrolyte interphase (SEI). The findings show that the fluorinated local high concentration electrolytes contribute to stabilizing the Si-graphite electrode over extended cycling.

36 MATERIALS SCIENCE↗

Combinations of fluorinated solvents with imide salts or methide salts for electrolytes

Provided are electrochemical cells and electrolytes used to build such cells. The electrolytes include imide salts and/or methide salts as well as fluorinated solvents capable of maintaining single phase solutions at between about -30.degree. C. to about 80.degree. C. The fluorinated solvents, such as fluorinated carbonates, fluorinated esters, and fluorinated esters, are less flammable than their non-fluorinated counterparts and improve safety characteristics of cells containing these solvents. The amount of fluorinated solvents in electrolytes may be between about 30% and 80% by weight not accounting weight of the salts. Linear and cyclic imide salts, such as LiN(SO.sub.2CF.sub.2CF.sub.3).sub.2, and LiN(SO.sub.2CF.sub.3).sub.2, as well as methide salts, such as LiC(SO.sub.2CF.sub.3).sub.3 and LiC(SO.sub.2CF.sub.2CF.sub.3).sub.3, may be used in these electrolytes. Fluorinated alkyl groups enhance solubility of these salts in the fluorinated solvents. In some embodiments, the electrolyte may also include a flame retardant, such as a phosphazene, and/or one or more ionic liquids.

30 DIRECT ENERGY CONVERSION↗

Fluorocarbon assisted atomic layer etching of SiO{sub 2} and Si using cyclic Ar/C{sub 4}F{sub 8} and Ar/CHF{sub 3} plasma

The need for atomic layer etching (ALE) is steadily increasing as smaller critical dimensions and pitches are required in device patterning. A flux-control based cyclic Ar/C{sub 4}F{sub 8} ALE based on steady-state Ar plasma in conjunction with periodic, precise C{sub 4}F{sub 8} injection and synchronized plasma-based low energy Ar{sup +} ion bombardment has been established for SiO{sub 2} [Metzler et al., J. Vac. Sci. Technol. A 32, 020603 (2014)]. In this work, the cyclic process is further characterized and extended to ALE of silicon under similar process conditions. The use of CHF{sub 3} as a precursor is examined and compared to C{sub 4}F{sub 8}. CHF{sub 3} is shown to enable selective SiO{sub 2}/Si etching using a fluorocarbon (FC) film build up. Other critical process parameters investigated are the FC film thickness deposited per cycle, the ion energy, and the etch step length. Etching behavior and mechanisms are studied using in situ real time ellipsometry and x-ray photoelectron spectroscopy. Silicon ALE shows less self-limitation than silicon oxide due to higher physical sputtering rates for the maximum ion energies used in this work, ranged from 20 to 30 eV. The surface chemistry is found to contain fluorinated silicon oxide during the etching of silicon. Plasma parameters during ALE are studied using a Langmuir probe and establish the impact of precursor addition on plasma properties.

36 MATERIALS SCIENCE↗

Effect of Building Block Connectivity and Ion Solvation on Electrochemical Stability and Ionic Conductivity in Novel Fluoroether Electrolytes

Novel electrolytes are required for the commercialization of batteries with high energy densities such as lithium metal batteries. Recently, fluoroether solvents have become promising electrolyte candidates because they yield appreciable ionic conductivities, high oxidative stability, and enable high Coulombic efficiencies for lithium metal cycling. However, reported fluoroether electrolytes have similar molecular structures, and the influence of ion solvation in modifying electrolyte properties has not been elucidated. In this work, we synthesize a group of fluoroether compounds with reversed building block connectivity where ether moieties are sandwiched by fluorinated end groups. These compounds can support ionic conductivities as high as 1.3 mS/cm (30 °C, 1 M salt concentration). Remarkably, we report that the oxidative stability of these electrolytes increases with decreasing fluorine content, a phenomenon not observed in other fluoroethers. Using Raman and other spectroscopic techniques, we show that lithium ion solvation is controlled by fluoroether molecular structure, and the oxidative stability correlates with the “free solvent” fraction. Finally, we show that these electrolytes can be cycled repeatedly with lithium metal and other battery chemistries. Understanding the impact of building block connectivity and ionic solvation structure on electrochemical phenomena will facilitate the development of novel electrolytes for next-generation batteries.

