Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Evaluation Studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Case Study: Seattle Waterfront Networked Microgrid Evaluation - Case Study for Port Electrification Handbook

Many ports and waterfronts are evaluating alternative electrification efforts, including electrification of passenger and vehicle ferries. In Seattle, the Washington State Department of Transportation, in conjunction with Seattle City Light (the local utility) and the Port of Seattle, are working to deploy a hybrid electric ferry and provide charging at Seattle’s Colman dock. As part of this ferry electrification effort, Seattle City Light is considering including a large battery energy storage system (BESS) to help “buffer” the ferry charging. The “buffer” provides energy arbitrage and spreads out the large amount of power needed to recharge the ferry to times when the ferry is out of the dock – rather than one very large peak for 15 minutes, the battery storage allows it to be a smaller power value over a longer duration. This initial BESS concept served as the jumping off point to explore an expanded microgrid concept via a notional test system that incorporates additional distributed energy resources (DER) and infrastructure upgrades to the local distribution infrastructure at the Seattle Waterfront and neighboring Port of Seattle properties. This case study examined the potential for secondary use of the BESS within a networked microgrid during the scenario of a large-scale power outage, such as a natural disaster.

24 POWER TRANSMISSION AND DISTRIBUTION

Microstructure Validation of Graph Theory Model-Derived Cooling Rates in the Wire Arc Additive Manufacturing of ER70S-6 Steel

Wire arc additive manufacturing (WAAM) enables high-rate fabrication of large metallic components, but spatial variations in thermal history can lead to microstructural heterogeneity that requires efficient process models to evaluate. This study evaluates whether cooling rates extracted from a graph theory model (GTM)-based thermal simulation are consistent with the microstructural evolution observed in an ER70S-6 WAAM wall. Thermal histories from the model were analyzed at selected build heights, and cooling rates were extracted from the final thermal excursion through the austenite phase field. Microstructures at corresponding locations were characterized using electron backscatter diffraction (EBSD) to quantify grain size distributions, and pearlite interlamellar spacing was used as an additional indicator of cooling behavior. The modeled cooling rates were highest near the substrate and generally decreased with build height, consistent with the observed reduction in the fine grain fraction and the progressive shift in the grain size distribution as build height increased. Pearlite spacing trends also supported the modeled cooling rate variation. These results indicate that GTM-derived thermal histories can be post-processed into metallurgically meaningful cooling rate estimates for WAAM steel builds and linked to dataset specific empirical grain size distribution relationships for process–thermal history–microstructure assessment.

36 MATERIALS SCIENCE

Supercritical water desalination and oxidation (SCWDO): Effectiveness on complex solutions, technoeconomic, and CO 2 impact for produced water treatment

The modern energy-economy is increasingly causing the production of highly saline brines, including from produced water. Supercritical water desalination can concentrate and extract minerals from these brines, but the effects of mixed salt interactions, organic degradation with additives, and the technology's economics are not well understood at supercritical condition. The present study evaluated and experimentally studied an integrated supercritical water desalination and oxidation (SCWDO) process for treating real-produced water samples from oil/natural gas field. The complex interactions between the various anions and cations in produced water were extensively evaluated. Most of the divalent and trivalent ions were extracted below 250 °C while the majority of the monovalent salt were removed between 380 to 410 °C. The treated real produced water was of drinking water quality, with <500 mg/l of total dissolved solid (TDS) and with 100% organics removal. Furthermore, the heat liberated during the organic oxidation could be utilized internally and for electricity generation for enhanced the energy efficiency and lower cost of produced water treatment. With system optimization, the proposed SCWDO process can essentially be made a net zero energy process. A novel process flow diagram for the commercial scale self-powered hybrid SCWDO technology was proposed as a cost-effective produced water treatment to mitigate the environmental crises. Techno-economic analysis showed that produced water treatment cost with SCWDO can be reduced to 2–3 $/m 3 and can be up to 60 % cheaper to traditional deep well reinjection. Additionally, the proposed SCWDO process could achieve net negative CO 2 emission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY

A Million Person Study Innovation: Evaluating Cognitive Impairment and other Morbidity Outcomes from Chronic Radiation Exposure Through Linkages with the Centers for Medicaid and Medicare Services Assessment and Claims Data

