Model simulations of continuous ion injection into electron-beam ion source trap with slanted electrostatic mirror

The efficiency of trapping ions in an electron-beam ion source (EBIS) is of primary importance for many applications requiring operations with externally produced ions: RIA breeders, ion sources, and traps. At the present time, the most popular method of ion injection is pulsed injection, when short bunches of ions get trapped in a longitudinal trap while traversing the trap region. Continuous trapping is a challenge for EBIS devices because mechanisms which reduce the longitudinal ion energy per charge in a trap (cooling with residual gas, energy exchange with other ions, and ionization) are not very effective, and accumulation of ions is slow. A possible approach to increase trapping efficiency is to slant the mirror at the end of the trap which is opposite to the injection end. A slanted mirror will convert longitudinal motion of ions into transverse motion, and, by reducing their longitudinal velocity, prevent these ions from escaping the trap on their way out. The trade-off for the increased trapping efficiency this way is an increase in the initial transverse energy of the accumulated ions. The slanted mirror can be realized if the ends of two adjacent electrodes, drift tubes, which act as an electrostatic mirror, are machined to produce a slanted gap, rather than an upright one. Applying different voltages to these electrodes will produce a slanted mirror. The results of two-dimensional (2D) and three-dimensional (3D) computer simulations of the ion injection into an EBIS are presented using simplified models of an EBIS with conical (2D simulations) and slanted (3D simulations) mirror electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization of polarized {sup 3}He{sup +} ions in EBIS trap with slanted electrostatic mirror

Methods of producing the nuclear polarized {sup 3}He{sup +} ions and their ionization to {sup 3}He{sup ++} in ion trap of the electron Beam Ion Source (EBIS) are discussed. Computer simulations show that injection and accumulation of {sup 3}He{sup +} ions in the EBIS trap with slanted electrostatic mirror can be very effective for injection times longer than the ion traversal time through the trap.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive quantum measurement for low-dose electron microscopy

The resolution of current cryoelectron microscopy of radiation-sensitive specimens is ultimately limited by statistical noise because of the necessarily small number of electrons. To bypass this resolution barrier, we propose an extended in-focus phase-contrast microscopy scheme. The scheme incorporates a pixelwise deformable electrostatic mirror at a plane conjugate to the back focal plane of the objective lens. This setup would extract structural information more efficiently than otherwise and naturally enable generation of phase contrast. We present key concepts regarding microscope operations and estimate the degree of electron dose reduction that should in turn enable a resolution improvement.

74 ATOMIC AND MOLECULAR PHYSICS↗

An improved time-of-flight method for cluster deposition and ion-scattering experiments

A molecular beam apparatus has been developed for deposition and scattering experiments of size-selected clusters. The new setup combines a bimetallic laser ablation cluster source with a collinear time-of-flight mass spectrometer. Mass selection is achieved with a pulsed electrostatic mirror. A significantly improved transmission in combination with a reduction of the kinetic energy distribution of the mass selected clusters has been obtained. Without further modification of the apparatus, surface-induced dissociation of mass selected tin clusters has been investigated, demonstrating the possibility to combine cluster beam deposition and scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 'tabletop' electrostatic ion storage ring: Mini-Ring

We report on the design, construction, and commissioning of a novel electrostatic ion storage ring of small dimensions - in the following referred to as 'Mini-Ring'. Mini-Ring consists of four horizontal parallel-plate deflectors and two conical electrostatic mirrors. Ions are injected through the two deflectors on the injection side and off axis with respect to the conical mirrors which face each other. The first injection deflector, originally at zero voltage, is switched to its set value such that the ions after one turn follow stable trajectories of lengths of roughly 30 cm. This design reduces the number of electrodes necessary to guide the ion beam through the ring in stable orbits. The six elements (deflectors and mirrors) are placed on a common grounded plate - the tabletop. Here, we present the design, ion trajectory simulations, and results of the first test experiments demonstrating the successful room-temperature operation of Mini-Ring at background pressures of 10{sup -6}-10{sup -7} mbar.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Ion Cooling and State Characterization Apparatus for Studies of Molecular Ion Dissociative Interactions

