Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Electric Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Foundation Models for the Electric Power Grid

Foundation models (FMs) currently dominate news headlines. They employ advanced deep learning architectures to extract structural information autonomously from vast datasets through self-supervision. The resulting rich representations of complex systems and dynamics can be applied to many downstream applications. Therefore, advances in FMs can find uses in electric power grids, challenged by the energy transition and climate change. This paper calls for the development of FMs for electric grids. We highlight their strengths and weaknesses amidst the challenges of a changing grid. It is argued that FMs learning from diverse grid data and topologies, which we call grid foundation models (GridFMs), could unlock transformative capabilities, pioneering a new approach to leveraging AI to redefine how we manage complexity and uncertainty in the electric grid. Finally, we discuss a practical implementation pathway and road map of a GridFM-v0, a first GridFM for power flow applications based on graph neural networks, and explore how various downstream use cases will benefit from this model and future GridFMs.

AI-based power flow simulation

Voltage stability smart meter for analyzing voltage data and controlling an electrical power source and/or an electric appliance

Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.

Min, Liang

High Power Density, Carbon Neutral Electrical Power Generation for Air Vehicles

The synergistic integration of a Solid Oxide Fuel Cell-Combustor (SOFC-C) with a turbogenerator (TG) will provide a very high fuel-to-electricity conversion efficiency while maintaining high power-to-weight ratio during high-altitude flight. The proposed SOFC-C-TG power generation technology exceeds the REEACH technical performance targets (TPT). This unique concept addresses many of the challenges faced in all electric propulsion-based aviation. The system has high part-load efficiency (more than 65% lower heating value (LHV)) during long cruise times, load following capability, high-power capacity at high altitudes adapting to low temperatures and pressures, rapid startup time of less than 30 minutes (proven with current SOFC technology), high power density (more than 3.2 kW/kg), efficient thermal management, and a foundation for a compact, efficient electrical storage and power generation system (ESPG). The SOFC-C concept achieves the technology targets by reducing the complexity of traditional fuel cell-gas turbine hybrid systems (FC-GT). The SOFC-C does not require heat exchangers and dramatically reduces the balance of plant increasing power density and performance in efficiency. The reduction in mass through elimination of heat exchangers, external reformer, and other components dramatically decreases the overall thermal dampening of the system which enables rapid startup and load following capability. Direct control of the cathode inlet temperature of the SOFC-C enables rapid warm-up of the SOFC tubes with the ability to reach operating temperature and full power in less than 30 minutes.

03 NATURAL GAS

Graph-Based Attention Mechanisms for Solving the AC Optimal Power Flow Problem in Electrical Power Networks

With the increasing complexity and data availability in modern power systems, learning-based approaches to AC Optimal Power Flow (AC OPF) have garnered significant attention. In particular, the structure of smart grids lends itself naturally to graph-based representations, where Graph Neural Networks (GNNs) can capture spatial and relational dependencies. This paper investigates attention-based GNN architectures tailored to heterogeneous graph representations of electric grids. We evaluate two major paradigms: relational attention, which distinguishes between edge types during message passing, and meta-path attention, which captures high-level semantics through multi-hop, typed paths. Using a large corpus of public AC OPF scenarios, we benchmark representative models of each type of attention. Our results demonstrate the benefits of heterogeneous attention-based models in accurately capturing grid dynamics; heterogeneous attention models achieve superior performance in both standard and perturbed settings. The findings highlight the importance of semantic-aware architectures for improving prediction robustness and interpretability in power system applications.

Trigui, Ali [Qubit Engineering Inc.]

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION

Measuring labor productivity dynamics in U.S. industrial and electric power sectors: a case study (2014–2023)

This study proposes a subsystem methodology for measuring labor productivity in the U.S. industrial and electric power sectors by leveraging public data available between 2014 and 2023. Building on Pasinetti’s framework and subsequent developments, the approach employs Vertically Integrated Sectors (VIS) to account for both direct and indirect productivity effects. The novelty of this work is twofold. First, it enables the estimation of productivity trends over time, providing a robust foundation for empirical analysis. Second, it applies the methodology to a case study of the electric generation sector, highlighting its practical relevance. Using data from the Bureau of Economic Analysis, the Bureau of Labor Statistics, and the Impact Analysis for Planning (IMPLAN) tool, the study reveals significant discrepancies between conventional productivity measures and those derived from the VIS approach. Furthermore, the proposed method aligns with the principles of Integrated Energy Systems by capturing the interrelations among generation, distribution, storage, and consumption. This alignment underscores its utility and applications for energy-related policy and planning. Overall, the findings contribute to more precise labor productivity assessments, supporting informed decision-making and future research. Additionally, the method highlights the importance of considering the whole supply chain, providing interrelated metrics for labor productivity which includes both, direct and indirect effects on the final labor productivity metric. By incorporating intersectoral dependencies, this method offers a more comprehensive and accurate measure of labor productivity compared to traditional metrics.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

