Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks

Moving target defense (MTD) is a defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation using distributed flexible AC transmission system (D-FACTS) devices. However, existing studies neglect to address a fundamental yet critical issue, i.e., the D-FACTS placement, by assuming that all lines are equipped with D-FACTS devices. Here, to tackle this problem, we first derive analytical necessary conditions and requirements on the D-FACTS placement for a complete MTD. Further, we propose sufficient conditions using a graph theory-based topology analysis to ensure that the MTD under the proposed D-FACTS placement has the maximum rank of its composite matrix, which is indicative of the MTD effectiveness. Based on the analytical conditions, we design D-FACTS placement algorithms by using the minimum number of D-FACTS devices to achieve the maximum MTD effectiveness. A novel MTD-based ACOPF model, in which the reactance of D-FACTS lines is introduced as decision variables, is proposed to find a trade-off between the system loss and the MTD effectiveness. Numerical results on 6-bus, IEEE 14-bus, and IEEE 118-bus systems show the efficacy of MTDs using the proposed D-FACTS placement algorithms in maximizing the composite matrix rank and detecting FDI attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Interior-Point Solver for Optimal Power Flow Problem Considering Distributed FACTS Devices

In this paper, we propose an AC optimal power flow (ACOPF) model considering distributed flexible AC transmission system (D-FACTS) devices, in which the reactance of D-FACTS equipped lines are introduced as decision variables. This is motivated by increasing interests in using D-FACTS devices to address system operational and cyber-security concerns. First, D-FACTS devices can be incorporated in real-time operations for economic benefits such as managing power congestions and reducing system losses. Second, D-FACTS devices can be utilized by moving target defense (MTD), an emerging concept against cyber-attacks, to prevent attackers from knowing true system configurations. Therefore, system operators can use the proposed ACOPF model to achieve economic benefits and provide the setpoints of D-FACTS devices for MTD at the same time. In addition, we rigorously derive the gradient and Hessian matrices of the objective function and constraints, which are further used to build an interior-point solver of the proposed ACOPF. Numerical results on the IEEE 118-bus transmission system show the validity of the proposed ACOPF model as well as the efficacy of the interior-point solver in minimizing system losses and generation costs.

Liu, Bo↗

Spinning the Facts against Genetically Engineered Foods?

A signaling game is developed in order to derive the equilibrium conditions under which special interest groups (SIGs) involved in the controversial debate over genetically engineered (GE) foods have the incentive to truthfully reveal their information or spin facts regarding the health impact of GE foods. Consumers can choose to inspect information provided by SIGs at a cost. The risk of spinning facts is much higher for pro-GE groups, because if it turns out that a certain GE food is unsafe, the penalty will be severe. However, anti-GE groups can still spin facts at low risk even if consumers choose to inspect. This helps explain why some pro-GE groups, particularly the biotech industry, tend to remain silent. Revealing information regarding the safety of GE foods could be counterproductive given pre-existing public skepticism. Consumers may not make “better” decisions with more information provided because more information increases their inspection costs. When it is costlier for consumers to inspect, it is more likely that anti-GE groups will continue to spin facts about the negative health impact of GE foods.

59 BASIC BIOLOGICAL SCIENCES↗

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Series FACTS Devices for Increasing Resiliency in Severe Weather Conditions

Severe weather conditions are low-probability, high-impact events that affect grid operations. The majority of power outages are caused by severe weather conditions. Grid resiliency to weather events can be enhanced by decreasing the reliance on its affected sections. One way to do this is to reduce the power flow through lines vulnerable to severe weather. If a line is disconnected, its initial power flow is distributed through the neighbor lines, which may cause congestion in the grid. FACTS devices can be used to control the power flow of lines that have a higher chance of power outages. Most previous works do not consider weather events in power flow control. In this work, a linearized optimal power flow (OPF)–based algorithm is developed to minimize the real power flow of vulnerable lines considering the thermal limits of lines to prevent infeasible solutions; the simulation is fast, making it suitable for large-scale systems. The proposed optimization problem is presented as a mixed-integer linear program (MILP), making it capable of using short-term load forecasting due to its high solution speed. The proposed optimization problem considers multiple lines with different outage probabilities and the uncertainties of the weather forecast. Moreover, it estimates the power reduction in vulnerable lines due to changes in the series FACTS devices. The performance of the proposed optimization problem is tested on IEEE 14-, 30-, and 118-bus systems for several scenarios. The results are validated with the AC power flow results from MATPOWER.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fact Inventory

