Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ErPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Materials Data on ErP by Materials Project

ErP is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. Er3+ is bonded to six equivalent P3- atoms to form a mixture of corner and edge-sharing ErP6 octahedra. The corner-sharing octahedral tilt angles are 0°. All Er–P bond lengths are 2.81 Å. P3- is bonded to six equivalent Er3+ atoms to form a mixture of corner and edge-sharing PEr6 octahedra. The corner-sharing octahedral tilt angles are 0°.

36 MATERIALS SCIENCE↗

Materials Data on ErP by Materials Project

ErP is Tetraauricupride structured and crystallizes in the cubic Pm-3m space group. The structure is three-dimensional. Er3+ is bonded in a body-centered cubic geometry to eight equivalent P3- atoms. All Er–P bond lengths are 2.98 Å. P3- is bonded in a body-centered cubic geometry to eight equivalent Er3+ atoms.

36 MATERIALS SCIENCE↗

Materials Data on ErPS by Materials Project

ErPS crystallizes in the orthorhombic Pnma space group. The structure is three-dimensional. there are two inequivalent Er3+ sites. In the first Er3+ site, Er3+ is bonded in a 9-coordinate geometry to four equivalent P1- and five S2- atoms. All Er–P bond lengths are 3.07 Å. There are a spread of Er–S bond distances ranging from 2.75–2.88 Å. In the second Er3+ site, Er3+ is bonded in a 9-coordinate geometry to four equivalent P1- and five S2- atoms. There are two shorter (2.89 Å) and two longer (3.07 Å) Er–P bond lengths. There are a spread of Er–S bond distances ranging from 2.71–2.82 Å. P1- is bonded in a 6-coordinate geometry to four Er3+ and two equivalent P1- atoms. There are one shorter (2.24 Å) and one longer (2.28 Å) P–P bond lengths. There are two inequivalent S2- sites. In the first S2- site, S2- is bonded in a 5-coordinate geometry to five Er3+ atoms. In the second S2- site, S2- is bonded to five Er3+ atoms to form a mixture of distorted edge and corner-sharing SEr5 trigonal bipyramids.

36 MATERIALS SCIENCE↗

WHONDRS 48 Hour Diel Cycling Study at the Erpe River, Germany

This dataset is from a sampling campaign completed over the course of 48 hours to investigate the effects of wastewater treatment plant effluent induced water level variation on aqueous chemistry, dissolved organic matter chemistry, and metabolic potential of microbial communities at the Erpe River, Germany. Filtered surface water (SW) and pore water (PP) samples were collected every three hours in September 2018. This dataset is one of seven companion datasets that were part of the WHONDRS 48 Hour Diel Cycling Study of freshwater rivers. All seven datasets are available on ESS-DIVE; they can be found by searching for WHONDRS 48 Hour.This package contains a variety of chemical and hydrologic variables. All data types are provided in a standard format. Basic geochemistry analyses (e.g., non-purgeable organic carbon concentration, cations, anions, SpC, pH) were conducted, standardized photos were taken, surface water hydrographs were collated from existing instrumentation, and extensive metadata were captured. Aqueous chemistry variables include USGS codes in the first portion of the variable name (e.g., 00940_Cl_mg_per_L). These codes allow for interoperability with USGS water quality data. In addition, samples were delivered to the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory) for high resolution characterization of dissolved organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The data package contains instructions to process the FTICR data based on the user’s specific needs, and sample-level summary indices derived from the FTICR data will be added to the data package. Beyond the data in this data package, metagenomic data are being generated on associated microbial communities. When these data are available, the data package will be updated with information on accessing them. Please contact WHONDRS@pnnl.gov for more information. Please use the data package’s DOI to cite the data package. We ask that you email us at WHONDRS@pnnl.gov to let us know that you're using the data and acknowledge WHONDRS and the U.S. Department of Energy's Subsurface Biogeochemical Research program—which generously provides funding to WHONDRS—in your publications, proposals, presentations, etc. All data are free to be used for any purpose, such as for manuscripts, presentations, and grant proposals. There is no obligation to include WHONDRS members as co-authors.

