Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: Theory, working principle, and static calibration

A novel fiber optic macro-bend based gas flowmeter for low flow rates is presented. Theoretical analysis of the sensor working principle, design, and static calibration were performed. The measuring system consists of: an optical fiber, a light emitting diode (LED), a Quadrant position sensitive Detector (QD), and an analog electronic circuit for signal processing. The fiber tip undergoes a deflection in the flow, acting like a cantilever. The consequent displacement of light spot center is monitored by the QD generating four unbalanced photocurrents which are function of fiber tip position. The analog electronic circuit processes the photocurrents providing voltage signal proportional to light spot position. A circular target was placed on the fiber in order to increase the sensing surface. Sensor, tested in the measurement range up to 10 l min{sup -1}, shows a discrimination threshold of 2 l min{sup -1}, extremely low fluid dynamic resistance (0.17 Pa min l{sup -1}), and high sensitivity, also at low flow rates (i.e., 33 mV min l{sup -1} up to 4 l min{sup -1} and 98 mV min l{sup -1} from 4 l min{sup -1} up to 10 l min{sup -1}). Experimental results agree with the theoretical predictions. The high sensitivity, along with the reduced dimension and negligible pressure drop, makes the proposed transducer suitable for medical applications in neonatal ventilation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Proposed Correlation for Critical Flow Rate of Steam/Water Flow

In the safety analysis of loss-of-coolant-accident (LOCA) and steam generator tube rupture (SGTR) scenarios of light water reactors, a modeling of a break is very important to predict the accident's result. For example, the design of a break simulator to simulate a LOCA in light water reactors requires accurate knowledge of the leakage flow through the break, whose shape can be assumed as an orifice or a nozzle according to the characteristics of the break shape. In the case of a small-break LOCA (SBLOCA) scenario, the critical flow mostly occurs by sub-cooled and saturated liquid water including a two-phase water flow at relatively high-pressure conditions. Among previous critical flow maps, Moody's maps are well known for their critical flow rate and pressure of a single component and two-phase mixture with respect to the upstream enthalpy and pressure. In Moody's model, a slip ratio defined by maximizing the critical flow rate with respect to the slip ratio was introduced, and thus its predictions tended to be too conservative. Later, Moody suggested other maps based on a homogeneous equilibrium model (HEM), and they were useful to predict a choked condition for a given upstream condition. However, their predictions of the critical flow rate seemed to show quite an underestimation compared to various test data. The author suggested more practicable critical flow maps for a critical mass flux and pressure of a steam-water flow with respect to the upstream stagnation conditions using an extended Henry-Fauske model. From a comparison with the selected test data, suggested maps showed conservative predictions within reasonable ranges. In this report, a new correlation for the critical flow rate was developed to simulate the suggested critical flow maps within a reasonable range of error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Semiempirical method of determining flow coefficients for pitot rake mass flow rate measurements

Flow coefficients applicable to area-weighted pitot rake mass flow rate measurements are presented for fully developed, turbulent flow in an annulus. A turbulent velocity profile is generated semiempirically for a given annulus hub-to-tip radius ratio and integrated numerically to determine the ideal mass flow rate. The calculated velocities at each probe location are then summed, and the flow rate as indicated by the rake is obtained. The flow coefficient to be used with the particular rake geometry is subsequently obtained by dividing the ideal flow rate by the rake-indicated flow rate. Flow coefficients ranged from 0.903 for one probe placed at a radius dividing two equal areas to 0.984 for a 10-probe area-weighted rake. Flow coefficients were not a strong function of annulus hub-to-tip radius ratio for rakes with three or more probes. The semiempirical method used to generate the turbulent velocity profiles is described in detail.

Trefny, C. J.↗

Measurement of flow angle and mass flow rate in an unknown flow field using hot film and hot wire probes

A data reduction technique applicable to constant temperature hot film and hot wire probes is presented which is used to determine flow angle and mass flow rate in an unknown flow field over a wide range of flow conditions at supersonic and hypersonic velocities. The technique virtually eliminates the effect of Reynolds number on a probe's flow angle sensitivity. Methods for extrapolating a limited amount of mass flow rate calibration data to include the range of mass flow rate encountered in an experiment are also given. This technique has been applied to data obtained using a hot film probe during surveys in the leeside flow field of a space shuttle orbiter configuration.

Helms, V. T., III↗

Low rate flow switch can be used for gas or liquid

Flow switch operable at low flow rates is used for detecting the flow of a water coolant in a vacuum deposition apparatus. This switch utilizes one or more reed switches which are actuated by a sliding magnet.

Bates, E. T., Jr.↗

Vacuum rated flow controllers for inert gas ion engines

Electrical propulsion systems which use a gas as a propellant require a gas flowmeter/controller which is capable of operating in a vacuum environment. The presently available instruments in the required flow ranges are designed and calibrated for use at ambient pressure. These instruments operate by heating a small diameter tube through which the gas is flowing and then sensing the change in temperature along the length of the tube. This temperature change is a function of the flow rate and the gas heat capacity. When installed in a vacuum, the change in the external thermal characteristics cause the tube to overheat and the temperature sensors are then operating outside their calibrated range. In addition, the variation in heat capacity with temperature limit the accuracy obtainable. These problems and the work in progress to solve them are discussed.

