Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRONIC TRANSDUCER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

System and method for acoustic to electronic transduction

According to various embodiments, a system for acoustic to electronic transduction is disclosed. The system includes a transducing medium configured to convert a received acoustic signal into a transduced electronic signal when a voltage is applied. The system further includes a high-pass filter coupled to the transducing medium, the high-pass filter configured to isolate the transduced signal from the applied voltage.

Carlsson, Johan A.↗

Surface-Mediated Interconnections of Nanoparticles in Cellulosic Fibrous Materials toward 3D Sensors

Fibrous materials serve as an intriguing class of 3D materials to meet the growing demands for flexible, foldable, biocompatible, biodegradable, dis- posable, inexpensive, and wearable sensors and the rising desires for higher sensitivity, greater miniaturization, lower cost, and better wearability. The use of such materials for the creation of a fibrous sensor substrate that interfaces with a sensing film in 3D with the transducing electronics is however difficult by conventional photolithographic methods. Here, a highly effective pathway featuring surface-mediated interconnection (SMI) of metal nanoclusters (NCs) and nanoparticles (NPs) in fibrous materials at ambient conditions is demon- strated for fabricating fibrous sensor substrates or platforms. Bimodally distrib- uted gold–copper alloy NCs and NPs are used as a model system to demonstrate the semiconductive-to-metallic conductivity transition, quantized capacitive charging, and anisotropic conductivity characteristics. Upon coupling SMI of NCs/NPs as electrically conductive microelectrodes and surface-mediated assembly (SMA) of the NCs/NPs as chemically sensitive interfaces, the resulting fibrous chemiresistors function as sensitive and selective sensors for gaseous and vaporous analytes. Finally, this new SMI–SMA strategy has significant implications for manufacturing high-performance fibrous platforms to meet the growing demands of the advanced multifunctional sensors and biosensors.

36 MATERIALS SCIENCE↗

Self-powered Through-wall communication for dry cask storage monitoring

Many nuclear facilities, such as spent fuel storage dry casks and nuclear reactor pressure vessels, are entirely sealed by metal layers to prevent harmful radiation. For safety and security operations, the temperature, pressure, radiation, and humidity inside the vessel needs to be closely monitored. However, no practical technology is currently available to realize the through-wall data communication and monitoring for these vessels due to the inside harsh environment of high temperature and nuclear radiation. In this paper, an innovative self-powered wireless through-wall data communication system for the nuclear environment is presented, which demonstrates a successful solution to such challenges. The presented system is composed of four modules, i.e., energy harvester with power management circuits, ultrasound wireless communication using high-temperature piezoelectric transducers, electronic circuits for sensing and data transmission, and radiation shielding for electronics. Here, constitutive functions of each module were firstly designed and followed by the system integration. Experiments were conducted subsequently to validate the designed functions and evaluate the performance of the integrated system. Results showed that the average power of over 40 mW was harvested from the thermal flow inside the nuclear spent fuel canisters which could provide enough energy to operate the sensing and data communication systems. The gamma radiation test results showed that the thermoelectric energy harvester and ultrasound transceivers can withstand radiation dosing over 100 Mrad. Furthermore, temperature shock tests demonstrated that the entire system including the shielded electronics can survive and maintain their functionalities at temperatures as high as 195°C. Under the in-lab mocked-up high temperature conditions and radiation shielding, the proposed system is foreseen to survive and operate stably for fifty years inside a nuclear spent fuel canister, and send the frequency modulated data out of the canister for 3 s in every 10 min.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ESSENCE- A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules

The rapid, sensitive, and selective detection of target analytes using electrochemical sensors are challenging. ESSENCE, a new Electrochemical Sensor that uses a Shear-Enhanced, flowthrough Nanoporous Capacitive Electrode, overcomes current electrochemical sensors' response limitations, selectivity, and sensitivity limitations. ESSENCE is a microfluidic channel packed with transducer material sandwiched by a top and bottom microelectrode. The room-temperature instrument less integration process allows the switch of the transducer materials to make up the porous electrode without modifying the electrode architecture or device protocol. ESSENCE can be used to detect both biomolecules and small molecules by simply changing the packed transducer material. Electron microscopy results confirm the high porosity. In conjunction with the non-planar interdigitated electrode, the packed transducer material results in a flow-through porous electrode. Electron microscopy results confirm the high porosity. The enhanced shear forces and increased convective fluxes disrupt the electric double layer's (EDL) diffusive process in ESSENCE. This disruption migrates the EDL to high MHz frequency allowing the capture signal to be measured at around 100 kHz, significantly improving device timing (rapid detection) with a low signal-to-noise ratio. The device’s unique architecture allows us multiple configuration modes for measuring the impedance signal. This allows us to use highly conductive materials like carbon nanotubes. We show that by combining single-walled carbon nanotubes as transducer material with appropriate capture probes, NP-µIDE has high selectivity and sensitivity for DNA (fM sensitivity, selective against non-target DNA), breast cancer biomarker proteins (p53, pg/L sensitivity, selective against non-target HER2).