54 ENVIRONMENTAL SCIENCES↗

Time will tell: A longitudinal investigation of brain-behavior relationships during reading development

ERPs are a powerful tool for the study of reading, as they are both temporally precise and functionally specific. These are essential characteristics for studying a process that unfolds rapidly and consists of multiple, interactive subprocesses. In work with adults, clear, specific models exist linking components of the ERP with individual subprocesses of reading including orthographic decoding, phonological processing, and semantic access (e.g., Grainger & Holcomb, 2009). The relationships between ERP components and reading subprocesses are less clear in development; here, we address two questions regarding these relationships. First, we ask whether there are ERP markers that predict future reading behaviors across a longitudinal year. Second, we ask whether any relationships observed between ERP components and reading behavior across time map onto the better-established relationships between ERPs and reading subprocesses in adults. To address these questions, we acquired ERPs from children engaging in a silent reading task and then, a year later, collected behavioral assessments of their reading ability. Finally, we find that ERPs collected in Year 1 do predict reading behaviors a year later. Further, we find that these relationships do conform, at least to some extent, to relationships between ERP components and reading subprocesses observed in adults, with, for example, N250 amplitude in Year 1 predicting phonological awareness in Year 2, and N400 amplitude in Year 1 predicting vocabulary in Year 2.

60 APPLIED LIFE SCIENCES↗

Plant-Level Scenario-Based Risk Analysis for Enhanced Resilient PWR – SBO and LBLOCA

This report documents the activities performed during the FY2018 for the DOE Light Water Reactor Sustainability (LWRS) Program, Risk-Informed System Analysis (RISA) Pathway, Enhanced Resilient Plant (ERP) Systems research. The purpose of the RISA Pathway research and development is to support plant owner-operator decisions with the aim to improve the economics, reliability, and maintain the high levels of safety of current nuclear power plants over periods of extended plant operations. The concept of ERP refers to the combinations of Accident Tolerant Fuel (ATF), optimal use of Diverse and Flexible Coping Strategy (FLEX), enhancements to plant components and systems, and the incorporation of augmented or new passive cooling systems, as well as improved fuel cycle efficiency. The objective of the ERP research effort is to use the RISA methods and toolkit in industry applications, including methods development and early demonstration of technologies, in order to enhance existing reactors safety features (both active and passive) and to substantially reduce operating costs through risk-informed approaches to plant design modifications to the plant and their characterization. There are two main focus areas in FY2018 for the ERP R&D efforts. One is to evaluate the risk impact brought by the ATF designs and FLEX in the selected accident scenarios. The other is to investigate various approaches to accomplish the ERP research objective, i.e., use RISA methods and toolkit to enhance existing reactors safety features and reduce plant operating costs.

