Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The CeBrA demonstrator for particle-γ coincidence experiments at the FSU Super-Enge Split-Pole Spectrograph

We report on a highly selective experimental setup for particle-γ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr scintillators for γ-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr 3 scintillation detectors of the CeBr 3 Array (CeBrA) with respect to energy resolution and timing characteristics. We also present results from the first particle-γ coincidence experiments successfully performed with the CeBrA demonstrator and the FSU SE-SPS. We show that with the new setup, γ-decay branching ratios and particle-γ angular correlations can be measured very selectively using narrow excitation energy gates, which are possible thanks to the excellent particle energy resolution of the SE-SPS. In addition, we highlight that nuclear level lifetimes in the nanoseconds regime can be determined by measuring the time difference between particle detection with the SE-SPS focal-plane scintillator and γ-ray detection with the fast CeBrA detectors. As a result, selective excitation energy gates with the SE-SPS exclude any feeding contributions to these lifetimes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Negative Mass Instability in an Enge "Pretzel" Magnet

A novel magnet invented by Harald Enge has the useful property of achromatically deflecting charged particle beams. One can envision many applications for these for transport and guiding in high-current electron beam research. However, a high-current electron beam bent by the magnetic field in one of these magnets is subject to the negative mass instability. The negative mass instability is a problem for all accelerators that rely on magnetic fields to bend or circulate the beam. The subject of this article is the assessment of this instability in these devices for a range of electron beam parameters typical of the linear induction accelerators (LIAs) at Los Alamos. We first describe the properties of the magnet, and then calculate the negative mass instability growth rate for a high current beam having parameters of interest. Finally, we show that the beam does not spend enough time circulating through the magnet for the instability to grow significantly.

43 PARTICLE ACCELERATORS↗

Corrigendum to “The effects of nearby fractures on hydraulically induced fracture propagation and permeability changes” [Eng. Geol. 228 (2017) 197–213]

The authors regret the error regarding the grant number in the acknowledgements in the paper already published. The grant number concerning EU project is 636811 instead of 640979. There was a misunderstanding with the EU project number and we only found that after those papers are published. The corrected text should be: “The authors gratefully acknowledge the Swedish Geological Survey (SGU), grant number 1724, and the EU project Fracrisk grant number 636811, for providing financial support to research reported in this paper. Additional support was provided by the U.S. Department of Energy under contract No. DE-AC02-05CH11231.” The authors would like to apologise for any inconvenience caused.

99 GENERAL AND MISCELLANEOUS↗

Corrigendum to “Engineering Pseudomonas putida KT2440 for efficient ethylene glycol utilization” [Metab. Eng. 48 (2018) 197–207]

The sequence of the promoter used to drive expression of glcDEF operon in the engineered strain MFL185 in the original article was incorrect. As described here, we performed additional experiments that indicate expression of this operon was increased in MFL185, as intended. Ultimately, this error is immaterial with respect to the findings and conclusions reported in the original article.

59 BASIC BIOLOGICAL SCIENCES↗

Corrigendum to "Engineering glucose metabolism for enhanced muconic acid production in Pseudomonas putida KT2440" [Metab. Eng. 59 (2020) 64-75]

The plasmid used to delete hexR, pGB022, in our Pseudomonas putida KT2440 strain engineered to produce cis,cis-muconic acid from glucose, GB062, inadvertently introduced two mutations: a point mutation in the zwf-1, encoding the glucose-6-phosphate 1-dehydrogenase, that results in a conservative, V157I replacement and a deletion of the last 8 bp of the glucose-6-phosphate 1-epimerase gene, yeaD, leading to a frame shift in this gene and, consequently, the replacement of the last two amino acids of the C-terminus (LS) with 56 amino acids (RGPWVCPWVGKTAGCVSSRLFARSSIVLSVRLTYHLSVTLVCNVVVFTTLSLENRV).

BIOMASS FUELS↗

ENG 572 Final Report

Thermo-electric coolers (TECs) provide an essential function in many high-powered applications by diverting heat away from a temperature-sensitive load. This summer I have worked with Sandia National Laboratories in exploring the failure mechanisms behind said devices. I have been tasked with determining a plan of action for two TECs manufactured by two different companies labeled A and B respectively. Prior to my involvement in the project, the former has displayed failures during normal operation within its packaging. The latter was subsequently chosen to resolve these issues. Thermal cycling between the extreme expected operating temperatures (-40°C to 80°C) was applied to 5 unmounted TECAs over a period of 5 hours with 1-hour soaks at each extreme. The unmounted TECBs are currently undergoing the same process, and the task is expected to be completed over the next few weeks. The results of the TECA characterization have indicated no failure has occurred, which indicates that failure will need to be induced through either higher temperature extremes or additional mechanical stress.

47 OTHER INSTRUMENTATION↗

ENG 572 Interim Report

Sandia National Laboratories is a Federally Funded Research and Development Center (FFRDC) founded in 1949 with the mission of developing and testing the non-nuclear components of nuclear weapons. Sandia has since been involved with numerous projects to support the Department of Defense’s (DOE) National Nuclear Security Administration (NNSA). One such set of projects has been implementing over-the-road transportation security enhancements. Under this program, Sandia National Laboratories (SNL) has worked to develop interface compatibility modifications for existing shipping configurations. This summer I will be working with a line of trailers that have been used to transport high asset cargo. These vehicles have successfully traveled millions of miles without any accidents over the course of 15 years. The primary motivation for the work that I will complete this summer is to provide support for existing electronic communication technologies implemented at SNL. As part of an ongoing project to implement modifications to a trailer system, I will focus primarily on the characterization and testing of thermal electric coolers (TEC). Within the scope of the trailer project, these devices provide temperature control for lasers used on optical communication boards (OCB).

42 ENGINEERING↗

LAMP Emittance Budget LAMP-ENG-RPT-002

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP).

43 PARTICLE ACCELERATORS↗

LAMP Technical Readiness Evaluation Report: LAMP-ENG-RPT-003 (Revision 2)

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risks to the project. These recent design modifications are based on the LAMP Conceptual Design which is the design evaluated in this document and include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (i.e. choppers, kickers, and bunchers). • An additional 100-keV H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H - ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional 3-MeV Radio Frequency Quadrupole (RFQ) design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project Key Performance Parameters (KPPs). • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages.

43 PARTICLE ACCELERATORS↗

Review of MSFC SBIR's: Xinetics RB-SiC Mirror Fabrication Study, UltraMet PG Foam Mirror Fabrication Study, Blue Line Eng. AI Enhanced Edge Sensors and Fully Active Subscale Telescope

This presentation will briefly review the objectives and anticipated benefits of several Small Business Innovative Research projects in progress under the direction of Marshall Space Flight Center. They all relate to the development of advanced optical systems technologies important to future astronomical missions in space.

Montgomery, Edward E., IV↗