Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EV RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ ⁢eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44–52 μ ⁢eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, 𝑔 𝑎⁢𝛾⁢𝛾 , in this mass range at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44 – 52 μ eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, g a γ γ , in this mass range at 90% confidence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results from a Broadband Search for Dark Photon Dark Matter in the 44 to 52 μ eV Range with a Coaxial Dish Antenna

We present first results from a dark photon dark matter search in the mass range from 44 to 52 μ eV (10.7–12.5 GHz) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area 0.5 m 2 and is focused by a novel parabolic reflector onto a horn antenna. Signals are read out with a low-noise receiver system. A first data taking run with 24 days of data does not show evidence for dark photon dark matter in this mass range, excluding dark photon photon mixing parameters χ ≳ 10 − 12 in this range at 90% confidence level. This surpasses existing constraints by about 2 orders of magnitude and is the most stringent bound on dark photons in this range below 49 μ eV . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proposed search for dark-matter axions in the 0.6-16 micro-eV range

A proposed experiment is described to search for dark matter axions in the mass range 0.6 to 16 micro-eV. The method is based on the Primakoff conversion of axions into monochromatic microwave photons inside a tunable microwave cavity in a large volume high field magnet, as described by Sikivie. This proposal capitalizes on the availability of two Axicell magnets from the decommissioned Mirror Fusion Test Facility (MFTF-B) fusion machine at LLNL. Assuming a local dark matter density in axions of rho = 0.3 GeV/cu cm, the axion would be found or ruled out at the 97 pct. c.l. in the above mass range in 48 months.

Vanbibber, Karl↗

Cosmic rays in the 10(16) to 10(19) eV range from pulsars

The flux is calculated of cosmic rays (CRs) produced by a distribution of pulsars that are: (1) born with rapid rotation rates, (2) slow down as they evolve, and (3) produce energetic nuclei with a characteristic energy proportional to their rotation rates. It is found that, for energy independent escape from the disk of the galaxy, the predicted spectrum will be essentially what is observed between approx 10 to the 16th power to 10 to the 19 power eV if the slow down law as inferred for radio pulsars can be extrapolated to young pulsars with shorter periods.

Wandel, A.↗

New limit on dark photon kinetic mixing in the 0.2 – 1.2 μ eV mass range from the Dark E-field Radio experiment

We report new limits on the kinetic mixing strength of the dark photon spanning the mass range 0.21 − 1.24 μ eV corresponding to a frequency span of 50–300 MHz. The Dark E-field Radio experiment is a wideband search for dark photon dark matter. In this paper we detail changes in calibration and upgrades since our proof-of-concept pilot run. Our detector employs a wide-bandwidth E-field antenna moved to multiple positions in a shielded room, a low noise amplifier, wideband analog-to-digital converter, followed by a 2 24 -point fast Fourier transform. An optimal filter searches for signals with Q ≈ 10 6 . In nine days of integration, this system is capable of detecting dark photon signals corresponding to a kinetic mixing strength ε several orders of magnitude lower than previous limits. We find a 95% exclusion limit on ε over this mass range between 6 × 10 − 15 and 6 × 10 − 13 , tracking the complex resonant mode structure in the shielded room. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Optical constants of magnetron sputtered aluminum in the range 17–1300 eV with improved accuracy and ultrahigh resolution in the L absorption edge region

This work determines a new set of EUV/x-ray optical constants for aluminum (Al), one of the most important materials in science and technology. Absolute photoabsorption (transmittance) measurements in the 17–1300 eV spectral range were performed on freestanding Al films protected by carbon (C) layers, to prevent oxidation. The dispersive portion of the refractive index was obtained via the Kramers–Kronig transformation. Our data provide significant improvements in accuracy compared to previously tabulated values and reveal fine structure in the Al L 1 and L 2,3 regions, with photon energy step sizes as small as 0.02 eV. The implications of this work in the successful realization of EUV/x-ray instruments and in the validation of atomic and molecular physics models are also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Chandra Observations of Comet 2P/Encke 2003: First Detection of a Collisionally Thin, Fast Solar Wind Charge Exchange System

We report the results of 15 hr of Chandra observations of comet 2P/Encke 2003 on November 24. X-ray emission from comet Encke was resolved on scales of 500-40,000 km, with unusual morphology due to the presence of a low-density, collisionally thin (to charge exchange) coma. A light curve with peak-to-peak amplitude of 20% consistent with a nucleus rotational period of 11.1 hr was found, further evidence for a collisionally thin coma. We confirm emission lines due to oxygen and neon in the 800-1000 eV range but find very unusual oxygen and carbon line ratios in the 200-700 eV range, evidence for low-density, high effective temperature solar wind composition. We compare the X-ray spectral observation results to contemporaneous measurements of the coma and solar wind made by other means and find good evidence for the dominance of a postshock bubble of expanding solar wind plasma, moving at 600 km/s with charge state composition between that of the "fast" and "slow" solar winds.

Lisse, C. M.↗

Search for Reactor-Produced Millicharged Particles with Skipper-CCDs at the CONNIE and Atucha-II Experiments

Millicharged particles, proposed by various extensions of the standard model, can be created in pairs by high-energy photons within nuclear reactors and can interact electromagnetically with electrons in matter. Recently, the existence of a plasmon peak in the interaction cross section with silicon in the eV range was highlighted as a promising approach to enhance low-energy sensitivities. The CONNIE and Atucha-II reactor neutrino experiments utilize Skipper-CCD sensors, which enable the detection of interactions in the eV range. We present world-leading limits on the charge of millicharged particles within a mass range spanning 6 orders of magnitude, derived through a comprehensive analysis and the combination of data from both experiments. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Primary cosmic ray spectrum in the 10 to the 12th power - 10 to the 16th power eV energy range from the NUSEX experiment

A primary cosmic ray spectrum was derived which fits both experimental multiple muon rates and the all-nucleon flux derived from the single muon intensities underground. In the frame of the interaction model developed by Gaisser, Elbert and Stanev, it is possible to reproduce NUSEX muon data with a primary composition in which the iron spectrum is only slightly flatter than the proton one. This result rules out the popular idea that the primary composition varies drastically with increasing energy, leading to the dominance of heavier nuclei at energies 10 to the 15th power to 10 to the 16th power eV.

