Resistance of The Flex-Wire Windings

In this paper, an analysis of the flexible printed circuit board (FPCB) windings is performed. A one-dimensional model of the flex-wire winding is introduced and an equation for the FPCB ac winding resistance is derived. Experimental verification of derived equations is performed, i.e., impedance and power loss measurements.

Wojda, Rafal↗

Sensitivity Analysis of Effectiveness of FLEX Strategies Using a CDF-Based Importance Measure Under Accident Conditions

One of the lessons learned from the Fukushima Daiichi nuclear power plant (NPP) accident is strengthening the station blackout (SBO) mitigation capabilities by enhancing defense in depth for all existing and new NPPs. One of the possible remedies is diverse and flexible coping strategies (FLEX). The objective of this study is to address the benefits of FLEX in various accident scenarios in terms of both risk and cost. FLEX was originally devised against SBO accidents. In this research, we investigate the fundamental plant responses against accidents considering two fundamentally different cases: accidents that lead to high pressure on the primary side and accidents that lead to low pressure on the primary side. Several uncertainties are associated with the characteristics of the FLEX portable equipment. Specifically, the time for FLEX deployment may depend on several factors such as type of accident, point of injection, availability of safety systems, battery backup timings, and human actions. This study utilizes a dynamic risk assessment framework to analyze accident scenarios and suggests a novel importance measure, which is a cumulative distribution function– based importance metric that characterizes the influence of input distribution on complete output distribution. The importance of the existing and newly developed FLEX strategy based on risk significance is illustrated with examples. The suggested measure provides clear insight into how FLEX affects risk of the whole system and additional risk margins thanks to new safety systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling FLEX Human Actions Using the EMRALD Dynamic Risk Assessment Tool

Most current efforts have modified and applied existing human reliability analysis (HRA) methods to treat human actions related to beyond-design-basis external events in which diverse and flexible coping strategies (FLEX) equipment would be deployed. However, many questions remain regarding the suitability of legacy HRA methods to address FLEX human actions, sparking the need for a new method of reasonably evaluating them. In this context, Idaho National Laboratory (INL) researched a relatively new approach to treating FLEX human actions via Event Modeling Risk Assessment Using Linked Diagrams (EMRALD) software. EMRALD was developed to support the increasing need for dynamic probabilistic risk assessment (PRA) models that can respond to evolving plant conditions during simulations. A couple benefits were identified when analyzing FLEX human actions through this software. In general, it is especially useful for evaluating a strategy’s feasibility, including FLEX human actions that require a relatively long time to perform. In this paper, we suggest how FLEX human actions can be modeled using the EMRALD software. Two different HRA modeling approaches using EMRALD are introduced: (1) procedure-based modeling and (2) PRA/HRA-based modeling. The former approach was introduced in the authors’ previous paper, whereas this paper mainly discusses how the latter approach works for an extended loss of AC power (ELAP) scenario with relevant procedures and PRA models. A hybrid method combining the two modeling approaches is introduced at the paper’s conclusion.

99 GENERAL AND MISCELLANEOUS↗

Multicriterion benefit evaluation methodology for safety enhancements in nuclear power plants and application for FLEX strategies

Here we propose a multicriterion benefit evaluation (MCBE) methodology for evaluating costs and benefits of implementing safety enhancements in nuclear power plants. The MCBE methodology establishes a comprehensive evaluation scope using multiple evaluation criteria (including public risk, occupational risk, plant revenue, and plant cost) and multiple contexts (including plant normal operations, incidents, and accidents). The MCBE methodology formulates a benefit or cost element as the product of a monetary consequence and its occurrence-likelihood change. The MCBE methodology also incorporates a decision maker’ preferences toward occurrence likelihood and monetary consequence into cost and benefit estimations through a modified usage of cumulative prospect theory. This paper applies the MCBE methodology to the implementation of diverse and flexible coping strategy (FLEX) in a generic nuclear power plant as an illustrative example. The FLEX benefits are evaluated through three types of influence paths: plant safety enhancement, risk-informed activities, and potential additional credit of FLEX in supporting plant operation and maintenance-efficiency improvement. The benefit-to-cost ratio (BCR) of FLEX implementation is calculated. Sensitivity analyses are conducted to examine the impacts of modeling assumptions and input parameter values on the BCR.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dynamic Probabilistic Risk Assessment Based Response Surface Approach for FLEX and Accident Tolerant Fuels for Medium Break LOCA Spectrum