Pless, L. C.↗

Mass flow rate measurements in gas-liquid flows by means of a venturi or orifice plate coupled to a void fraction sensor

Two-phase flow measurements were carried out using a resistive void fraction meter coupled to a venturi or orifice plate. The measurement system used to estimate the liquid and gas mass flow rates was evaluated using an air-water experimental facility. Experiments included upward vertical and horizontal flow, annular, bubbly, churn and slug patterns, void fraction ranging from 2% to 85%, water flow rate up to 4000 kg/h, air flow rate up to 50 kg/h, and quality up to almost 10%. The fractional root mean square (RMS) deviation of the two-phase mass flow rate in upward vertical flow through a venturi plate is 6.8% using the correlation of Chisholm (D. Chisholm, Pressure gradients during the flow of incompressible two-phase mixtures through pipes, venturis and orifice plates, British Chemical Engineering 12 (9) (1967) 454-457). For the orifice plate, the RMS deviation of the vertical flow is 5.5% using the correlation of Zhang et al. (H.J. Zhang, W.T. Yue, Z.Y. Huang, Investigation of oil-air two-phase mass flow rate measurement using venturi and void fraction sensor, Journal of Zhejiang University Science 6A (6) (2005) 601-606). The results show that the flow direction has no significant influence on the meters in relation to the pressure drop in the experimental operation range. Quality and slip ratio analyses were also performed. The results show a mean slip ratio lower than 1.1, when bubbly and slug flow patterns are encountered for mean void fractions lower than 70%. (author)

42 ENGINEERING↗

Sensitivity of Flow and Sediment Transport in Meandering Rivers to Scale Effects and Flow Rate

Sensitivity of flow and sediment transport in a meandering river to variations in scaling and flow rate was studied. The FLUENT™ code was used for evaluating the river flow characteristics, including the mean velocity field and the Reynolds stress components, as well as for particle trajectory analysis. Particular attention was given to the sensitivity of the sedimentation patterns of different size particles in the river bend for various scales. Simulation studies were performed for both a model river and a physical river. The physical river was geometrically similar to the model river, with a scaling ratio of 1:100, but with identical Froude number. The flow and particle deposition patterns in the physical and model rivers were compared. It was shown that the mean flow quantities exhibit dynamic similarity, but the turbulence parameters and the particle sedimentation features in the physical river were different from the model. The secondary flows and particle transport patterns were also found to be sensitive to variation in the scale and flow rate.

54 ENVIRONMENTAL SCIENCES↗

An in situ imaging investigation of the effect of gas flow rates on directed energy deposition

Gas flow rates in Directed Energy Deposition (DED) Additive Manufacturing (AM) can significantly affect the quality of built parts by altering melt pool geometry. Using a DED process replicator and in situ synchrotron radiography, together with analogous experiments in an industrial DED machine, we investigate the impact of carrier gas and shield gas flow rates on build quality. The results reveal that there is a critical shield gas flow rate above which melt pools are flattened, tracks widen, and thus layer thickness decreases. The reduction in layer thickness is most prominent in conditions with low carrier gas flow rate, as the highly turbulent shield gas flow may divert slow moving powder particles away from the melt pool, decreasing capture efficiency. Very high flow rates increase internal porosity, as fast-moving particles impacting the melt pool surface can entrain chamber gas behind them. High gas flow rates also cool the melt pool, creating shallower melt pools with increased thermal gradients near the solidification front, increasing pore entrapment in the solidified track.

Additive manufacturing↗

Electromechanically Actuated Valve for Controlling Flow Rate

A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces. The inlet end (the right end as depicted in the figure) of the ball screw would be the main seating valve element: in the fully closed position, it would be pressed against the valve seat, as depicted in the upper part of the figure. A retainer would hold the valve seat in an inlet fitting. In addition, the retainer would be contoured to obtain a specified flow rate as a function of axial position of the ball screw. In the fully closed position, little force would be needed to press the ball screw against the seat because the push bore area upon which the upstream pressure would act would be small. The motor would position and hold the ball screw against the seat, providing the force necessary for sealing. To open the valve to a particular position, the motor would be commanded to rotate to a particular angular position (equivalently, a particular number of revolutions) at a particular rate of rotation within its torque limitations. Once the valve was open, fluid would flow through the inlet fitting and the chamber in the inlet housing, past the seat and its retainer, along the hollow core of the ball screw, and through the outlet housing and outlet fitting. The net force generated from fluid pressure in the open position would be small because the pressure exposed to the push bore areas at the inlet and outlet are nearly equal and the forces generated would be in opposing directions.

Patterson, Paul↗

High pressure flow-rate switch

Flow-rate switch adjusts easily over a wide switching range and operates uniformly over many cycles. It adapts easily to control of various fluids and has the possibility of introducing multi-point switching. Novel design features include the tapered spool, balanced porting, capillary-bypass lubrication, and capillary-restriction damping.

