Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical signals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Glioblastoma cell migration is directed by electrical signals

Electric field (EF) directed cell migration (electrotaxis) is known to occur in glioblastoma multiforme (GBM) and neural stem cells, with key signalling pathways frequently dysregulated in GBM. One such pathway is EGFR/PI3K/Akt, which is down-regulated by peroxisome proliferator activated receptor gamma (PPARγ) agonists. We investigated the effect of electric fields on primary differentiated and glioma stem cell (GSCs) migration, finding opposing preferences for anodal and cathodal migration, respectively. We next sought to determine whether chemically disrupting Akt through PTEN upregulation with the PPARγ agonist, pioglitazone, would modulate electrotaxis of these cells. We found that directed cell migration was significantly inhibited with the addition of pioglitazone in both differentiated GBM and GSCs subtypes. Western blot analysis did not demonstrate any change in PPARγ expression with and without exposure to EF. In summary we demonstrate opposing EF responses in primary GBM differentiated cells and GSCs can be inhibited chemically by pioglitazone, implicating GBM EF modulation as a potential target in preventing tumour recurrence.

60 APPLIED LIFE SCIENCES↗

Electrical signaling in fungi: past and present challenges

Abstract Electrical signaling is a fundamental mechanism for integrating environmental stimuli and coordinating responses in living organisms. While extensively studied in animals and plants, the role of electrical signaling in fungi remains a largely underexplored field. Early studies suggested that filamentous fungi generate action potential-like signals and electrical currents at hyphal tips, yet their function in intracellular communication remained unclear. Renewed interest in fungal electrical activity has fueled developments such as the hypothesis that mycorrhizal networks facilitate electrical communication between plants and the emerging field of fungal-based electronic materials. Given their continuous plasma membrane, specialized septal pores, and insulating cell wall structures, filamentous fungi possess architectural features that could support electrical signaling over long distances. However, studying electrical phenomena in fungal networks presents unique challenges due to the microscopic dimensions of hyphae, the structural complexity of highly modular mycelial networks, and the limitations of traditional electrophysiological methods. This review synthesizes current evidence for electrical signaling in filamentous fungi, evaluates methodological approaches, and highlights experimental challenges. By addressing these challenges and identifying best practices, we aim to advance research in this field and provide a foundation for future studies exploring the role of electrical signaling in fungal biology.

Buffi, Matteo↗

Electrical signal transmission in a bone cell network: the influence of a discrete gap junction

A refined electrical cable model is formulated to investigate the role of a discrete gap junction in the intracellular transmission of electrical signals in an electrically coupled system of osteocytes and osteoblasts in an osteon. The model also examines the influence of the ratio q between the membrane's electrical time constant and the characteristic time of pore fluid pressure, the circular, cylindrical geometry of the osteon, and key simplifying assumptions in our earlier continuous cable model (see Zhang, D., S. C. Cowin, and S. Weinbaum. Electrical signal transmission and gap junction regulation in a bone cell network: A cable model for an osteon. Ann. Biomed. Eng. 25:379-396, 1997). Using this refined model, it is shown that (1) the intracellular potential amplitude at the osteoblastic end of the osteonal cable retains the character of a combination of a low-pass and a high-pass filter as the corner frequency varies in the physiological range; (2) the presence of a discrete gap junction near a resting osteoblast can lead to significant modulation of the intracellular potential and current in the osteoblast for measured values of the gap junction coupling strength; and (3) the circular, cylindrical geometry of the osteon is well simulated by the beam analogy used in Zhang et al.

Non-NASA Center↗

Camera shutter is actuated by electric signal

Rotary solenoid energized by an electric signal opens a camera shutter, and when the solenoid is de-energized a spring closes it. By the use of a microswitch, the shutter may be opened and closed in one continuous, rapid operation when the solenoid is actuated.

