Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ergonomic Evaluations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ergonomic Evaluations of Microgravity Workstations

Various gloveboxes (GBXs) have been used aboard the Shuttle and ISS. Though the overall technical specifications are similar, each GBX's crew interface is unique. JSC conducted a series of ergonomic evaluations of the various glovebox designs to identify human factors requirements for new designs to provide operator commonality across different designs. We conducted 2 0g evaluations aboard the Shuttle to evaluate the material sciences GBX and the General Purpose Workstation (GPWS), and a KC-135 evaluation to compare combinations of arm hole interfaces and foot restraints (flexible arm holes were better than rigid ports for repetitive fine manipulation tasks). Posture analysis revealed that the smallest and tallest subjects assumed similar postures at all four configurations, suggesting that problematic postures are not necessarily a function of the operator s height but a function of the task characteristics. There was concern that the subjects were using the restrictive nature of the GBX s cuffs as an upper-body restraint to achieve such high forces, which might lead to neck/shoulder discomfort. EMG data revealed more consistent muscle performance at the GBX; the variability in the EMG profiles observed at the GPWS was attributed to the subjects attempts to provide more stabilization for themselves in the loose, flexible gauntlets. Tests revealed that the GBX should be designed for a 95 percentile American male to accommodate a neutral working posture. In addition, the foot restraint with knee support appeared beneficial for GBX operations. Crew comments were to provide 2 foot restraint mechanical modes, loose and lock-down, to accommodate a wide range of tasks without egressing the restraint system. Thus far, we have developed preliminary design guidelines for GBXs and foot.

Whitmore, Mihriban↗

Ergonomic Evaluation of the Foot Restraint Equipment Device (FRED)

Within the scope of the Microgravity Workstation and Restraint Evaluation project, funded by the NASA Headquarters Life Sciences Division, evaluations were proposed to be conducted in ground, KC-135, and/or Shuttle environments to investigate the human factors engineering (HFE) issues concerning confined/unique workstations, including crew restraint requirements. As part of these evaluations, KC-135 flights were conducted to investigate user/ workstation/ restraint integration for microgravity use of the FRED with the RMS workstation. This evaluation was a pre-cursor to Detailed Supplementary Objective (DSO) - 904 on STS-88. On that mission, a small-statured astronaut will be using the FRED restraint while working at the Aft RMS workstation. The DSO will collect video for later posture analyses, as well as subjective data in the form of an electronic questionnaire. This report describes the current FRED KC-135 evaluations. The primary objectives were to evaluate the usability of the FRED and to verify the DSO in-flight setup. The restraint interface evaluation consisted of four basic areas of restraint use: 1) adjustability; 2) general usability and comfort; 3) usability at the RMS workstation; and 4) assembly and disassembly.

Whitmore, Mihriban↗

Ergonomic Evaluation of Space Shuttle Light-Weight Seat Lever Position and Operation

During a Shuttle flight in the early part of 1999, one of the crewmembers was unable to operate the backrest lever for the light-weight seat in microgravity. It is essential that the crewmembers are able to adjust this back-rest lever, which is titled forward 2 degrees from vertical during launch and then moved backwards to 10 degrees aft of vertical upon reaching orbit. This adjustment is needed to cushion the crewmembers during an inadvertent crash landing situation. The original Shuttle seats, which had seat controls located on the front left and right sides of the seat, were replaced recently with the new light-weight seats. The controls for these new, seats were moved to the night side with one control at the front and the other at the back. While it was uncertain whether the problem encountered was unique to that crewmember or not it was clear to the personnel responsible for maintaining the Shuttle seats that not knowing the cause of the problem posed a safety concern for NASA. Hence the Anthropometry and Biomechanics Facility (ABF) of the Johnson Space Center was requested to perform an evaluation of the seat controls and provide NASA with appropriate recommendations on whether the seat lever positions and operations should be modified. The ABF designed an experiment to investigate the amount of pull force exerted by subjects, wearing an unpressurized or pressurized crew launch escape suit, when controls were placed in the front and back (on the right side) of the light-weight seat. Single-axis load cells were attached to the seat levers, which measured the maximum static pull forces that were exerted by the subjects. Twelve subjects, six male and six female, participated in this study. Each subject was asked to perform the pull test at least three times for each combination of lever position and suit pressure conditions. The results from this study showed that as a whole (or in general), the subjects were able to pull on the lever at the back position with only about half the amount of force that they were able to exert on the lever at the front position. In addition, the results also showed that subjects wearing the pressurized suit were unable to reach the seat lever when it was located at the back. Furthermore, the pull forces on the front lever diminished about 50 % when subjects wore the pressurized suits. Based on these results from this study, it was recommended to NASA that the levers should not be located in the back position. In addition, further investigation is needed on whether the levers at the front of the seat could be modified or adjusted to increase the leverage for crew members wearing pressurized launch/escape suits.

