Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FISSION NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Expansion of the surrogate method to measure the prompt fission neutron multiplicity for Pu 241 [Prompt Fission Neutron Multiplicity for Pu-241 using the Surrogate Method]

Fission neutron multiplicity data are imperative for nuclear models that support criticality safety, nuclear nonproliferation, and stockpile stewardship. This work presents the first experimental measurement to determine the average neutron multiplicity ($\bar{ν}$) and the neutron multiplicity distribution using a surrogate reaction. 241 Pu has a short half-life of 14.3 yr. To circumvent experimental difficulties, inelastic scattering of 53.96-MeV α particles on 242 Pu served as a surrogate for 241 Pu (n , f). The present text reports and discusses the average neutron multiplicity, in addition to the neutron multiplicity moments and distribution for equivalent neutron energies up to 20 MeV. Finally, the $\bar{ν}$ measured in this experiment agrees with previous measurements until 12 MeV, where discrepancies arise due to preequilibrium neutron emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved fission neutron energy discrimination with 4 He detectors through pulse filtering

Our paper presents experimental and computational techniques implemented for 4 He gas scintillation detectorsfor inducedfission neutron detection. Fission neutrons are produced when natural uranium samples are activelyinterrogated by 2.45 MeV deuterium-deuterium fusion reaction neutrons. Fission neutrons of energies greaterthan 2.45 MeV can be distinguished by their different scintillation pulse height spectra since 4 He detectorsretain incident fast neutron energy information. To enable the preferential detection of fast neutrons up to10 MeV and suppress low-energy event counts, the detector photomultiplier gain is lowered and triggerthreshold is increased. Pile-up and other unreliable events due to the interrogating neutronflux and backgroundradiation arefiltered out prior to the evaluation of pulse height spectra. With these problem-specific calibrationsand data processing, the 4 He detector's accuracy at discriminatingfission neutrons up to 10 MeV is improvedand verified with 252 Cf spontaneousfission neutrons. Given the 4 He detector's ability to differentiate fastneutron sources, this proof-of-concept active-interrogation measurement demonstrates the potential of specialnuclear materials detection using a 4 He fast neutron detection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of prompt fission neutron spectrum for spontaneous fission of Cf 252 using γ multiplicity tagging

The prompt fission neutron spectrum from spontaneous fission of 252 Cf is an integral part of several aspects of nuclear data. Not only is the spectrum itself of interest, but neutron detectors often use the spectrum for calibration, and other prompt fission neutron spectra are measured as a ratio to 252 Cf. Therefore, reducing the uncertainties in this spectrum will allow for more accurate nuclear data to be available across a wide range of fields. The prompt fission neutron spectrum for the spontaneous fission of 252 Cf was measured at Rensselaer Polytechnic Institute using the multiple γ tagging method with a 18.4-ng fission sample. An EJ-301 liquid scintillator fast neutron detector was used to measure the high energy portion of the spectrum, 0.5–7 MeV, and a thin EJ-204 plastic scintillator was used to measure the low energy portion of the spectrum, from 50 keV to 2 MeV. These spectra both show good agreement with the current evaluation of 252 Cf and have low associated uncertainties providing a new high precision measurement that helps reduce the uncertainties in the prompt fission neutron spectrum for the spontaneous fission of 252 Cf.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlated Production and Analog Transport of Fission Neutrons and Photons Using Fission Models FREYA, FIFRELIN, and the Monte Carlo Code TRIPOLI-4

