Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of Electrospray Ionization (ESI) Parameters on In-ESI Hydrogen/Deuterium Exchange of Carbohydrate-Metal Ion Adducts

The conformations of glycans are crucial for their biological functions. In-electrospray ionization (ESI) hydrogen/deuterium exchange-mass spectrometry (HDX-MS) is a promising technique for studying carbohydrate conformations since rapidly exchanging functional groups, e.g., hydroxyls, can be labeled on the timeframe of ESI. However, regular application of in-ESI HDX to characterize carbohydrates requires further analysis of the in-ESI HDX methodology. For instance, in this method, HDX occurs concurrently to the analyte transitioning from solution to gas-phase ions. Therefore, there is a possibility of sampling both gas-phase and solution-phase conformations of the analyte. Herein, we differentiate in-ESI HDX of metal-adducted carbohydrates from gas-phase HDX and illustrate that this method analyzes solvated species. We also systematically examine the effects of ESI parameters, including spray solvent composition, auxiliary gas flow rate, sheath gas flow rate, sample infusion rate, sample concentration, and spray voltage, and discuss their effects on in-ESI HDX. Further, we model the structural changes of a trisaccharide, melezitose, and its intramolecular and intermolecular hydrogen bonding in solvents with different compositions of methanol and water. These molecular dynamic simulations support our experimental results and illustrate how an individual ESI parameter can alter the conformations we sample by in-ESI HDX. Overall, this work illustrates how the fundamental processes of ESI alter the magnitude of HDX for carbohydrates and suggest parameters that should be considered and/or optimized prior to performing experiments with this in-ESI HDX technique.

Carbohydrate Conformation↗

Molecular Transformation of Dissolved Organic Matter during the Processes of Wildfire, Alum Coagulation, and Disinfection Using ESI(-) and ESI(+) FT-ICR MS

Forest fires alter the quality of terrestrial dissolved organic matter (DOM) flushed into source water, which could be further changed during alum coagulation and serve as potential disinfection byproduct (DBP) precursors in water facilities. To unveil this molecular transformation, we applied 12T Fourier transform ion cyclotron resonance mass spectrometry on a controlled study which used the leachates of black and white ashes (collected immediately after the 2013 Rim Fire, CA) along with unburned white fir (Abies concolor) and ponderosa pine (Pinus ponderosa). Here, results showed that the assigned features in DOM from burned ashes had a smaller molecular weight (MW), contained more unsaturated, aromatic, and oxidized and less fraction of labile compounds, and were enriched with nitrogen, relative to unburned litters. After alum coagulation, we observed the disappeared features with higher MW and S/C and N/C atom ratios than the resistant features. During the following disinfections, the disappeared features serving as the potential DBP precursors had higher MW and unsaturation degree, contained more S- and N-containing functionalities, and were more aromatic, compared to the resistant features. Our study suggested organic compounds with small MW and high aromaticity as the targets for water facilities to improve post-fire drinking water quality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ESIS query environment pilot project

The European Space Information System (ESIS) was originally conceived to provide the European space science community with simple and efficient access to space data archives, facilities with which to examine and analyze the retrieved data, and general information services. To achieve that ESIS will provide the scientists with a discipline specific environment for querying in a uniform and transparent manner data stored in geographically dispersed archives. Furthermore it will provide discipline specific tools for displaying and analyzing the retrieved data. The central concept of ESIS is to achieve a more efficient and wider usage of space scientific data, while maintaining the physical archives at the institutions which created them, and has the best background for ensuring and maintaining the scientific validity and interest of the data. In addition to coping with the physical distribution of data, ESIS is to manage also the heterogenity of the individual archives' data models, formats and data base management systems. Thus the ESIS system shall appear to the user as a single database, while it does in fact consist of a collection of dispersed and locally managed databases and data archives. The work reported in this paper is one of the results of the ESIS Pilot Project which is to be completed in 1993. More specifically it presents the pilot ESIS Query Environment (ESIS QE) system which forms the data retrieval and data dissemination axis of the ESIS system. The others are formed by the ESIS Correlation Environment (ESIS CE) and the ESIS Information Services. The ESIS QE Pilot Project is carried out for the European Space Agency's Research and Information center, ESRIN, by a Consortium consisting of Computer Resources International, Denmark, CISET S.p.a, Italy, the University of Strasbourg, France and the Rutherford Appleton Laboratories in the U.K. Furthermore numerous scientists both within ESA and space science community in Europe have been involved in defining the core concepts of the ESIS system.

