Design of Advanced 1MHz, 1mw Three Phase AC to DC Ultra Fast EV Charger (Final Scientific/Technical Report)

This project embarked to create a compact high-density 1MW EV charger. This project reduced the time to charge an EV with ~400 miles of range to two minutes. This EV charger can be leveraged for residential day-to-day customers and also leveraged for commercial large vehicles such as semi-trucks, delivery trucks, and heavy duty off road. EV chargers of this power capability will reduce consumers range anxiety (The worry of running out of charger in an EV before the customer can get to a charger station.) This will help increase the number of EV’s on the road resulting in decreased use of ICE fossil-based fuel vehicles, reduced emission, and reduced dependence on fossil fuels.

42 ENGINEERING↗

Analysis and Overview of Hybrid Wired and Wireless Bi-Directional EV Charger Systems

Here, this paper analyzes and overviews hybrid wired and wireless bi-directional Electric Vehicle (EV) charging systems with a primary focus on resonant compensation methods that enable a unified power conversion architecture. Four compensation configurations based on series–series and LCC–LCC resonant networks are systematically evaluated for both wired transformer-based and wireless coupler-based operation. The analysis examines how coupling conditions, resonant component selection, and auxiliary compensation tuning influence voltage gain characteristics, resonant tank current magnitude and phase, and operating frequency requirements. Normalized frequency-domain results are presented to directly compare reactive current behavior and voltage regulation capability under wired and wireless operating conditions. A 60 kW bi-directional charger case study is used to demonstrate the feasibility of retaining a common hardware platform while accommodating distinct coupling scenarios through compensation tuning rather than structural modification. The presented results provide design-oriented insights into resonant network selection and compensation strategies for scalable and flexible hybrid EV charging systems.

Hybrid↗

Improving EV Charger Resiliency for MW Charging Systems

In this paper, the resiliency of a megawatt-scale EV charging station is investigated. Fault detection and tolerance methodologies are presented, based on monitoring the voltage offsets in DABs and switch-level currents in three-phase inverters, with the goal of maintaining operation at rated power during single faults and at reduced power under multiple fault conditions. To validate the effectiveness of the proposed strategy, simulation results at the rated 1 MW power of the charging station are carried out, followed by controller hardware-in-the-loop (CHIL) experiments on a 250 kW section of the station. The results highlight the feasibility of the integrated fault-tolerant methods for resilient, high-power EV charging infrastructure.

Adib, Aswad [ORNL] (ORCID:000000020997056X)↗

A Novel Three-Phase Oak Ridge AC / DC Converter for Wireless EV Charger Applications

In this paper, a novel three-phase converter is proposed for ac to dc wireless power transfer (WPT) systems for electric vehicle (EV) charging applications. The proposed innovative solution, called as Oak Ridge Converter, reduces the design complexity and cost by eliminating the front-end converter stage compared to the conventional systems. Additionally, grid side requirements can be met with the proposed creative concept. In this concept, the three-phase single-stage Oak Ridge Converter directly converts the 60 Hz grid frequency into high-frequency voltage and utilizes hybrid grid-source and high-frequency to realize power transfer from AC source through resonant network and coupling coils to the battery load. Simulation validation of the proposed three-phase system is currently being carried on and the results will be will be provided to validate the theoretical studies with the input of 277 VAC,RMS and output of 675 VDC at 35 kW power. The system current total harmonic distortion (THD) is measured 5% with a power factor (PF) of 0.98 and overall hardware development of the system that will be used for experiments is presented.

Asa, Erdem↗

A New Configuration of Paralleled Modular ANPC Multilevel Converter Controlled by an Improved Modulation Method for 1 MHz, 1 MW EV Charger

In this work, a new configuration of the modular multilevel converter (MLC) based on the parallel connection of three-level active-neutral-point-clamped (3L-ANPC) cells as well as its improved modulation method is proposed for 1 MHz, 1 MW electric vehicle (EV) megacharger. In the proposed paralleled modular ANPC-MLC, only six high-frequency silicon carbide (SiC) power switches operating at 333 kHz are required to generate 1 MHz switching frequency spectrum. Moreover, the operating voltage of all power devices is halved, the magnitude of the first switching frequency harmonic cluster is decreased by the factor of five, and the load current is equally distributed between the 3L-ANPC legs by employing the proposed improved modulation method. Hence, the modularity, efficiency, and power density of the proposed converter are notably increased, whereas the value of passive components and the overall switching loss are remarkably decreased. In addition, an optimized design of the one 3L-ANPC cell of the proposed paralleled modular ANPC-MLC for 1 MHz, 1MW EV megacharger using Ansys SIwave, Icepak, and Q3D finite element method platforms is presented and analyzed in detail. The provided experimental results of the down-scaled setup verify the feasibility and viability of the proposed configuration as well as its improved switching pattern.