Fission modeling in general-purpose Monte Carlo transport codes often relies on average nuclear data provided by the international evaluation libraries. As such, only average fission multiplicities are available and correlations between fission neutrons and photons are missing. Whereas uncorrelated fission physics is usually sufficient for standard reactor core and radiation shielding calculations, correlated fission secondaries are required for specialized nuclear instrumentation and detector modeling. For coincidence counting detector optimization for instance, the precise simulation of fission neutrons and photons that remain correlated in time from birth to detection is essential. New developments were recently integrated into the Monte Carlo transport code TRIPOLI-4 to model fission physics more precisely, the purpose being to access event-by-event fission events from two different fission models: Fission Reaction Event Yield Algorithm (FREYA) and Fission Fragment Evaporation Leading to an Investigation of Nuclear Data (FIFRELIN). TRIPOLI-4 simulations can now be performed, either by connecting via an application programming interface to the Lawrence Livermore National Laboratory fission library including FREYA, or by reading the external fission event data files produced by FIFRELIN beforehand. These new capabilities enable us to easily compare results from the Monte Carlo transport calculations using the two fission models in a nuclear instrumentation application. In the first part of this paper, the broad underlying principles of the two fission models are recalled. We then present the experimental measurements of neutron angular correlations for 252 Cf(sf) and 240 Pu(sf). The correlations were measured for several neutron kinetic energy thresholds. In the latter part of this paper, simulation results are compared with the experimental data. Spontaneous fissions in 252 Cf and 240 Pu are modeled by FREYA or FIFRELIN. Emitted neutrons and photons are subsequently transported to an array of scintillators by TRIPOLI-4 in the analog mode to preserve their correlations. Angular correlations between fission neutrons obtained independently from these TRIPOLI-4 simulations, using either FREYA or FIFRELIN, are compared with the experimental results. In conclusion, for 240 Pu(sf), the measured correlations were used to tune one of the FREYA model parameters. Similarly, different sets of parameters have been tested in FIFRELIN to try to improve the agreement with the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preequilibrium Asymmetries in the Pu 239 ( n , f ) Prompt Fission Neutron Spectrum

The physical properties of neutrons emitted from neutron-induced fission are fundamental to our understanding of nuclear fission. However, while state-of-the-art fission models still incorporate isotropic fission neutron spectra, it is believed that the preequilibrium prefission component of these spectra is strongly anisotropic. The lack of experimental guidance on this feature has not motivated incorporation of anisotropic neutron spectra in fission models, though any significant anisotropy would impact descriptions of a fissioning system. In the present work, an excess of counts at high energies in the fission neutron spectrum of 239 Pu is clearly observed and identified as an excess of the preequilibrium prefission distribution above the postfission neutron spectrum. This excess is separated from the underlying postfission neutron spectrum, and its angular distribution is determined as a function in incident neutron energy and outgoing neutron detection angle. Comparison with neutron scattering models provides the first experimental evidence that the preequilibrium angular distribution is uncorrelated with the fission axis. The results presented here also impact the interpretation of several influential prompt fission neutron spectrum measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 235 U prompt fission neutron spectrum measured by the Chi-Nu project at LANSCE

The Chi-Nu experiment aims to accurately measure the prompt fission neutron spectrum for the major actinides. At the Los Alamos Neutron Science Center (LANSCE), fission can be induced with neutrons ranging from 0.7 MeV and above. Using a two arm time-of-flight (TOF) technique, the fission neutrons are measured in one of two arrays: a 22- 6 Li glass array for lower energies, or a 54-liquid scintillator array for outgoing energies of 0.5 MeV and greater. Presented here are the collaboration's preliminary efforts at measuring the 235 U PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Re-evaluating the prompt fission neutron spectrum of spontaneously fissioning 252 Cf

The prompt fission neutron spectrum (PFNS) of spontaneously fissioning 252 Cf is a Neutron Data Standards observable. Nearly all fission spectra of actinides were measured relative to it, using efficiencies derived from it, or analyzed with simulations validated by it. The current Standards evaluation was published by W. Mannhart in 1987. It could not be updated because the evaluation input, experimental mean values and covariances, were lost. First, we attempt to reproduce it. However, Mannhart’s evaluation can only be reproduced within its one-σ uncertainties as some of its aspects (e.g., experimental covariances, rejected data points) remain unknown. Therefore, a new evaluation is presented: We revisit all existing experimental 252 Cf(sf) PFNS data, including those published after the release of the current Standards evaluation, and re-estimate associated covariances. The newly evaluated 252 Cf(sf) PFNS differs distinctly from Mannhart’s below 300 keV and extends it to lower and higher outgoing neutron energies (500 eV–25 MeV). The new evaluated uncertainties are larger from 3–9 MeV and smaller otherwise. Spectrum averaged cross sections of importance to the International Reactor Dosimetry and Fusion File community calculated with the new spectrum are close to those calculated with Mannhart’s evaluation and agree with experimental values well within their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Producing Evaluation-quality 239 Pu Average Prompt Fission Neutron Multiplicities using a Correlated Fission Model

