Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy efficiency, industrial assessment center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Industrial Assessment Center for Energy Efficiency, Smart Manufacturing and Cyber Security of Illinois and Northwestern Indiana Small and Medium Sized Manufacturing Companies and Water Facilities (Final Technical Report)

The University of Illinois Chicago (UIC) established and implemented a U.S. Department of Energy (DOE) sponsored Industrial Assessment Center (IAC) from September 1, 2016 through December 31, 2021. The established UIC IAC focused on providing 1) technical assistance to small and medium-sized enterprises (SMEs) and water and wastewater facilities in Illinois and northwestern Indiana and 2) education and training university students developing the future energy workforce. The technical assessments incorporated energy efficiency, increasing productivity via smart manufacturing, energy management systems, enhancing on-site cyber security practices, and the promotion of DOE best practices and tools. The educational training enabled UIC faculty and staff to provide classroom education, exposure to industry research, multiple targeted training sessions, real world experience with industry professionals, and live training to implement professional grade audits and recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of US Industrial Assessment Centers (IACs) implementation

Industrial energy assessments are a fundamental action toward developing a decarbonization strategy at any level. They provide an understanding of where energy efficiency opportunities exist and help to make informed business decisions about the costs and benefits of implementing sustainable policies and practices. This paper examines the effectiveness of the Department of Energy's Industrial Assessment Centers Program at providing useful energy-efficiency audits as well as the barriers faced by the program and plans for future growth and improvement. This paper presents an analysis of the program between 1981 and 2022, covering 20,290 industrial assessments and 151,198 recommendations, with $2.6 billion of recommended savings. The analysis includes a breakdown of the IAC recommendations and implemented projects based on both the industrial subsectors according to the Standard Industrial Classification code, energy type, and systems evaluated. The results include a 47 % implementation rate, a gap analysis to understand the missed opportunities, and a discussion about reasons for recommendation rejection. A comparison of the IAC Program with other country-level energy auditing or assessment programs was conducted, and suggestions for improving implementation rates were mentioned.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

University of Miami Industrial Assessment Center (Final Scientific/Technical Report)

The University of Miami Industrial Assessment Center (MIIAC) is located at the Department of Industrial & Systems Engineering in the College of Engineering at University of Miami. The Center has conducted 402 energy assessments with estimated Total Energy Savings over $\$57.3$ million, Total Non- Energy Cost Savings of $\$23.7$ million, and Total Energy Saving as a 26% of Energy Costs of $\$311$ million. A total of 6.01 TBtu of energy savings were recommended as a result of energy efficiency measures resulting in $\$81$ million in cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UF Industrial Assessment Center - Budget Periods 2017-2021. Final Report

This report summarizes the work performed at the University of Florida’s Industrial Assessment Center (UF-IAC) during the five budget periods (BPs) in the years 2017 through 2021 under DOE Award No. DE-EE0007707. The objective of the work is to perform industrial assessments to small- and medium-sized manufacturing facilities in the State of Florida and to train students in industrial energy management and in performing industrial assessments. Specific details about the activities of the UF-IAC (referred to as the Center) during that time can be found in the 20 quarterly reports that were submitted throughout the duration of the contract. The project start and end dates are September 1, 2016 and August 31, 2021, respectively. The project was granted a six-month no-cost extension till February 28, 2022, to accommodate unexpected delays due to the COVID-19 pandemic. This project was performed by the University of Florida (PI: Dr. SA Sherif). The scope of work includes six milestone whose description and outcomes are listed in the Statement of Project Objectives (SOPO).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2022 Louisiana State University (Final Report)

LSU-IAC started in LSU’s College of Engineering in 2016 with funding from the U.S. Department of Energy’s IAC program. Due to the Covid 19 pandemic, the grant end date was extended from 8/31/2021 to 2/28/2022. In the 5-year performance period, LSU-IAC has conducted a total of 67 industrial assessments and trained a total number of 41 students. We have recommended 408 improvement measures with potential energy savings of 58,951,388 kWh and energy cost savings of $6,817,783 if implemented. Of the 41 students trained, 16 received DOE certificates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center for Underserved Delmarva Area

This report summarizes the work done by the Industrial and Training Assessment Center at the University of Delaware under the award number DE-EE0008796. The 38 audits performed during this period (DL0178 – DL0214) happened from October 2019 to October 2022. The facilities audited belong to a total of 27 industry types, according to the Standard Industry Classification (SIC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center Program Final Progress Report

During September 1, 2021 to August 31, 2023 period, the University of Massachusetts’ Industrial Assessment Center completed 36 industrial assessments at plants across New England. Total annual sales for those plants, which employed 2,664 people, were close to $1.15 billion. Our 212 recommendations amounted to potential savings of $7,069,352, which represented 24.14% of the total energy costs these facilities incurred.

