Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROSTATIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Effect of CO 2 on the Measurement of 220 Rn and 222 Rn with Instruments Utilising Electrostatic Precipitation

In some volcanic systems, thoron and radon activity and CO 2 flux, in soil and fumaroles, show a relationship between ( 220 Rn/ 222 Rn) and CO 2 efflux. It is theorized that deep, magmatic sources of gas are characterized by high 222 Rn activity and high CO 2 efflux, whereas shallow sources are indicated by high 220 Rn activity and relatively low CO 2 efflux. In this paper we evaluate whether the observed inverse relationship is a true geochemical signal, or potentially an analytical artifact of high CO 2 concentrations. We report results from a laboratory experiment using the RAD7 radon detector, known 222 Rn (radon) and 220 Rn (thorn), and a controllable percentage of CO 2 in the carrier gas. Our results show that for every percentage of CO 2 , the 220 Rn reading should be multiplied by 1.019, the 222 Rn radon should be multiplied by 1.003 and the 220 Rn/ 222 Rn ratio should be multiplied by 1.016 to correct for the presence of the CO 2 .

58 GEOSCIENCES↗

Study of a comet rendezvous mission. Volume 2: Appendices

Appendices to the comet Encke rendezvous mission consider relative positions of comet, earth and sun; viewing condition for Encke; detection of Taurid meteor streams; ephemeris of comet Encke; microwave and optical techniques in rendezvous mission; approach instruments; electrostatic equilibrium of ion engine spacecraft; comet flyby data for rendezvous spacecraft assembly; observations of P/Encke extracted from a compilation; and summary of technical innovations.

Source record↗

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Instrument Development

The Electrostatic Regolith Interaction Experiment (ERIE) is a joint venture between the University of Central Florida (UCF) Center for Microgravity Research (CMR) and the NASA Kennedy Space Center (KSC) Electrostatics and Surface Physics Laboratory (ESPL) seeking to examine charged dust grain behavior in a microgravity environment. Two separate systems have been combined for this suborbital flight experiment: the COLLisions Into Dust Experiment (COLLIDE) developed by the UCF CMR and the Wheel Electrostatic Spectrometer (WES) developed by the NASA KSC ESPL. This combination will advance the understanding of the natural and induced charged grain behavior on the Moon, asteroids, and other low gravity bodies comprised of charged dust particles. COLLIDE retains granular material under vacuum in a shallow tray behind a metal door, which then opens and releases the particles into a larger open volume when microgravity is achieved. The experiment is observed with a high-speed camera, such that the motions of these particles can then be tracked so the kinematics of each grain may be analyzed. The original application for this apparatus was to study cratering events into granular beds, but electrostatic repulsion was detected in the early frames of the video data returned from completed experiments, so a re-flight with a focus on these events was proposed. Agitation of the grains during launch combined with the frictional charge transfer between the grains and the door as it slides open provides an opportunity to use this setup to observe material tribocharging and charged particle behaviors in microgravity. In this updated version, the charged particles released into the chamber will traverse through an electric field produced by high voltage parallel plates and their resulting trajectories will be determined by their net charges. WES was originally developed to characterize the triboelectric properties of the Martian regolith through the contact of a rover wheel with the surface as it rotates. Improvements were made upon this legacy system to develop a sensor suite that will be installed within the COLLIDE door to measure charge transferred between the granular material and insulating disks protruding through the door. These insulator disks span the triboelectric series so, as they slide across the particulate matter when the door opens, each will accumulate a charge consistent with its relative position to the grains within the series. This charge on each insulator is distributed between two capacitances in series with an electrometer amplifier returning an analog voltage proportional to the charge accumulated. Calibration of this system has been performed using applications of known charge to the inputs and characterization of the frictional charge transfer between various regolith simulants and the sensor insulators is currently being examined in the lab.

Electrostatics↗

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Instrument Development

The Electrostatic Regolith Interaction Experiment (ERIE) is a joint venture between the University of Central Florida (UCF) Center for Microgravity Research (CMR) and the NASA Kennedy Space Center (KSC) Electrostatics and Surface Physics Laboratory (ESPL) seeking to examine charged dust grain behavior in a microgravity environment. Two separate systems have been combined for this suborbital flight experiment: the COLLisions Into Dust Experiment (COLLIDE) developed by the UCF CMR and the Wheel Electrostatic Spectrometer (WES) developed by the NASA KSC ESPL. This combination will advance the understanding of the natural and induced charged grain behavior on the Moon, asteroids, and other low gravity bodies comprised of charged dust particles.