Here, the study of One Million U.S. Radiation Workers and Veterans, the Million Person Study (MPS), examines the health consequences, both cancer and non-cancer, of exposure to ionizing radiation received gradually over time. Recently the MPS has focused on mortality patterns from neurological and behavioral conditions, e.g., Parkinson's disease, Alzheimer's disease, dementia, and motor neuron disease such as amyotrophic lateral sclerosis. A fuller picture of radiation-related late effects comes from studying both mortality and the occurrence (incidence) of conditions not leading to death. Accordingly, the MPS is identifying neurocognitive diagnoses from fee-for-service insurance claims from the Centers for Medicare and Medicaid Services (CMS), among Medicare beneficiaries beginning in 1999 (the earliest date claims data are available). Linkages to date have identified ∼540,000 workers with available health information. Such linkages provide individual information on important co-factor and confounding variables such as smoking, alcohol consumption, blood pressure, obesity, diabetes and many other health and demographic characteristics. The total person-level set of time-dependent variables, outcomes, organ-specific dose measures, co-factors, and demographics will be massive and much too large to be evaluated with standard software. Thus, development of specialized open-source software designed for large datasets (Colossus) is nearly complete. The wealth of information available from CMS claims data, coupled with individual dose reconstructions, will thus greatly enhance the quality and precision of health evaluations for this new field of low-dose radiation and neurocognitive effects.

Dauer, Lawrence T.

Data for Multisite Field Evaluation of Oil Accumulation and Agronomic Performance in Grain and Sweet Sorghums Engineered for Lipid Hyperaccumulation

Oil sorghum (OS) has been developed by engineering grain (TX430) and sweet (Ramada) genetic backgrounds to accumulate triacylglycerols (TAG) in vegetative tissues as an energy-dense feedstock for sustainable aviation fuel (SAF) and other biofuels. This study evaluated two TX430 OS lines (TxHO-2, TxHO-3) and two Ramada OS lines (RmHO-1, RmHO-2) alongside wild-type (WT) lines in NE and IL over 2 years (2023–2024) to quantify genotype × environment effects on agronomic performance and TAG accumulation. Across four environments, TX430 OS lines showed average TAG concentrations of 15.0 g kg−1 in leaves and 12.8 g kg−1 in stems, approximately 19-fold higher than WT. Ramada OS lines accumulated 26.1 g kg−1 in leaves and 12.3 g kg−1 in stems, approximately 25-fold and 13-fold increases over WT, respectively. OS lines in TX430 exhibited an 18% reduction in biomass (8.4 vs. 9.9 Mg ha−1 for WT), while Ramada OS lines had similar WT biomass (18.3 vs. 19.9 Mg ha−1 for WT). Among TX430 OS lines, TxHO-2 achieved the highest TAG yield (190 kg ha−1), while RmHO-1 led the Ramada lines (335 kg ha−1) due to higher biomass and similar TAG concentration. Enhanced TAG accumulation increased N, P, and K removal in TX430 lines but not in Ramada lines. Structural carbohydrate and ash concentration were unaffected. Overall, results confirm vegetative lipid accumulation as a viable strategy for high-biomass sorghum, supporting its potential as a dual-purpose feedstock for SAF. Future work should focus on minimizing biomass yield penalties and improving nutrient use efficiency in oil sorghum systems.

Agronomy

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Batch Extraction Studies to Evaluate Trace Element Behavior in PUREX Conditions

The multilab Intentional Forensics Venture is working to identify which stable elements (i.e., taggants) at trace concentrations relative to U would persist throughout the nuclear fuel cycle in a voluntary fuel tagging scheme. A taggant would provide the nuclear forensics community with a “barcode” to help identify nuclear materials found outside of regulatory control. A portion of this project was focused on reprocessing effects and determining which, if any, elements would coextract with U(VI) in standard Pu–U reduction extraction (PUREX) conditions. Elements with a propensity to coextract could, in theory, be used as taggants from a PUREX perspective. Although retention is not a performance requirement, the taggant signature would need to partition predictably from the U stream after the PUREX process to maintain forensic utility. This report documents results from several batch extraction studies with numerous trace elements from HNO 3 (1.5–5 M), with and without U(VI), into 30% tri-n-butyl phosphate (TBP) in kerosene. Extraction and back-extraction tests were used to evaluate nearly 60 elements in surrogate conditions for PUREX, and distribution coefficients (i.e., D-values) for most species were <0.1, indicating few species are likely to co-extract with U through PUREX. Additional studies are needed to optimize sample volumes and dilutions to dial in these low D-values. The D-values (D) were determined for several of the more promising elements, including Re and Se. Ultimately, we conclude that only a limited number of the ~ 60 elements investigated are extractable in the U stream of PUREX, based on measured D values, meaning most candidate elemental taggants would likely be lost at this stage of the nuclear fuel cycle, even when considering a range of acid concentrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

Data for Nitrogen Dynamics and Physiological N Use Efficiency in High-biomass Sorghum