Maida, J.↗

Spacesuit and Space Vehicle Comparative Ergonomic Evaluation

With the advent of the latest manned spaceflight objectives, a series of prototype launch and reentry spacesuit architectures were evaluated for eventual down selection by NASA based on the performance of a set of designated tasks. A consolidated approach was taken to testing, concurrently collecting suit mobility data, seat-suit-vehicle interface clearances and movement strategies within the volume of a Multi-Purpose Crew Vehicle mockup. To achieve the objectives of the test, a requirement was set forth to maintain high mockup fidelity while using advanced motion capture technologies. These seemingly mutually exclusive goals were accommodated with the construction of an optically transparent and fully adjustable frame mockup. The mockup was constructed such that it could be dimensionally validated rapidly with the motion capture system. This paper will describe the method used to create a motion capture compatible space vehicle mockup, the consolidated approach for evaluating spacesuits in action, as well as the various methods for generating hardware requirements for an entire population from the resulting complex data set using a limited number of test subjects. Kinematics, hardware clearance, suited anthropometry, and subjective feedback data were recorded on fifteen unsuited and five suited subjects. Unsuited subjects were selected chiefly by anthropometry, in an attempt to find subjects who fell within predefined criteria for medium male, large male and small female subjects. The suited subjects were selected as a subset of the unsuited subjects and tested in both unpressurized and pressurized conditions. Since the prototype spacesuits were fabricated in a single size to accommodate an approximately average sized male, the findings from the suit testing were systematically extrapolated to the extremes of the population to anticipate likely problem areas. This extrapolation was achieved by first performing population analysis through a comparison of suited subjects performance to their unsuited performance and then applying the results to the entire range of population. The use of a transparent space vehicle mockup enabled the collection of large amounts of data during human-in-the-loop testing. Mobility data revealed that most of the tested spacesuits had sufficient ranges of motion for tasks to be performed successfully. A failed tasked by a suited subject most often stemmed from a combination of poor field of view while seated and poor dexterity of the gloves when pressurized or from suit/vehicle interface issues. Seat ingress/egress testing showed that problems with anthropometric accommodation does not exclusively occur with the largest or smallest subjects, but rather specific combinations of measurements that lead to narrower seat ingress/egress clearance.