An evaluation of the average prompt fission neutron multiplicity, $\bar{ν}_p$, of 239 Pu(n,f) is shown. This evaluation includes (a) the correlated fission model CGMF, and (b) a detailed analysis of past and recently published experimental data. Using CGMF-calculated $\bar{ν}_p$ as prior enables to link, through the use of evaluated model input parameters, $\bar{ν}_p$ to other fission observables such as the prompt fission neutron spectrum (PFNS), preneutron emission fission yields as a function of mass, and the average total kinetic energy of the fragments. These evaluated parameters produce realistic predictions of many fission observables, while the evaluated $\bar{ν}_p$ agrees well (χ 2 ≈ 1) with data. Moreover, with the new evaluated $\bar{ν}_p$, the effective neutron multiplication factor of fast Pu ICSBEP critical assemblies are predicted with a mean bias of 58 pcm compared to 18 pcm with ENDF/B-VIII.0, when paired with a new 239 Pu PFNS and fission cross section. Due to these encouraging validation results, the evaluated $\bar{ν}_p$ is currently part of a release candidate for the 239 Pu ENDF/B-VIII.1 file. Hence, a correlated fission model was used for the first time for evaluating $\bar{ν}_p$ that is of evaluation quality. This is an important step towards consistent evaluations of prompt fission observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Errors introduced in fission neutron spectrum measurements using a single reference

Measurements of physical quantities are often made relative to a reference quantity, simplifying the interpretation of the measurement and its uncertainties. However, if applied without careful considerations, this technique can carry with it a significant and complex systematic error that is usually ignored. For example, measurements of continuous neutron spectra relative to a reference spectrum yield a result that does not properly include the important effects of neutron scattering in the experimental environment. These effects act to distort the measured spectrum shape and create notable errors in spectrum-integrated quantities. While this effect is one of a series of known potential sources of systematic error including, but not limited to target impurities, angular distributions, incident beam flux, and others, the error introduced from differences in environmental scattering effects between the reference and desired spectra are frequently overlooked. In this work, we demonstrate the origin of this error using simulated data corresponding to measurements of the neutron-induced prompt fission neutron spectra of 233 U, 235 U, 238 U, and 239 Pu as well as the spontaneous fission neutron spectrum of 252 Cf. Errors in the spectrum shape can be as high as 10%–15% depending on the combination of incident and outgoing neutron energy. The spectrum integral and average spectrum energy also contain errors that change with incident neutron energy and can be as high as ~2%. Although this study is based on simulated data, we also show a method for proving that this error exists in an experimental data set and we show a correction that can be applied to results of this type to obtain a more accurate result, thereby largely removing systematic errors from environmental scattering effects. The potential for these kinds of errors should be considered in measurements producing continuous neutron spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chi-Nu measurements of the prompt fission neutron spectrum of {sup 235}U and {sup 239}Pu - 25581

