At least 19 records

Degradation of Photovoltaic Modules Under High Voltage Stress in the Field: Preprint

The degradation in performance for eight photovoltaic (PV) modules stressed at high voltage (HV) is presented. Four types of modules--tandem-junction and triple-junction amorphous thin-film silicon, plus crystalline and polycrystalline silicon modules--were tested, with a pair of each biased at opposite polarities. They were deployed outdoors between 2001 and 2009 with their respective HV leakage currents through the module encapsulation continuously monitored with a data acquisition system, along with air temperature and relative humidity. For the first 5 years, all modules were biased continuously at fixed 600 VDC, day and night. In the last 2 years, the modules were step-bias stressed cyclically up and down in voltage between 10 and 600 VDC, in steps of tens to hundreds of volts. This allowed characterization of leakage current versus voltage under a large range of temperature and moisture conditions, facilitating determination of leakage paths. An analysis of the degradation is presented, along with integrated leakage charge. In HV operation: the bulk silicon modules degraded either insignificantly or at rates of 0.1%/yr higher than modules not biased at HV; for the thin-film silicon modules, the added loss rates are insignificant for one type, or 0.2%/yr-0.6%/yr larger for the other type.

14 SOLAR ENERGY↗

Correlation of Qualification and Accelerated Testing with Field Degradation

Qualification testing of solar photovoltaic (PV) modules per IEC 61215 standard encompasses a set of well-defined accelerated stress tests (irradiation, environmental, mechanical and electrical) with strict pass/fail criteria based on functionality/performance, electrical and mechanical safety, and visual requirements. The qualification testing does not identify all the possible reliability failures or durability issues witnessed in the actual field. However, it does identify the major/catastrophic design quality issues (infant mortality), which could occur early in a module’s field life. Unfortunately, in the industry, there is no consensus-based standard or protocol available to validate manufacturers’ warranty period claims based on the end-of-life wear-out failure mechanisms. Being able to predict the field degradation rates and lifetime using mode-specific accelerated tests on moderately field-aged modules, for example 10 years, for certain commonly occurring degradation modes would be a powerful contribution to all the stakeholders of the PV industry. There is a need to formulate guidelines to find the correlation of accelerated testing with field degradation for individual degradation modes observed in the field. Potential approaches to fulfill this need were experimented in this project and are presented in this report. Two of the most commonly seen degradation modes – encapsulant browning and solder bond thermomechanical fatigue – are addressed in this report through presenting the accelerated testing methods and physical modelling approaches. Two accelerated test methods (UV and thermal cycling) were designed to induce the wear-out mechanisms in the modules and not infant mortality failures. To focus on the wear-out failure modes, the tests were performed on field-aged modules, instead of fresh modules, with known degradation rates and degradation modes. The degradation rates were measured based on the degradation rates of individual cell parameters (short-circuit current, I sc and series resistance, R s ) instead of the degradation rate of maximum power (P max ) which cannot be used to study any specific/limited degradation mode as the P max degradation could be caused by many different degradation modes. The key characteristic parameter considered for encapsulant discoloration and solder bond degradation is I sc and R s , respectively. The developed physical models/equations relating the testing degradation data and field weather data were utilized to determine the acceleration factor (AF) and to predict the degradation rate for a specific degradation mode of PV modules installed in two different climates, Arizona (hot) and New York (cold). The predicted degradation rates for encapsulant browning and solder bond degradation have also been validated against the actual measured field degradation rates. UV testing cost reduction: To determine acceleration factor, single UV chamber was used for accelerated UV testing at three different temperatures simultaneously, instead of three chambers for three temperatures (or one chamber sequentially which is an extremely time-consuming approach). A passive heating approach was successfully used to achieve and maintain multiple temperatures in the accelerated UV chamber. Foam insulation boards of varying thicknesses were utilized to obtain three different temperatures for UV testing. However, these foam materials tend to disintegrate in the presence of moisture. To alleviate this problem, silicone heating blankets with temperature controls and humidifier can be used if the UV testing is to be performed under hot-humid conditions instead of conventional hot-dry conditions. Thermal cycling testing cost reduction: Single thermal cycling chamber was used for accelerated thermal cycling testing at three different upper temperatures simultaneously, instead of three chambers for three upper temperatures (or one chamber sequentially which is an extremely time-consuming approach). An active heating approach based on silicone heating blankets was successfully used to achieve and maintain multiple upper temperatures in the accelerated thermal cycling chamber. Such blankets provide stable temperature control and thereby more reliable and repeatable for replicate experiments.