England, Scott↗

Comparative Ergonomic Evaluation of Spacesuit and Space Vehicle Design

With the advent of the latest human spaceflight objectives, a series of prototype architectures for a new launch and reentry spacesuit that would be suited to the new mission goals. Four prototype suits were evaluated to compare their performance and enable the selection of the preferred suit components and designs. A consolidated approach to testing was taken: concurrently collecting suit mobility data, seat-suit-vehicle interface clearances, and qualitative assessments of suit performance within the volume of a Multi-Purpose Crew Vehicle mockup. It was necessary to maintain high fidelity in a mockup and use advanced motion-capture technologies in order to achieve the objectives of the study. These seemingly mutually exclusive goals were accommodated with the construction of an optically transparent and fully adjustable frame mockup. The construction of the mockup was such that it could be dimensionally validated rapidly with the motioncapture system. This paper describes the method used to create a space vehicle mockup compatible with use of an optical motion-capture system, the consolidated approach for evaluating spacesuits in action, and a way to use the complex data set resulting from a limited number of test subjects to generate hardware requirements for an entire population. Kinematics, hardware clearance, anthropometry (suited and unsuited), and subjective feedback data were recorded on 15 unsuited and 5 suited subjects. Unsuited subjects were selected chiefly based on their anthropometry in an attempt to find subjects who fell within predefined criteria for medium male, large male, and small female subjects. The suited subjects were selected as a subset of the unsuited medium male subjects and were tested in both unpressurized and pressurized conditions. The prototype spacesuits were each fabricated in a single size to accommodate an approximately average-sized male, so select findings from the suit testing were systematically extrapolated to the extremes of the population to anticipate likely problem areas. This extrapolation was achieved by first comparing suited subjects performance with their unsuited performance, and then applying the results to the entire range of the population. The use of a transparent space vehicle mockup enabled the collection of large amounts of data during human-in-the-loop testing. Mobility data revealed that most of the tested spacesuits had sufficient ranges of motion for the selected tasks to be performed successfully. A suited subject's inability to perform a task most often stemmed from a combination of poor field of view in a seated position, poor dexterity of the pressurized gloves, or from suit/vehicle interface issues. Seat ingress and egress testing showed that problems with anthropometric accommodation did not exclusively occur with the largest or smallest subjects, but also with specific combinations of measurements that led to narrower seat ingress/egress clearance.

England, Scott↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis.

Reid, Christopher R.↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis

Reid, Christopher R.↗

An Ergonomic Evaluation of the Extravehicular Mobility Unit (EMU) Space Suit Hard Upper Torso (HUT) Size Effect on Metabolic, Mobility, and Strength Performance

The objective of this project was to assess the performance differences between a nominally sized Extravehicular Mobility Unit (EMU) space suit and a nominal +1 (plus) sized EMU. Method: This study evaluated suit size conditions by using metabolic cost, arm mobility, and arm strength as performance metrics. Results: Differences between the suit sizes were found only in shoulder extension strength being 15.8% greater for the plus size. Discussion: While this study was able to identify motions and activities that were considered to be practically or statistically different, it does not signify that use of a plus sized suit should be prohibited. Further testing would be required that either pertained to a particular mission critical task or better simulates a microgravity environment that the EMU suit was designed to work in.

Reid, Christopher↗

The Need to Reevaluate Nonresponding Ergonomic Patients

The Kennedy Space Center (KSC) Environmental Health (EH) contractor performs ergonomic evaluations under its Ergonomic Program. Any KSC employee may request one or the reviewing physician may request one for a patient during a visit to an onsite medical facility. As part of the ergonomic evaluation, recommendations are given to the patient to help reduce any ergonomic problems they experience. The recommendations, if implemented, are successful in the majority of KSC patients; however, a group of patients do not seem to improve. Those who don't improve may be identified by reevaluations, which are performed to implement maximum resolution of ergonomic problems.

Scarpa, Philip J.↗

Manipulator Report for Pacific Northwest 2016

An initial ergonomic evaluation of the manipulators in was performed in 2007 and again in 2008. Discussion and solution development was performed with the new management team, FLM, and the employee on March 23, 2009. The purpose of this evaluation was to identify improvements to reduce stress and risk of injury to the employees. The primary ergonomic related risk factors identified include static and awkward postures especially for the wrist, and repetitive motion of fine motor musculature of the hand and forearm depending on the work load. This memorandum is intended as a starting point to reduce the ergonomic-related risk factors present in this process. All risk factors were probably not identified during this initial evaluation due to limited task demonstrations. The solution development and implementation process is a team effort. The Ergonomics Team provides technical support and guidance; employees demonstrate tasks, provide ideas, and test and provide feedback on potential solutions; and management provides the resources and encourages participation in the process.