Knowledge of the prompt fission neutron spectrum is crucial for understanding the behavior of energetic nuclear systems. Although this energy spectrum has been measured for the major actinides {sup 235}U and {sup 239}Pu for decades, the majority of the available literature data lack the coverage of both incident and outgoing neutron energies and the precision required to accurately guide evaluations and fission models. The Chi-Nu experiment is designed to measure the prompt fission neutron spectrum for a wide range of incident and outgoing neutron energies with attention to uncertainty estimation and assessment of systematic errors in order to provide reliable guidance for evaluations and models of nuclear fission. Preliminary results of the prompt fission neutron spectrum from the neutron-induced fission of {sup 235}U and {sup 239}Pu are presented here, with a focus on the presence of spectral features near multi-chance fission thresholds, pre-equilibrium neutrons in the deduced spectrum, and also on trends of the mean fission neutron energy as a function of the incident neutron energy. While the mean energies of from ENDF/B-VIII.0 are in good agreement with those reported for {sup 235}U spectra, significant disagreements exist above an incident neutron energy of approximately 13 MeV for {sup 239}Pu. Furthermore, in general, the physics features regarding multi-chance fission and pre-equilibrium neutron emission newly-introduced into ENDF/B-VIII.0 appear provide an improved description of the data as compared to ENDF/B-VII.1. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of the Prompt Fission Neutron Spectrum at LANSCE: The Chi-Nu Experiment

The goal of the Chi-Nu experiment at the Los Alamos Neutron Science Center is to measure the prompt fission neutron spectra from major actinides using a double time-of-flight method with a pulsed, white incoming neutron source. Fission events are detected with a parallel-plate avalanche counter and outgoing neutrons are detected with either a 6 Li-glass or liquid scintillator detector array for low- or high-energy neutrons, respectively. A detector response matrix for the interaction of neutrons with the experimental environment for neutrons measured with the Chi-Nu 6 Li-glass detector array has been calculated to obtain a full understanding of the measured Chi-Nu data and also to allow for nearly instantaneous production of simulated Chi-Nu data spectra. Prompt fission neutron spectra corresponding to 19 incoming neutron energy ranges from 0.7-20 MeV have been extracted using the ratio-of-ratios method with Chi-Nu 6 Li-glass data on the neutron-induced fission of 235 U.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of nonstatistical properties in nuclear structure on emission of prompt fission neutrons

We report the Hauser-Feshbach fission-fragment decay (HF 3 D) model is extended to calculate the prompt fission neutron spectrum (PFNS) for the thermal-neutron-induced fission on 235 U, where the evaporated neutrons from all possible fission-fragment pairs are aggregated. By studying model parameter sensitivities on the calculated PFNS as well as nonstatistical behavior of low-lying discrete level spin distribution, we conclude that discrepancies between the aggregation calculation and the experimental PFNS seen at higher neutron emission energies can be attributed to both the primary fission-fragment yield distribution and the possible high spin states that are not predicted by the statistical theory of nuclear structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Prompt Fission Neutron Spectrum of 235 U(n,f) below 2.5 MeV for Incident Neutrons from 0.7 to 20 MeV

New prompt fission neutron spectrum measurements are reported for 235 U(n,f) reactions induced by neutrons with energies from 0.7 to 20 MeV. These measurements cover outgoing neutron energies from 2.5 MeV down to 10 keV, using an array of 6 Li-glass scintillators for neutron detection and a double time-of-flight technique. The neutrons were produced at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. A detailed MCNP ® model of the experimental equipment and the surrounding room was used to interpret the experimental results. Backgrounds were measured in situ, making use of the time-dependent singles rates of the various detectors with asynchronous readout from waveform digitizers. The results presented here have been included in a re-evaluation of the fission neutron spectra for this fissioning system, a description of which is presented elsewhere in this issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 239 Pu$(n, f$) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy 1–20 MeV