Fuchs, Jens J.↗

ESI-MS of Cucurbituril Complexes Under Negative Polarity

Electrospray ionization mass spectrometry (ESI-MS) is a powerful tool to study host–guest supramolecular interactions. ESI-MS can be used for detailed gas-phase reactivity studies, to clarify the structure, or simply to verify the formation of complexes. Depending on the structure of the host and of the guest, negative and/or positive ESI are used. Here we report the unexpected formation of host–guest complexes between cucurbit[n]urils (n = 7, 8, CB[n]) and amine, styryl pyridine, and styryl pyridine dimer cations, under negative ESI. Non-complexed CB[n] form double charged halide (Br{sup -}, Cl{sup -}, F{sup -}) adducts. Under negative ESI, halide ions interact with CB[n] outer surface hydrogen atoms. One to one host–guest complexes (1:1) of CB[n] with positive charged guests were also observed as single and double charged ions under negative ESI. The positive charge of guests is neutralized by ion-pairing with halide anions. Depending on the number of positive charges guests retain in the gas phase, one or two additional halide ions are required for neutralization. Complexes 1:2 of CB[8] with styryl pyridines retain two halide ions in the gas phase, one per guest. Styryl pyridine dimers form 1:1 complexes possessing a single extra halide ion and therefore a single positive charge. Negative ESI is sensitive to small structural differences between complexes, distinguishing between 1:2 complexes of styryl pyridine-CB[8] and corresponding 1:1 complexes with the dimer. Negative ESI gives simpler spectra than positive ESI and allows the determination of guest charge state of CB[n] complexes in the gas phase. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semi-Targeted Analysis of Complex Matrices by ESI FT-ICR MS or How an Experimental Bias may be Used as an Analytical Tool

Ammonia is well suited to favor deprotonation process in electrospray ionization mass spectrometry (ESI-MS) to increase the formation of [M – H]{sup –}. Nevertheless, NH{sub 3} may react with carbonyl compounds (aldehyde, ketone) and bias the composition description of the investigated sample. This is of significant importance in the study of complex mixture such as oil or bio-oil. To assess the ability of primary amines to form imines with carbonyl compounds during the ESI-MS process, two aldehydes (vanillin and cinnamaldehyde) and two ketones (butyrophenone and trihydroxyacetophenone) have been infused in an ESI source with ammonia and two different amines (aniline and 3-chloronaniline). The (+) ESI-MS analyses have demonstrated the formation of imine whatever the considered carbonyl compound and the used primary amine, the structure of which was extensively studied by tandem mass spectrometry. Thus, it has been established that the addition of ammonia, in the solution infused in an ESI source, may alter the composition description of a complex mixture and leads to misinterpretations due to the formation of imines. Nevertheless, this experimental bias can be used to identify the carbonyl compounds in a pyrolysis bio-oil. As we demonstrated, infusion of the bio-oil with 3-chloroaniline in ESI source leads to specifically derivatized carbonyl compounds. Thanks to their chlorine isotopic pattern and the high mass measurement accuracy, (+) ESI Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) unambiguously highlighted them from the numerous C{sub x}H{sub y}O{sub z} bio-oil components. These results offer a new perspective into the detailed molecular structure of complex mixtures such as bio-oils. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PSU ESI Review

A guide to developing an Energy Service Interface (ESI) was created as part of the Grid Modernization Laboratory Consortium 2.5.2 ESI project. The approach applies device-agnostic and service-oriented ESI principles and leverages documents such as the Interoperability Maturity Model and Common Grid Service Definitions to provide a methodology to review, develop, and update standards and profiles to engage distributed energy resources (DER) to provide grid services. This document evaluates the ESI developed by Portland State University’s Power Engineering Group under the Electric Grid of Things project funded by the U.S. Department of Energy. The evaluation explores the compliance of this specific implementation with the GMLC ESI principles to provide an example of an ESI profile and gap analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Characteristics to Eliminate the Need for Parameter Optimization in Nanoflow ESI-MS

