Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EMIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Counting Particles Emitted by Stratospheric Aircraft and Measuring Size of Particles Emitted by Stratospheric Aircraft

There were two principal objectives of the cooperative agreement between NASA and the University of Denver. The first goal was to modify the design of the ER-2 condensation nuclei counter (CNC) so that the effective lower detection limit would be improved at high altitudes. This improvement was sought because, in the instrument used prior to 1993, diffusion losses prevented the smallest detectable particles from reaching the detection volume of the instrument during operation at low pressure. Therefore, in spite of the sensor's ability to detect particles as small as 0.008 microns in diameter, many of these particles were lost in transport to the sensing region and were not counted. Most of the particles emitted by aircraft are smaller than 0.1 micron in diameter. At the start date of this work, May 1990, continuous sizing techniques available on the ER-2 were only capable of detecting particles larger than 0.17 micron. Thus, the second objective of this work was to evaluate candidate sizing techniques in an effort to gain additional information concerning the size of particles emitted by aircraft.

Wilson, James Charles↗

Counting particles emitted by stratospheric aircraft and measuring size of particles emitted by stratospheric aircraft

The ER-2 condensation nuclei counter (CNC) has been modified to reduce the diffusive losses of particles within the instrument. These changes have been successful in improving the counting efficiency of small particles at low pressures. Two techniques for measuring the size distributions of particles with diameters less than 0.17 micrometers have been evaluated. Both of these methods, the differential mobility analyzer (DMA) and the diffusion battery, have fundamental problems that limit their usefulness for stratospheric applications. We cannot recommend either for this application. Newly developed, alternative methods for measuring small particles include inertial separation with a low-loss critical orifice and thin-plate impactor device. This technique is now used to collect particles in the multisample aerosol collector housed in the ER-2 CNC-2, and shows some promise for particle size measurements when coupled with a CNC as a counting device. The modified focused-cavity aerosol spectrometer (FCAS) can determine the size distribution of particles with ambient diameters as small as about 0.07 micrometers. Data from this instrument indicates the presence of a nuclei mode when CNC-2 indicates high concentrations of particles, but cannot resolve important parameters of the distribution.

Wilson, James Charles↗

Emitted Power Of Jupiter Based On Cassini CIRS And VIMS Observations

The emitted power of Jupiter and its meridional distribution are determined from observations by the Composite Infrared Spectrometer (CIRS) and Visual and Infrared Spectrometer (VIMS) onboard Cassini during its flyby en route to Saturn in late 2000 and early 2001. Jupiter's global- average emitted power and effective temperature are measured to be 14.10+/-0.03 W/sq m and 125.57+/-0.07 K, respectively. On a global scale, Jupiter's 5-micron thermal emission contributes approx. 0.7+/-0.1 % to the total emitted power at the global scale, but it can reach approx. 1.9+/-0.6% at 15degN. The meridional distribution of emitted power shows a significant asymmetry between the two hemispheres with the emitted power in the northern hemisphere 3.0+/-0.3% larger than that in the southern hemisphere. Such an asymmetry shown in the Cassini epoch (2000-01) is not present during the Voyager epoch (1979). In addition, the global-average emitted power increased approx. 3.8+/-1.0% between the two epochs. The temporal variation of Jupiter's total emitted power is mainly due to the warming of atmospheric layers around the pressure level of 200 mbar. The temporal variation of emitted power was also discovered on Saturn (Li et al., 2010). Therefore, we suggest that the varying emitted power is a common phenomenon on the giant planets.

Li, Liming↗

Efficiency cliff in scaling InGaN light-emitting diodes down to submicron

The top-down submicron fabrication of blue-emitting light-emitting diodes on Qromis Substrate Technology substrates is reported. Light-emitting diodes with mesa sizes as small as 250 × 250 nm 2 show ideal forward voltage and low leakage current density. It is observed that sidewall treatment and passivation methods used in micro-light-emitting diodes (2–20 μ m) do not lead to the same level of sidewall recombination suppression for submicron ones (< 1 μ m), as evidenced by a ∼70% decrease in peak external quantum efficiencies when mesa sizes are scaled from 2 μ m down to 250 nm. This is attributed to the lateral carrier diffusion being comparable to the mesa size, regardless of the sidewall passivation and recovery. The results call for rethinking the impact of sidewalls in emerging top-down fabricated (sub)micrometer-light-emitting diodes.

