Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Eye Movements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Geometry and Gesture-Based Features from Saccadic Eye-Movement as a Biometric in Radiology

In this study, we present a novel application of sketch gesture recognition on eye-movement for biometric identification and estimating task expertise.The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus for this study.Sketch gesture recognition techniques were employed to extract geometric and gesture-based features from saccadic eye-movements.Our results show that saccadic eye-movement, characterized using sketch-based features, result in more accurate models for predicting individual identity and level of expertise than more traditional eye-tracking features.

Alamudun, Folami↗

Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.

60 APPLIED LIFE SCIENCES↗

Unsupervised Parsing of Gaze Data with a Beta-process Vector Auto-regressive Hidden Markov Model

The first stage of analyzing eye-tracking data is commonly to code the data into sequences of fixations and saccades. This process is usually automated using simple, predetermined rules for classifying ranges of the time series into events, such as “if the dispersion of gaze samples is lower than the threshold, then code as a fixation; otherwise code as a saccade.” More recent approaches incorporate additional eye-movement categories in automated parsing algorithms, particularly glissades, by using time-varying, data-driven thresholds. We describe an alternative approach using the beta-process auto-regressive hidden Markov model (BP-AR-HMM). The BP-AR-HMM offers two main advantages over existing frameworks. First, it provides a statistical model for eye movement classification rather than a single estimate. Second, the BP-AR-HMM uses a latent process to model the number and nature of the types of eye-movements and hence is not constrained to predetermined categories. We applied the BP-AR-HMM both to high-sampling rate gaze data from Andersson, Larsson, Holmqvist, Stridh, and Nyström (2016) and to low-sampling rate data from the DIEM project (Mital, Smith, Hill, & Henderson, 2011). Driven by the data properties, the BP-AR-HMM identified clusters of samples resembling saccades, fixations and smooth pursuit, and a category that approximately corresponds to glissades (as well as blinks, errors, etc.). The BP-AR-HMM serves as an effective algorithm for data-driven event parsing alone or as an initial step in exploring the characteristics of gaze data sets.

eye tracking, fixation, fixation, saccade, smooth ↗

Do morphemes matter when reading compound words with transposed letters? Evidence from eye-tracking and event-related potentials

We investigate the online processing consequences of encountering compound words with transposed letters (TLs), in order to determine if cross-morpheme TLs are more disruptive to reading than those within a single morpheme, as would be predicted by accounts of obligatory morpho-orthopgrahic decomposition. Two measures of online processing, eye movements and event-related potentials (ERPs), were collected in separate experiments. Participants read sentences containing correctly spelled compound words (cupcake), or compounds with TLs occurring either across morphemes (cucpake) or within one morpheme (cupacke). Results showed that between- and within-morpheme transpositions produced equal processing costs in both measures, in the form of longer reading times (Experiment 1) and a late posterior positivity (Experiment 2) that did not differ between conditions. Our findings converge to suggest that within- and between-morpheme TLs are equally disruptive to recognition, providing evidence against obligatory morpho-orthographic processing and in favour of whole-word access of English compound words during sentence reading.

97 MATHEMATICS AND COMPUTING↗

Eye tracking studies based on attentional-resource effectiveness - 310

In the majority of cases, the primary means of information input to operators in nuclear power plants (NPPs) control rooms is through the visual channel. In this study, eye movement patterns of NPP operators are analyzed with eye tracking data obtained from simulator-based experimental studies. Two eye tracking measures of attentional-resource effectiveness in monitoring and detection tasks in NPPs which had been developed by the authors are introduced and several applications with the two eye tracking measures are discussed for the use of the measures. The underlying principle of the measures is that information sources should be selectively attended according to their importance. One of the two measures is the fixation to importance ratio (FIR), which represents attentional resource (eye fixations) spent on an information source compared to the importance of the information source. The other measure is selective attention effectiveness (SAE), which incorporates the FIRs of all information sources. The FIR represents the effectiveness on an information source, whereas the SAE represents the overall effectiveness on all information sources. Frequency and the duration of eye fixations of an operator on information sources are used as attentional resource. Finally feasible future applications with eye tracking data were discussed in terms of plant systems automation and operator training. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report for 2.2.1 Task 2: Provide execution support for the human factors studies conducted for the LWRS Control Room Modernization project for PVNGS

INL contracted IFE to develop custom software functionality to support INL’s use of eye movement tracking in simulator studies. This includes the support of remote eye trackers, the support of dynamic Areas of Interest based on simulator events, and a general-purpose communication protocol between a simulator and the eye tracking software. The report summarises the task deliverables, which include a requirements identification workshop at INL, a software package, and instructional videos.

