Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Structural insights into VRC01-class bnAb precursors with diverse light chains elicited in the IAVI G001 human vaccine trial

The development of germline-targeting vaccines represents a potentially transformative strategy to elicit broadly neutralizing antibodies (bnAbs) against HIV and other antigenically diverse pathogens. Here, we report on structural characterization of vaccine-elicited VRC01-class bnAb precursors in the IAVI G001 Phase 1 clinical trial with the eOD-GT8 60mer nanoparticle as immunogen. High-resolution X-ray structures of eOD-GT8 monomer complexed with Fabs of five VRC01-class bnAb precursors with >90% germline identity revealed a conserved mode of binding to the HIV CD4-binding site via IGHV1-2-encoded heavy chains, mirroring mature bnAb interactions. The light-chain V-gene diversity emulated VRC01 bnAbs and stabilized antigen engagement, while their conserved five-residue LCDR3 motifs prevented steric clashes. Notably, the VRC01-class bnAb precursors accommodated the N276 glycan, a key barrier in HIV Env recognition, through structural rearrangements in HCDR3 or LCDR1, despite its absence in the immunogen. Surface plasmon resonance analysis showed that 87% of elicited antibodies retained glycan binding capacity, albeit with reduced affinity. These findings validate the ability of eOD-GT8 60mer nanoparticles to prime VRC01-class bnAb precursors with native-like paratopes but with intrinsic glycan adaptability. Structural mimicry of mature bnAbs was observed even with limited somatic hypermutation, indicating that critical features are encoded in the germline repertoire. The structures highlight how germline-encoded features drive bnAb-like recognition at early stages. This work provides molecular evidence supporting germline targeting in humans and provides guidance for designing booster immunogens to shepherd affinity maturation toward broad neutralization.

Science & Technology - Other Topics↗

Evaluating algorithmic bias on biomarker classification of breast cancer pathology reports

Objectives: This work evaluated algorithmic bias in biomarkers classification using electronic pathology reports from female breast cancer cases. Bias was assessed across 5 subgroups: cancer registry, race, Hispanic ethnicity, age at diagnosis, and socioeconomic status. Materials and Methods: We utilized 594 875 electronic pathology reports from 178 121 tumors diagnosed in Kentucky, Louisiana, New Jersey, New Mexico, Seattle, and Utah to train 2 deep-learning algorithms to classify breast cancer patients using their biomarkers test results. We used balanced error rate (BER), demographic parity (DP), equalized odds (EOD), and equal opportunity (EOP) to assess bias. Results: We found differences in predictive accuracy between registries, with the highest accuracy in the registry that contributed the most data (Seattle Registry, BER ratios for all registries >1.25). BER showed no significant algorithmic bias in extracting biomarkers (estrogen receptor, progesterone receptor, human epidermal growth factor receptor 2) for race, Hispanic ethnicity, age at diagnosis, or socioeconomic subgroups (BER ratio <1.25). DP, EOD, and EOP all showed insignificant results. Discussion: We observed significant differences in BER by registry, but no significant bias using the DP, EOD, and EOP metrics for socio-demographic or racial categories. This highlights the importance of employing a diverse set of metrics for a comprehensive evaluation of model fairness. Conclusion: A thorough evaluation of algorithmic biases that may affect equality in clinical care is a critical step before deploying algorithms in the real world. We found little evidence of algorithmic bias in our biomarker classification tool. Artificial intelligence tools to expedite information extraction from clinical records could accelerate clinical trial matching and improve care.

60 APPLIED LIFE SCIENCES↗

Anodic Hydrogen Generation from Benzaldehyde on Au, Ag, and Cu: Rotating Ring-Disk Electrode Studies

Aldehydes are selectively oxidized to carboxylates on group 11 metals at low potentials (<0.4 V vs. RHE) in alkaline media. This process can occur by a pathway that generates H 2 gas from the aldehyde, known as electro-oxidative dehydrogenation (EOD) or anodic hydrogen production. The EOD process occurs with transfer of only one electron per aldehyde, whereas typical oxidation with discharge of hydrogen to form water is a two-electron process. Here, we study the catalytic activity and selectivity toward H 2 of Au, Ag, and Cu electrodes using benzaldehyde with rotating disk and ring-disk electrode (RDE/RRDE) techniques. The average number of electrons per benzaldehyde molecule obtained via H 2 detection by RRDE agrees with that obtained via Koutecký-Levich analysis conducted at various rotation rates. We find that Au and Ag have much higher H 2 and benzoate formation rates than Cu, but that Cu can perform the reaction at about 0.2 V lower overpotentials. On all three materials, benzaldehyde oxidation has high selectivity to anodic H 2 (one-electron pathway) below ∼0.5 V vs. RHE, but, with increasing potential, the selectivity shifts to H-oxidation forming water (two-electron pathway).

Ramos, Nathanael C. (ORCID:0000000247210350)↗

Stingray Case Study

Improvised explosive devices (IEDs) have injured and killed numerous soldiers and civilians as a consequence of military operations in the Middle East. With gaps in existing technologies, the US military required devices for quickly addressing deadly IEDs without harming military personnel or inflicting severe damage to the environment. In response to this need, Sandia developed Stingray, a clear, plastic handheld device to quickly and safely disable threatening IEDs. Stingray is designed to be used in two configurations: a coherent water blade for cutting operations and as a water slug for general device disruption. Prior to disabling an IED, Explosive Ordnance Disposal (EOD) technicians will x-ray the target using tools such as Sandia's X-ray Toolkit (XTK) to determine which function operators should use to dismantle the IED. For example, if the operator knows exactly which wires to cut, they can use the precision water blade. If the operator wants to create a general disruption, they can use the water slug function.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