API to store fact iA lightweight API service built with Litestar for collecting and storing system information from remote hosts. Designed to handle large-scale concurrency, the service receives HTTP submissions of system facts and package inventory from Ansible, curl, or other client tooling.nformation

Riehecky, Pat [Fermi National Accelerator Laborato↗

Hector-FACTS Technical Report & User Guide: Integrating Hector into the Framework for Assessing Changes To Sea-level

The Framework for Assessing Changes To Sea-level (FACTS) platform was developed by (Kopp et al., 2023) as an open-source modular tool capable of generating probabilistic projections for global mean sea-level change and future relative and extreme sea-level change at New York City (Kopp et al., 2023). FACTS is the first open-source modular tool designed to explore deep uncertainty in SLR while also synthesizing across different modeling groups and integrating the various components of SLR used in key climate reports.

54 ENVIRONMENTAL SCIENCES↗

Duke Forest FACE (FACTS-I): Meteorological and Soil Data

This dataset, collected from Duke Forest Free Air CO2 Enrichment (FACE) – Forest-Atmosphere Carbon Transfer and Storage (FACTS-I) experiment, includes variables describing the meteorological conditions above canopy, within canopy, and soil depending on the variable. The Duke FACE experiment was located in a loblolly pine (Pinus taeda L.) plantation established in 1983. Naturally regenerated broadleaved species including sweetgum (Liquidambar styraciflua L.) and tulip poplar (Liriodendron tulipifera L.), mostly in the overstory, and winged elm (Ulmus alata Michx.) and red maple (Acer rubrum L.) were common in the understory. The FACE experiment commenced with two plots (plots 7-8) in 1994 (Oren et al. 2001), with six additional plots (plots 1-6) coming online on 27 August 1996. The CO2 enrichment was terminated on 31 October 2010 and post-enrichment data collection continued through 2012. Complete fertilization was applied annually to half of plots 7-8 from 1998 to 2004. The nutrient addition experiment expanded to half of plot 1-6 with a common protocol of N-fertilization in 2005. N-fertilization continued until 2012. The data range varied by sensor availability. A summary of information about variable name and data range can be found in the ‘FileDescription_[variable_name].txt’ files.

54 ENVIRONMENTAL SCIENCES↗

Duke Forest FACE (FACTS-I): Plant and Soil Response Data

This dataset describing the responses of plant and soil pools and fluxes to elevated atmospheric CO2 concentration and increased nitrogen supply was collected from Duke Forest Free Air CO2 Enrichment (FACE) – Forest-Atmosphere Carbon Transfer and Storage (FACTS-I) experiment from 1996 to 2012. The dataset includes data files for allometry (diameter at breast height, tree height, and height to live crown base), leaf area index, biomass (stem, branch, foliage, and root biomass, tree density, and basal area), net primary productivity (stem, branch, foliage, reproductive, and coarse root NPP), sap flux density, soil CO2 efflux, and stem temperature. Data files were formatted as .csv (Microsoft Excel or other spreadsheet programs can be used to read the format) and file descriptions, including variable name, unit, and data range, can be found in ‘FileDescription_[data_name].txt’ files. The Duke FACE experiment was in a loblolly pine (Pinus taeda L.) plantation established in 1983. Naturally regenerated broadleaved species including sweetgum (Liquidambar styraciflua L.) and tulip poplar (Liriodendron tulipifera L.), mostly in the overstory, and winged elm (Ulmus alata Michx.) and red maple (Acer rubrum L.) were common in the understory. The FACE experiment commenced with two plots (plots 7-8) in 1994 (Oren et al. 2001), with six additional plots (plots 1-6) coming online on 27 August 1996. CO2 enrichment was terminated on 31 October 2010 and post-enrichment data collection continued through 2012. Complete fertilization was applied annually to half of plots 7-8 from 1998 to 2004. The nutrient addition experiment expanded to half of plots 1-6 with a common protocol of N-fertilization in 2005 and continued until 2012. The levels of treatment in this dataset were expressed as ambient CO2 (AMB) or elevated CO2 (ELE) for CO2 treatment and control soil (CONT) or fertilized soil (FERT) for N treatment, respectively.