MCP-eGridGPT (MCP-Enabled Chatbot with Electrical Power System Analysis and Interactive Visualization Tool) [SWR-25-126]

This software is an advanced chatbot system that integrates the Model Context Protocol (MCP) to provide intelligent electrical power system analysis and automated visualization generation. The system enables users to interact with complex electrical engineering tools through natural language, automatically analyzes power system data for voltage violations and grid health assessment, and generates professional interactive HTML dashboards and reports. Key features include dynamic tool discovery from MCP servers, multi-LLM provider support, intelligent data interpretation using large language models, automated chart generation, and a web-based interface for real-time analysis. The software bridges sophisticated electrical engineering analysis with user-friendly interfaces, making power system diagnostics accessible through conversational AI.

Choi, Seong [National Laboratory of the Rockies (N

Energy Equity: From Sociological Concept to Engineering Perspective of Electric Power Systems

The implementation of energy equity has emerged as a pivotal goal of the global energy transition, driven by widespread recognition of energy inequities worldwide. Because energy equity is broadly regarded as a sociological concept rather than an engineering one, the current absence of technical engineering methods necessitates the development of a justified and sound approach to making energy equity an actionable practice in the broader realms of energy, environment, and sustainability. This Perspective discusses different terms related to energy equity and proposes a generalized definition of energy equity from the engineering perspective of electric power systems. To address these challenges related to energy equity, policies in Europe and the U.S. are introduced, although their effectiveness is limited. Further, current energy equity research is classified into four categories: quantifying energy equity, improving equity in the accessibility of electricity, improving equity in the affordability of electricity, and improving equity in the resilience of power systems. Then, we classify the ongoing research challenges in energy equity into two categories, technical challenges and application challenges, and provide corresponding insights. Finally, we discuss equity of resilience or reliability, income disparity, and environmental equity, followed by a summary of this Perspective.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Modeling a High-Temperature Electrochemically Driven Water-Gas-Shift Process Using a Mixed-Conducting Membrane without External Electrical Power

This paper develops a model to predict and interpret the performance of an elevated-temperature, electrochemical, membrane-assisted, water-gas-shift process. The process uses separated feed streams of H 2 O and CO to produce separated streams of H 2 and CO 2 , without an external electrical power source. The dense ceramic membrane is mixed ionic-electronic-conducting (MIEC) gadolinium-doped ceria (GDC) and the porous composite electrodes are Ni-YSZ. At elevated temperature, GDC conducts both oxygen ions and small polarons. The present process uses chemical potential to drive the process. Electrochemical oxidation of CO proceeds within the composite anode and H 2 O reduction proceeds within the composite cathode. At high temperature (e.g., T > 700 °C), GDC has significant electronic leakage in the form of a reduced-cerium small polaron, which supports the charge-transfer reactions. In a typical electrolyzer or fuel cell, this leakage is significantly problematic. However, the present process depends on the leakage current to complete the electrochemical circuit. Model development and validation is based on measured material properties and reactor performance. Potential applications include using CO-rich blast-furnace off gases in steel processing, producing separated streams of H 2 and CO 2 .

Zhu, Huayang

Simplification of the Grid Model and its Impact on the Analysis of Electrical Power Systems

Here, this paper analyzes the impact of the use of Kron reduction on the state variables of a three-phase electrical system, even when it does not meet the necessary conditions for its application. Reduction is applied to a power line model to eliminate the equation corresponding to the neutral conductor of the line. The ATP program is used to model and simulate the behavior of an electrical system considering different degrees of disequilibrium as a reference for the comparison of results. The results show that under certain conditions of disequilibrium the Kron reduction can lead to significant errors in the state variables of the system.

Electric Power Systems

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Site Energy Management System Platform Development

A site energy management system is a critical component of future high-power EV charging hubs. It monitors and supervises all inter-hub operations, coordinates grid interactions, and implements energy management strategies and load-sharing controls at various levels and time scales. This report provides a comprehensive high-level overview and guidelines on the essential elements of such energy management systems. These elements primarily focus on the core functions, architecture, and monitoring aspects of site energy management. The core functions define the grid services and operational objectives that a charging hub is expected to provide and achieve. The architectural section investigates the coordination between hub assets, different control schemes, and their potential benefits and drawbacks. Lastly, the report discusses the needs, types, and functionalities of a monitoring and visualization system.