Neff, J. E.↗

Dynamic Range Enhancement of High-Speed Electrical Signal Data via Non-Linear Compression

Systems and methods for high-speed compression of dynamic electrical signal waveforms to extend the measuring capabilities of conventional measuring devices such as oscilloscopes and high-speed data acquisition systems are discussed. Transfer function components and algorithmic transfer functions can be used to accurately measure signals that are within the frequency bandwidth but beyond the voltage range and voltage resolution capabilities of the measuring device.

Laun, Matthew C.↗

Acoustic and electric signals from lightning

Observations of infrasound apparently generated by the collapse of the electrostatic field in the thundercloud, are presented along with electric field measurements and high-frequency thunder signals. The frequency of the infrasound pulse is about 1 Hz and amplitude a few microbars. The observations seem to confirm some of the theoretical predictions of Wilson (1920) and Dessler (1973). The signal is predominated by a compressional phase and seems to be beamed vertically. Calculation of the parameters of the charged region using the infrasound signal give reasonable values.

Balachandran, N. K.↗

Electrical signal transmission and gap junction regulation in a bone cell network: a cable model for an osteon

A cable model is formulated to estimate the spatial distribution of intracellular electric potential and current, from the cement line to the lumen of an osteon, as the frequency of the loading and the conductance of the gap junction are altered. The model predicts that the characteristic diffusion time for the spread of current along the membrane of the osteocytic processes, 0.03 sec, is nearly the same as the predicted pore pressure relaxation time in Zeng et al. (Annals of Biomedical Engineering. 1994) for the draining of the bone fluid into the osteonal canal. This approximate equality of characteristic times causes the cable to behave as a high-pass, low-pass filter cascade with a maximum in the spectral response for the intracellular potential at approximately 30 Hz. This behavior could be related to the experiments of Rubin and McLeod (Osteoporosis, Academic Press, 1996) which show that live bone appears to be selectively responsive to mechanical loading in a specific frequency range (15-30 Hz) for several species.

NASA Discipline Musculoskeletal↗

Characterization of fluid inside pipe using multi frequency electrical signal

A multi-frequency signal may be used to induce voltage difference across a portion of a pipe. The voltage difference may be induced to take multi-frequency measurement of impedance characteristics of fluid inside the pipe. The multi-frequency measurement of the impedance characteristic of the fluid inside the pipe may be used to determine a characteristic of the fluid inside the pipe. This may be achieved by active integration of experimental data with high-resolution multi-frequency electrical impedance tomography (MFEIT) modeling.

Chillara, Vamshi Krishna↗

Planetographic clustering of low-altitude impulsive electric signals in the night ionosphere of Venus

This paper presents maps of the locations of electromagnetic signals, presumably caused by lightning, which were observed at 730 Hz during the first three nighttime observing seasons of Pioneer Venus Orbiter when the spacecraft reached altitudes low enough to detect the signals. The maps show that there are specific 'active regions' of enhanced signal occurrence, and that at least some of these active regions appear to remain fixed in planetographic coordinates from year to year.

Russel, C. T.↗

Source locations for impulsive electric signals seen in the night ionosphere of Venus

A mapping of the rate of occurrence of impulsive VLF noise bursts in Venus' dark low altitude ionosphere, which increases rapidly with decreasing altitude, as a function of latitude and longitude indicates enhanced occurrence rates over Atla. In a 30-sec observing period, there are impulsive signals 70 percent of the time at 160 km in the region of maximum occurrence; the occurrence rates, moreover, increase with decreasing latitude, so that the equatorial rate is of the order of 1.6 times that at 30 deg latitude. These phenomena are in keeping with lightning-generated wave sources.

Russell, C. T.↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Arterial pulse wave pressure transducer

An arterial pulse wave pressure transducer is introduced. The transducer is comprised of a fluid filled cavity having a flexible membrane disposed over the cavity and adapted to be placed on the skin over an artery. An arterial pulse wave creates pressure pulses in the fluid which are transduced, by a pressure sensitive transistor in direct contact with the fluid, into an electric signal. The electrical signal is representative of the pulse waves and can be recorded so as to monitor changes in the elasticity of the arterial walls.