An experimental capability is being developed at the Oak Ridge National Laboratory Multi-Charged Ion Research Facility (ORNL MIRF) to enable stored cooling and state characterization of molecular ions of essentially any mass. Ions selected from a variety of available sources are injected from the side into a 1.5 meter long electrostatic mirror trap, where excited internal states are cooled by radiative cooling. An electron beam target located near the middle of the ion-trap region, coupled with neutral fragment imaging detector systems at each end of the trap, permits state-specific studies of electron-molecular ion dissociation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron caustic lithography

A maskless method of electron beam lithography is described which uses the reflection of an electron beam from an electrostatic mirror to produce caustics in the demagnified image projected onto a resist-coated wafer. By varying the electron optics, e.g. via objective lens defocus, both the morphology and dimensions of the caustic features may be controlled, producing a range of bright and tightly focused projected features. The method is illustrated for line and fold caustics and is complementary to other methods of reflective electron beam lithography.

43 PARTICLE ACCELERATORS↗

Development of analytically capable time-of-flight mass spectrometer with continuous ion introduction

The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 {mu}s. Accordingly, the sample is under excitation in 10{sup -4} part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 10{sup 10} V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical calculations as well as the future potentiality for use in chemical analysis of gaseous mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A bent electrostatic ion beam trap for simultaneous measurements of fragmentation and ionization of cluster ions

We describe a bent electrostatic ion beam trap in which cluster ions of several keV kinetic energy can be stored on a V-shaped trajectory by means of an electrostatic deflector placed between two electrostatic mirrors. While maintaining all the advantages of its linear counterpart [Zajfman et al., Phys. Rev. A 55, R1577 (1997); Dahan et al., Rev. Sci. Instrum. 69, 76 (1998)], such as long storage times, straight segments, and a field-free region for merged or crossed beam experiments, the bent trap allows for simultaneous measurement of charged and neutral fragments and determination of the average kinetic energy released in the fragmentation. These unique properties of the bent trap are illustrated by first results concerning the competition between delayed fragmentation and ionization of Al{sub n}{sup -} clusters after irradiation by a short laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of position-sensitive time-of-flight spectrometer for fission fragment research

A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.

2E-2v↗

Molecular Ion Dissociation Processes in a Partially Cooled Electrostatic Trap

An experimental capability being developed at the Oak Ridge National LaboratoryMulti-Charged Ion Research Facility (ORNL MIRF) is described that enables stored cooling andstate characterization of atomic and molecular ions of essentially any mass. Ions selected from avariety of available (hot and cold) sources are injected into a 1.5 meter long electrostatic mirrortrap, in which excited internal states decay by radiative cooling. Ion lifetime studies or directmeasurements of ‘in-trap’ interactions of molecular ions with electrons or atomic targets areaccomplished with either a crossed electron beam or atomic beam (with recoil ion detection)located in the field-free region of the ion-trap, coupled with product velocity imaging. Similarly,extraction of trap-cooled ions can be used ‘out-of-trap’ for near state-specific electron capture(EC) and dissociative charge exchange (DCE) studies employing higher resolution COLTRIMStechniques coupled with fragment imaging.

74 ATOMIC AND MOLECULAR PHYSICS↗

On a two-pass scheme without a faraday mirror for free-space relativistic quantum cryptography

The stability of destructive interference independent of the input polarization and the state of a quantum communication channel in fiber optic systems used in quantum cryptography plays a principal role in providing the security of communicated keys. A novel optical scheme is proposed that can be used both in relativistic quantum cryptography for communicating keys in open space and for communicating them over fiber optic lines. The scheme ensures stability of destructive interference and admits simple automatic balancing of a fiber interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Massive, long-lived electrostatic potentials in a rotating mirror plasma