The sampling efficiency in electrospray ionization-mass spectrometry (ESI-MS) can be improved by decreasing the liquid flow rate to the nanoflow regime, where it is possible to draw a large fraction of the ESI plume into the mass spectrometer. This mode of operation is typically more difficult than ESI-MS at higher flow rates because it requires careful optimization of a number of parameters to achieve optimal sampling efficiency. In this work, we screened the relative impact on signal intensity and spray stability of factors that included sprayer position, spray electrode protrusion, sprayer tip shape, spray angle relative to the MS inlet, nebulizer gas flow rate, ESI potential, and means for generating the electric field to initiate electrospray. Based on the screening results, we explore the possibility of providing fixed optimal values for many of the key source parameters to eliminate much of the tuning that is required for conventional nanoflow sources. This approach has potential to greatly simplify nanoflow ESI-MS, while providing optimized sensitivity, stability, and robustness, with decreased variability between analyses. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Submicrometer Emitter ESI Tips for Native Mass Spectrometry of Membrane Proteins in Ionic and Nonionic Detergents

Native mass spectrometry (native-MS) of membrane proteins typically requires a detergent screening protocol, protein solubilization in the preferred detergent, followed by protein liberation from the micelle by collisional activation. Here, submicrometer nano-ESI emitter tips are used for native-MS of membrane proteins solubilized in both nonionic and ionic detergent solutions. With the submicrometer nano-ESI emitter tips, resolved charge-state distributions of membrane protein ions are obtained from a 150 mM NaCl, 25 mM Tris-HCl with 1.1% octyl glucoside solution. The relative abundances of NaCl and detergent cluster ions at high m /z are significantly reduced with the submicrometer emitters compared with larger nano-ESI emitters that are commonly used. This technique is beneficial for significantly decreasing the abundances (by two to three orders of magnitude compared with the larger tip size: 1.6 μm) of detergent cluster ions formed from aqueous ammonium acetate solutions containing detergents that can overlap with the membrane protein ion signal. Resolved charge-state distributions of membrane protein ions from aqueous ammonium acetate solutions containing ionic detergents were obtained with the submicrometer nano-ESI emitters; this is the first report of native-MS of membrane proteins solubilized by ionic detergents. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CFM-ID 4.0: More Accurate ESI MS/MS Spectral Prediction and Compound Identification

In the field of metabolomics, mass spectrometry (MS) is the method most commonly used for identifying and annotating metabolites. As this typically involves matching a given MS spectrum against an experimentally acquired reference spectral library, this approach is limited by the coverage and size of such libraries (which typically number in the thousands). These experimental libraries can be greatly extended by predicting the MS spectra of known chemical structures (which number in the millions) to create computational reference spectral libraries. To facilitate the generation of predicted spectral reference libraries we developed CFM-ID, a computer program that can accurately predict ESI-MS/MS spectrum for a given compound structure. CFM-ID is one of the best-performing methods for compound-to-mass-spectrum prediction, and also one of the top tools for in silico mass-spectrum-to-compound identification. This work improves CFM-ID’s ability to predict ESI-MS/MS spectra from compounds by: (1) learning parameters from features based on the molecular topology, (2) adding a new approach to ring cleavage that models such cleavage as a sequence of simple chemical bond dissociations and (3) expanding its hand-written rule-based predictor to cover more chemical classes, including acylcarnitines, acylcholines, flavonols, flavones, flavanones, and flavonoid glycosides. We demonstrate that this new version of CFM-ID (version 4.0) is significantly more accurate than previous CFM-ID versions, in terms of both EI-MS/MS spectral prediction and compound identification. CFM-ID 4.0 is available at http://cfmid4.wishartlab.com/ as a webservice and docker images can be downloaded at https://hub.docker.com/r/wishartlab/cfmid

Wang, Fei↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

ESI-MS Identification of the Cationic Phosphine-Ligated Gold Clusters Au1-Au22: Insight into the Gold-Ligand Ratio and Abundance of Larger Clusters