99 GENERAL AND MISCELLANEOUS↗

Frisker Response to Soil Concentrations (Bq/g) Compared to NaI(Tl) - 19338

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Portions of the site land areas have become radiologically contaminated through the 1952 National Reactor Experimental (NRX) accident and/or waste management activities over the past 70 years of site operations. The Environmental Remediation Projects Group (ERP) characterizes, and performs risk assessment, and remedial actions, as required over these contaminated land areas. ERP work activities are subject to controls established by CRL's Radiation Protection (RP) Group such that RP establishes the radiological controls and monitoring requirements for ERP field work activities. The different methods of monitoring soil contamination between ERP and the RP program present some challenges in the interpretation and comparison of the two sets of results and the soil disposition. ERP utilizes NaI(Tl) scintillation detectors and MARSSIM land scanning techniques to measure soil concentrations between sample locations and in excavated materials. Whereas, RP utilizes surface contamination monitoring equipment in the form of a 15.5 cm{sup 2} open area pancake Geiger-Mueller (GM) tube detector to measure soil contamination levels reported in counts per minute (cpm). This paper presents a method to evaluate the theoretical best responses that could be obtained from surface contamination monitoring instrumentation for a known concentration (1 Bq/g) of various radionuclides. A static efficiency of cpm/Bq{sup -1} g{sup -1} is obtained from these calculations. These contamination monitoring sensitivities are then used in a MARSSIM scanning sensitivity equation and compared to the scanning sensitivity of an NaI(Tl) scintillation detector. The results demonstrate that the sensitivity of the frisker probes to particle radiations (betas for pancake) tend to fall in a range of only a few cpm/Bq{sup -1} g{sup -1}. Rather, the primary static response of the pancake probe to soil contamination is from gamma radiation where a value of 36 cpm/Bq{sup -1} g{sup -1} for Cs-137 was obtained at 2.54 cm distance without the application of scanning statistics. In comparison, a 7.6 cm x 7.6 cm NaI(Tl) detector has a Cs-137 static response factor of 10,000 cpm/Bq{sup -1} g{sup -1} at 15 cm distance without applying scanning statistics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A cognitive electrophysiological signature differentiates amnestic mild cognitive impairment from normal aging

Background: Noninvasive and effective biomarkers for early detection of amnestic mild cognitive impairment (aMCI) before measurable changes in behavioral performance remain scarce. Cognitive event-related potentials (ERPs) measure synchronized synaptic neural activity associated with a cognitive event. Loss of synapses is a hallmark of the neuropathology of early Alzheimer’s disease (AD). In the present study, we tested the hypothesis that ERP responses during working memory retrieval discriminate aMCI from cognitively normal controls (NC) matched in age and education. Methods: Eighteen NC, 17 subjects with aMCI, and 13 subjects with AD performed a delayed match-to-sample task specially designed not only to be easy enough for impaired participants to complete but also to generate comparable performance between subjects with NC and those with aMCI. Scalp electroencephalography, memory accuracy, and reaction times were measured. Results: Whereas memory performance separated the AD group from the others, the performance of NC and subjects with aMCI was similar. In contrast, left frontal cognitive ERP patterns differentiated subjects with aMCI from NC. Enhanced P3 responses at left frontal sites were associated with nonmatching relative to matching stimuli during working memory tasks in patients with aMCI and AD, but not in NC. The accuracy of discriminating aMCI from NC was 85% by using left frontal match/nonmatch effect combined with nonmatch reaction time. Conclusions: The left frontal cognitive ERP indicator holds promise as a sensitive, simple, affordable, and noninvasive biomarker for detection of early cognitive impairment.

60 APPLIED LIFE SCIENCES↗

The impacts of training on change deafness and build-up in a flicker task

Performance on auditory change detection tasks can be improved by training. We examined the stimulus specificity of these training effects in behavior and ERPs. A flicker change detection task was employed in which spatialized auditory scenes were alternated until a "change" or "same" response was made. For half of the trials, scenes were identical. The other half contained changes in the spatial locations of objects from scene to scene. On Day 1, participants were either trained on this auditory change detection task (trained group), or trained on a non-auditory change detection task (control group). On Day 2, all participants were tested on the flicker task while EEG was recorded. The trained group showed greater change detection accuracy than the control group. They were less biased to respond "same" and showed full generalization of learning from trained to novel auditory objects. ERPs for "change" compared to "same" trials showed more negative going P1, N1, and P2 amplitudes, as well as a larger P3b amplitude. The P3b amplitude also differed between the trained and control group, with larger amplitudes for the trained group. Analysis of ERPs to scenes viewed prior to a decision revealed build-up of a difference between "change" and "same" trials in N1 and P2. Results demonstrate that training has an impact early in the "same" versus "change" decision-making process, and that the flicker paradigm combined with the ERP method can be used to study the build-up of change detection in auditory scenes.