Battistoni, G.↗

Expanding the Energy Range from eV to MeV and Fabrication of Sources Enabling Novel Focused Ion Beam Nanofabrication and Modification

Multi-species focused ion beam (FIB) has the capability of running a variety of ion species allowing tailoring of the ion to the application enabling new applications of FIB such as localized doping and the creation of single defect centers. Also, through variation of the ion energy from eV to MeV, specific depths within the sample can be targeted enabling targeting of deeply buried layers inaccessible by traditional FIB systems. The combination of these capabilities opens up new areas of study including quantum information science and 2D materials.

47 OTHER INSTRUMENTATION↗

Equatorially trapped plasma populations

The SCATHA observations of the equatorially trapped plasmas are presented in order to emphasize the importance of making measurements at the equator. The UCSD plasma detector and the GSFC electric field experiment are described, as are the pertinent characteristics of the magnetometer and mass spectrometers. The electron distribution reveals a width of 20 deg to 60 deg, narrowing with increasing energy. The 20- to 100-eV ion fluxes typically exhibit temperatures in the 20to 50-eV range and densities of 1-10 per cu cm. The electron population typically ranges from 50 to 500 eV, with temperatures of 100-200 eV and densities also in the 1-10 per cu cm range. Field-aligned populations of lower energy are occasionally found in both ions and electrons at the same location.

Olsen, R. C.↗

Electronic excitations of α - Fe 2 O 3 heteroepitaxial films measured by resonant inelastic x-ray scattering at the Fe L edge

Resonant inelastic x-ray scattering (RIXS) spectra of hematite (α-Fe 2 O 3 ) were measured at the Fe L 3 edge for heteroepitaxial thin films which were undoped and doped with 1% Ti, Sn, or Zn, in the energy-loss range in excess of 1 eV to study electronic transitions. The spectra were measured for several momentum transfers q, conducted at both low temperature (T=14 K) and room temperature. While we cannot rule out dispersive features possibly owing to propagating excitations, the coarse envelopes of the general spectra did not appreciably change shape with q, implying that the bulk of the observed L-edge RIXS intensity originates from (mostly) nondispersive ligand field excitations. Summing the RIXS spectra over q and comparing the results at T=14 K to those at T=300 K revealed pronounced temperature effects, including an intensity change and energy shift of the ≈1.4 eV peak, a broadband intensity increase of the 3-4 eV range, and higher energy features. The q-summed spectra and their temperature dependencies are virtually identical for nearly all of the samples with different dopants, save for the temperature dependence of the Ti-doped sample's spectrum, which we attribute to being affected by a large number of free charge carriers. Comparing with magnetization measurements for different temperatures and dopings likewise did not show a clear correlation between the RIXS spectra and the magnetic ordering states. To clarify the excited states, we performed spin multiplet calculations which were in excellent agreement with the RIXS spectra over a wide energy range and provide detailed electronic descriptions of the excited states. Furthermore, the implications of these findings to the photoconversion efficiency of hematite photoanodes is discussed.

36 MATERIALS SCIENCE↗

Green Bank and Effelsberg Radio Telescope Searches for Axion Dark Matter Conversion in Neutron Star Magnetospheres

Axion dark matter (DM) may convert to radio-frequency electromagnetic radiation in the strong magnetic fields around neutron stars. The radio signature of such a process would be an ultranarrow spectral peak at a frequency determined by the mass of the axion particle. In this work, we analyze data we collected from the Robert C. Byrd Green Bank Telescope in the L band and the Effelsberg 100-m Telescope in the $\textit{L}$ band and $\textit{S}$ band from a number of sources expected to produce bright signals of axion-photon conversion, including the Galactic center of the Milky Way and the nearby isolated neutron stars RX J0720.4-3125 and RX J0806.4-4123. We find no evidence for axion DM and are able to set constraints on the existence of axion DM in the highly motivated mass range between ~ 5 and 11 μ eV with the strongest constraints to date on axions in the ~10–11 μ eV range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Symmetry Breaking in the Lowest-Lying Excited-State of CCl4: Valence Shell Spectroscopy in the 5.0–10.8 eV Photon Energy Range

We report absolute high-resolution vacuum ultraviolet (VUV) photoabsorption cross-sections of carbon tetrachloride (CCl4) in the photon energy range 5.0–10.8 eV (248–115 nm). The molecular spectrum and electronic structure have been comprehensively investigated together with quantum chemical calculations, providing geometries, bond lengths, vertical excitation energies and oscillator strengths. The major electronic excitations have been assigned to valence and Rydberg transitions which are also accompanied by vibrational excitation assigned to degenerate stretching, v3′t2 and degenerate deformation v4′t2 modes. The rather complex nuclear dynamics along the degenerate deformation mode, v4′t2, have been thoroughly investigated by Time-Dependent Density Functional Theory (TD-DFT) method. The relevant Jahn–Teller distortion operative within the lowest-lying electronic excited-state is shown here for the first time in order to yield a weak absorption feature at 6.156 eV. Further calculations on the potential energy curves for the singlet excited-states along the C–Cl stretching coordinate show the relevance of efficient C–Cl bond excision.

Biochemistry & Molecular Biology↗