Triphenylphosphine (PPh3)-ligated gold clusters offer promising potential applications due to their relative ease of synthesis and usefulness in forming advanced cluster architectures. While previous studies reported cationic PPh3-ligated gold clusters with core sizes of Au1 - Au4, Au6 - Au11, and Au¬13 - Au14, there has not been definitive identification by mass spectrometry of larger clusters in the Au12 - Au25¬ range. Herein, we survey a polydisperse solution of cationic PPh3-ligated gold clusters using high mass-resolution (M/?M = 60,000) electrospray ionization mass spectrometry (ESI-MS). To improve the sensitivity and mass resolution of larger clusters for unambiguous identification, we increased the number of scan averages and reduced the range of mass collection windows to 200 m/z, thereby mitigating potential mass and ion abundance bias resulting from smaller “building block” gold clusters and other solution components present in higher abundance. In addition to the previously reported clusters, we identified several new species including Au5(PPh3)5+, Au12(PPh3)9HCl2+, Au15(PPh3)9Cl2+, Au16(PPh3)10Cl22+, Au17(PPh3)113+, Au18(PPh3)102+, Au19(PPh3)10Cl2+, Au20(PPh3)12H33+, Au21(PPh3)10Cl2+, and Au22(PPh3)10Cl22+, indicating that a full range of clusters between Au1 - Au22 may be observed in a single polydisperse solution. Considering all of the observed clusters, our findings provide evidence that the “magic number” icosahedral Au13 may be the transition point in cluster growth between smaller clusters, exhibiting a 1:1 gold-to-ligand ratio, and larger clusters, wherein subsequent gold atoms are added to the core without an equal number of accompanying ligands. Our method demonstrates that reducing the range of m/z collection windows and increasing the number of scan averages can improve instrument sensitivity for cationic gold clusters and enable a more complete survey of polydisperse solutions, thereby providing new insights to guide and validate the results of other characterization methods and theoretical calculations. This work was supported by the US Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences. MH acknowledges support from the DOE Science Undergraduate Laboratory Internship (SULI) program. HH acknowledges support from the DOE Office of Workforce Development for Teachers and Scientist (WDTS) under the Visiting Faculty Program (VFP). This work was performed using EMSL, a national scientific user facility sponsored by the DOE's Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory (PNNL). PNNL is a multiprogram national laboratory operated for DOE by Battelle.

Hewitt, Michael↗

A Study of the γ-Radiolysis of N,N-Didodecyl-N',N'-Dioctyldiglycolamide Using UHPLC-ESI-MS Analysis

In this paper, solutions of N,N-didodecyl-N',N'-dioctyldiglycolamide in n-dodecane were subjected to γ-irradiation in the presence and absence of both an aqueous nitric acid phase and air sparging. The solutions were analyzed using ultra-high-performance liquid chromatography-electrospray ionization-mass spectrometry (UHPLC-ESI-MS) to determine the rates of radiolytic decay of the extractant as well as to identify radiolysis products. The DGA concentration decreased exponentially with increasing dose, and the measured degradation rate constants were uninfluenced by the presence or absence of acidic aqueous phase, or by air sparging. Finally, the identified radiolysis products suggest that the bonds most vulnerable to radiolytic attack are those in the diglycolamide center of these molecules and not in the side chains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ESI-FTICR-MS Molecular Characterization of DOM Degradation under Warming in Tundra Soils from Utqiagvik (Barrow), Alaska

This dataset provides the results of warming incubation of Arctic soils from trough areas of a high-center polygon at the Barrow Environmental Observatory (BEO) in northern Alaska, United States. The organic-rich soil (8-20 cm below ground surface) and the mineral-rich soil (22-45 cm below surface) were separated, and the thawed and homogenized subsamples from each soil were incubated at -2 degrees C or 8 degrees C for 122 days under anoxic conditions (headspace filled with N2). The extracted DOM from soil samples were analyzed by Fourier transform ion cyclotron resonance mass spectrometry coupled with electrospray ionization (ESI-FTICR-MS). Reported analytes include soil water content, dissolved organic carbon, total organic carbon, MS peaks' m/z and intensities, and elemental composition of identified molecular formulas. This dataset includes five csv files and one pdf file.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