14 SOLAR ENERGY↗

BEST Field Degradation Research

Data for control and 5-year fielded bifacial modules of PERC and SHJ technologies, including IV Curves, EQE, EL and PL, for degradation and performance studies.

14 SOLAR ENERGY↗

An atomistic description of the high-field degradation of dielectric polyethylene

A microscopic mechanism governing the initiating step in the high-field aging of crystalline polyethylene is proposed, based on density functional calculations and ab initio molecular dynamics simulations. It is assumed that electrons, holes, and excitons are present in the system. While the additional individual electrons or holes are not expected to lead to significant degradation, the presence of triplet excitons are concluded to be rather damaging. The electron and hole states of the exciton localize on a distorted region of polyethylene, significantly weakening nearby C–H bonds and facilitating C–H bond scission. The barrier to cleavage of the weakened C–H bonds is estimated and is comparable to the thermal energy, suggesting that this mechanism may be responsible for the degradation of polyethylene when placed under electrical stress, e.g., in high-voltage cables.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generalized Spatio-Temporal Model of Backsheet Degradation From Field Surveys of Photovoltaic Modules

Photovoltaic (PV) module backsheets degrade at different rates because of the specific polymeric materials and the local exposure environments of the installations. Studies of real-world backsheet degradation provide valuable information to understand backsheet degradation and failure. Field surveys of PV module backsheets were conducted on 1310 modules in four commercial PV power plant sites with different exposure times. The backsheet's local exposure environment is determined by its location along the rack length and depth, the modules' elevation above the ground, and the ground cover albedo. Backsheets that are installed at the ends of the module rack length exhibit larger degradation rates (with yellowness index difference of 1.14 $\pm$ 0.45 and 7.80 $\pm$ 1.3 for backsheets of poly (ethylene terephthalate) and poly (ethylene naphthalate) as the air-side layer, respectively) than backsheets in the center section of the rack. A generalized spatio-temporal model was developed to predict the large-scale backsheet degradation of different backsheet polymers across time/age and location in the PV power plant rack. The model utilizes a cubic-spline relationship between backsheet degradation and rack length, and a quadratic relationship between backsheet discoloration and rack depth. This generalized spatio-temporal model predicts the outdoor backsheet degradation with an adjusted- $R^2$ range between 0.31 to 0.89. The similarity between this model and the spatial variation of the rear-side irradiance, indicates that the irradiance plays a significant role in outdoor backsheet degradation. The generalized spatio-temporal model can be used to evaluate large scale PV backsheet performance, as well as a guidance for PV site designers and operations and maintenance crews.

14 SOLAR ENERGY↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

Overview of Field Experience - Degradation Rates & Lifetimes

The way a PV module fails may depend not only on its design and the materials used in its construction, but also on the weather it experiences, the way it is mounted, and the quality control during its manufacture. This presentation gives an overview of Field Experience - what degradation rates and what lifetimes are being observed in various regions.