Improving nitrogen (N) efficiency is essential for sustainable high-biomass sorghum ( Sorghum bicolor L. Moench ) production. This study evaluated leaf and stem N dynamics, canopy N remobilization, and physiological nitrogen use efficiency (pNUE) in two photoperiod-sensitive sorghum hybrids under two N rates (0 and 168 kg-N ha−1) across multiple environments in Texas and Illinois. Leaf N concentrations increased with plant height in the canopy with steeper gradients under low-N conditions, indicating enhanced N remobilization when N is limited. Stem tissue showed less variation in N concentration across canopy nodal positions, with within-plant differences ranging from 1.2 to 7.6 g kg−1, compared to 3.1 to 16.3 g kg−1 in leaves. While pNUE was generally higher under unfertilized conditions, it varied largely by site; however, genotypic differences were minimal within the given year. These results highlight the importance of integrating environmental and management factors into breeding and fertilization strategies to enhance N efficiency in high-biomass sorghum.

Nitrogen

Impact of Heaters on Molten Salt Reactors Dynamics

Recently, there has been renewed interest in the Molten Salt Reactor (MSR) concept. This interest is mainly due to its advantages over Light Water Reactors (LWRs). Among these advantages are the flexibility in the fuel choice and the possibility to burn actinides [1]. Currently, two molten research reactors are under development. A 2 MW molten salt experimental reactor has been constructed and is planned for operation in China. A 1 MW Molten Salt Research Reactor is under construction in the United States [2]. Thus, Research and Development (R&D) programs are needed for the MSR technology. Reactor dynamics studies are crucial safety evaluation studies. The development of reactor dynamics tools for MSRs started during the Molten Salt Reactor Program (MSRP) at ORNL, focusing on the Molten Salt Reactor Experiment (MSRE) [3]. Although various dynamic simulation tools are available, R&D efforts to develop specialized tools for MSRs are still ongoing [4]. The primary motivation for this interest is the goal of commercializing MSRs. Developing a dynamics tool for MSRs is crucial for analyzing their safety and supporting their demonstration efforts. A crucial safety issue in MSRs is ensuring that the fuel salt in the primary loop remains molten. This concern becomes particularly important when the reactor operates at lower power levels. Most chloride and fluoride salts used as fuel have a melting point of approximately 450 °C [5]. Therefore, maintaining fuel salt temperatures above this melting point is essential to prevent it from freezing. Freezing of the fuel salt can lead to volume expansion, potentially causing damage to reactor components [6]. Moreover, it can create local blockages within fuel salt channels, reducing cooling efficiency and resulting in hot spots [7]. Various methods can prevent fuel salt from freezing at low power levels. These include reducing the fuel mass flow rate in the primary loop, decreasing heat exchange between the primary and secondary loops in the reactor, and using electric fuel salt heaters. Reducing the mass flow rate of fuel salt in the primary loop can increase the fuel salt transit time in the core, enhancing heat production and increasing temperature. However, it can potentially lead to challenges. These include increasing the potential for fuel salt deposition on the reactor channel walls [8], affecting the overall heat transfer processes. Thus, alternative methods should be used [9]. This research investigates the effects of fuel salt heaters on the dynamics and stability during MSR operation. The investigation includes studying the reactor stability with the fuel salt heaters on and off. In addition, the reactor response to transients is compared with and without the operation of fuel salt heaters. These transients include reactivity insertion, primary and secondary pump failure, and heat sink temperature increase. The results of the reactivity insertion transient are presented in the summary.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS

Dynamic soil columns simulate Arctic redox biogeochemistry and carbon release during changes in water saturation

Thawing Arctic permafrost can induce hydrologic change and alter redox conditions, shifting the balance of soil organic matter (SOM) decomposition. There remains uncertainty about how soil saturation and redox transitions impact dissolved and gas phase carbon fluxes, and efforts to link hydrobiogeochemical processes to ecosystem-scale models are limited. This study evaluates SOM decomposition of Arctic tundra soils using column experiments, water chemistry measurements, microbial community analysis, and a PFLOTRAN reactive transport model. Soil columns from a thermokarst channel (TC) and an upland tundra (UC) were exposed to cycles of saturation and drainage, which controlled carbon emissions. During saturation, an outflow of dissolved organic carbon from the UC soil correlated with elevated reduced iron and decreased pH; during drainage, UC carbon dioxide fluxes were 70% higher than TC fluxes. Intermittent methane release was observed for TC, consistent with higher methanogen abundance. Slower drainage in the TC soil correlated with more subtle biogeochemical changes. PFLOTRAN simulations captured experimental trends in soil carbon fluxes, oxygen concentrations, and water contents. The model was then used to evaluate additional soil water drainage rates. This study emphasizes the importance of considering hydrologic change when evaluating and simulating SOM decomposition in dynamic Arctic tundra environments.