After the Fukushima Daiichi Accident, the safety features such as accident tolerant fuel (ATF) and diverse and flexible coping strategies (FLEX) for existing nuclear fleets are being investigated by the US Department of Energy under the Light Water Reactor Sustainability Program. This research is being conducted to quantify the risk-benefit of these safety features. Dynamic probabilistic risk assessment (DPRA)-based response-surface approach has been presented to quantify the FLEX and ATF benefits by estimating the risk associated with each option. ATFs with multilayered silicon carbide (SiC), iron-chromium-aluminum, and chromium-coated zirconium cladding were considered in this study. While these ATF candidates perform better than the current zirconium cladding (Zr), they may introduce additional failure modes in some operating conditions. The fuel failure analysis modules (FAMs) were developed to investigate ATF performance. The dynamic risk assessments were performed using RAVEN, a DPRA tool, coupled with RELAP5 and FAMs. A cumulative distribution function-based index provided a mean of comparing the benefits of safety enhancements. For medium break loss of coolant accidents, FLEX operational timing window for each fuel type was estimated. Among these ATF candidates, SiC-type ATF was the most beneficial candidate for an increased safety margin than Zr-based fuel and was found to complement FLEX strategies in terms of risk and coping time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HP-FLEX MPC v0.1.0

HP-FLEX MPC is control software developed by Lawrence Berkeley National Laboratory with support from the California Energy Commission (CEC) through EPIC-19-301. HP-FLEX aims to provide load flexibility for heat pumps (HPs) in response to dynamic grid signals (including Time-of-Use, Dynamic Pricing, and Critical Peak Pricing) while maintaining thermostat temperatures within user-specified bounds. The software includes a system-identification module, which models the dynamics of the building envelope with thermostat data, and a control module based on a model predictive controller (MPC) to make optimal decisions. HP-FLEX receives forecasts of outdoor air temperature, solar irradiation, and internal gain (if available), as well as trajectories of energy price, temperature lower and upper bounds over a prediction horizon. It then optimizes heating and cooling capacities to minimize energy cost and peak power (with a user-defined weight on peak power) over the prediction horizon, while maintaining room air temperature within the temperature constraints, and outputs the optimal thermostat setpoints.

Kim, Donghun↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Innovation Flex Time

The authors examine the problem of how to provide a time code for staff to use in pursuit of innovation. Four potential options are explored ranging from not providing funds for this activity, to charging such efforts against existing or expanded program management and program development funds. One solution that provides funded time without raising laboratory overhead rates is identified and referred to as Innovation Flex Time. This would consist of capturing hours worked in excess of the standard work week but not charged to customers and making those hours available to fund time for exploring new ideas. A brief examination of labor relations laws, and laws regulating laboratory directed research and development suggests that Innovation Flex Time is a viable option for the laboratory. However, implementation of Innovation Flex Time would require NNSA approval and modification of the existing management and operations contract.

99 GENERAL AND MISCELLANEOUS↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Risk-Informed Analysis for Enhanced Resilient Nuclear Power Plant with Initiatives including ATF, FLEX, and Advanced Battery Technology

This report documents the activities performed by the Idaho National Laboratory (INL) during fiscal year (FY) 2021 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk-Informed Systems Analysis (RISA) Pathway, Enhanced Resilient Plant (ERP) Systems research. The purpose of the RISA Pathway research and development is to support plant owner-operator decisions with the aim to improve the economics, reliability, and maintain the high levels of safety of current nuclear power plants over periods of extended plant operations. The concept of ERP refers to the combinations of accident-tolerant fuel (ATF), optimal use of diverse and flexible coping strategy (FLEX), enhancements to plant components and systems, the incorporation of augmented or new passive cooling systems, the advanced battery technology with extended capacity, as well as improved fuel cycle efficiency. The objective of the ERP research effort is to use the RISA methods and toolkit in industry applications, including methods development and early demonstration of technologies, in order to enhance existing reactors? safety features and to substantially reduce operating costs through risk-informed approaches to plant design modifications to the plant and their characterization. The ERP R&D efforts in FY 2021 are focused on three industry initiatives, including accident-tolerant fuel (ATF), optimal use of diverse and flexible coping strategy (FLEX), and advanced battery technology with extended capacity.