ESI-FTICR-MS Analysis of Organic Matter during Incubations with Nitrogen Addition, Teller Road Site, Seward Peninsula, Alaska

This dataset contains the results of the molecular characterization of water-extractable organic matter collected during soil microcosm incubations of tundra soil. The microcosms contained soil collected in April 2017 from the NGEE Arctic Teller Road Site at mile marker 27 (TL_MM27) near Intensive Site 9 (“Toeslope”) and Intensive Site 5 (“Plateau”). The incubations were conducted under an atmosphere of N2 at 8°C for 55 days, with or without addition of ammonium chloride (NH4Cl). Soils were extracted with deionized water and extracted using Bond Elut PPL cartridges prior to analysis. Molecular characterization was performed using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI- FTICR-MS). Two data files are provided with this dataset. The first is the summary, by soil type and treatment, of the mass spectrometry results for formulas (as a % of the total) containing C, H, and O only, and with N, S, and other elements. These formulas were then grouped into nine biochemical classes of compounds based on O:C and H:C ratios. The second file provides soil sample characteristics and the processed high-resolution mass spectrometry results by soil type and treatment.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 10-year research effort (2012-2022) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. These values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction efficiency was calibrated for a given tissue type and drug, the droplet-based approach provides a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.

59 BASIC BIOLOGICAL SCIENCES↗

Gas Flow and Ion Transfer in Heated ESI Capillary Interfaces

Transfer capillaries are the preferred means to transport ions, generated by electrospray ionization, from ambient conditions to vacuum. During the transfer of ions through the narrow, long tubes into vacuum, substantial losses are typical. However, recently it was demonstrated that these losses can be avoided altogether. To understand the experimental observation and provide a general model for the ion transport, here, we investigate the ion transport through capillaries by numerical simulation of interacting ions. The simulation encompasses all relevant factors, such as space charge, diffusion, gas flow, and heating. Special attention is paid to the influence of the gas flow on the transmission and especially the change imposed by heating. The gas flow is modeled by a one-dimensional gas dynamics description. A large number of ions are treated as point particles in this gas flow. This allows to investigate the influence of the capillary heating on the gas flow and by this on the ion transport. The results are compared with experimental findings. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of tenofovir, tenofovir disoproxil fumarate and emtricitabine in aqueous solutions containing sodium ions using ESI-MS, NMR and Ab initio calculations

Here, we have discerned some characteristics of protonated and sodiated forms of emtricitabine tenofovir and tenofovir disoproxil fumarate in aqueous solutions using mass spectrometry/mass spectrometry (MS/MS), nuclear magnetic resonance spectroscopy (NMR) and Ab initio calculations. Protonated species exhibited different mass spectral characteristics from sodiated species for the three antiretroviral drugs. Sodiation of the three compounds yields extremely stable conformers which require high excitation energies to detach the sodium cation using MS/MS. In the case of emtricitabine (FTC), collision induced dissociation (CID) of the protonated species with m/z 248 yielded m/z 130 as the major product ion by losing 2-ethyl-1,3-oxathiolane. MS/MS of the sodiated molecular ion [M + Na] + with m/z 270 would be expected to yield [M + H] + i.e. m/z 248 by losing the Na + cation but instead lost 2-ethyl-1,3-oxathiolane and left the Na + cation well sequestered within the ionic complex. Similar observations were made with tenofovir disoproxil fumarate (TDF) and tenofovir (TFV). Ab initio calculations showed in the case of sodiated TDF and TFV that, the sodium could only be cleaved when a nucleophilic species i.e. PO 2 to which it was coordinated to, fragmented requiring activation energy of 1.5 eV. The potential energy barrier to remove the Na + cation alone was too high to allow the cleavage to proceed. NMR data showed that when TFV or TDF coordinates with Na + ions at one of the nitrogens at position 1 in the purine moiety of the molecule, it also interacts with oxygens of the phospho group to form an ionic complex and perturbs the chemical environments of several atoms in the periphery. The abundance of sodium cations and their strong interactions with the core structures of FTC, TDF and TFV make sodiated species as the best candidates for their quantitation using MS/MS especially in biological fluids. Evidence for improved sensitivity when sodiated species of some of the antiretroviral (ARV) drugs were used for quantitation exists in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