Abstract Hot plasma is highly conductive in the direction parallel to a magnetic field. This often means that the electrical potential will be nearly constant along any given field line. When this is the case, the cross-field voltage drops in open-field-line magnetic confinement devices are limited by the tolerances of the solid materials wherever the field lines impinge on the plasma-facing components. To circumvent this voltage limitation, it is proposed to arrange large voltage drops in the interior of a device, but coexist with much smaller drops on the boundaries. To avoid prohibitively large dissipation requires both preventing substantial drift-flow shear within flux surfaces and preventing large parallel electric fields from driving large parallel currents. It is demonstrated here that both requirements can be met simultaneously, which opens up the possibility for magnetized plasma tolerating steady-state voltage drops far larger than what might be tolerated in material media.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrons Confined with an Axially Symmetric Magnetic Mirror Field

Low energy non-neutral electron plasmas were confined with an axially symmetric magnetic mirror field and an electrostatic potential to investigate the basic confinement properties of a simple magnetic mirror trap. As expected the confinement time became longer as a function of the mirror ratio. The axial electrostatic oscillations of a confined electron plasma were also observed. Obtained results suggested an improved scheme to accumulate low energy charged particles with the use of a magnetic mirror field, which would enable the investigation of electron-positron plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of effect of electron cyclotron heating in a tandem mirror plasma using a semiconductor detector array and an electrostatic energy analyzer

Temporally and spatially resolved soft x-ray and end-loss-electron analyses of the electron cyclotron heated plasmas are carried out by using a semiconductor detector array and an electrostatic energy analyzer in the GAMMA 10 tandem mirror. The flux and the energy spectrum of the end loss electrons are measured by a multi-grid energy analyzer. Recently, the electron cyclotron heating power modulation experiments have been started in order to generate and control the high heat flux and to make the edge localized mode-like intermittent heat load pattern for the divertor simulation studies by the use of these detectors for electron properties.

43 PARTICLE ACCELERATORS↗

Density and potential profiles of non-neutral electron plasmas in a magnetic mirror field

Low-energy non-neutral electron plasmas were confined with an electrostatic potential and a magnetic mirror field of the mirror ratio up to 5. Using a conventional phosphor screen and the unique multiring trap, both radial and axial density profiles of plasmas were measured. With the present experimental parameters, it was confirmed that a plasma density increased at higher field with an electrostatic confinement and that it decreased at higher field with a magnetic mirror confinement. The electrostatic potentials along the magnetic field were estimated with computer simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic mirror effects on a collisionless plasma in a convergent geometry

Several plasma thruster concepts, as well as ion engine chambers, use magnetic cusps to protect walls and to throttle electron flow to anodes. We present a kinetic model of the plasma in the vicinity of one cusp. Electrons, strongly confined by the electrostatic presheath and sheath, are assumed isotropic. Collisionless ions are either magnetically guided or completely nonmagnetized, thus bracketing conditions of interest. For magnetized ions, electrostatic and magnetic mirror forces compete, and the resulting self-consistent potential is found by imposing quasineutrality. A similar competition occurs for nonmagnetized ions, this time as a result of the convergence of equipotential lines. Analytical solutions are found for monoenergetic ions, and these are generalized to the case of an initially Maxwellian population, for which some numerical iteration is required. The presheath potential drop is in all cases of the order of 0.6-0.75 times the electron temperature, and ions enter the sheath at a sonic velocity, according to Bohm's criterion. Contrary to intuition, the cusp does not reduce the ion flux (per unit area) to the wall, only the size of the wall area section that carries this flux by virtue of its connection to the distant plasma. These kinetic results are verified by checking the conservation of relevant moments of the ion distribution, including two new quantities that generalize the average magnetic moment and the total ion enthalpy by accounting for the nonzero ion heat fluxes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superharmonic resonances in a two-dimensional non-linear photonic-crystal nano-electro-mechanical oscillator

We investigate the non-linear mechanical dynamics of a nano-optomechanical mirror formed by a suspended membrane pierced by a photonic crystal. By applying to the mirror a periodic electrostatic force induced by interdigitated electrodes integrated below the membrane, we evidence superharmonic resonances of our nano-electro-mechanical system; the constant phase shift of the oscillator across the resonance tongues is observed on the onset of principal harmonic and subharmonic excitation regimes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