14 SOLAR ENERGY↗

Activity and adaptation of nitrilotriacetate (NTA)-degrading bacteria: field and laboratory studies

Adaptation of bacterial activity for the degradation of nitrilotriacetate (NTA) was studied using natural sediment samples and an NTA-degrading bacterium (strain ATCC 29600). Sediment samples from a river with persistent levels of NTA had much higher NTA-degradative activity than comparable samples from a less contaminated control site. When sediment from the control site was exposed to high levels of NTA a 5 day lag preceded an abrupt increase in NTA degradation while strain 29600 colonized on sand and grown in the absence of NTA became induced within eight hours. The induction of strain 29600 was compared between bacteria in suspension and cells attached to sand. The sand-associated bacteria became induced 4 to 5 h before the planktonic suspension and displayed over threefold greater specific activity. Suspensions of strain 29600 became adapted within 8 h when placed in membrane diffusion chambers that were immersed within a municipal wastewater reactor containing NTA. These findings support the concept that induction is a part of the process of bacterial adaptation to degrade NTA and sand-associated bacteria can adapt more quickly to and have a greater degradative activity for NTA than planktonic cells.

NASA Discipline Number 04-10↗

Measuring Degradation of Fielded Systems on an Ongoing Basis with RdTools

The solar investment community needs up-to-date and data-derived system degradation rates to use in financial models that calculate the risk and expectation of energy revenue. To date, the majority of financial models choose degradation rates from past studies that are limited and may not be representative of future solar assets (systems) they are financing. As the solar industry expands in all sectors (residential, commercial, and utility), there is a growing amount of energy production available to analyze. With the help of the open source degradation analysis code (RdTools) it is now possible to derive degradation on an ongoing basis and continuously provide up-to-date durability statistics to the investment community. Ongoing and accurate statistics of fielded photovoltaic systems allows financial stakeholders to constrain energy revenue projections, lower financial risk, and increase the bankability of solar. This poster will present considerations and software engineering best practices to encourage data owners to measure degradation of their own photovoltaic assets on an ongoing basis. This poster will also preview an upcoming DOE-funded kWh Analytics degradation project which involves applying RdTools analysis on kWh Analytics’ industry database, aggregating results across variables such as weather, hardware, system configurations etc., and sharing the aggregated results with the broader community.

14 SOLAR ENERGY↗

Comprehensive study of performance degradation of field‐mounted photovoltaic modules in India

Abstract The All India Survey of Photovoltaic Module Reliability 2014 is an enhanced version of the survey conducted in the previous year, with detailed characterization of PV modules including current‐voltage, infrared and electroluminescence imaging, visual inspection, insulation resistance test and interconnect breakage test. More than a thousand modules were inspected in the field and the main results of the survey are presented in this paper. The average P max degradation rate for the so‐called ‘good’ modules (Group X) is 1.33%/year which is higher than that commonly projected by manufacturers, and widely employed in financial calculations. Modules falling in the ‘not‐so‐good’ category (Group Y) show even higher degradation rates, and it is at least partly due to higher number of micro‐cracks in the modules, and increased degradation of the packaging materials like encapsulant, backsheet, etc. Modules in ‘Hot’ climates degrade faster than modules in the ‘Non‐Hot’ climates. Degradation in fill factor is the primary cause for performance degradation in the young modules (ages <5 years), whereas short‐circuit current degradation is the main contributor to power degradation in the older modules. Small installations (<100 kW p capacity) show higher degradation than large systems, which may be partly due to lack of proper due diligence by the owner at the time of procurement and installation.

Dubey, Rajiv↗

Use of Pyranometers to Estimate PV Module Degradation Rates in the Field

Methodology is described that uses relative measurements to estimate the degradation rates of PV modules in the field. The importance of calibration and cleaning is discussed. The number of years of field measurements needed to measure degradation rates with data from the field is cut in half using relative comparisons.

14 SOLAR ENERGY↗

Evaluating and predicting molecular mechanisms of adhesive degradation during field and accelerated aging of photovoltaic modules

