Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessing overall building energy performance of a large population of residential single-family homes using limited field data

The U.S. Department of Energy (DOE), through the Building Energy Codes Program (BECP), supports building energy code development and implementation processes to achieve the maximum practicable, cost-effective improvements in energy efficiency while providing safe, healthy buildings for occupants. Currently, there is a lack of statistically representative data that shows how energy codes are implemented in the field and the energy savings opportunities that exist. To address this gap, DOE initiated a research study targeted at new residential single-family homes in 8 states starting in the fall of 2014. The study comprises of a baseline phase to determine current levels of compliance with the key energy provisions of the residential building energy code, identify issues, and calculate potential energy savings from improved compliance; a second phase implementing education, training and outreach activities designed to increase targeted code compliance; and a post-study phase to measure the impact of the training and outreach activities compared to the baseline phase. Initial analyses determined the code requirements with the largest energy impact and the minimum number of observations required to detect statistically significant differences in energy use. Data was collected in the field during a single site visit to avoid bias from repeat visits. However, the single site visit principle prevented energy simulation of individual homes due to the lack of all required model inputs. To address this, energy simulation was conducted using Pacific Northwest National Laboratory’s prototype building models and employing bootstrap random sampling on the data collected from all homes visited. The modeled energy consumption using the observed field data was evaluated relative to that associated with the minimum code requirements and potential savings associated with improved compliance of select items were assessed. This paper discusses the methodology developed for this field study, and presents the results and findings from the baseline phase.

Xie, YuLong↗

Linkages between Policy and Business Innovation in the Development of China’s Energy Performance Contracting Market

China has a large and growing energy performance contracting (EPC) market, which has played a significant role in driving energy efficiency retrofits and improvements This paper evaluates how policies and business innovations have worked synergistically to expand China’s EPC market. We analyze the interconnected roles of four key factors: incentive policies, China’s Five-Year Plans, and business innovations in diversifying contract models and strengthening measurement and verification. We use multiple data sources for the analysis, including detailed information on business choices in 21 pilot projects, industry-wide surveys, and policy information. Our study indicates that supportive policies were important for the initial market development. As the market was established and continued to grow, the private sector started to take initiatives to address the issues that are left out of the policies, which helped overcome certain market barriers and enabled the sustainable growth of the market. Future policies could incorporate the successful innovations from the businesses to ensure long-term development of China’s EPC market. Understanding these policy and business drivers in a holistic way is critical to understanding how China was able to leverage its relatively small policy investments into much larger transformation of its existing buildings and industrial facilities through energy efficiency retrofits. This in turn can be informative for other countries seeking to achieve large-scale energy efficiency improvements.

Zhou, Yuanrong↗

A SOFTWARE TOOL TO COMPARE MEASURED AND SIMULATED BUILDING ENERGY PERFORMANCE DATA

Building energy performance is often inadequate when compared to design goals. To link design goals to actual operation one can compare measured with simulated energy performance data. Our previously developed comparison approach is the Energy Performance Comparison Methodology (EPCM), which enables the identification of performance problems based on a comparison of measured and simulated performance data. In context of this method, we developed a software tool that provides graphing and data processing capabilities of the two performance data sets. The software tool called SEE IT (Stanford Energy Efficiency Information Tool) eliminates the need for manual generation of data plots and data reformatting. SEE IT makes the generation of time series, scatter and carpet plots independent of the source of data (measured or simulated) and provides a valuable tool for comparing measurements with simulation results. SEE IT also allows assigning data points on a predefined building object hierarchy and supports different versions of simulated performance data. This paper briefly introduces the EPCM, describes the SEE IT tool and illustrates its use in the context of a building case study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Two High-Performance Energy Efficient Homes: Annual Performance Report, December 1, 2010–November 30, 2011