Industrial Assessments Energy Efficiency Student T↗

West Virginia University Industrial Assessment Center (Final Progress Report)

The Industrial Assessment Center at West Virginia University has been successful in workforce development, and in generation of energy savings for manufacturing facilities during the period 2016 to 2021. Graduate and undergraduate students have benefited from energy assessment experience and most of them have found good positions as energy engineers and analysts in the industrial sector. Several peer reviewed research papers in archival journals as well as conference papers on the topic of energy engineering and assessment have been published. The implemented energy savings for manufacturing facilities have been significant in the areas of lighting, compressed air, process heating, steam, HVAC, chillers and cooling towers, and motors. In addition, water use reduction, smart manufacturing applications to save energy, cyber security evaluation, energy management, productivity improvements and waste reduction opportunities that lead to energy intensity reductions have been explored. The students have obtained an opportunity to interact with energy efficiency and productivity improvement professionals at various conferences and workshops and their research has generated important results. In summary, the West Virginia University Industrial Assessment Center (WVU-IAC) has fulfilled its mission in regard to workforce development, energy efficiency for manufacturing facilities, and laid a strong platform enhancing sustainability through reductions in carbon emissions achieved through energy efficiency and energy management initiatives and reductions in water usage and waste reduction. During the project period (2016-2021) the WVU-IAC has made numerous energy efficiency, water use reduction, waste reduction, and productivity improvement recommendations, a significant number of them having been implemented by the manufacturing facilities. The research adds significant understanding to the area of energy efficiency, water and waste reduction, and productivity improvement. The technical effectiveness and economic feasibility of the methods and techniques investigated and demonstrated through this project have been exemplary, resulting in significant recommended and implemented resource savings and reductions in carbon emissions. The project has been of significant benefit to the public owing to replication of results within the industrial sector, thus reducing operating costs for businesses that result in increase of growth and employment, as well as community benefits in terms of reductions in carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency for the growing South Carolina manufacturing industries. Final Report

The overall goals of the proposed project were to establish a DOE Industrial Assessment Center with Clemson University as the main center and to cement the Clemson IAC as the "go to" resource for energy efficiency expertise and assistance to manufacturing businesses in the state of South Carolina. The Clemson IAC included a satellite support center through partnership with the SCE&G Energy Innovation Center at the Clemson University Restoration Institute (CURI) in North Charleston, SC. The Clemson IAC was the first IAC based in the state with the goal to serve the entire state. The Clemson IAC provided SMEs with no-cost energy assessments, trained the next generation of energy-savvy engineers, and provided outreach to non-participating SMEs. Project objectives were structured into five 12-month Budget Periods. In the first Budget Period, the primary objective was to establish methods and materials for Clemson IAC assessments, training, and outreach. In the remaining Budget Periods, the primary objectives were to perform assessments, train students, and pursue outreach to hard-to-reach SMEs that did not participate in energy assessments. Expected outcomes in the first Budget Period included the development of standard procedures for performing energy assessments, including data acquisition, processing, and communication both within the team and in assessment reports prepared for SMEs. Outcomes related to student training in the first Budget Period included detailed curriculum and internship plans for students pursuing the DOE IAC Certificate and energy-related Clemson University certificates. Outcomes in the first Budget Period also included the development of outreach materials and plans for outreach events. In Budget Periods 2 through 5, major expected outcomes are trained students and completed energy assessments and reports for SMEs. Decision points and Go-No Go criteria for the end of each Budget Period, presented in more detail below, are based on the number of students in training and the number of energy assessments performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Syracuse University Industrial Assessment Center (Final Report)

Syracuse University Industrial Assessment Center (SU-IAC) project is focused on the two primary objectives: (i) educate undergraduate and graduate students in engineering and associated disciplines on the concepts of energy sustainability and to provide hands-on training by performing energy assessment at industrial facilities to become future energy efficiency experts, and (ii) offer energy assessments to small and mid-sized manufacturing companies in SU-IAC 2 the greater New York State region, perform analytical engineering work in support of assessment recommendations, and to report the results of those analyses to the client companies, to DOE, and to Field office personnel Through this project period, SU-IAC successfully trained 77 engineering students who were undergraduate or graduate students at Syracuse University College of Engineering, or at SU- IAC’s satellite center at Clarkson University. Each of these students received comprehensive ‘in-class’ technical training, safety training, and hands-on field training. The students performed various tasks related to energy assessment at the manufacturing facilities, including billing analysis, energy use reduction recommendations, and report preparation. Through this project period, a total of 34 students have completed all requirements of the SU-IAC program and have received the US DoE Certificate on Energy Efficiency, with the remaining students continuing at various stages of field work or training. During this project period, due to Covid-related measures in New York State, Syracuse University campus and most of the manufacturing facilities were completely closed or were under severe restrictions for access, for an extended period from March 2020 through April 2021. The closures affected our project execution, with the project Sponsor offering structured relief to carry-out a modified project during the affected budget periods. During this project period, SU-IAC student teams, led by its Director, completed a total of 77 energy assessments at small- and medium-scale manufacturing facilities located in New York State. For these facilities, SU-IAC prepared and presented details for 569 assessment recommendations (ARs). The facilities implemented a total of 258 of these ARs, realizing annual average energy savings in the range of $\$ $3,300 to $\$ $55,000 per facility. Cumulatively, these facilities have reduced their “first year after implementation” energy use by a total of 4.37 million kwh, and fuel use by a total of 27.7 billion BTU. SU-IAC project has successfully met the two primary objectives (and the associated sub objectives) and helped the manufacturing facilities in New York State achieve quantitative energy use reductions as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center – integration of education and practice. Final progress report