42 ENGINEERING↗

Automated Controller Hardware-In-The-Loop Testbed for EV Charger Resilience Analysis

This paper focuses on the development of a tool that includes an automated testbed with controls, protection, and communications integrated into a real-time system to provide a platform to generate data sets for failure modes and effects analysis. This tool establishes a value for automation of data generation for different scenarios and addresses the gap of nonexistent field data for different applications and use cases. The features of this tool can further be expanded to include multiple power electronics models, communication protocols, and scaled system architectures. This general framework was evaluated for a DC fast charger system use case to provide quantitative solution for resiliency.

Starke, Michael↗

Using Mapping Tools to Prioritize Electric Vehicle Charger Benefits to Underserved Communities

Mapping tools can play an important role in incorporating equity into planning, implementing, and evaluating investments in electric vehicle (EV) charging stations, also referred to as EV chargers or electric vehicle supply equipment (EVSE). Federal, state, and local organizations need methodologies for using mapping tools as they pursue equity-focused goals to ensure that the benefits of investments in EV chargers flow to energy and environmental justice (EEJ) underserved communities. This report provides examples of how to apply mapping tools to identify priority locations for installing EV chargers that may benefit EEJ underserved communities through four EV charger planning approaches: corridor charging, community charging, fleet electrification, and diversity in STEM and workforce development. It also explores various methodologies for calculating low-public EVSE density. Ensuring that the benefits of EV charger investments flow to underserved communities involves prioritizing locally identified needs and incorporating community input when choosing charging station locations. Installing EV chargers in a census tract identified as an EEJ underserved community does not inherently mean that those EV chargers provide benefits to residents of that community. In addition, representatives of historically disadvantaged communities or environmental justice communities have concerns that installing EV chargers in their communities could potentially exacerbate or propagate existing inequities. While the methodologies described in this report may help identify priority census tracts for equity-focused EV charger investment, additional community engagement and site evaluation are necessary to determine whether EV chargers are accessible, affordable, and convenient to EEJ underserved community residents and what benefits the local community is looking to realize with EV charger installations. This report is the culmination of many discussions with project leaders from DOE-funded projects deploying EV chargers in communities across the nation, organizations representing EEJ underserved communities, state agencies developing EV investment plans, utilities making major EV investments, and DOE national laboratory experts working in transportation electrification. The authors distributed a draft report for peer review, and reviewer comments are summarized in this report. These methodologies are likely to evolve as more EV charger funding programs are implemented and more real-world data is available to measure the effectiveness of strategies for incorporating equity in EV charger deployment projects. Continued efforts to document best practices and critically evaluate whether equity-focused programs achieve their goals are needed as transportation electrification proceeds at the local, regional, and national levels.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric vehicle supply equipment location and capacity allocation for fixed-route networks

Electric vehicle (EV) supply equipment location and allocation (EVSELCA) problems for freight vehicles are becoming more important because of the trending electrification shift. Some previous works address EV charger location and vehicle routing problems simultaneously by generating vehicle routes from scratch. Although such routes can be efficient, introducing new routes may violate practical constraints, such as drive schedules, and satisfying electrification requirements can require dramatically altering existing routes. To address the challenges in the prevailing adoption scheme, we approach the problem from a fixed -route perspective. We develop a mixed -integer linear program, a clustering approach, and a metaheuristic solution method using a genetic algorithm (GA) to solve the EVSELCA problem. The clustering approach simplifies the problem by grouping customers into clusters, while the GA generates solutions that are shown to be nearly optimal for small problem cases. A case study examines how charger costs, energy costs, the value of time (VOT), and battery capacity impact the cost of the EVSELCA. Charger equipment costs were found to be the most significant component in the objective function, leading to a substantial reduction in cost when decreased. VOT costs exhibited a significant decrease with rising energy costs. Further, an increase in VOT resulted in a notable rise in the number of fast chargers. Longer EV ranges decrease total costs up to a certain point, beyond which the decrease in total costs is negligible.