24 POWER TRANSMISSION AND DISTRIBUTION

Harvesting Subsea Water Motion to Provide Clean Electrical Power

This TEAMER project had three main objectives related to characterizing the performance of a vortex-induced vibration (VIV) marine energy harvesting device called the Whatever Input To Torsion (WITT). The first was to characterize the motion of the WITT device as it vibrates on top of a pipe in a natural tidal flow. The second was to measure how much electricity the WITT device generates when it is deployed on top of a pipe that is secured to the seabed with a lander. The third objective was to measure how much electricity the WITT device generates in the same configuration but with a longer pipe. This TEAMER project succeeded in satisfying the first objective by measuring the motion of the WITT device with an inertial measurement unit (IMU) mounted in the WITT housing. The motion was described by examining changes in the acceleration, pitch, roll, and yaw, and displacement. The frequency of the motion was characterized using spectral analysis. The TEAMER project succeeded in reaching the second objective by measuring the power produced by the WITT. It is reported here as the average and maximum power in hourly intervals. WITT Energy decided to not have us pursue the third objective of testing a longer pipe because the first test was unexpectedly successful at having the system vibrate at the target frequency. A longer pipe would have resulted in a decreased frequency and therefore not have been a useful test. Based on these findings, the decision was made to keep the same pipe length for both tests and improve on other aspects of the test structure that had failed during the first test. The key finding of this TEAMER project is that the WITT is capable of generating electricity in moderate flow speeds when it is in a housing that is attached to a 2.5 m pipe and secured to the seabed by a lander. This report contains the first power values for a VIV instrument that generates electricity from a pendulum swinging at the top of a long pipe. The experiment demonstrated that the vibration frequency of the device varied with the tidal current speed, which changed throughout a given tidal cycle. This meant that the desired peak frequency was not sustained for more than one hour. The success of this TEAMER test provides evidence that continued research in the area of electricity generation from VIV holds promise as a source of marine energy for offshore applications. Future tests should focus on refining the pipe length equations and improving the power take off system of the WITT power electronics. In addition, experiments aimed at expanded testing and evaluation (e.g. longer than one month) are needed to measure the power production at higher tidal current speeds and test the system's durability.

Branch, Ruth A. (ORCID:0000000202356719)

TEAMER – Harvesting Subsea Water Motion to Provide Clean Electrical Power (Abstract)

Power generation from vortex induced vibration (VIV) is an emerging field with new technologies that are just beginning to be field tested. In this TEAMER project, WITT Energy will be field testing the power production of its pendulum system in two different configurations to evaluate its performance. The amount of power produced by a VIV instrument depend on the frequency at which it vibrates. The vibrational frequency is controlled by the device shape and its interaction with the flow velocity. Computer models are used to predict vibration frequencies as a function of flow velocity but they may be inaccurate due to complicated bathymetry and bottom roughness that is not captures by the models. This project will test the WITT VIV device in the Sequim Bay channel over a range of tidal velocities. Two tests will be completed with different pipe lengths that are expected to vary the vibrational frequency and therefore the power produced. PNNL will use an acoustic doppler current profiler (ADCP) to monitor the flow conditions during the tests. These tests will help WITT Energy evaluate how closely field operations follow computer model predictions and how best to configure their device for electricity production.

16 TIDAL AND WAVE POWER

Projected increases in tropical cyclone-induced U.S. electric power outage risk

Abstract While power outages caused by tropical cyclones (TCs) already pose a great threat to coastal communities, how—and why—these risks will change in a warming climate is poorly understood. To address this need, we develop a robust machine learning model to capture TC-induced power outage risk. When applied to 900 000 synthetic TCs downscaled from simulated historical and future climate conditions under a strong warming scenario, we find outage risk in the United States and Puerto Rico is expected to increase broadly by the end of the century, with some states seeing increases of 60% and higher. Further, we discover that rising rainfall rates will play an increasingly important role in TC-induced power outage risk as the climate changes, explaining more than 50% of the projected change in risk in some regions. These insights are important for guiding decision-makers in their future outage risk investment and mitigation plans.

Grid Resilience

Applications of Solid-State Transformers for Electric Power Grid HEMP/GMD Resilience

A high-altitude electromagnetic pulse (HEMP) or geomagnetic disturbance (GMD) can disrupt power grids by inducing low-frequency common-mode (CM) currents. When these currents flow through grounded transformers, they can bias the magnetic core, driving it into saturation and reducing performance or damaging equipment. This work presents a solid-state transformer (SST) to replace vulnerable assets and improve grid resilience. The paper reviews half-cycle saturation in conventional transformers, then describes an SST architecture that neutralizes and redirects CM currents during HEMP/GMD events. A prototype SST is built and validated, demonstrating stable CM-disturbance operation and protection of nearby transformers. Finally, large-scale simulations show how coordinated SST deployment mitigates CM disturbances and strengthens overall grid resilience.

four-leg inverter