Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Event-triggered”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Agent-Supervisor Coordination for Decentralized Event-Triggered Optimization

This letter proposes decentralized resource-aware coordination schemes for solving network optimization problems defined by objective functions that combine locally evaluable costs with network-wide coupling components. These methods are well suited for a group of supervised agents trying to solve an optimization problem under mild coordination requirements. Each agent has information on its local cost and coordinates with the network supervisor for information about the coupling term of the cost. The proposed approach is feedback-based and asynchronous by design, guarantees anytime feasibility, and ensures the asymptotic convergence of the network state to the desired optimizer. Numerical simulations on a power system example illustrate our results.

decentralized algorithms↗

Cybersecurity Enhancement for Multi-Infeed High-Voltage DC Systems

Composed of multiple two-terminal high-voltage DC (HVDC) transmission systems, a multi-infeed HVDC (MIDC) system exchanges massive power among multiple asynchronous AC systems. However, as an intrinsically cyber-physical system, an MIDC system could suffer from cyber-attacks, leading to massive power mismatches in multiple AC systems, and resulting in catastrophic consequences. Since the sequential responses of an MIDC system and interconnected AC systems are in different timescales, this paper first establishes a two-timescale model to evaluate the sequential impacts caused by cyber-attacks. Then, an event-triggered cyber-defense strategy is proposed to enhance the cybersecurity of an MIDC system by mitigating multiple non-simultaneous cyber-attacks. Whenever new cyber-attack events occur, the proposed cyber-defense strategy, which is mathematically modeled as a mixed-integer quadratic programming problem, is executed on-line and updated in an event-triggered manner. Here, simulation results on an MIDC system demonstrate that the low-cost and almost blind cyber-attacks can cause severe frequency deviations, and the proposed strategy can mitigate multi-cyber-attacks effectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Cost and Benefit of Enhancing Cybersecurity for Hybrid AC/DC Grids

As critical interfaces of AC grids and DC grids inside a hybrid AC/DC grid, the voltage-sourced-converter (VSC) has been demonstrated to be vulnerable to false data injection (FDI) cyber-attacks. As a result, the cyber-attack-induced AC grid frequency deviations and DC grid voltage deviations threaten the secure operation. Here, to enhance cybersecurity in a not only feasible but also cost-effective manner, this paper proposes a cost-benefit-based cyber-defense strategy for a hybrid AC/DC grid. First, this paper establishes a spatial-temporal dual cyber-attack evaluation model, in which the cyber-attack-induced frequency and voltage deviations are modelled in both a spatially and temporally dual manner. Then, the proposed cost-benefit-based cyber-defense strategy is modelled as a VSC commitment problem to achieve the trade-off between maximizing the cyber-defense benefits and minimizing the cyber-defense costs. The VSC commitment problem is then mathematically convexified into a mixed-integer second-order cone programming (MISOCP) problem, which could be efficiently solved in an event-triggered manner against unfolding cyber-attack events. Simulation results on a test hybrid AC/DC grid verified the feasibility and the cost-effectiveness of the proposed cyber-defense strategy.

cost-benefit analysis↗

A reinforcement learning approach to long-horizon operations, health, and maintenance supervisory control of advanced energy systems

In this work, we develop a Reinforcement Learning (RL) approach to the supervisory control problem for advanced energy systems, such as novel nuclear reactors and other demand-driven, mission-critical, and component-health-sensitive energy plants. The inclusive problem landscape considered captures the stochastic confluence of plant performance, component health evolution, power demand from the grid, diverse maintenance actions, and operator-defined goals and constraints, all considered over meaningfully long-enough reasoning horizons. Key aspects of the proposed approach are a receding horizon control-inspired technique dictating time- or event-triggered supervisory policy (re-)constructions, as well as additional capability-enabling contributions such as timescale compression, to handle long reasoning horizons and uncertainty in parts of the problem, and practical yet demonstrably-effective handling of hybrid action spaces with continuous and discrete decision variables. The resulting algorithm consists of a simulation-based RL agent constructing stochastic supervisory control policies over nontrivial action spaces and for long horizons, applying the learned policy to the system for a much shorter interval, and perpetually repeating, to construct the next long-horizon policy. That next policy will only be applied, again, for a short interval, yet originally far-in-time events move progressively closer, their associated uncertainty decreases, and new events and aspects enter the reasoning horizon. The proposed methodology bridges fundamental receding horizon concepts with the unequivocally stronger and more scalable reasoning of contemporary RL. Numerical examples using Soft Actor–Critic Deep RL illustrate the operation and efficacy of the proposed technique for a power plant tasked with health-aware load following missions in a dynamic electricity market landscape.

97 MATHEMATICS AND COMPUTING↗

Integrated control of individual plasma scalars with simultaneous neoclassical tearing-mode suppression

A novel integrated-control architecture has been tested in nonlinear, one-dimensional simulations using the control-oriented transport simulator (COTSIM©) and in DIII-D experiments. Integrated architectures that can perform continuous-mission control while also handling off-normal events will be vital in future reactor-grade tokamaks. Continuous-mission controllers for individual magnetic and kinetic scalars (thermal stored-energy (W), volume-average toroidal rotation (Ω Φ ), and safety factor profile (q) at different spatial locations) have been integrated in this work with event-triggered neoclassical tearing-mode (NTM) suppression controllers by combining them into an architecture augmented by a supervisory and exception handling (S&EH) system and an actuator management (AM) system. Here, the AM system, which enables the integration of competing controllers, solves in real time a nonlinear optimization problem that takes into account the high-level control priorities dictated by the S&EH system. The resulting architecture offers a high level of integration and some of the functionalities that will be required to fulfill the advanced-control requirements anticipated for ITER. Initial simulations using COTSIM suggest that the plasma performance and its MHD stability may be improved under integrated feedback control. In addition, the integrated-control architecture has been implemented in the DIII-D plasma control system and tested experimentally for the first time ever in DIII-D in a high-q min scenario, which is a candidate for steady-state operation in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a 3-..phi.., 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

communication systems↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed Inference with Sparse and Quantized Communication