54 ENVIRONMENTAL SCIENCES

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program. A 2016 study looked more broadly at overall code impacts and this report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced emissions at the state level and at aggregated levels. In 2021, DOE conducted an interim and limited update to its 2016 study to evaluate potential building code updates using the 2016 methodology. That interim update includes estimated savings resulting from updates to the model energy codes, including the ANSI/ASHRAE/IES Standard 90.1-2016 (ASHRAE 90.1-2016) and 2019 editions, as well as the 2018 and 2021 International Energy Conservation Code (IECC). In 2023, DOE developed a fully updated report that includes code updates (ASHRAE 90.1-2019 and 2021 IECC), as well as additional enhancements and updates, including updated energy prices, annual floorspace additions, state code adoption dates, and emission factors, among others. This current version is another fully updated report that includes code updates (ASHRAE 90.1-2022 and 2024 IECC), as well as additional enhancements and updates, including updated energy prices, state code adoption dates, emission factors, and renewable energy contribution among others. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when the new code is implemented and builders, architects, and engineers are required to comply with the new provisions. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. The contributions of all three phases are crucial to the overall impact of codes and are considered in this assessment. Figure ES.1 schematically describes the analysis framework. Energy savings are expressed in terms of energy use intensity (EUI) in the figure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Training Evaluation: A Case Study of Measuring Impact and ROI

The purpose of this case study was to evaluate the Compliance Officer/Coordinator (CO/CC) training program using Phillips’ approach to training evaluation. INL Learning Performance Consultants (LPCs) applied the ROI Methodology to measure the effectiveness of the CO/CC training program. INL CO/CCs participated in focus groups to provide feedback on their learning, enablers and barriers to applying what they learned, and opportunities to improve the CO/CC learning experience. With collaboration from the CO/CC training program owner, the LPCs demonstrated the business impact and return on investment (ROI) of the CO/CC training program. Included are training program recommendations and lessons learned using the ROI Methodology.

99 GENERAL AND MISCELLANEOUS

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

GPM IMERG V07B and V06B: Evaluation Using Ground-Based Radar Observations and Application in Global Mesoscale Convective System Tracking

This study evaluates the latest Global Precipitation Measurement (GPM) Integrated Multi-satellitE Retrievals for GPM (IMERG V07B) against its predecessor V06B, for studying mesoscale convective systems (MCSs). Both versions are compared using ground-based radar and rain gauge data from five meteorologically diverse regions: the contiguous United States (including eastern coastlines), Amazon rainforest, central Argentina mountains, equatorial Indian Ocean, and northern Australia across multiple temporal (0.5–6 hours) and spatial scales (0.1°–0.25°). An updated global MCS tracking dataset is developed by integrating satellite-observed infrared brightness temperature with IMERG V07B. Comparation of IMERG against radar observations reveals that IMERG demonstrates better performance in capturing the probability distribution and quantitative contributions of rainfall (from no-rain to intense-rain conditions) over tropical oceans than over land, with marked improvements in IMERG V07B for heavy-to-intense rain (> 10 mm h-1). Over land, systematic biases persist: IMERG tends to overestimate light-to-moderate rain (1–10 mm h-1) while underestimating heavy-to-intense rain. Additionally, aggregating IMERG to coarser resolutions (3-hourly or 0.25°) improves consistency with radar observations, outperforming the 1-hourly/0.1° resolution. The new IMERG V07B-based global MCS dataset exhibits consistent statistical characteristics with the V06B-based dataset, despite lower mean rain rates and reduced heavy precipitation contributions. These findings offer valuable insights for utilizing IMERG V07B in global precipitation studies, MCS characterization, and model evaluation.

Zhang, Sihan

Evaluation of 1/100-Scale Mooring Systems for Wave Energy Converters

This study evaluates the feasibility, accuracy, and limitations of using 1/100th scale physical mooring systems to represent full-scale mooring behavior for wave energy converters (WECs) during small-scale tank testing. The work focuses on an RM3-style point absorber deployed in conditions representative of the PacWave South test site and examines whether small-scale physical testing can reliably inform numerical modeling, design decisions, and future prototype development. Overall, this study concludes that small-scale (1/100th) physical mooring models can provide valuable qualitative insights, including relative comparisons between mooring types and trends in device behavior, but cannot reliably replicate full-scale mooring loads or dynamic response without significant scaling distortion. Physical tests at this scale are most appropriate for motion characterization and model validation within known limitations, not for deriving absolute mooring loads or final engineering design values. Key lessons learned emphasize the importance of improved instrumentation strategies, iterative wave tank tuning, more precisely manufactured scaled mooring components, and enhanced anchoring systems to reduce experimental uncertainty.

16 TIDAL AND WAVE POWER