Beginning in 2008, two pairs of energy-saver houses were built at Wolf Creek in Oak Ridge, TN. These houses were designed to maximize energy efficiency using new ultra-high-efficiency components emerging from ORNL s Cooperative Research and Development Agreement (CRADA) partners and others. The first two houses contained 3713 square feet of conditioned area and were designated as WC1 and WC2; the second pair consisted of 2721 square feet conditioned area with crawlspace foundation and they re called WC3 and WC4. This report is focused on the annual energy performance of WC3 and WC4, and how they compare against a previously benchmarked maximum energy efficient house of a similar footprint. WC3 and WC4 are both about 55-60% more efficient than traditional new construction. Each house showcases a different envelope system: WC3 is built with advanced framing featured cellulose insulation partially mixed with phase change materials (PCM); and WC4 house has cladding composed of an exterior insulation and finish system (EIFS). The previously benchmarked house was one of three built at the Campbell Creek subdivision in Knoxville, TN. This house (CC3) was designed as a transformation of a builder house (CC1) with the most advanced energy-efficiency features, including solar electricity and hot water, which market conditions are likely to permit within the 2012 2015 period. The builder house itself was representative of a standard, IECC 2006 code-certified, all-electric house built by the builder to sell around 2005 2008.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stable Low-Current Electrodeposition of α-MnO 2 on Superaligned Electrospun Carbon Nanofibers for High-Performance Energy Storage

Metal oxide/carbonaceous nanomaterials are promising candidates for energy-storage applications. Yet, inhomogeneous mass and charge transfer across the electrode/electrolyte interface due to unstable metal oxide/carbonaceous nanomaterial synthesis limit their performance in supercapacitors. Here, it is shown that the above problems can be mitigated through stable low-current electrodeposition of MnO 2 on superaligned electrospun carbon nanofibers (ECNFs). The key to this method is coupling a self-designed four steel poles collector for aligned ECNFs and a constant lowcurrent (40 μA) electrodeposition technique to form a uniform Na + -induced α-MnO 2 film which proceeds by a time-dependent growth mechanism involving cluster-“kebab” structures and ending with a compact, uniform MnO 2 film for high-performance energy storage.

36 MATERIALS SCIENCE↗

Improving Access to Foundational Energy Performance Data

Access to foundational energy performance data is key to improving the efficiency of the built environment. However, stakeholders often lack access to what they perceive as credible energy performance data. Therefore, even if a stakeholder determines that a product would increase efficiency, they often have difficulty convincing their management to move forward. Even when credible data do exist, such data are not always sufficient to support detailed energy performance analyses, or the development of robust business cases. One reason for this is that the data parameters that are provided are generally based on the respective industry norms. Thus, for mature industries with extensive testing standards, the data made available are often quite detailed. But for emerging technologies, or for industries with less well-developed testing standards, available data are generally insufficient to support robust analysis. However, even for mature technologies, there is no guarantee that the data being supplied are the same data needed to accurately evaluate a product?s energy performance. To address these challenges, the U.S. Department of Energy funded development of a free, publically accessible Web-based portal, the Technology Performance Exchange(TM), to facilitate the transparent identification, storage, and sharing of foundational energy performance data. The Technology Performance Exchange identifies the intrinsic, technology-specific parameters necessary for a user to perform a credible energy analysis and includes a robust database to store these data. End users can leverage stored data to evaluate the site-specific performance of various technologies, support financial analyses with greater confidence, and make better informed procurement decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

Assessing the Costs and Benefits of the Superior Energy Performance Program

Industrial companies are seeking to manage energy consumption and costs, mitigate risks associated with energy, and introduce transparency into reports of their energy performance achievements. Forty industrial facilities are participating in the U.S. DOE supported Superior Energy Performance (SEP) program in which facilities implement an energy management system based on the ISO 50001 standard, and pursue third-party verification of their energy performance improvements. SEP certification provides industrial facilities recognition for implementing a consistent, rigorous, internationally recognized business process for continually improving energy performance and achievement of established energy performance improvement targets. This paper focuses on the business value of SEP and ISO 50001, providing an assessment of the costs and benefits associated with SEP implementation at nine SEP-certified facilities across a variety of industrial sectors. These cost-benefit analyses are part of the U.S. DOE?s contribution to the Global Superior Energy Performance (GSEP) partnership, a multi-country effort to demonstrate, using facility data, that energy management system implementation enables companies to improve their energy performance with a greater return on investment than business-as-usual (BAU) activity. To examine the business value of SEP certification, interviews were conducted with SEP-certified facilities. The costs of implementing the SEP program, including internal facility staff time, are described and a marginal payback of SEP certification has been determined. Additionally, more qualitative factors with regard to the business value and challenges related to SEP and ISO 50001 implementation are summarized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of an Enhanced Payback Function for the Superior Energy Performance Program

The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This paper analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.