99 GENERAL AND MISCELLANEOUS↗

Using Eye-Tracking to Quantify Reverse Engineering Expertise

Software reverse engineering (RE) requires analysts to closely read and make decisions about code. Little is known about what makes an analyst successful, making it difficult to train new analysts or design tools to augment existing ones. The goal of this project was to quantify the eye movement behaviors supporting RE and code comprehension more generally. We applied eye-tracking methods from the language comprehension literature to understand where analysts direct their attention over time when completing tasks (e.g., function identification, bug detection). Across three studies, we manipulated aspects of code hypothesized to impact comprehension (e.g., variable name meaningfulness, code complexity) and presentation methods (e.g., line-by-line, free viewing, gaze-contingent moving window) to understand effects on accuracy and gaze patterns. Results showed clear benefits of meaningful variable names, and effects of expertise on global and line-specific viewing patterns. Findings could inspire empirically-supported tool or analytic adaptations that help to reduce analyst workload.

97 MATHEMATICS AND COMPUTING↗

Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.

60 APPLIED LIFE SCIENCES↗

Eye tracking and gating system for proton therapy of orbital tumors

Purpose: A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. Methods: We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, Austin, TX). To measure the pixel spacing of an image consistently, four different calibration modes such as the point-detection, the edge-detection, the line-measurement, and the manual measurement mode were suggested and used. After these methods were applied to proton therapy, gating was performed, and radiation dose distributions were evaluated. Results: Moving phantom verification measurements resulted in errors of less than 0.1 mm for given ranges of translation. Dosimetric evaluation of the beam-gating system versus nongated treatment delivery with a moving phantom shows that while there was only 0.83 mm growth in lateral penumbra for gated radiotherapy, there was 4.95 mm growth in lateral penumbra in case of nongated exposure. The analysis from clinical results suggests that the average of eye movements depends distinctively on each patient by showing 0.44 mm, 0.45 mm, and 0.86 mm for three patients, respectively. Conclusions: The developed automatic eye-tracking based beam-gating system enabled us to perform high-precision proton radiotherapy of orbital tumors.

60 APPLIED LIFE SCIENCES↗

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

Temporal Stability of Visual Search-Driven Biometrics

Previously, we have shown the potential of using an individual s visual search pattern as a possible biometric. That study focused on viewing images displaying dot-patterns with different spatial relationships to determine which pattern can be more effective in establishing the identity of an individual. In this follow-up study we investigated the temporal stability of this biometric. We performed an experiment with 16 individuals asked to search for a predetermined feature of a random-dot pattern as we tracked their eye movements. Each participant completed four testing sessions consisting of two dot patterns repeated twice. One dot pattern displayed concentric circles shifted to the left or right side of the screen overlaid with visual noise, and participants were asked which side the circles were centered on. The second dot-pattern displayed a number of circles (between 0 and 4) scattered on the screen overlaid with visual noise, and participants were asked how many circles they could identify. Each session contained 5 untracked tutorial questions and 50 tracked test questions (200 total tracked questions per participant). To create each participant s "fingerprint", we constructed a Hidden Markov Model (HMM) from the gaze data representing the underlying visual search and cognitive process. The accuracy of the derived HMM models was evaluated using cross-validation for various time-dependent train-test conditions. Subject identification accuracy ranged from 17.6% to 41.8% for all conditions, which is significantly higher than random guessing (1/16 = 6.25%). The results suggest that visual search pattern is a promising, fairly stable personalized fingerprint of perceptual organization.

eye tracking↗

Sleep: A Novel Mechanistic Pathway, Biomarker, and Treatment Target in the Pathology of Alzheimer's Disease?

Sleep disruption appears to be a major component of Alzheimer's disease (AD) and its pathophysiology. Signature abnormalities of sleep emerge before clinical onset of AD. Moreover, insufficient sleep facilitates accumulation of amyloid-β (Aβ), potentially triggering earlier cognitive decline and conversion to AD. Building on such findings, this review has four goals: evaluating (i) associations and plausible mechanisms linking non-rapid-eye-movement (NREM) sleep disruption, Aβ, and AD; (ii) a role for NREM sleep disruption as a novel factor linking cortical Aβ to impaired hippocampus-dependent memory consolidation; (iii) the potential diagnostic utility of NREM sleep disruption as a new biomarker of AD; and (iv) the possibility of sleep as a new treatment target in aging, affording preventative and therapeutic benefits.

59 BASIC BIOLOGICAL SCIENCES↗