Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Electric energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Battery model for electrical power system energy balance

A model to simulate nickel-cadmium battery performance and response in a spacecraft electrical power system energy balance calculation was developed. The voltage of the battery is given as a function of temperature, operating depth-of-charge (DOD), and battery state-of-charge. Also accounted for is charge inefficiency. A battery is modeled by analysis of the results of a multiparameter battery cycling test at various temperatures and DOD's.

Hafen, D. P.

Recommendations for Establishing Local Rural Electrification Programs Using Photovoltaic Systems [Recomendaciones Para la Implantacidn de Programas Locales de Electrificacidn Rural con Sistemas Fotovoltaicos]

Photovoltaic (PV) technology is becoming one the best options for supplying electricity to rural communities far from electrical networks and which have a small and disperse demand for electricity. As the cost of the technology goes down and its development advances, opportunities for applying it continue to grow. As a result, in the near future we will probably see an increase in massive application programs of this technology in rural Mexico. This document presents some of the most relevant problems needing immediate solution to increase the possibility of success in establishing photovoltaic programs for rural electrification in Mexico. These problems are influenced by economic, technological, engineering, infrastructural, social and political issues. The paper presents the requirements for an industrial center based on PV technology, the accessibility of replacement parts and maintenance service, development of financial solutions, training of the users and introducing norms and technical regulations. The document summarizes the issue of rural electrification in Mexico, emphasizing the low population density in these areas. A brief description is given of photovoltaics showing different configurations that can be utilized for supplying electricity to the rural areas. The issues involved and recommendations for introducing PV systems to the rural area are described.

14 SOLAR ENERGY

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering

A Study of the Aligned-Grid Retarding Potential Analyzer for Electric Propulsion Applications

During the development of energy analyzers for NASA’s Solar Electric Propulsion Plasma Diagnostics Package, detailed studies were performed to compare the benefits and drawbacks of different types of gridded potential analyzers. In particular, modeling and testing were performed on three types of retarding potential analyzer with aligned grids, and one type with unaligned grids. Additionally, a type of gridded energy analyzer was tested. Analyses of the model and test results showed that manufacturing an analyzer with aligned grids required greater precision and knowledge than other analyzers. A properly designed analyzer with aligned grids exhibited superior signal level, acceptance angle control, energy resolution, and compactness compared to an analyzer with unaligned grids. Additionally, the gridded energy analyzer was found to accept a broad range of incidence angles while having superior signal, energy resolution, and compactness compared to retarding potential analyzer with unaligned grid. This article describes the basic design principles deployed in the study, the associated modeling work, and the characterization tests that were performed. The article summarizes the benefits and drawbacks associated with each type of energy analyzer tested.

Electric Propulsion

Center for High-Efficiency Electrical Technologies for Aircraft: Phase I Final Report

Under the University Leadership Initiative (ULI), the Center for High-Efficiency for Electrical Technologies (CHEETA) was established to develop and mature early-stage technologies pertaining to hydrogen-electric power and energy systems for aircraft. In particular, integration of these technologies on an aircraft system is envisioned to leverage the high specific energy content of liquid hydrogen (LH2) with fuel cell energy conversion and an electrically driven ducted fan system to provide an ultra-efficient propulsion drivetrain. For this concept, the LH2 system is not just used as an energy storage mechanism, but also as a cryogen to enable highly efficient superconducting electric systems. The end result of this concept is an integrated aircraft system with a quiet, efficient propulsion architecture that produces zero CO2, NOx, SOx, and particulate matter emissions at the vehicle level.

Hydrogen

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities 2026 Update

Electricity demand from large-load customers such as data centers is projected to grow significantly in the near term. While these large loads play an important role in advancing technology innovation and economic growth in the United States, meeting their energy needs requires utilities and regulators to consider important operational and financial risks, such as insufficient energy supply or underutilized investments, that can impact all customers. This paper builds on similar research published in January 2025, providing an overview of how utilities and regulators are managing these risks through different tariffs, including rate structures and electric service agreements. Regulators, utilities, customers, and other stakeholders can use this paper as a foundation when discussing issues and sharing perspectives on developing or reviewing large-load tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION

Comparison and Application of Battery Modeling Methods for Conceptual Electric Aircraft

Growing interest in design and optimization of electrified aircraft propulsion concepts prompts the need for accurate, flexible, and efficient methods to model battery systems. Presented in this paper are three battery modeling methods that have been used at NASA’s Glenn Research Center, each representing different mathematical or electrical approaches. Thévenin equivalent circuit, normalization, and curve-fitting methods are compared against battery cell test data for the X-57 Maxwell electric aircraft technology demonstrator. The methods are then applied in a simple multidisciplinary optimization context using NASA’s Six-Passenger Electric Quadrotor concept to determine their applicability and performance. The normalization method achieves the highest accuracy for steady and unsteady discharge rates with a voltage mean error percentage of 0.423% and 1.186%, respectively. Optimal quadrotor mission range between the models varies up to 0.5 nmi, identifying current battery modeling methods as a potentially significant contributor to mission analysis error. A set of relevant tools and techniques for conceptual battery modeling are identified in this paper, with conclusions made on the utility of each modeling approach for various design challenges.

power

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY

Power Lane County Electric Grid Handbook

In 2024, Lane Couty was selected to participate in the U.S. Department of Energy’s Energy to Community program. Through the program, National Laboratory researchers from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, and the National Laboratory of the Rockies provide three years of technical assistance to Lane County and their project partners: the Center for Rural Livelihoods, Springfield Utility Board, and Emerald People’s Utility District. The project, named Power Lane County, aims to improve local electric system affordability, reliability and resilience in the face of natural hazards and potentially rising loads. The Power Lane County Electric Grid Handbook establishes a foundational understanding of the energy landscape and electric grid in Lane County to inform community engagement, education, and analysis in future project phases. This document synthesizes public data and utility and stakeholder engagement, including utility interviews to give the reader a comprehensive view of the challenges facing Lane County's electric system and the opportunities to address them

Electricity

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle

An averaging battery model for a lead-acid battery operating in an electric car

A battery model is developed based on time averaging the current or power, and is shown to be an effective means of predicting the performance of a lead acid battery. The effectiveness of this battery model was tested on battery discharge profiles expected during the operation of an electric vehicle following the various SAE J227a driving schedules. The averaging model predicts the performance of a battery that is periodically charged (regenerated) if the regeneration energy is assumed to be converted to retrievable electrochemical energy on a one-to-one basis.

Bozek, J. M.

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources

Battery Cell-to-Pack Scaling Laws for Electric Aircraft

Battery pack gravimetric energy density is one of the most important, yet often miss-estimated design parameters for sizing all-electric aircraft. Proper accounting for thermal, structural, and operational safety margins are frequently lost when extrapolating performance from the cell level to the aircraft level. This paper summarizes the relevant engineering and certification details needed to better account for the penalties associated when assembling battery packs. The relationship between the cell and pack energy density is not linear, as is often assumed. Furthermore, the relationship varies depending on pack requirements, cell chemistry, and architecture. Parametric, high-fidelity models are used to determine optimal battery pack sizes over a range of conditions to better quantify technology scaling effects.

Battery Electric Aircraft