Extending photovoltaic (PV) module lifetimes beyond 30 years is a goal of significant priority. A challenge that must first be addressed, however, is the development of a predictive reliability model that captures the synergy of terrestrial stressors on module degradation, particularly at encapsulant interfaces. Using a metrology designed specifically for PV modules, a comprehensive study of the widely used ethylene vinyl acetate encapsulant was performed in which encapsulant adhesion was evaluated as a function of environmental stressors (UV exposure, temperature, and humidity) for modules aged both under accelerated lab and internationally located field conditions for months to nearly 3 decades. Mechanical and chemical characterization methods are combined with fundamental polymer reaction engineering to unravel the degradation processes active at the molecular scale that lead to encapsulant delamination. An analytical and modular model framework is put forward enabling the prediction of long-term PV module durability, starting from fundamental principles at the molecular level and explicitly accounting for bond rupture events in the bulk encapsulant and at the encapsulant interfaces. Successful parameter tuning to adhesion data indicates a dominant occurrence of deacetylation, β-scission, and hydrolytic depolymerization, respectively. The model contributes to the longstanding challenge of predicting module lifetimes in any geographic location while minimizing time-consuming and costly aging studies.

14 SOLAR ENERGY↗

Prediction of Climate-Specific Degradation Rate for Photovoltaic Encapsulant Discoloration

Encapsulant discoloration is a well-known field degradation mode of crystalline-silicon photovoltaic modules, particularly in the hot climate zones. The discoloration rate is influenced by several weathering factors, such as UV light, module temperature, and humidity, as well as the permeability of oxygen into the module. Here, a rate dependence model employing the modified Arrhenius equations to predict the degradation rate for encapsulant discoloration in different climates is presented. Two modeling approaches are introduced, which utilize the field and accelerated UV testing degradation data in conjunction with the field meteorological data to determine the acceleration factor for encapsulant browning. A novel method of accelerated UV stress testing at three simultaneous module temperatures in a single environmental chamber test run is implemented to estimate the activation energy for browning. The test was performed on three field-retrieved modules to capture the wear-out failure mechanism. The degradation in short-circuit current Isc rather than maximum power is used as a decisive parameter for the discoloration analysis. Furthermore, the developed model has been used to predict the Isc degradation rate for the Arizona field characterized by a hot and dry climate and is validated against the field-measured value. It has also been applied to other climate types, e.g., the cold and dry climate of New York.

14 SOLAR ENERGY↗

Examination of hot-carrier stress induced degradation on fin field-effect transistor

Degradation in fin field-effect transistor devices was investigated in detail under various hot-carrier stress conditions. The threshold voltage (V{sub TH}) shift, substrate current (I{sub B}), and subthreshold swing were extracted to determine the degradation of a device. The power-law time exponent of the V{sub TH} shift was largest at V{sub G} = 0.3 V{sub D}, indicating that the V{sub TH} shift was dominated by interface state generation. Although the strongest impact ionization occurred at V{sub G} = V{sub D}, the V{sub TH} shift was mainly caused by electron trapping resulting from a large gate leakage current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Zonal shear layer collapse and the power scaling of the density limit: old L-H wine in new bottles

Edge shear layer collapse causes edge cooling and aggravates radiative effects. This paper details on the microscopic dynamics of the emergence of power (Q) scaling of density limit (DL) from the shear layer collapse transport bifurcation scenario. The analysis is based on a novel 4-field model, which evolves turbulence energy, zonal flow energy, temperature gradient and density, including the neoclassical screening of zonal flow response. Bifurcation analysis yields power scaling of critical density for shear layer collapse as $n_{crit}\sim Q^{1/3}$. The favorable Q scaling of the DL emerges from the fact that the shear layer strength increases with Q, thus preventing shear layer collapse. This in turn reduces particle transport and improves particle confinement. RMP induced ambient stochastic fields degrade the shear layer by inducing decoherence in the Reynolds stress. As a result the particle transport increases and particle confinement degrades. This leads to the emergence of unfavorable stochastic field intensity ($b_{st}^{2}$) scaling of the critical density as $n_{crit}\sim(1+b_{st}^{2})^{-5/3}$. All fields, including zonal flow shear, exhibit hysteresis when the power (Q) is ramped cyclically across the bifurcation point. The hysteresis is due to dynamical delay in bifurcation on account of critical slowing down. Furthermore, the dynamical hysteresis here is fundamentally different from the hysteresis associated with the existence of bi-stable states.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.