60 APPLIED LIFE SCIENCES↗

Using recordings of brain activity to predict and improve human performance

This project investigated methods for using recordings of event-related potentials (ERPs) to predict and improve human memory performance. In a series of experiments, the ERPs related to good and poor memory performance were characterized and a computational model was developed in which the ERPs recorded while a person studied words were used to predict whether that person would be a high performer or a low performer on a subsequent memory test. These experiments provide the first demonstration of ERPs used to predict subsequent memory performance. Additional experiments investigated the effects of different types of memory training (learning a memory strategy such as mental imagery or increasing memory capacity through working memory training) on memory performance and the associated brain activity.

Matzen, Laura E.↗

Risk-Informed Analysis for Enhanced Resilient Nuclear Power Plant with Initiatives including ATF, FLEX, and Advanced Battery Technology

This report documents the activities performed by the Idaho National Laboratory (INL) during fiscal year (FY) 2021 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk-Informed Systems Analysis (RISA) Pathway, Enhanced Resilient Plant (ERP) Systems research. The purpose of the RISA Pathway research and development is to support plant owner-operator decisions with the aim to improve the economics, reliability, and maintain the high levels of safety of current nuclear power plants over periods of extended plant operations. The concept of ERP refers to the combinations of accident-tolerant fuel (ATF), optimal use of diverse and flexible coping strategy (FLEX), enhancements to plant components and systems, the incorporation of augmented or new passive cooling systems, the advanced battery technology with extended capacity, as well as improved fuel cycle efficiency. The objective of the ERP research effort is to use the RISA methods and toolkit in industry applications, including methods development and early demonstration of technologies, in order to enhance existing reactors? safety features and to substantially reduce operating costs through risk-informed approaches to plant design modifications to the plant and their characterization. The ERP R&D efforts in FY 2021 are focused on three industry initiatives, including accident-tolerant fuel (ATF), optimal use of diverse and flexible coping strategy (FLEX), and advanced battery technology with extended capacity.

99 GENERAL AND MISCELLANEOUS↗

Strengthening Retrofit Markets for Comprehensive Savings in Multifamily Buildings (Interim Final Report)