Gale, G. P.↗

Understanding the impact of flow rate and recycle on the conversion of a complex biorefinery stream using a flow-through microbial electrolysis cell

We investigated the effect of flow rate and recycle on the conversion of a biomass-derived pyrolysis aqueous phase in amicrobial electrolysis cell (MEC) to demonstrate production of renewable hydrogen in biorefinery. A continuous MEC operation was investigated under one-pass and recycle conditions usingthe complex, biomass-derived, fermentable, mixed substrate feed at a constant concentration of 0.026 g/L,while testing flow rates ranging from 0.19 to 3.6 mL/min. This corresponds to an organic loading rate (OLR) of 0.54₋10 g/L-day. Mass transfer issues observed at low flow rates were alleviated using high flow rates.Increasing the flow rate to 3.6 mL/min (3.7 min HRT) during one-pass operation increased the hydrogen productivity 3-fold, but anode conversion efficiency (ACE) decreased from 57.9% to 9.9%. Recycle of the anode liquid helped to alleviate kinetic limitations and the ACE increased by 1.8-fold and the hydrogen productivity by 1.2-fold compared to the one-pass condition at the flow rate of 3.6 mL/min (10 g/L-d OLR). High COD removal was also achieved under recycle conditions, reaching 74.2 1.1%, with hydrogen production rate of 2.92 ± 0.51 L/L-day. This study demonstrates the advantages of combining faster flow rates with a recycle process to improve rate of hydrogen production from a switchgrass-derived stream in the biorefinery.

08 HYDROGEN↗

Impact of the Number of Applied Current Meter Sensors on the Accuracy of Flow Rate Measurements across a Range of Hydroelectric Facilities Indicative of the Domestic Hydroelectric Fleet

The following paper represents the results of an investigation into the impact of the number and placement of Current Meter (CM) flow sensors on the accuracy to which they are capable of predicting the overall flow rate. Flow measurement accuracy is of particular importance in multiunit plants because it plays a pivotal role in determining the operational efficiency characteristics of each unit, allowing the operator to select the unit (or combination of units) which most efficiently meet demand. Several case studies have demonstrated that optimization of unit dispatch has the potential to increase plant efficiencies from between 1 to 4.4 percent [2] [3]. Unfortunately current industry standards do not have an established methodology to measure the flow rate through hydropower units with short converging intakes (SCI); the only direction provided is that CM sensors should be used. The most common application of CM is horizontally, along a trolley which is incrementally lowered across a measurement cross section. As such, the measurement resolution is defined horizontally and vertically by the number of CM and the number of measurement increments respectively. There has not been any published research on the role of resolution in either direction on the accuracy of flow measurement. The work below investigates the effectiveness of flow measurement in a SCI by performing a case study in which point velocity measurements were extracted from a physical plant and then used to calculate a series of reference flow distributions. These distributions were then used to perform sensitivity studies on the relation between the number of CM and the accuracy to which the flow rate was predicted. The following research uncovered that a minimum of 795 plants contain SCI, a quantity which represents roughly 12% of total domestic hydropower capacity. In regards to measurement accuracy, it was determined that accuracy ceases to increase considerably due to strict increases in vertical resolution beyond the application of 49 transects. Moreover the research uncovered that the application of 5 CM (when applied at 49 vertical transects) resulted in an average accuracy of 95.6% and the application of additional sensors resulted in a linear increase in accuracy up to 17 CM which had an average accuracy of 98.5%. Beyond 17 CM incremental increases in accuracy due to the addition of CM was found decrease exponentially. Future work that will be performed in this area will investigate the use of computational fluid dynamics to acquire a broader range of flow fields within SCI.

Flow Measurement↗

Dual-Flow-Rate Valve

Flow-control device precisely adjusted for two rates. Heart of twoposition valve is sliding poppet. At far-right position, poppet allows low flow. At far-left position, allows high flow. Valve supplies high-pressure gas at either of two preselected flow rates. Valve adjustable between 0.12 and 1.2 lb/s (0.054 and 0.54 kg/s) of hydrogen at 3,300 lb/in.2 (23 MN/m2) and 80 degrees F (27 degrees C). Two flow rates preadjusted between these limits in increments of 0.01 lb/s (0.0045 kg/s).

Allbritain, R. H.↗

Investigation of boron powder flow rates on real-time wall

The limit of boron flow rates for real-time conditioning of the first walls has been systematically investigated in the Experimental Advanced Superconducting Tokamak (EAST) with a full metal wall. Initially, solid boron injection demonstrated effective control over carbon impurities and deuterium recycling on the basis of pre-discharge boronization. A minimum flow rate, identified between 1.0 mg/s and 2.0 mg/s, was necessary for actively improving wall conditions under specific plasma operating scenarios, with this effect progressively enhancing as boron flow rates increased. Additionally, a maximum flow rate, estimated between 3.5 mg/s and 8.0 mg/s, was identified for these plasma conditions. When boron flow rates exceeded this maximum, boron-induced fueling effects influenced the plasma line-averaged density, and at excessively high flow rates, plasma disruption was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

NASA Discipline Cardiopulmonary↗