54 ENVIRONMENTAL SCIENCES↗

Combined Heat and Power Technology Fact Sheet Series: District Energy

This fact sheet provides an overview of district energy systems, which are characterized by one or more central plants producing hot water, steam, and/or chilled water, which then flows through a network of insulated pipes to provide hot water, space heating, and/or air conditioning for nearby buildings. District energy systems serve a variety of end-use markets, including downtowns (central business districts), college and university campuses, hospitals and healthcare facilities, airports, military bases, and industrial complexes. By combining loads for multiple buildings, district energy systems create economies of scale that help reduce energy costs and enable the use of high-efficiency technologies such as combined heat and power (CHP).

Combined Heat and Power, CHP, District Energy, Tec↗

Combined Heat and Power Technology Fact Sheet Series: Thermal Energy Storage

This fact sheet provides an overview of thermal energy storage (TES) technologies, which heat or cool a storage medium and, when needed, deliver the stored thermal energy to meet heating or cooling needs. TES systems are used in commercial buildings, industrial processes, and district energy installations to deliver stored thermal energy during peak demand periods, thereby reducing peak energy use. TES systems are often integrated with electric or absorption chillers to reduce peak electricity costs and, in the case of new construction, to reduce capital costs by optimizing chiller size. TES technologies can support sites that have either renewable or fossil power generation, including combined heat and power (CHP) installations. With CHP, TES can help optimize equipment size by reducing the required peak CHP thermal capacity and increasing annual CHP usage. TES can also provide turbine inlet cooling for gas turbines used in CHP applications, which increases power production in hot ambient conditions.

Combined Heat and Power, CHP, Thermal Energy, Tech↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The atomic bombings: facts, myths and more

Seventy-five years later, the Trinity test of July 16, 1945 is still rightly remembered as a monumental scientific achievement. The test has a multifaceted legacy representing incredible discovery, unparalleled hope and unprecedented peril. The weapons designed and tested at wartime Los Alamos were not intended to deter, but to destroy: On August 6, 1945, the world’s first weaponized nuclear device was used for that very purpose. Little Boy, a gun-assembled enriched uranium weapon, detonated over Hiroshima that morning destroying several square miles of the city and killing tens of thousands. Three days later, Fat Man, an imploding plutonium weapon, destroyed Nagasaki. On August 14, an armistice was declared and a few weeks later World War II came to an official end. We’ve all heard these historical facts before, but was it really that simple? Nuclear strike + nuclear strike = unconditional surrender? Bringing World War II to an end was an arduous, complex, and very tenuous undertaking with important historical nuances to consider.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Defense & Disaster Deployable Turbine Fact Sheet

The U.S. Department of Energy’s (DOE’s) Defense and Disaster Deployable Turbine (D3T) project is evaluating the market potential for rapidly deployable wind energy technologies. The D3T fact sheet outlines the work with military and wind industry stakeholders to develop deployable wind energy technologies that can meet the unique energy needs of defense operations and responses to humanitarian crises.

wind, defense, disaster, deployable, turbine, ener↗

ATR NEXSHARE Fact Sheet

This fact sheet will provide information for the database of experimental facilities supported by the IAEA as outlined below: NEXSHARE: As part of the Nuclear Harmonization and Standardization Initiative (NHSI), the IAEA proposes to establish a Network for global cooperation and resource sharing for experiments and code validation between experimental facilities, SMRs design organizations, International Organizations and Technical Support Organizations (TSOs). The proposed Network, NEXSHARE, will be done in collaboration with the OECD/NEA. EXPERIMENTAL FACILITY DATABASE: As part of this activity, the IAEA is compiling a database of experimental facilities applicable to SMRs (including water cooled, high temperature gas cooled, molten salt and fast neutron spectrum reactors). This database will also form part of NEXSHARE and will be documented in an IAEA publication.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