Here, we consider the problem of distributed inference where agents in a network observe a stream of private signals generated by an unknown state, and aim to uniquely identify this state from a finite set of hypotheses. We focus on scenarios where communication between agents is costly, and takes place over channels with finite bandwidth. To reduce the frequency of communication, we develop a novel event-triggered distributed learning rule that is based on the principle of diffusing low beliefs on each false hypothesis. Building on this principle, we design a trigger condition under which an agent broadcasts only those components of its belief vector that have adequate innovation, to only those neighbors that require such information. We prove that our rule guarantees convergence to the true state exponentially fast almost surely despite sparse communication, and that it has the potential to significantly reduce information flow from uninformative agents to informative agents. Next, to deal with finite-precision communication channels, we propose a distributed learning rule that leverages the idea of adaptive quantization. We show that by sequentially refining the range of the quantizers, every agent can learn the truth exponentially fast almost surely, while using just 1 bit to encode its belief on each hypothesis. For both our proposed algorithms, we rigorously characterize the trade-offs between communication-efficiency and the learning rate.

42 ENGINEERING↗

Training Spiking Neural Networks with Synaptic Plasticity under Integer Representation

Neuromorphic computing is emerging as a promising Beyond Moore computing paradigm that employs event-triggered computation and non-von Neumann hardware. Spike Timing Dependent Plasticity (STDP) is a well-known bio-inspired learning rule that relies on activities of locally connected neurons to adjust the weights of their respective synapses. In this work, we analyze a basic STDP rule and its sensitivity on the different hyperparameters for training spiking neural networks (SNNs) with supervision, customized for a neuromorphic hardware implementation with integer weights. We compare the classification performance on four UCI datasets (iris, wine, breast cancer and digits) that depict varying levels of complexity. We perform a search for optimal set of hyperparameters using both grid search and Bayesian optimization. Through the use of Bayesian optimization, we show the general trends in hyperparameter sensitivity in SNN classification problem. With the best sets of hyperparameters, we achieve accuracies comparable to some of the best performing SNNs on these four datasets. With a highly optimized supervised STDP rule we show that these accuracies can be achieved with just 20 epochs of training.

Kulkarni, Shruti↗

Enabling Command-and-Control in Advanced In Situ Workflows

Scientific discovery is progressing towards autonomous science with the combination of scientific instruments, high-performance computing, and artificial intelligence in complex workflows. This evolution introduces new requirements for managing scientific workflows, including feedback loops, near real-time constraints, and the ability to dynamically control workflow execution. In situ workflows that analyze and visualize data as it is generated are well-suited to satisfy stringent time constraints and their iterative nature offers greater opportunities for command-and-control. However, only a few of the many workflow management systems available have been specifically designed to manage in situ workflows and often lack support for automated feedback loops that allow analysis and visualization components to interact with the main scientific data producer. To address this need, we present in this paper how to add command-and-control capabilities to a workflow management system. We identify the functional design requirements of such a command-and-control system, detail its architecture, interface, and core mechanisms, and illustrate how advanced in situ workflows can leverage command-and-control in three use cases: graceful termination with checkpoint, dynamic and adaptive data reduction, and event-triggered analysis.

Mehta, Kshitij [ORNL] (ORCID:0000000297149981)↗

MPC4CLR (Model-Predictive-Control-for-Critical-Load-Restoration-in-Power-Distribution-Systems) [SWR-22-24]

Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.

Eseye, Abinet Tesfaye↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a three-phase electric power, 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

grid-forming inverter↗

Development of a Practical Secondary Control for Hardware Microgrids: Preprint

Practical vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that works with all GFM IBRs and synchronous generators. This secondary control does not need to employ any additional measurement devices in the MG and uses the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus holding registers such as packet loss, quantization error, etc. and their deteriorating impacts on the secondary control action are investigated. The proposed three-stage modification of any secondary control architecture to eliminate these impacts includes 1) averaging the data read, 2) situational event-triggering of the controller, and 3) the finite iteration of the controlling action. The proposed method is validated using a laboratory hardware MG with commercial GFM units.

inverter based resources↗

Ripple-Type Control for Enhancing Resilience of Networked Physical Systems

Distributed control agents have been advocated as an effective means for improving the resiliency of our physical infrastructures under unexpected events. Purely local control has been shown to be insufficient, centralized optimal resource allocation approaches can be slow. In this context, we put forth a hybrid low-communication saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a “hotline” communication network. According to this protocol, agents act on local readings unless their control resources have been depleted, in which case they send a beacon for assistance to peer agents. Our ripple-type scheme triggers communication locally only for the agents with saturated resources and it is proved to converge. Moreover, under a monotonicity assumption on the underlying physical law coupling control outputs to inputs, the devised control is proved to converge to a configuration satisfying safe operational constraints. The assumption is shown to hold for voltage control in electric power systems and pressure control in water distribution networks. Numerical tests corroborate the efficacy of the novel scheme.

distributed control↗