42 ENGINEERING↗

Halide perovskite-polymer composite film for bright and stable light-emitting devices

Stability is the primary hindrance for the application of halide perovskite material in light-emitting devices, solar cells, and other devices. In this work, halide perovskite and polymer composite film have been prepared for stable and bright light-emitting devices. Pure-phase Cs4PbBr6 crystals have been synthesized, and their photoluminescence (PL) properties and fluorescence lifetimes have been investigated. The Cs 4 PbBr 6 crystals exhibited high uniformity but underwent rapid photodegradation under light irradiation. To address this issue, we prepared bright light-emitting devices using composite of Cs 4 PbBr 6 crystals and polyethylene oxide (PEO) as the emission layer. The aim was to improve the optical and physical properties of halide perovskites, such as photodegradation and stability. PEO, with its excellent film-forming ability, created a uniform and dense film on the halide perovskite surface, filling microscopic defects and providing a protective barrier. FTIR, morphology, and PL analyses confirmed the protective role of the halide perovskite and polymer composite film. The composite film light-emitting devices demonstrated improved stability and higher PL brightness, with a peak brightness approaching 3 × 10 8 cd/m 2 , which was approximately 75% higher than the pure halide perovskite devices.

Composite film↗

Analysis of simulated measurements of earth emitted radiation using geometric shape factors, and some results from analysis of ESSA 7 and Nimbus 6 data

In the reported study, simulated measurements of earth radiation with wide field-of-view (WFOV) radiometers are reduced to earth fluxes through geometric shape factors. Estimates of emitted flux for global and zonal scales and for regions smaller than the detector field-of-view are compared to fluxes derived directly from a model. Geometric shape factors are used to estimate global, zonal, and regional averages of earth-emitted flux from measurements with WFOV detectors on the ESSA 7 satellite and the Nimbus 6 satellite. Zonal and global averages of emitted flux for each of the 3-month periods of ESSA 7 data are shown in a graph. Another graph shows zonal and global averages of emitted flux for August 1975 obtained with the aid of Nimbus 6. The data are compared to values reported by Green and Smith (1977) who used a spherical harmonic solution.

Weaver, W. L.↗

A comparison between satellite-defined and parameterized land-water differences in emitted longwave radiation

An analysis is performed to qualitatively compare the seasonal variation in emitted longwave radiation over land and over water areas as determined from 12 months of Nimbus 6 satellite data with that defined from parameterizations of this radiation budget component. These variations are noted when land and water surface areas are mapped to corresponding areas at the 'top' of the atmosphere. Variations of a surface-temperature-dependent parameterization of emitted longwave radiation originally suggested by Budyko (1969) are considered. The longwave radiation parameterizations indicate small differences between land and water profiles of emitted longwave radiation at the top of an atmospheric column in low latitudes in comparison to large differences in this feature shown to exist in the satellite data. The small differences are noted in linear parameterizations of emitted flux when zonally-averaged satellite data are used to define equation coefficients.

Stephenson-Graves, D.↗

Size of a gamma-ray burster optical emitting region

Measured limits on the quiescent optical and IR flux of the Nov. 19, 1978 gamma ray burster event are presented and used to establish a lower limit to the size of the optically emitting region. A total of 305 min of exposure was made, using a CCD with a UV cutoff at 3800 A. It was determined that the size of the optical emitting region is more than an order of magnitude larger than a neutron star. The size of the optical emitting region did not, however, coincide with that of the gamma ray emitting region, indicating that the optical emissions originate from a different area of the region, i.e., from a companion star or accretion disk rather than a neutron star.

Schaefer, B. E.↗

Techniques for using emitting probes for potential measurement in RF plasmas

Investigations of the effects of RF on plasma potential measurements with electron emitting probes and methods for interpreting data are presented. Techniques correspond to the floating and inflection point methods of single-emitting and differential emitting probes, respectively. A simple method of measurement of plasma potential fluctuations is given which makes use of time-averaged emitting probe I-V characteristics.

Wang, E. Y.↗

AlxGa1-xAs Single-Quantum-Well Surface-Emitting Lasers

Surface-emitting solid-state laser contains edge-emitting Al0.08Ga0.92As single-quantum-well (SQW) active layer sandwiched between graded-index-of-refraction separate-confinement-heterostructure (GRINSCH) layers of AlxGa1-xAs, includes etched 90 degree mirrors and 45 degree facets to direct edge-emitted beam perpendicular to top surface. Laser resembles those described in "Pseudomorphic-InxGa1-xAs Surface-Emitting Lasers" (NPO-18243). Suitable for incorporation into optoelectronic integrated circuits for photonic computing; e.g., optoelectronic neural networks.

