Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

Equitable Design of Behind-the-Meter Energy Storage Programs: A Customer Perspective

Utility deployment of energy storage is done as a utility-scale asset connected directly to the grid (front of meter) or in partnership with a customer on the customer’s premises (behind the meter). By offering incentives for customers to install behind-the-meter storage, utilities can gain operational control of the assets and operate them in a manner that benefits all customers. Some states have also begun providing increased incentive levels to low-income customers to ensure that they can equitably share in the benefits of behind-the-meter energy storage programs. This paper evaluates different approaches to energy storage procurement from the customer’s perspective and evaluates how behind-the-meter programs can be equitably structured while keeping customers financially indifferent between front-of-meter and behind-the-meter energy storage procurements.

Twitchell, Jeremy B.↗

Alternative Approaches to Traditional Net Energy Metering

Most jurisdictions in the United States originally implemented net energy metering (NEM) tariffs to support the deployment and interconnection of distributed generation (DG) resources (e.g., rooftop solar photovoltaic systems). Since then, NEM has proven effective in promoting adoption of DG resources. Recently, due to concerns about sufficient recovery of utilities’ revenue requirements and cost-shifting, there is increasing interest in—or statutory requirements to pursue—alternative compensation approaches, especially in U.S. states and territories with robust growth in distributed solar. Recent increases in other forms of distributed energy resources (DERs) that can potentially send power to the distribution grid (e.g., distributed battery energy storage system (BESS)) are further driving compensation reforms. This brief provides an overview of design elements associated with alternative approaches to traditional NEM, summarizes common arguments for and against them, and identifies implementation issues that utilities may need to address. Although this brief may be most useful in jurisdictions that are interested in or required to move beyond NEM, it is also applicable to those jurisdictions that have already done so—and are looking to further implement reforms to their existing compensation mechanisms. In the broadest sense, there are three primary tariff-related components when interconnecting a DER onto the local utility’s distribution system (adapted from Zinaman et al., 2017): 1. Metering and Billing Arrangements: How utilities measure and bill electricity consumption and production. 2. DER Export Tariff Design: The structure under which utilities compensate customers for electricity they export to the grid. 3. Consumption Tariff Design: The structure under which customers pay for electricity they consume from the grid. When implementing changes to any of these primary tariff-related components, there are likely implications for a utility’s metering system, billing system, and other technology systems. Where applicable, this brief explicitly identifies such implementation challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Calculating Behind-the-Meter Energy Storage Incentives on an Avoided Cost Basis

Behind-the-meter (BTM) energy storage offers the potential for shared investment by utilities and their customers, in which both parties share in the costs and benefits of battery investment. Several utilities and a handful of states have begun providing incentives to help customers purchase BTM energy storage, and in exchange, operate that battery on behalf of the customer to realize grid benefits such as meeting peak capacity needs. But there is wide variation in the value and structure of these incentives, suggesting a lack of clarity on the value of BTM storage to the grid and to non-participating customers who fund the incentives for participating customers. This paper provides an objective framework for establishing BTM energy storage incentives based on the avoided cost of generation from a marginal, gas-fired peaking plant. It also conducts several sensitivity analyses to see how those avoided costs vary with emissions pricing, gas prices, plant heat rates, and utility capital structures. This work may be of use to utilities, regulators, and energy system stakeholders in providing a value-based framework for BTM incentive programs that can be used in the absence of policy guidance.