Although the prompt fission neutron spectrum (PFNS) is an essential component of neutron-driven systems that has been measured for decades, there are still multiple glaring unknowns regarding the PFNS of major actinides in the fission neutron incident energy range, specifically with regard to multichance fission and pre-equilibrium neutron emission processes. The only impactful experimental 239 Pu PFNS measurements included in recent nuclear data evaluations were measured over a limited outgoing neutron energy range at thermal and 1.5-MeV average incident neutron energy, while other potentially impactful measurements have been shown to contain errors that resulted in either large uncertainty increases or in complete exclusion from nuclear data evaluation. Here, we report a measurement of the 239 Pu PFNS over a wide range of incident neutron energy (1–20 MeV) and three orders of magnitude in outgoing neutron energy (0.01–10 MeV) resulting from the Chi-Nu experiment at the Los Alamos Neutron Science Center. These results are the combination of separate PFNS measurements in the same experimental area, one using a Li-glass and the other a liquid scintillator detector array. Covariances between all PFNS data points from each detector and within each incident energy range were generated between all other data in both detector arrays and within all other incident neutron energy bins, yielding a single covariance matrix for all 1300 PFNS data points reported here. These covariances are based on a thorough assessment of systematic bias and uncertainties associated with the measurement, PFNS extraction technique, combination of data from each detector type, and other aspects of the analysis. The existence of covariances between PFNS data points in different incident neutron energy ranges yielded covariances between average PFNS energy values at each incident energy to be reported here as well, which allowed for firm statements to be made regarding a shape of a purely experimental mean PFNS energy trend for the first time. Although minor PFNS shape differences exist between the results reported here and recent nuclear data evaluations, the ENDF/B-VIII.0 and JEFF-3.3 PFNS evaluations agree reasonably well with the present results from 1-to 10-MeV incident neutron energy, which spans the well-measured 1.5-MeV incident neutron energy PFNS from Lestone and Shores as well as the onset of second-chance fission. However, while the pre-equilibrium component of the PFNS above 12-MeV incident neutron energy roughly agrees in position and magnitude with ENDF/B-VIII.0 and JEFF-3.3, clear differences relating to the relative magnitude of third-chance fission PFNS features are present in the PFNS shape and in the mean PFNS energy trends.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 252 Cf ⁢(sf) prompt fission neutron spectrum utilizing 12 C ⁡(𝑛, 𝑛) and 9 Be ⁢(𝑛, 𝑛) neutron scattering reference measurements

The 252 Cf spontaneous fission (sf), prompt fission neutron spectrum (PFNS) is a fundamental quantity for nuclear physics measurements of neutron-emitting reactions. This energy distribution of neutrons emitted from fission has been considered a neutron data standard for decades and has been utilized as a reference for neutron detection efficiency, validation of Monte Carlo simulations, benchmarking of dosimetry standards, and more. A significant portion of the global collection of nuclear data on neutron-induced reactions is correlated with the 252 Cf ⁢(sf) PFNS. Despite the reliance on this quantity by the nuclear physics community, the historical collection of 252 Cf PFNS measurements display systematic disagreements that are not understood or easily explained. These experimental discrepancies could potentially bias the 252 Cf PFNS Standard evaluation. On top of this, these past experiments frequently employed correlated experimental measurement or analysis methods. The artificial intelligence (AI)/machine learning (ML)-informed californium chi-nuclear data experiment (AIACHNE) project was formed to (a) investigate these discrepancies utilizing AI/ML methods to identify outlying regions of literature data, assign these regions to features of the experiment itself, and perform an improved evaluation of the 252 Cf PFNS and (b) perform a new experimental measurement of this quantity designed to improve upon the existing literature database. Here, in this work, we report on the AIACHNE 252 Cf PFNS experiment utilizing a new analysis method uncorrelated with all previous measurements: neutron efficiency determinations based on elastic neutron scattering on 12 C and 9 Be . This new method provides an independent test of the existing literature data and evaluation of the 252 Cf ⁢(sf) PFNS. The method is described with detailed covariance quantification procedures, as well as a direct discussion of the sources of uncertainty described as requirements in the “Templates” series of papers. The 252 Cf ⁢(sf) PFNS reported in this work agrees well with the overall shape of the existing standard PFNS evaluation as well as many literature measurements, thus verifying the current evaluation utilizing new techniques. However, the results suggest that there are deficiencies in the angle-differential 12 C and 9 Be ⁢(𝑛, 𝑛) evaluated nuclear data, which produce unphysical structures in the reported result. While these structures are relatively minor, they become obvious because of the high statistical precision of the data and the expected smooth continuity of the 252 Cf ⁢(sf) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