Electrostatics↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

SWICS/Ulysses and MASS/wind observations of solar wind sulfur charge states

As Ulysses journeys from the southern to the northern solar pole, the newly launched Wind spacecraft is monitoring the solar wind near 1 AU, slightly upstream of the Earth. Different solar wind structures pass over both spacecraft as coronal holes and other features rotate in and out of view. Ulysses and Wind are presently on opposing sides of the sun allowing us to monitor these streams for extended periods of time. Composition measurements made by instruments on both spacecraft provide information concerning the evolution and properties of these structures. We have combined data from the Solar Wind Ion Composition Spectrometer (SWICS) on Ulysses and the high mass resolution spectrometer (MASS) on Wind to determine the charge state distribution of sulfur in the solar wind. Both instruments employ electrostatic deflection with time-of-flight measurement. The high mass resolution of the MASS instrument (M/Delta-M approximately 100) allows sulfur to be isolated easily while the stepping energy/charge selection provides charge state information. SWICS measurements allow the unique identification of heavy ions by their mass and mass/charge with resolutions of M/Delta-M approximately 3 and M/q/Delta(M/q) approximately 20. The two instruments complement each other nicely in that MASS has the greater mass resolution while SWICS has the better mass/charge resolution and better statistics.

Cohen, C. M. S.↗

The integrated miniaturized electrostatic analyzer: A space plasma environment sensor

The integrated Miniaturized Electrostatic Analyzer (iMESA) was a satellite-based ionospheric sensor that operated on NASA’s Space Test Program Satellite (STPSat-3) from December 2013 to July 2019. The instrument’s scientific objective was to (1) measure the plasma density in low Earth orbit, (2) measure the plasma temperature in low Earth orbit, and (3) quantify the spacecraft potential with respect to the ambient plasma potential in the ionosphere. iMESA sampled the ionosphere every 10 s by measuring the ion current density through the ESA as a result of the motion of the spacecraft through the plasma. Current density spectra were transmitted to the ground where they were post-processed into ion density spectra and then analyzed numerically to determine the ion density, ion temperature, and spacecraft potential. This article discusses the instrument design and simulation, the determination of a geometric factor, and data processing procedures and evaluates the final data product with regard to the mission success criteria. Here, the ion density and ion temperature captured by the iMESA instrument are on the same order and range as the values predicted in the literature. The spacecraft potential was also quantified. The conclusion after the evaluation of the instrument’s data product is that the scientific mission is successful on all three points.

47 OTHER INSTRUMENTATION↗

Micro-spectrometer for fusion plasma boundary measurements

In situ probes are being developed to make direct, spatially resolved measurements of the ion energy spectra in the edge of tokamak plasmas while being easily replaced and requiring minimal resources. The ion spectrometers will consist of a combined collimator and energy analyzer fabricated from silicon and mated to a detector to yield a form factor of approximately 2.0 cm × 1.5 cm × 0.2 cm. Results of fabrication and testing of the combined collimator and energy analyzer element are presented.

47 OTHER INSTRUMENTATION↗

Development of an electrostatic positioner for space material processing

This paper describes an electrostatic positioning instrument which was developed at the Jet Propulsion Laboratory to enable experimenters to conduct containerless material science experiments in space. Samples that are to be studied are electrically charged and controlled by the electrostatic force produced by a set of properly arranged electrodes. Three different types of positioners are described, i.e., the dish type, the ring type, and the tetrahedral type. In all these systems, the positioning and the damping of the sample is accomplished by a feedback control system. The advantage of this electrostatic positioning method, in comparison to the other methods, such as acoustic and electromagnetic, lies in the fact that it can operate in a high vacuum and does not require the material to be electrically conductive as long as the material can carry a certain amount of charge.

Rhim, W. K.↗

The Ring Current ENA Instrument on the NASA STORIE Mission

NASA has recently selected the Storm Time O+ Ring current Imaging Evolution (STORIE) mission to study the evolution of Earth’s ring current and the role of composition and dynamics during geomagnetic storms. STORIE addresses this inner magnetospheric science through the use of a Ring current Energetic Neutral Atom (RENA) instrument hosted on the International Space Station (ISS). This novel vantage point for ENA imaging has a number of scientific and implementation advantages. RENA is a high sensitivity remote sensing ENA imager and composition instrument with a field of view of 90 x 2 degrees, and an angular resolution of 2 x 2 degrees. The instrument aperture points zenith and its long dimension is oriented perpendicular to the ISS ram direction. As a result, RENA acts as a “push broom” imager building up a complete sky scan of the ring current in a single 90-minute ISS orbit. The instrument employs electrostatic optics along with a foil-MCP TOF x PHA x Delay-Line position measurement technique to resolve H and O energy spectra in the energy range 10-500 KeV for each look direction. Furthermore, it employs triple+ time and position coincidence to effectively reduce background noise from geocoronal and black sky UV as well as penetrating radiation. The abundant mass, power, and telemetry, resources of the ISS allow for large instrument aperture, very high sensitivity, complex data product and simplified operations, altogether contributing towards a high signal to noise (S/N) measurement.

Space Science↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