Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Extremities/physiology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Adaptation in a rotating artificial gravity environment

The centripetal force generated by a rotating space vehicle is a potential source of artificial gravity. Minimizing the cost of such a vehicle dictates using the smallest radius and highest rotation rate possible, but head movements made at high rotation rates generate disorienting, nauseogenic cross-coupled semicircular canal stimulation. Early studies suggested 3 or 4 rpm as the highest rate at which humans could adapt to this vestibular stimulus. These studies neglected the concomitant Coriolis force actions on the head/neck system. We assessed non-vestibular Coriolis effects by measuring arm and leg movements made in the center of a rotating room turning at 10 rpm and found that movement endpoints and trajectories are initially deviated; however, subjects readily adapt with 10-20 additional movements, even without seeing their errors. Equilibrium point theories of motor control errantly predict that Coriolis forces will not cause movement endpoint errors so that subjects will not have to adapt their reaching movements during rotation. Adaptation of movement trajectory acquired during Coriolis force perturbations of one arm transfers to the unexposed arm but there is no intermanual transfer of endpoint adaptation indicating that neuromotor representations of movement endpoint and trajectory are separable and can adapt independently, also contradictory to equilibrium point theories. Touching a surface at the end of reaching movements is required for complete endpoint adaptation in darkness but trajectory adapts completely with or without terminal contact. We have also made the first kinematic measurements of unconstrained head movements during rotation, these movements show rapid adaptation to Coriolis force perturbations. Our results point to methods for achieving full compensation for rotation up to 10 rpm. Copyright 1998 Published by Elsevier Science B.V.

Non-NASA Center

Altered astronaut lower limb and mass center kinematics in downward jumping following space flight

Astronauts exposed to the microgravity conditions encountered during space flight exhibit postural and gait instabilities upon return to earth that could impair critical postflight performance. The aim of the present study was to determine the effects of microgravity exposure on astronauts' performance of two-footed jump landings. Nine astronauts from several Space Shuttle missions were tested both preflight and postflight with a series of voluntary, two-footed downward hops from a 30-cm-high step. A video-based, three-dimensional motion-analysis system permitted calculation of body segment positions and joint angular displacements. Phase-plane plots of knee, hip, and ankle angular velocities compared with the corresponding joint angles were used to describe the lower limb kinematics during jump landings. The position of the whole-body center of mass (COM) was also estimated in the sagittal plane using an eight-segment body model. Four of nine subjects exhibited expanded phase-plane portraits postflight, with significant increases in peak joint flexion angles and flexion rates following space flight. In contrast, two subjects showed significant contractions of their phase-plane portraits postflight and three subjects showed insignificant overall changes after space flight. Analysis of the vertical COM motion generally supported the joint angle results. Subjects with expanded joint angle phase-plane portraits postflight exhibited larger downward deviations of the COM and longer times from impact to peak deflection, as well as lower upward recovery velocities. Subjects with postflight joint angle phase-plane contraction demonstrated opposite effects in the COM motion. The joint kinematics results indicated the existence of two contrasting response modes due to microgravity exposure. Most subjects exhibited "compliant" impact absorption postflight, consistent with decreased limb stiffness and damping, and a reduction in the bandwidth of the postural control system. Fewer subjects showed "stiff" behavior after space flight, where contractions in the phase-plane portraits pointed to an increase in control bandwidth. The changes appeared to result from adaptive modifications in the control of lower limb impedance. A simple 2nd-order model of the vertical COM motion indicated that changes in the effective vertical stiffness of the legs can predict key features of the postflight performance. Compliant responses may reflect inflight adaptation due to altered demands on the postural control system in microgravity, while stiff behavior may result from overcompensation postflight for the presumed reduction in limb stiffness inflight.

Clinical Trial