36 MATERIALS SCIENCE↗

Atmospheric dust deposition on soils around an abandoned fluorite mine (Hammam Zriba, NE Tunisia)

The present study focuses on the eolian dispersion and dust deposition, of major and trace elements in soils in a semi-arid climate, around an old fluorite (CaF{sub 2}) and barite (BaSO{sub 4}) mine, located in Hammam Zriba in Northern Tunisia. Ore deposits from this site contain a high amount of metal sulphides constituting heavy metal pollution in the surrounding environment. Samples of waste from the surface of mine tailings and agricultural topsoil samples in the vicinity of the mine were collected. The soil samples and a control sample from unpolluted area, were taken in the direction of prevailing northwest and west winds. Chemical analysis of these solids was performed using both X-ray fluorescence and X-ray diffraction. To determine the transfer from mine wastes to the soils, soluble fraction was performed by inductively coupled plasma and ionic chromatography. The fine grained size fraction of the un-restored tailings, still contained significant levels of barium, strontium, sulphur, fluorine, zinc and lead with mean percentages (wt%) of 30 (calculated as BaO), 13 (as SrO), 10 (as SO{sub 3}), 4 (F), 2 (Zn) and 1.2 (Pb). Also, high concentrations of cadmium (Cd), arsenic (As) and mercury (Hg) were found with an averages of 36, 24 and 1.2 mg kg{sup −1}, respectively. As a result of the eolian erosion of the tailings and their subsequent wind transport, the concentrations of Ba, Sr, S, F, Zn and Pb were extremely high in the soils near to the tailings dumps, with 5%, 4%, 7%, 1%, 0.8% and 0.2%, respectively. Concentration of major pollutants decreases with distance, but they were high even in the farthest samples. Same spatial distribution was observed for Cd, As and Hg. While, the other elements follow different spatial patterns. The leaching test revealed that most elements in the mining wastes, except for the anions, had a low solubility despite their high bulk concentrations. According the 2003/33/CE Decision Threshold, some of these tailings samples were considered as hazardous. Furthermore, other waste samples, considered non hazardous, were not inert. In contrast, the SO{sub 4}{sup 2-}, Ba, Pb and Sb leachable contents measured in most of the soil samples were relatively high, exceeding the inert threshold for landfill disposal of wastes. - Highlights: • Tailings dumps and associated windblown materials contain high contaminants load. • Eolian dust arising from dumps dispersed pollutants and contaminated soils. • Contents of mining-related elements exceeded allowable concentrations by guideline. • The majority of harmful pollutants, except anions, have low leachable potential.

54 ENVIRONMENTAL SCIENCES↗

CO₂ Capture Membrane Process for Power Plant Flue Gas

Because the fleet of coal-fired power plants is of such importance to the nation's energy production while also being the single largest emitter of CO₂, the development of retrofit, post-combustion CO₂ capture technologies for existing and new, upcoming coal power plants will allow coal to remain a major component of the U.S. energy mix while mitigating global warming. Post-combustion carbon capture technologies are an attractive option for coal-fired power plants as they do not require modification of major power-plant infrastructures, such as fuel processing, boiler, and steam-turbine subsystems. In this project, the overall objective was to develop an advanced, hollow-fiber, polymeric membrane process that could be cost-effectively retrofitted into current pulverized coal-fired power plants to capture at least 90% of the CO₂ from plant flue gas with 95% captured CO₂ purity. The approach for this project tackled the technology development on three different fronts in parallel: membrane materials R&D, hollow-fiber membrane module development, and process development and engineering. The project team consisted of RTI (prime) and two industrial partners, Arkema, Inc. and Generon IGS, Inc. Two CO₂-selective membrane polymer platforms were targeted for development in this project. For the near term, a next-generation, high-flux polycarbonate membrane platform was spun into hollow-fiber membranes that were fabricated into both lab-scale and larger prototype (~2,200 ft²) membrane modules. For the long term, a new fluoropolymer membrane platform based on poly(vinylidene fluoride) [PVDF] chemistry was developed using a copolymer approach as improved capture membrane materials with superior chemical resistance to flue-gas contaminants (moisture, SO₂, NO x , etc.). Specific objectives were: - Development of new, highly chemically resistant, fluorinated polymers as membrane materials with minimum selectivity of 30 for CO₂ over N₂ and CO₂ permeance greater than 300 gas permeation units (GPU) targeted; - Development of next-generation polycarbonate hollow-fiber membranes and membrane modules with higher CO₂ permeance than current commercial polycarbonate membranes; - Development and fabrication of membrane hollow fibers and modules from candidate polymers; - Development of a CO₂ capture membrane process design and integration strategy suitable for end-of-pipe, retrofit installation; and - Techno-economic evaluation of the "best" integrated CO₂ capture membrane process design package In this report, the results of the project research and development efforts are discussed and include the post-combustion capture properties of the two membrane material platforms and the hollow-fiber membrane modules developed from them and the multi-stage process design and analysis developed for 90% CO₂ capture with 95% captured CO₂ purity.