33 ADVANCED PROPULSION SYSTEMS↗

Solar Energy Extension Project

The town of Stratford plans to develop and own a 6 kilowatt (kW) solar array on the roof of a municipal-owned public pavilion on the town green. A SolarEdge level 2 EV charging station will be installed at the pavilion to be used by the public. The charging station will have one charging port. The town will install 3 air source heat pumps in the library located adjacent to the pavilion to reduce the use of propane to heat the library. The town will install 4 air source heat pumps in the Town Hall to reduce the use of #2 heating oil to heat the facility. The 6 kW solar array will provide electricity to the library to offset electricity usage, and when an EV plugs into the charging station the solar will provide electricity to the charging station. There is no ground disturbance or ground trenching associated with this project. The 6 kW solar array on the roof of the pavilion will include 20 (390) watt all black panels. A SolarEdge level 2 EV charger will be installed at the pavilion with the 240 V inverter. The solar array will provide electricity to the library and when a vehicle plugs into the EV charger the solar array will switch to power the charger. Any excess electricity that is generated by the array and not used by the library or the EV charger will be fed onto the grid and the town will receive a net metering credit applied towards future consumption. There is no ground disturbance associated with the EV charger or solar array, and the town will install signage to direct the public to the charger. The library will install 2 (18,000) BTU ductless air source heat pumps and 1 (24,000) BTU unit. This will significantly reduce the amount of propane required to heat the library. The Town Hall will install 2 (36,000) BTU ductless air source heat pumps and 2 (9,000) BTU units to reduce the amount of #2 heating oil required to heat the building.

14 SOLAR ENERGY↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Control Strategy for Improving Resiliency of an DC Fast Charging EV System

As DC fast charging electric vehicle (EV) infrastructure continues to expand, potential challenges loom. One issue is the potential for EV charger outages due to electrical grid voltage transients. Today, EV chargers are expected to disconnect under a severe voltage sag (below 70%) which reduces electric vehicle charging infrastructure resilience. This work proposes a droop-control solution to ride-through voltage sags and maintain operation. The control solution is presented in a controller hardware in the loop platform.

Starke, Michael↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

Electric vehicles (EVs) are growing in popularity and gaining meaningful market share with record sales year over year in the last decade. EV charging equipment, also known as EV chargers (EVC) or EV supply equipment (EVSE), must proportionally match the growing number of new EVs on the road for a comparable experience to gas-powered vehicles. The majority of EV charging currently happens at residential buildings. However, demand for EV charging at commercial buildings will significantly increase with wider mainstream EV adoption and as businesses return to more normal operation following COVID-19 pandemic disruptions. Charging equipment can include various sub-systems like power conditioning module, control software, safety devices, metering, communication, cooling, connectors, and its wiring. EV charging at commercial buildings could be used for public, workplace, and commercial fleet charging. This document aims to describe how EVC can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system. More specifically, this resource provides an overview of: understanding EV charging basics: how charging equipment connects to the building and to EVs; required infrastructure updates needed at the building site to connect EVC to existing distribution systems; network strategies for cost-effective operation; metering and utility considerations for billing and incentives; charging equipment ownership options; future trends in EVC connection to buildings.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Improving Resiliency for Electric Vehicle Charging

Electric vehicles are seeing growing adoption. However, challenges with range anxiety persists. While charging infrastructure is anticipated to expand, EV charger systems have not been as robust to challenges. This paper discusses potential outage conditions associated with EV charging and presents new technology in development to improve EV charging resilience.

Electric vehicle charging, electric vehicle chargi↗

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

This factsheet from the National Renewable Energy Laboratory aims to describe how EV chargers can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system.

Better Buildings, electric vehicle charging, comme↗

EV charging site day-ahead load prediction in a synthetic environment for RL based grid-informed charging

Ensuring grid health in the face of increasing demand for power is an emerging challenge especially due to transportation electrification. A free market approach to influencing electric vehicle (EV) load through grid-informed hourly dynamic pricing is introduced in this work. The setting of charging price is done by a reinforcement learning (RL) agent that learns the complicated dynamics by interacting with a synthetic environment. This synthetic environment is a combination of distribution feeder simulation, EV charger user behavior dynamics, and EV charging simulation. A key module in this synthetic environment involves obtaining the day-ahead charging profile of EV charging stations based on real-world past data. The day-ahead prediction is also useful in other traditional optimizations related to EV charge scheduling. The proposed approach involves using EV charging data from two different past time horizons – one to determine the shape of the daily profile and the other to determine a scaling value to capture actual energy consumption. Real-world charging data over many years from the ACN charging network has been used to demonstrate the ability to predict the day-ahead profile with only charge session data. Both Python and MATLAB have been used for data cleaning, processing, analysis, and prediction.

Suryanarayana, Harish↗