Therkelsen, Peter↗

IFC BIM-Based Methodology for Semi-Automated Building Energy Performance Simulation

Building energy performance (BEP) simulation is still rarely used in building design, commissioning and operations. The process is too costly and too labor intensive, and it takes too long to deliver results. Its quantitative results are not reproducible due to arbitrary decisions and assumptions made in simulation model definition, and can be trusted only under special circumstances. A methodology to semi-automate BEP simulation preparation and execution makes this process much more effective. It incorporates principles of information science and aims to eliminate inappropriate human intervention that results in subjective and arbitrary decisions. This is achieved by automating every part of the BEP modeling and simulation process that can be automated, by relying on data from original sources, and by making any necessary data transformation rule-based and automated. This paper describes the new methodology and its relationship to IFC-based BIM and software interoperability. It identifies five steps that are critical to its implementation, and shows what part of the methodology can be applied today. The paper concludes with a discussion of application to simulation with EnergyPlus, and describes data transformation rules embedded in the new Geometry Simplification Tool (GST).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Methodology for Calculating The Energy Performance of Manufacturing Facilities

Total energy comparison (TEC), classic energy intensity (CEI), and linear regression models (LRM) are the three most common approaches used to track the energy performance of manufacturing facilities. TEC simply compares the total energy consumption from utility bills. TEC is rarely used because it does not consider the variation of any factors that may affect energy consumption. One step better, CEI considers the variation of production rates by using the ratio of annual total energy consumption over annual total production. However, CEI fundamentally assumes that energy consumption is zero if the production rate is zero. This is almost never true and can cause significant errors. Using linear regression models, LRM considers the impact of multiple variables and, therefore, most accurately tracks energy performance. Unfortunately, because of the lack of either required data or technical expertise, some facilities cannot create valid linear regression models. For these cases, CEI is the only option. Here, the goal of this article is to develop a new methodology, modified energy intensity (MEI), which is more accurate than CEI, but requires much less data and is easier to implement than LRM. Using the underlying principle of LRM, this article first outlines the mathematical derivation of the equations for MEI, then explains them from an engineering perspective. Finally, the implementation of MEI is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MEPHESTO: Modeling Energy-Performance in Heterogeneous SoCs and Their Trade-Offs

Integrated shared memory heterogeneous architectures are pervasive because they satisfy the diverse needs of mobile, autonomous, and edge computing platforms. Although specialized processing units (PUs) that share a unified system memory improve performance and energy efficiency by reducing data movement, they also increase contention for this memory since the PUs interact with each other. Prior work has investigated performance degradation due to memory contention, but few have studied the relationship of power and energy to memory contention. Moreover, a comprehensive solution that models memory contention for kernel placement on contemporary heterogeneous systems on chip (SoCs) in response to energy and performance has been largely unaddressed.This paper presents MEPHESTO, a novel and holistic approach for managing this balance. The authors characterize applications and PUs in terms of two memory contention factors - time factors and power factors - to achieve the desired trade-off between energy and performance for collocated kernel execution on heterogeneous systems. The authors believe that this investigation is the first to combine all of these factors and present a simple knob-based approach that expresses the target trade-off. The approach is evaluated on a diverse integrated shared memory heterogeneous system with a CPU, GPU, and programmable vision accelerator. By using an empirical model for memory contention that provides up to 92% accuracy, the kernel collocation approach can provide a near-optimal ordering and placement based on the user-defined, energy-performance trade-off parameter. Moreover, the dynamic programming-based heuristics provide up to 30% better energy or 20% performance benefits when compared with the greedy approaches commonly employed by previous studies.

Alaul haque monil, Mohammad↗

Radiative energy receiver for high performance energy conversion cycles

An analysis of gas dynamic processes pertinent to the functioning of earth-based and space-based solar electric power plants is presented, with attention given to potassium vapor as the working fluid. A device is described which features focused photon absorption by a nontransparent flowing gas. The feed flow is effected around the outside walls of a cavity receiver to raise efficiencies by trapping reemitted energy. A theoretical study of the interaction of a photon flux with a coaxial particle flux was performed, with the receiver flow treated as a Graetz flow. The critical parameters were defined, including a figure of merit as the gas enthalpy increase to absorbable energy ratio. A small-scale laboratory model was tested in comparison with the theoretically obtained values. Less than 15% of the absorbed energy was lost through dissipation while an 80% conversion efficiency was attained.

Rault, D.↗