20 FOSSIL-FUELED POWER PLANTS↗

A Fluorination Method for Improving Cation-Disordered Rocksalt Cathode Performance

In Li-rich cation-disordered rocksalt oxide cathodes (DRX), partial fluorine substitution in the oxygen anion sublattice can increase the capacity contribution from transition-metal (TM) redox while reducing that from the less reversible oxygen redox. To date, limited fluorination substitution has been achieved by introducing LiF precursor during the solid-state synthesis. To take full advantage of the fluorination effect, however, a higher F content is desired. In the present study, the successful use of a fluorinated polymeric precursor is reported to increase the F solubility in DRX and the incorporation of F content up to 10–12.5 at% into the rocksalt lattice of a model Li-Mn-Nb-O (LMNO) system, largely exceeding the 7.5 at% limit achieved with LiF synthesis. Higher F content in the fluorinated-DRX (F-DRX) significantly improves electrochemical performance, with a reversible discharge capacity of ≈255 mAh g –1 achieved at 10 at% of F substitution. After 30 cycles, up to a 40% increase in capacity retention is achieved through the fluorination. Overall, the study demonstrates the feasibility of using a new and effective fluorination process to synthesize advanced DRX cathode materials.

25 ENERGY STORAGE↗

Solvation dynamics of choline fluoride in ethylene glycol – Water mixtures

Due to their favorable physical properties, deep eutectic solvents (DESs) have been of interest in many applications in the energy and industry sectors. In this study, we investigate the new deep eutectic solvent ethalineF (a 1:2 M ratio of choline fluoride:ethylene glycol) and the effect of water addition on the solvation dynamics compared to the better known ethaline (a 1:2 M ratio of choline chloride:ethylene glycol). Femtosecond transient absorption spectroscopy and NMR diffusometry were used to study the solvation dynamics. 19 F NMR spectra were obtained for ethalineF solutions with different water additions. The 19 F NMR spectra show two fluorine signals; one can be assigned to fluoride anions solvated by EG and the other signal to fluoride anions associated with the much heavier and less mobile choline cation. Density, viscosity, conductivity, and E T (30) polarity measurements are also provided for ethalineF. The nuclear spin nature of fluorine atom permits to measure the self-diffusion coefficient of the negative ion in addition of the cation diffusion in a choline halide based deep eutectic solvent system. This allows to calculate the NMR-predicted conductivities σ NMR . The obtained ion dissociation coefficients α D at different water concentrations suggest a partial ion dissociation which was commensurate with the relatively low ion conductivity. Furthermore, the observed modest conductivity of ethalineF is explained in terms of ion association as well as the gradual increase in conductivity caused by the addition of water.

19F NMR↗

Determining concentration depth profiles in fluorinated networks by means of electric force microscopy

By means of electric force microscopy, composition depth profiles were measured with nanometric resolution for a series of fluorinated networks. By mapping the dielectric permittivity along a line going from the surface to the bulk, we were able to experimentally access to the fluorine concentration profile. Obtained data show composition gradient lengths ranging from 30 nm to 80 nm in the near surface area for samples containing from 0.5 to 5 wt. % F, respectively. In contrast, no gradients of concentration were detected in bulk. This method has several advantages over other techniques because it allows profiling directly on a sectional cut of the sample. By combining the obtained results with x-ray photoelectron spectroscopy measurements, we were also able to quantify F/C ratio as a function of depth with nanoscale resolution.

36 MATERIALS SCIENCE↗