Energy efficiency is vitally important in Maine. Nearly 70% of Maine households rely on fuel oil as their primary energy source for home heating, a higher share than in any other state. Coupled with the state's long, cold winters, Maine's dependence on oil renders homeowners particularly vulnerable to fluctuating fuel costs. With $\$$4.5 million in seed funding from the Energy Department's Better Buildings Neighborhood Program, the Governor's Energy Office (GEO), through Efficiency Maine Trust (the Trust), is spurring Maine landlords to lower their monthly energy bills and improve comfort for their tenants during the state's cold winter months and increasingly warmer summers. Maine's aging multifamily housing stock can be expensive to heat and costly to maintain. It is not unusual to find buildings with little or no insulation, drafty windows, and significant air leaks, making them ideal candidates for energy efficiency upgrades. Maine modeled its Multifamily Efficiency Program (MEP) after the state's highly successful Home Energy Savings Program (HESP) for single-family homes. HESP provided cash incentives and financing opportunities to owners of one-to four-unit structures, which resulted in thousands of energy assessments and whole-house energy upgrades in 225 communities. Maine's new MEP multifamily energy efficiency upgrade and weatherization initiative focuses on small to medium-sized (i.e., five to 20 units) apartment buildings. The program's energy efficiency upgrades will provide at least 20% energy savings for each upgraded multifamily unit. The Trust’s MEP relies on a network of approved program partners who help move projects through the pipeline from assessment to upgrade. MEP has two components: benchmarking and development of an Energy Reduction Plan (ERP). Using the ENERGY STAR® Portfolio Manager benchmarking tool, MEP provides an assessment of current energy usage in the building, establishes a baseline for future energy efficiency improvements, and enables tracking and monitoring of future energy usage at the building— all at no cost to the building owner. The ERP is developed by a program partner using either the Trust’s approved modeling or prescriptive tools; it provides detailed information about the current energy related conditions in the building and recommends energy efficiency, health, and safety improvements. The Trust's delivery contractor provides quality assurance and controls throughout the process. Through this effort, MEP's goal is to establish a self-sustaining, market-driven program, demonstrating the value of energy efficiency to other building owners. The increasing value of properties across the state will help incentivize these owners to continue upgrades after the grant period has ended. Targeting urban areas in Maine with dense clusters of multifamily units—such as Portland, Lewiston- Auburn, Bangor, and Augusta—MEP engaged a variety of stakeholder groups early on to design its multifamily program. Through direct emails and its website, program officials invited lending institutions, building professionals, engineering firms, equipment distributors, and local property owners associations to attend open meetings around the state to learn about the goals of the multifamily program and to help define its parameters. These meetings helped program administrators understand the diversity of the customer base: some owners are individuals with a single building, while other owners are groups of people or management companies with an entire portfolio of multifamily buildings. The diversity of the customer base notwithstanding, owners see MEP as an opportunity to make gains in their respective properties. Consistently high turnouts at stakeholder meetings fueled greater customer interest as awareness of the program spread through word of mouth. The program also gained traction by utilizing the program partner networks and building on the legacy of the Trust’s successful HESP for single-family residences. MEP offers significant incentives for building owners to participate in the upgrade program. Wholebuilding benchmarking services are available to most multifamily housing buildings free of charge. The service provides the building owner with an assessment of the building's current energy efficiency as compared to other multifamily buildings on a national scale, establishes a baseline to measure future improvements, and enables owners to track monthly energy consumption using the ENERGY STAR Portfolio Manager. Once the benchmarking process is complete, the program links building owners with approved program partners (e.g., energy professionals, home performance contractors) to identify and implement specific energy-saving opportunities in the building. Program partners can also provide project quotes with estimated financing incentives and payback period calculations that enable building owners to make informed decisions. What's more, the Trust provides two financial incentives for successful completion of program milestones. The first is a per-unit incentive for completion of an approved ERP (i.e., $\$$100 per unit if a prescriptive path is followed, and $\$$200 per unit for a modeled ERP). Upon final inspection of the installed project scope of work, an incentive of $\$$1,400 per unit or 50% of installed cost—whichever is less—is paid. The Trust originally established a $\$$1 million loan-loss reserve fund (LLRF) to further enhance financing opportunities for qualified multifamily building owners. This funding mechanism was designed to connect building owners with lenders that retain the mortgages for their properties and encourages the lenders to offer financing for energy efficiency improvements. However, there has been no interest in the LLRF and therefore the LLRF has been reduced. Ultimately, MEP plans to build an online tool for building owners to assess opportunities to make upgrades in their multifamily units. The tool will include a performance rating system to provide a way for building owners to more easily understand energy use in their building, and how it could be improved with energy efficiency upgrades. Prospective tenants will also be able to use the rating system to make informed decisions about where to rent. Furthermore, the rating can be incorporated into real estate listings as a way for prospective home buyers and the real estate financial community to evaluate a home's operating costs. The Trust’s MEP has identified the state's most experienced energy professionals, vendors, suppliers, and contractors that install energy efficiency equipment in the multifamily sector to be qualified program partners. To be eligible for partnership, energy assessment professionals and contractors are required to have demonstrated experience in the multifamily sector and hold associated professional certifications, such as Building Operator Certification (BOC), Certified Energy Manager (CEM), Professional Engineer (PE), or Building Performance Institute (BPI) Multifamily Building Analyst. Widespread program interest has enabled the Trust to redirect funds that might otherwise be needed for program promotion to building capacity through contractor training. In addition to boosting professional training and certification opportunities, MEP teaches its partners how to market the multifamily program to prospective multifamily homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the effects of changes in new source review on national SO{sub 2} and NOx emissions from electricity-generating units