42 ENGINEERING↗

Executive Summary: Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room

Under the United States Department of Energy Light Water Sustainability Program (LWRS), Idaho National Laboratory (INL) is collaborating with Palo Verde Generating Station (PVGS) to support human factors engineering efforts in the modernization of PVNGS’ radiological waste system (LRS) control room. The studies proposed and/or conducted by INL are designed to address the inconsistency between different human factors standards, guidance, and conventions. Guidance such as NUREG-0700 leave much of the information open to interpretation. INL will identify whether maintaining a design that is consistent with population stereotypes actually enhances performance, or whether there are alternative designs that yield performance that is better than the designs that maintain those stereotypes. The overall design concept for the LRS workstation includes system overview displays for the Evaporator system and the Boric Acid Concentrator system. A third display contains overview information for the rest of the LRS. The forth display contains alarm information. Each display will be presented on one of four monitors in the control room. The system overview displays contain embedded controls for valves and pumps, mini-trends, and micro-trends. The mini-trends present data for the controllers and contain alarm set point information as well as trending. All other relevant system parameters are shown on micro-trends. The semi-dull screen approach utilized present dynamic data in green, active components are white (gray when closed or off). The product stream flow paths are indicated by different colors. Alarm states are presented in saturated red and selected components are indicated by bright blue. In addition to the micro task study described below, the INL researchers also conducted an evaluation of the semi-dull screen approach as well as an ergonomic evaluation of the suggested upgrades in the local control room. A detailed report of all INL’s activities related to the modernization of the LRS conducted between October 2016 and September 2017 are found in these two reports; • INL-EXT-17-43226, Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room, and • INL-EXT-17-43250, Evaluation of Control Room Interface Designs to Support Modernization in Nuclear Power Plants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Pamphlet Targeting Computer Workstation Ergonomics

With the increased use of computers throughout Goddard Space Flight Center, the Industrial Hygiene Office (IHO) has observed a growing trend in the number of health complaints attributed to poor computer workstation setup. A majority of the complaints has centered around musculoskeletal symptoms, including numbness, pain, and tingling in the upper extremities, shoulders, and neck. Eye strain and headaches have also been reported. In some cases, these symptoms can lead to chronic conditions such as repetitive strain injuries (RSI's). In an effort to prevent or minimize the frequency of these symptoms among the GSFC population, the IHO conducts individual ergonomic workstation evaluations and ergonomics training classes upon request. Because of the extensive number of computer workstations at GSFC, and the limited amount of manpower which the Industrial Hygiene staff could reasonably allocate to conduct workstation evaluations and employee training, a pamphlet was developed with a two-fold purpose: (1) to educate the GSFC population about the importance of ergonomically-correct computer workstation setup and the potential effects of a poorly configured workstation; and (2) to enable employees to perform a general assessment of their own workstations and make any necessary modifications for proper setup.

Faraci, Jennifer S.↗

Robotic experiment with a force reflecting handcontroller onboard MIR space station

During the French CASSIOPEE mission that will fly onboard MIR space station in 1996, ergonomic evaluations of a force reflecting handcontroller will be performed on a simulated robotic task. This handcontroller is a part of the COGNILAB payload that will be used also for experiments in neurophysiology. The purpose of the robotic experiment is the validation of a new control and design concept that would enhance the task performances for telemanipulating space robots. Besides the handcontroller and its control unit, the experimental system includes a simulator of the slave robot dynamics for both free and constrained motions, a flat display screen and a seat with special fixtures for holding the astronaut.