99 GENERAL AND MISCELLANEOUS↗

FLEX-FUEL MIXING CONTROLLED COMBUSTION ENABLED BY PRECHAMBER IGNITION

There is an imminent need to displace fossil diesel fuel with cleaner burning, domestically produced, renewable fuels for use in heavy-duty engines. Bioethanol is a prime candidate as it widely adopted in the U.S. as a gasoline additive ranging in volume percentage from 10% (E10) up to 85% (E85). Direct substitution of market available ethanol-gasoline blends for diesel fuel is not plausible as the stark reactivity differences would not constitute the same ignition quality nor achieve auto-ignition at all. This work focuses on the development of prechamber enabled mixing-controlled combustion (PC-MCC) as an advanced combustion strategy to facilitate reliable ignition and diffusion style combustion ethanol-gasoline fuel blends. PC-MCC involves integration of an actively fueled prechamber (PC) into a conventional compression ignition combustion system. When ignited, the PC ejects hot turbulent jets into the main combustion chamber that then interact with the direct injected fuel, prompting immediate ignition. The PC jet flames provide a robust thermal ignition source that allows the engine to operate agnostic of fuel composition, or flex-fuel. Computational fluid dynamics (CFD) modeling was used to assess critical design features of the PC while garnering insights into the ignition strategies that facilitate robust performance. A key finding was the ignition performance benefits of fuel-rich PC operation which yield exothermic jets. Based on the numerical findings, a prototype igniter was tested experimentally on both single and multi-cylinder engine platforms at a variety of operating conditions. The experimental results indicate flex-fuel PC-MCC is well capable of diesel-like combustion processes by demonstrating matched or improved gross thermal efficiencies and load variability within 2%. Fuel grade ethanol (E98) exhibited consistently lower NOx and immeasurable soot across the load space. E98 also demonstrated a significant improvement in thermal efficiency at light loads.

Zeman, Jared↗

Numerical investigation of equivalence ratio effects on Flex-Fuel mixing controlled combustion enabled by prechamber ignition

There is interest in adapting renewable and low-carbon intensity fuels to heavy-duty engines to help displace criteria and greenhouse gas emissions associated with diesel combustion. Low-carbon fuels have inherently low cetane numbers and thus pose a significant challenge when considering direct substitution in diesel combustion systems. Use of an actively fueled prechamber as an ignition source to initiate mixing-controlled combustion (PC-MCC) of low-cetane fuels is becoming an attractive combustion mode to alleviate the identified reactivity deficit. This work focuses on the utilization of an active prechamber to facilitate diesel-like combustion of bioethanol-gasoline fuel blends in a heavy-duty engine. Recent results in this emerging technology suggest that ignition quality is uniquely coupled to prechamber equivalence ratio. In this numerical study, the fundamental implications of prechamber equivalence ratio on the ignition performance of direct injected fuels ranging from E10 to E100 are investigated using CONVERGE. Parametric studies of the prechamber operating strategy were assessed at diesel-like conditions to characterize the performance trends relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and achieves diesel-like ignition qualities and combustion processes for all fuels considered under stoichiometric and rich prechamber conditions. To characterize the equivalence ratio trends observed, a novel inflow boundary modeling technique was utilized to prescribe turbulent jets in place of the prechamber where selective speciation of the jet composition was conducted to isolate the ignition contributions of radical and reacting species in lean, stoichiometric, and rich jets. The inflow boundary modeling suggests that excess fuel and combustion intermediates present in jets produced from stratified and fuel-rich prechamber operation promotes higher jet temperatures and as such are superior ignition sources. Relative to a lean prechamber jet, the peak temperature of a reacting jet from a rich prechamber was up to 600 K hotter at fixed distances from the orifice exit. Furthermore, radicals also demonstrated an influence on the ignition process, but the combustion mode was identified to be thermally dominant.