The Clean Air Act establishes New Source Review (NSR) programs that apply to construction or modification of major stationary sources. In 2002 and 2003, EPA revised its rules to narrow NSR's coverage of renovations. Congress mandated a National Research Council study of the revisions' impacts. In that study, we used an electricity-sector model to explore possible effects of the equipment replacement provision (ERP), the principal NSR change directed at power plants. We find that, assuming implementation of the Clean Air Interstate Rule (CAIR), tight enforcement of the prerevision NSR rules would likely lead to no or limited decreases in national emissions compared to policies such as ERP. However, emissions might shift forward in time because the previous NSR rules would depress allowance prices, discouraging banking and encouraging allowance use. Only under the most aggressive prerevision NSR enforcement scenario, in which essentially all coal capacity is compelled to retrofit controls by 2020, do NOx emissions fall below ERP levels. Even then, total 2007-2020 SO{sub 2} emissions are unaffected. Further decreases in national emissions could be accomplished more cheaply by tighter emissions caps than through NSR because caps provide incentives for efficient operating strategies, such as fuel switching, as well as retrofits. 23 refs., 2 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Risk-Informed Analysis for an Enhanced Resilient PWR with ATF, FLEX, and Passive Cooling

This report documents the activities performed by Idaho National Laboratory (INL) during the fiscal year (FY) 2019 for the DOE Light Water Reactor Sustainability (LWRS) Program, Risk-Informed System Analysis (RISA) Pathway, Enhanced Resilient Plant (ERP) Systems research. The purpose of the RISA Pathway research and development is to support plant owner-operator decisions with the aim to improve the economics, reliability, and maintain the high levels of safety of current nuclear power plants over periods of extended plant operations. The concept of ERP refers to the combinations of Accident Tolerant Fuel (ATF), optimal use of Diverse and Flexible Coping Strategy (FLEX), enhancements to plant components and systems, and the incorporation of augmented or new passive cooling systems, as well as improved fuel cycle efficiency. The objective of the ERP research effort is to use the RISA methods and toolkit in industry applications, including methods development and early demonstration of technologies, in order to enhance existing reactors safety features (both active and passive) and to substantially reduce operating costs through risk-informed approaches to plant design modifications to the plant and their characterization. The FY 2019 efforts documented in this report is an extension of those conducted in FY 2018. The same analysis process, risk analysis approaches, and analysis tools as in FY 2018 are used for near-term ATF cladding [i.e., Iron-Chromium-Aluminum (FeCrAl) cladding and Chromium (Cr) coated cladding] designs under the postulated loss of feedwater (LOFW) and steam generator tube rupture (SGTR) accident scenarios. In addition, FLEX analysis was presented for an overview of FLEX equipment and strategies implemented in nuclear industry after Fukushima accident. A FLEX model was developed and incorporated into the generic SAPHIRE model to assess the risk impact from FLEX. FLEX HRA analysis was performed which suggested an approach to HRA with FLEX strategies. Passive cooling system analysis includes an overview of the DNC system, the RELAP5-3D simulations of the DNC system in selected SBO scenarios, and the evaluation of the DNC system risk impact using the generic PRA model.

99 GENERAL AND MISCELLANEOUS↗

Risk-Informed ATF and FLEX Analysis for an Enhanced Resilient BWR Under Design-Basis and Beyond-Design-Basis Accidents