Delpech, M.↗

A review of adaptive change in musculoskeletal impedance during space flight and associated implications for postflight head movement control

We present a review of converging sources of evidence which suggest that the differences between loading histories experienced in 1-g and weightlessness are sufficient to stimulate adaptation in mechanical impedance of the musculoskeletal system. As a consequence of this adaptive change we argue that we should observe changes in the ability to attenuate force transmission through the musculoskeletal system both during and after space flight. By focusing attention on the relation between human sensorimotor activity and support surfaces, the importance of controlling mechanical energy flow through the musculoskeletal system is demonstrated. The implications of such control are discussed in light of visual-vestibular function in the specific context of head and gaze control during postflight locomotion. Evidence from locomotory biomechanics, visual-vestibular function, ergonomic evaluations of human vibration, and specific investigations of locomotion and head and gaze control after space flight, is considered.

Review, Tutorial↗

Toward an IMU-based Space Suit Motion Capture System

Spacesuits are complex engineering systems that sustain human health and enable performance outside of Earth-like environments. These systems must support human mobility and physical workload demands while minimizing injury risk during extravehicular activity (EVA). Future EVA on the lunar surface during the Artemis program is expected to be more frequent and require higher physical workloads than previous EVAs during the ISS, Shuttle, or Apollo programs. Hence it is important to optimize future as well as current spacesuits to be efficient and comfortable for the success of space and planetary missions. To enable this, an efficient method is needed to test these spacesuits on the ground.When testing spacesuits in ground environments, it is often necessary to understand the kinematics of the suit to validate the design against relevant requirements or characterize the physical workload necessary to operate the suit. This is a challenging task for traditional optical motion capture (OMC) approaches: suit-mounted OMC markers are easily occluded by the subject or environment and may become detached during testing. Controlling lighting and reflectivity of objects in the motion capture volume is also difficult. Fixed-position OMC cameras also constrain testing to a small and contrived laboratory environment, disallowing kinematics capture in field environments.One promising alternative is the use of suit-mounted inertial measurement units (IMUs). These sensors are small, unobtrusive, and portable, but come at the cost of increased sensor noise and complexity of the software and mathematics to analyze the collected data. To this end, engineers at NASA are developing the Augmented Suit Inverse Kinematics (ASIK) system, a complete motion capture methodand inverse kinematics solver which relies solely on a network of wireless IMUs attached to the major kinematic segments of the spacesuit. The ASIK modeling language allows for the simple inclusion of probabilistic priors such as suit size and shape or IMU positions and rotations. Furthermore, to increase accuracy and reduce operational overhead to use this motion capture approach, the developed inverse kinematics solver exploits so-called self-calibratingalgorithmic techniques, which reduce the need for precise alignment of the sensors on the segments or scripted functional calibration procedures. The ASIK system was tested in a 7-subject pilot study. Each subject donned NASA’s new prototype exploration spacesuit in the Active Response Gravity Offload System (ARGOS) facility at the NASA Johnson Space Center. The subjects were outfitted with a set of 14 APDM (Portland, OR, USA) Opal IMUs, 12 of which were used in the ASIK model to estimate lower body and trunk kinematics. The subjects were also outfitted with a set of reflective OMC markers and traditional OMC data was collected and processed. Presented results will include characterization of ASIK-derived suit joint angles accuracy against an optical motion capture datum. Discussion of these results, as well as discussion of system calibration and nuances of mathematical observability, will be included.If successful, IMU-based motion capture will enable testing and validation of spacesuits more frequently, with less overhead, in more extreme environments. Future work will apply these techniques to common spacesuit testing tasks, such as gait, mobility, and balance assessment, physical workload characterization, and ergonomics evaluations.

Timothy Mcgrath↗

Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Baseline Human Factors and Ergonomics in Support of Control Room Modernization at Nuclear Power Plants

As part of control room modernization at a nuclear power plant, a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model . These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—meant to catalog final products—rather than formative—meant to guide the overall modernization process. In this report, we highlight two crucial formative subelements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two subelements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomic baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and help ensure that control room modernization represents the successful evolution of the control system.

99 GENERAL AND MISCELLANEOUS↗