Twitchell, Jeremy B.↗

Parallel derivative-free optimization for simulation-based design of behind-the-meter energy systems

In this work, the integrated design and dispatch of behind-the-meter or distributed resources (e.g. stationary battery storage and solar PV generation) is considered. A simulation-based framework is employed, generating high-fidelity results with closed-loop predictive control at a fine resolution, at the expense of high computational cost (several minutes to a few hours per design point). To address this challenge, parallel derivative-free design methods are considered. Four methods are compared, including state-of-the-art surrogate-based methods (Radial-Basis Functions and Gaussian processes) and sampling strategies, an evolutionary-based method, and a simple sequential grid refinement method. As a case study, two types of design problem with increasing complexity are considered, namely, the design of behind-the-meter resources (three design variables) and the inclusion of grid capacity (four design variables). The second yields a constrained design problem for which violations can only be determined after solving the computationally expensive simulation. For the three-dimensional case, all methods present a good performance, achieving a solution within 1% of the optimum after the first iteration, with the sequential grid refinement exhibiting the fastest convergence and achieving the best final objective value. This indicates that the parallel evaluation of multiple sampling points may be more important than the choice of method for small decision spaces. For the four-dimensional constrained case, the Genetic Algorithm presents the best tradeoff between performance and computational effort, while the rough objective function terrain generated by constraint violation penalties reduces the performance of surrogate-based methods. Contour plots with flat regions indicate flexibility in the optimal design and highlight the importance of characterizing the solution space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Check the Storage Stack: Comparing Behind-the-Meter Energy Storage State Policy Stacks in the United States

A variety of studies and disparate datasets track state energy storage polices, but these datasets do not cover all BTM-related storage policy. Moreover, these databases do not align these policies with the policy stacking framework. Thus, it is unclear what BTM storage policies are adopted across the country, what should comprise a complete storage policy framework or stack, and how states policies compare against that stack. This report addresses this gap in the literature by developing a state policy stack for BTM battery storage that we compare across all fifty states. This first-of-its-kind BTM storage policy stack includes 11 parent policy categories, and 31 associated policies divided across the market preparation, creation, and expansion policy components.

25 ENERGY STORAGE↗

Technoeconomic Prefeasibility Analysis of Behind-the-Meter Energy Resources for Punta Gorda, FL

The Energy to Communities (E2C) program is a U.S. Department of Energy (DOE)-funded technical assistance program designed to provide technical support to communities transitioning to clean energy and more sustainable energy economies. One offering under E2C is the "Expert Match" technical assistance program, through which DOE national laboratories and other partners provide 40–60 hours of technical support on a topic where expert assistance is critical to the community making an informed clean energy decision.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Towards Non-Intrusive Real-Time Monitoring of Behind the Meter Residential Distributed Energy Resources

The growing adoption of residential distributed energy resources (DERs) introduces more uncertain variability in power grid operation. More importantly, the residential DERs operate behind customers’ energy meters, and therefore, the utility cannot “directly” monitor them. Prior approaches to enable visibility into behind-the-meter (BTM) DERs either depend on estimations or require intrusive instrumentation on the customer side. To address the critical need for direct real-time monitoring of BTM DERs, in this paper, we propose a novel approach for utility-side direct real-time monitoring of residential BTM DERs. We utilize high-frequency (> 10kHz) conducted electromagnetic interference (EMI) from residential DERs’ grid-tied inverters to monitor their power generation. We discuss the working principle of our approach and present supporting results using three of-the-shelf grid-tied inverters.

14 SOLAR ENERGY↗

A Novel Resilience-Oriented Cellular Grid Formation Approach for Distribution Systems with Behind-the-Meter Distributed Energy Resources

This paper presents a resilience-oriented cellular grid formation approach to achieve scalable and reconfigurable community microgrid operations for distribution systems with behind-the-meter distributed energy resources. A set of interconnected solar photovoltaics, energy storage systems, and load is termed as a cell, implying a subset of the grid that can operate independently using its own resources. Cells are identified such that each cell inherently has sufficient energy resources to black start and can provide a certain level of backup power for its load under the loss of utility power supply. The proposed cell formation approach builds on a unique self-organizing map-based method (SomRes) to quantify a system's resilience. Using SomRes and a non-dominated sorting-based genetic algorithm (NSGA-II), a fast and efficient cell formation algorithm is developed to identify cells in a distribution system that are resilient against extreme events. The efficacy of the proposed approach is demonstrated on a numerical model of a real distribution feeder in Colorado, United States.

distributed energy resource↗