The goal of the DOE’s Industrial Assessment Center (IAC) program is twofold: first, to help US manufacturing competitiveness by providing assessments and recommendations for small and medium-sized enterprises (SMEs) on energy efficiency, productivity, sustainability and competitiveness – including measuring the impacts of these recommendations on reducing greenhouse gas emissions; and second, to address a growing shortage of engineering professionals with applied energy and manufacturing-related skills by training a diverse cross-section of engineering students through hands-on involvement in these assessments. IUPUI has an IAC, which was established in 2011, in the Department of Mechanical and Energy Engineering, Purdue School of Engineering and Technology, IUPUI. The IAC has won the awards twice. We have built the center that has the expertise and infrastructure for quality energy assessments to manufactures and commercial building owners and aligned our current research and teaching activities to the DOE’ training mission with programs to train the next generation of industrial energy efficiency experts, with theory and hands-on experience in conducting energy assessment for small and median manufacturing enterprises. We have made recommendations that have the potential to save about $20M annually. We also initiated research projects to meet DOE priorities, specifically in the areas of smart manufacturing and cybersecurity. On the energy assessment side, the Center has provided energy assessments to 144 qualified companies, primarily located in Indiana. On the training side, the center has trained students in various programs, such as the department’s Bachelor of Science (BS) programs in Mechanical Engineering (ME) and BS in Energy Engineering (EEN), both are ABET accredited engineering programs, as well as a graduate level Energy Management and Assessment certificate program. At the present, the center has trained 95 students, 43 or them received the DOE issued certificates. Research projects were developed within the center to advance energy efficiency related technologies, which provided excellent opportunities for our trainees. The center has also been building a professional network with utilities, Manufacturing Extension Partnership (MEP), government agencies, and manufacturing companies, to increase our client base and promote collaborations. The center received the 2019 Center of Excellence of the Year Award and three students received the “Outstanding Achievement in Energy Engineering by an IAC Student” awards in the past five years.

42 ENGINEERING↗

Net Zero Energy Model for Wastewater Treatment Plants

The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. Herein, this study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Industrial Assessment Center Program (Final Report)

This report summarizes the activities of the Industrial Assessment Center (IAC) at San Francisco State University (SFSU) under the Award No. DE-EE0007705 for the period of October 1, 2016 through September 30, 2021. The work performed under the award and related achievements are summarized per task in the statement of the work in the award.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Midwest Industrial Assessment Center (Final Technical Report)

The Midwest IAC’s prime center was at the University of Missouri (MU) and the satellite center was at Wichita State University, Kansas. During the 5-year period we conducted at least 96 energy assessments, with recommended energy cost savings of $10.3 million of which $6.5 million was implemented savings. The implemented energy savings were 0.63 Terra BTU and CO2 emissions reduction was 400,000 tons. Thirty-five students completed requirements for a certificate of completion from DOE. IAC students received training in cybersecurity basics and application to manufacturing, fundamentals of energy efficiency, ISO50001, smart manufacturing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identifying Opportunities and Recommendations for the Integration of Advanced Reactors for Industrial Heat and Electricity Users

Nuclear power in the United States has been used traditionally to provide baseload electric power to the grid. Advancements in nuclear power to create smaller and safer reactors have renewed interest in nuclear as a source of both heat and electricity for a variety of applications. There is great interest in coupling nuclear reactors with industrial applications because nuclear power is a low carbon energy source that can be utilized for process heating, hydrogen generation, on-site electricity demand, and more. Idaho National Laboratory is developing guidelines to identify and assist industrial heat and electricity decarbonization by integrating with nuclear power plants (NPPs) to provide clean, abundant, and dispatchable energy. Considerations include specific industrial hazards which impact NPP siting, heat transport requirements and associated technologies, and implementation feasibility based on site-specific demand profiles. To assess integration feasibility, facility process models are developed based on real data obtained from a survey of baseline requirements and process information from industrial facilities in the United States. An assessment of safety and siting requirements is also performed to determine how nuclear industrial pairings could meet licensing requirements for NPPs. In addition, site characterization of an industrial plant is essential to determining the feasibility and suitable integration methods for each industry. Characterization includes facility distance from the nearest population center, site size, rail or water transport availability, and proximity to undeveloped land. These characteristics are important to determine reactor- or industry-side design requirements for safe, efficient operation. The siting and technical data assessment will reveal opportunities for single-use nuclear integration and co-location opportunities for industries to share benefits from a single reactor. In addition to existing facilities, this “energy-park” style cooperation could include new construction like data centers which can cost-share energy investments or provide a stable demand-and-revenue stream to the investor. Deliverables will contain a library of documents and models to guide various industries toward understanding nuclear technologies based on their users’ needs. This paper is a summary of the current project status, and provides insights on suitable pairings for specific industries and reactor technologies

22 GENERAL STUDIES OF NUCLEAR REACTORS↗