Kim, Jae H.↗

Location of the emitting regions in the mode-switching radio pulsar PSR 1926 + 18

We present an analysis of average single-frequency profiles of the radio pulsar PSR 1926 + 18 in two different modes. Assuming a purely dipolar field and taking into account retardation, aberration, magnetic line curvature, and ignoring the magnetic field line sweepback, we come to the following conclusions: (1) mode switching in PSR 1926 + 18 at 430 MHz may be understood in terms of different emission heights of the two modes; (2) the weaker mode appears when regions emitting the first two components move away from the star by an additional distance of not more than several kilometers from their original locations; (3) the trailing conal component is emitted essentially from the same layer of the magnetosphere in both modes, in contrast to the first conal component, which appears to change its location in the magnetosphere; (4) core and conal components are emitted from distinctly different emission heights: core components not more than 75 km, and conal components not less than 215 km from the surface of the star. Our model infers three-dimensional information about the emitting region from single-frequency observations. It has been tested previously with a mode switching pulsar that had one component in the average profile in two modes. This paper shows that the same model can explain positions and widths of the components in a more complex profile during mode switching, provided that the components can be traced from one mode to another.

Nowakowski, L. A.↗

Reshaping Light-Emitting Diodes To Increase External Efficiency

Light-emitting diodes (LEDs) reshaped, according to proposal, increasing amount of light emitted by decreasing fraction of light trapped via total internal reflection. Results in greater luminous output power for same electrical input power; greater external efficiency. Furthermore, light emitted by reshaped LEDs more nearly collimated (less diffuse). Concept potentially advantageous for conventional red-emitting LEDs. More advantageous for new "blue" LEDs, because luminous outputs and efficiencies of these devices very low. Another advantage, proposed conical shapes achieved relatively easily by chemical etching of semiconductor surfaces.

Rogowski, Robert↗

Refraction of Sound Emitted Near Solid Boundaries from a Sheared Jet

A mathematical model is developed to describe the sound emitted from an arbitrary point within a turbulent flow near solid boundaries. A unidirectional, transversely sheared mean flow is assumed, and the cross-section of the cold jet is of arbitrary shape. The analysis begins with Lilley's formulation of aerodynamic noise and, depending upon the specific model of turbulence used, leads via Fourier analysis to an expression for the spectral density of the intensity of the far-field sound emitted from a unit volume of turbulence. The expressions require solution of a reduced Green's function of Lilley's equation as well as certain moving axis velocity correlations of the turbulence. Integration over the entire flow field is required in order to predict the sound emitted by the complete flow. Calculations are presented for sound emitted from a plugflow jet exiting a semi-infinite flat duct. Polar plots of the far-field directivity show the dependence upon frequency and source position within the duct. Certain model problems are suggested to investigate the effect of duct termination, duct geometry, and mean flow shear upon the far-field sound.

Dill, Loren H.↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Optical Design of the Earth Surface Mineral Dust Source Investigation (EMIT) Imaging Spectrometer

The Earth Surface Mineral Dust Source Investigation (EMIT) instrument is a high fidelity imaging spectrometer developed to characterize surface mineralogy of the Earth’s dust source regions over the spectral range of 380- 2500 nm and spectral sampling of 7.4 nm. EMIT will close the current knowledge gap in dust source mineral composition by collecting over 1 billion high signal-to-noise ratio spectra in this region of our planet. These new measurements will be used in conjunction with state-of-the-art Earth System Models to understand and reduce the uncertainty in the radiative forcing effect of mineral dust aerosols. EMIT will be deployed on the International Space Station that has an orbit that is well suited for measuring the arid land regions of the Earth. The optical design utilizes a Dyson spectrometer to reduce volume and mass for a fast (F/1.8) and wide swath (1240 samples) optical system. An overview of the EMIT optical design, development, and current status are discussed.

Green, Robert O.↗

Using Polarized PCRTM-Solar Model to Validate EMIT Surface Reflectance L2A Product

Using the vector linearized discrete ordinate radiative transfer model (VLIDORT), a multiple-scattering multi-layer scattering code, coupled with a fast principal component (PC) radiative transfer model (PCRTM), we can simulate hyperspectral radiation fields from visible to shortwave infrared (VSWIR), i.e., 250 nm to 2500 nm. Since only limited accurate line-by-line calculation using VLIDORT is needed, this coupled PCRTM-VLIDORT approach is very efficient for simulating hyperspectral VSWIR spectra. These simulations incorporate accurately defined optical properties (gas absorptions, molecular and aerosol/cloud particle scattering) and detailed surface reflectance inputs. In this study we used the current L2A products of the Earth Surface Mineral Dust Source Investigation (EMIT) imaging spectrometer as the inputs to PCRTM-VLIDORT to simulate EMIT spectra. Comparing the simulated spectra with EMIT measurements provides an efficient method to validate the current EMIT product.

Xiaozhen Xiong↗