This report documents the activities performed by the Idaho National Laboratory (INL) during fiscal year (FY) 2020 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk-Informed System Analysis (RISA) Pathway, Enhanced Resilient Plant (ERP) Systems research. The purpose of the RISA Pathway research and development is to support plant owner-operator decisions with the aim to improve the economics, reliability, and maintain the high levels of safety of current nuclear power plants over periods of extended plant operations. The concept of ERP refers to the combinations of accident-tolerant fuel (ATF), optimal use of diverse and flexible coping strategy (FLEX), enhancements to plant components and systems, and the incorporation of augmented or new passive cooling systems, as well as improved fuel cycle efficiency. The objective of the ERP research effort is to use the RISA methods and toolkit in industry applications, including methods development and early demonstration of technologies, in order to enhance existing reactors’ safety features (both active and passive) and to substantially reduce operating costs through risk-informed approaches to plant design modifications to the plant and their characterization. One main focus of the FY 2020 efforts documented in this report was to extend the analyses conducted in FYs 2018 and 2019 for a pressurized water reactor (PWR) to a boiling water reactor (BWR). The same analysis process, risk analysis approaches, and analysis tools as in the previous work for PWR were used for a generic BWR with near-term ATF cladding (i.e., Iron-Chromium-Aluminum [FeCrAl] cladding and Chromium [Cr]-coated cladding) designs under the postulated station blackout (SBO) and medium loss-of-coolant (MLOCA) accident scenarios. In addition, a FLEX model was developed and incorporated into a generic BWR probabilistic risk assessment (PRA) model using the INL-developed software tool, Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), to assess the risk impact from FLEX. The other main focus of the FY 2020 efforts was to advance analysis methods, including developing dynamic approach for FLEX human reliability analysis (HRA) using the INL-developed software tool, Event Modeling Risk Assessment using Linked Diagrams (EMRALD), as well as developing a multicriterion benefit evaluation (MCBE) method for evaluating costs and benefits of safety enhancements in nuclear power plants (NPPs). As a case study, the MCBE method was applied to evaluate the costs and benefits brought by FLEX implementation.

99 GENERAL AND MISCELLANEOUS↗

Assessment of Modeling and Simulation Technical Gaps in Safety Analysis of High Burnup Accident-Tolerant Fuels

The United States nuclear industry is facing a strong challenge to maintain regulatory-required levels of safety while ensuring economic competitiveness to stay in business. Safety remains a key parameter for all aspects related to the operation of light water reactor (LWR) nuclear power plants (NPPs), and it can be achieved more economically by using a risk-informed ecosystem, such as that being developed by the Risk-Informed Systems Analysis (RISA) Pathway under the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program. The LWRS Program is promoting a wide range of research and development activities to maximize both the safety and economically efficient performance of NPPs through improved scientific understanding, especially given that many plants are considering second license renewal. The RISA Pathway has two main goals: The deployment of methodologies and technologies that enable better representation of safety margins and the factors that contribute to cost and safety, and; The development of advanced applications that enable cost-effective plant operation. As part of the RISA Pathway, the Enhanced Resilient Plant (ERP) project refers to an NPP where safety is improved by implementing various measures, such as accident-tolerant fuels (ATF), diverse and flexible coping strategy (FLEX), enhancements to plant components and systems, incorporation of augmented or new passive cooling systems, and utilization of advanced battery technologies. The objective of the ERP research is to use novel methods and computational tools to enhance existing reactors’ safety while reducing operational costs. Many U.S. utilities are targeting implementation of ATFs instead of traditional fuel in the near future since ATFs offer benefits in terms of improved performance and cost savings. The robust properties of ATF make it possible to extend the refueling cycle from 18 to 24 months in addition to the opportunity to use less of fuel. Extensive safety assessments are required to support regulatory requirements and obtain the approvals to use ATFs and the ERP project support the industry by developing novel effective methodologies for safety evaluations. In this project, the technical gaps in the modeling and simulation of the high burnup (HBU) ATF were assessed in terms of the fuel cladding behavior during the postulated accident events. The issues were identified in modeling the cladding deformation, the hydrodynamic change due to cladding deformation and the critical heat flux (CHF). The RELAP5-3D cladding deformation model was assessed by multiple verification tests and validation with the instrumented fuel assembly (IFA) experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