Kim, C.↗

Method and Apparatus for Assessment of Changes in Intracranial Pressure

A non-invasive method and apparatus for monitoring changes in intracranial pressure which removes extracranial effects from the measurements. The method and apparatus can include the supplying of a fixed frequency electrical output to a transducer coupled to the patient's head, thereby generating an acoustical tone burst in the patient's head which generates a first echo and a second echo, the first echo reflecting from a first interface in the side of the patient's head coupled to the transducer, and the second echo reflecting from a second interface at the opposite side of the patient's head. The first and second echoes are received by the transducer which can generate a first electrical signal and a second electrical signal, wherein the first and second electrical signals vary in accordance with the corresponding first and second echoes. The counterbalancing phase shifts required to bring about quadrature between each of the first and second electrical signals and the fixed frequency electrical output can be measured, and values for the change in intracranial distance based on the changes in the counterbalancing phase shifts can be obtained.

Yost, William T.↗

Detection of an internal short circuit in a battery

An electrical device comprises a battery cell; a pressure sensor for measuring swelling forces of the battery cell, optionally with voltage, temperature and current sensors, and a battery management system including a controller. The controller executes a program to: (i) determine a reference swelling force corresponding to a reference electrical signal received from the pressure sensor at an earlier reference time, (ii) determine a second swelling force corresponding to a second electrical signal received from the pressure sensor at a later second time, and (iii) determine whether a risk of internal short circuit of the battery cell exists by comparing a reference level of the reference electrical signal and a signal representative of the second electrical signal. When the signal representative of the second electrical signal exceeds the reference level of the reference electrical signal by a threshold amount, a risk of internal short circuit of the cell exists.

Stefanopoulou, Anna G.↗

Method and Apparatus for Characterizing Pressure Sensors using Modulated Light Beam Pressure

Embodiments of apparatuses and methods are provided that use light sources instead of sound sources for characterizing and calibrating sensors for measuring small pressures to mitigate many of the problems with using sound sources. In one embodiment an apparatus has a light source for directing a beam of light on a sensing surface of a pressure sensor for exerting a force on the sensing surface. The pressure sensor generates an electrical signal indicative of the force exerted on the sensing surface. A modulator modulates the beam of light. A signal processor is electrically coupled to the pressure sensor for receiving the electrical signal.

Robert C Youngquist↗

Systems and methods for flexible, high-density opto-electronic arrays

An opto-electronic probe system is disclosed. The probe system has a probe element including at least one microelectrode, with the probe element being implantable in tissue of an anatomy to receive electrical signals generated within the anatomy. A subsystem is included for at least one of generating excitation signals to be used in stimulating the anatomy, or for receiving electrical signals received from the anatomy. An interface portion is included which is in communication with the subsystem for communicating at least one of electrical signals or optical signals indicative of the electrical signals received by the microelectrode.

Patra, Susant↗

Covert laser remote sensing and vibrometry

Designs of single-beam laser vibrometry systems and methods. For example, a method for detecting vibrations of a target based on optical sensing is provided to include operating a laser to produce a laser probe beam at a laser frequency and modulated at a modulation frequency onto a target; collecting light at or near the laser to collect light from the target while the target is being illuminated by the laser probe beam through an optical receiver aperture; using a narrow-band optical filter centered at the laser frequency to filter light collected from the optical receiver aperture to transmit light at the laser frequency while blocking light at other frequencies; using an optical detector to convert filtered light from the narrow-band optical filter to produce a receiver electrical signal; using a lock-in amplifier to detect and amplify the receiver electrical signal at the modulation frequency while rejecting signal components at other frequencies to produce an amplified receiver electrical signal; processing the amplified receiver electrical signal to extract information on vibrations of the target carried by reflected laser probe beam in the collected light; and controlling optical power of the laser probe beam at the target to follow optical power of background illumination at the target.

Maleki, Lutfollah↗