33 ADVANCED PROPULSION SYSTEMS↗

Hygrothermal aging effects on polyimide and acrylate-based adhesive materials in high-performance flat-flex cable assemblies

Flat-flex assemblies are widely used across a diverse range of technologies, including consumer electronics, automotive systems, aerospace and defense applications, and medical devices, due to their compact form factor and flexibility. However, environmental stressors like temperature and humidity are known to degrade performance over time, though the main mechanisms for degradation remain unknown. Here, in this work, we examined the aging behavior of copper/polyimide/adhesive laminate systems under varying temperature and humidity conditions, focusing on material degradation and its effects on mechanical and dielectric properties. Results show that peel strength and breakdown voltage decrease with exposure time, temperature, and humidity; spectroscopic characterization revealed that the adhesive, and not the polyimide, is the weak link in the material stack-up. The adhesive, identified as a butyl acrylate-acrylonitrile (BA-AN) copolymer, exhibited age-related spectral changes that correlated with exposure severity and duration. Hydrolysis at BA ester and AN nitrile groups was identified as the primary degradation mechanism, producing amides, acids, and alcohols. We developed a mechanistic model that connects kinetic parameters for BA-AN spectral band decay to peel strength and breakdown voltage, and implicates hydrolysis at the AN moiety, not BA, in performance decrements. Modeling predictions at ambient conditions indicate faster decline in peel strength than dielectric strength at early times, followed by plateauing of both properties at longer times. These findings provide critical insights into laminate aging mechanisms and highlight the importance of addressing BA-AN degradation to improve the long-term reliability of these systems in high-humidity environments.

organic↗

Characterization of Flex-Fuel Prechamber Enabled Mixing-Controlled Combustion With Gasoline/Ethanol Blends at High Load

This numerical study focuses on the characterization of prechamber-enabled mixing-controlled combustion (PC-MCC) at ~18 bar brake mean effective pressure (BMEP) and 2200 rpm with 10% by volume ethanol-gasoline blend (E10) and pure ethanol (E100). Computational fluid dynamic (CFD) simulations of a stock and prechamber retrofitted single-cylinder Caterpillar C9.3B are carried out using CONVERGE. Prechamber equivalence ratio at spark timing, prechamber spark timing advance, and main chamber injection strategy are assessed with respect to their impact on ignition assistance performance and emissions characteristics relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and operates well for both E10 and E100 at the operating conditions considered. The results demonstrate that the use of a pilot-main injection strategy enables spark timing in the prechamber to be advanced and thus reduces spark plug firing pressure while maintaining robust ignition assistance. Results also indicate that the rich prechamber operation is favored for improved ignition assistance capabilities. Furthermore, the findings of this work suggest that a heavy-duty vehicle using a PC-MCC engine can utilize any blend of gasoline and ethanol, up to including pure ethanol, with no major sacrifices in performance relative to the diesel engine.

33 ADVANCED PROPULSION SYSTEMS↗

Broadband polarization-entangled source for C+L-band flex-grid quantum networks

The rising demand for transmission capacity in optical networks has motivated steady interest in expansion beyond the standard C-band (1530–1565 nm) into the adjacent L-band (1565–1625 nm) for an approximate doubling of capacity in a single stroke. However, in the context of quantum networking, the L-band has yet to be fully leveraged with the suite of advanced tools for characterization and management available from classical lightwave communications. In this work, we demonstrate an ultrabroadband two-photon source integrating both C- and L-band wavelength-selective switches for complete control of spectral routing and allocation across 7.5 THz in a single setup. Polarization state tomography of all 150 pairs of 25-GHz-wide channels reveals an average fidelity of 0.98 and total distillable entanglement greater than 181 kebits/s. This source is explicitly designed for flex-grid optical networks and can facilitate optimal utilization of entanglement resources across the full C+L-band.

42 ENGINEERING↗

Development of a Flex-Fuel Mixing Controlled Combustion System for Gasoline/Ethanol Blends Enabled by Prechamber Ignition

This project demonstrated a heavy-duty engine converted from using diesel fuel to a flex-fuel engine that can use any blend of gasoline and ethanol. The combustion system is an innovative concept that allows very low cetane fuels to be used in a conventional mixing-controlled combustion (MCC) strategy without auxiliary heating, changes to the basic engine structure, or advanced controls.

09 BIOMASS FUELS↗

Flexible Financial Credit Agreements: Low-Interest Secured Flex Loans (LISFL)

Flexible Financial Credit Agreements is a broad term used to describe a suite of solar products with innovative features not currently offered in traditional solar financing programs. This brief focuses on a flex loan program that offers a no- or low-cost capital source to bridge the gap between the initial installation cost and the ultimate receipt of tax credits and energy savings. This program also provides low interest rates, for affordability, as well as a pre-funded debt service reserve account (DSRA), and is secured by the solar PV asset.