Cheng, Yu-Hsuan↗

Systems for Transducing Entanglement Between Photons and Electron Spins

The transfer of quantum properties and entanglement between photons and matter (transduction) is a major challenge in QIS, especially with regard to networking quantum information processing. In order to overcome this challenge, it is important to know how non-classical light (single or entangled photons) interacts with matter. This project specifically addresses fundamental questions about the interaction of single and entangled photons with molecules and nanostructures to produce electrons with prescribed spin polarizations and pairs of electrons with entangled spins, thus resulting in transduction by addressing two major objectives: (2) In Objective 1, we will investigate the formation of polarization-encoded radical (spin qubit) pairs and molecular triplet states photoexcited by single quantum emitter light sources. (2) In Objective 2, we will demonstrate the use of two entangled photons, generated by spontaneous parametric down conversion (SPDC) or by the coherent biexcitonic states of perovskite NPLs, to produce two entangled radical (spin qubit) pairs or molecular triplet states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Large Area Detection of Microstructural Defects with Multi-Mode Ultrasonic Signals

Cyclic loading or other stresses can lead to development of cracks and crack growth in mechanical structures, leading to eventual failure. While ultrasound imaging can be used for non-destructive testing of such structures, conventional ultrasound techniques are often limited by crack size, density, and areal coverage. An effective characterization of real-world, large-area structures is required at an early damage stage to prevent catastrophic failure and predict remaining life. In this study, a new nonlinear ultrasonic testing (NUT) method is proposed for large-area monitoring of practical structures with arbitrary complexity by using multiple-mode guided-wave ultrasonic signals. The proposed guided-wave NUT technique requires single-element transducers, simple electronics, and a mixed time-frequency domain signal processing. As a proof-of-concept demonstration, numerical simulations and experiments are performed on an A36 carbon steel beam assembly with previously formed microstructural defects that cause nonlinearities in ultrasonic response. The quadratic dependence of the nonlinear wave excitation on the input ultrasonic signal amplitude is shown by numerical simulations, and such a nonlinear ultrasonic response is experimentally observed in the zone with a high density of microstructural defects.

36 MATERIALS SCIENCE↗

Electronic Scanning Strategies in Adaptive Electrical Capacitance Volume Tomography: Tradeoffs and Prospects

Electrical Capacitance Volume Tomography (ECVT) has been applied for imaging of multiphase flows found in industrial applications. The ill-posed nature of the image reconstruction problem in ECVT and the consequent low resolution can be alleviated by employing electronic scanning enabled by electrode segmentation and reconfiguration during data acquisition. Here we study electronic scanning strategies that mimic physical rotation and shifting of the sensor along its symmetry axis. First, we study the feasibility of electronic scanning by analyzing the capacitance transducer circuit in SPICE. Then, we simulate electronic scanning using the finite element method for different electrode shapes, for which we compare the image reconstruction results and acquisition time. We find a noticeable improvement in image resolution for the scanning cases over conventional ECVT. Lastly, among the scanning cases, we emphasize a particular electrode shape that provides the best image resolution along with the minimal amount of acquisition time.

47 OTHER INSTRUMENTATION↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗

Studying light–matter interactions and energy transfer at the nanoscale with a trapped–ion quantum computer

A grand challenge in materials sciences is to control energy transduction, transfer and dissipation at the nanoscale. Meeting this challenge requires progress in nanoscale fabrication and synthesis, but equally importantly, also progress in our understanding of how nanoscale structure influences these phenomena. Although detailed quantum mechanical models exist that capture the structure and physics of materials and molecular species, solving these models to calculate the relevant emergent phenomena, which often occur over vastly different time and energy scales, has so far proven difficult. In this project, we studied how to model energy transfer and light-matter interactions using trapped-ion quantum computers. Our studies focused on emulation of critical processes in natural systems, such as the well-known photosynthetic pigment-protein complexes responsible for capturing and transducing light to electrons. In addition, we implemented proof-of-principle experiments demonstrating that such calculations are possible on trapped-ion quantum computing hardware. These studies and experiments pave the way to investigate energy transport and transduction in a detail not accessible with classical computing technologies. We expect that our studies will allow to extract important guiding principles on how to improve the efficiency of nano-scale light-harvesting and transduction devices.

36 MATERIALS SCIENCE↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrafast structural changes within a photosynthetic reaction centre

Photosynthetic reaction centres harvest the energy content of sunlight by transporting electrons across an energy-transducing biological membrane. In this study we use time-resolved serial femtosecond crystallography using an X-ray free-electron laser to observe light-induced structural changes in the photosynthetic reaction centre of Blastochloris viridis on a timescale of picoseconds. Structural perturbations first occur at the special pair of chlorophyll molecules of the photosynthetic reaction centre that are photo-oxidized by light. Electron transfer to the menaquinone acceptor on the opposite side of the membrane induces a movement of this cofactor together with lower amplitude protein rearrangements. These observations reveal how proteins use conformational dynamics to stabilize the charge-separation steps of electron-transfer reactions.

59 BASIC BIOLOGICAL SCIENCES↗

Tuning Organic Electrochemical Transistor Threshold Voltage using Chemically Doped Polymer Gates

Organic electrochemical transistors (OECTs) have shown promise as transducers and amplifiers of minute electronic potentials due to their large transconductances. Tuning the OECT threshold voltage is important to achieve low-powered devices with amplification properties within the desired operational voltage range. However, traditional design approaches have struggled to decouple channel and materials properties from threshold voltage, thereby compromising on several other OECT performance metrics, such as electrochemical stability, transconductance, and dynamic range. In this work, simple solution-processing methods are utilized to chemically dope polymer gate electrodes, thereby controlling their work function, which in turn tunes the operation voltage range of the OECTs without perturbing their channel properties. Chemical doping of initially air-sensitive polymer electrodes further improves their electrochemical stability in ambient conditions. Thus, OECTs that are simultaneously low-powered and electrochemically resistant to oxidative side reactions under ambient conditions are demonstrated. Furthermore, this approach shows that threshold voltage, which is once interwoven with other OECT properties, can in fact be an independent design parameter, expanding the design space of OECTs.

chemical doping↗

Acoustoelectric drag current in vanadium oxide films

Two different Mott insulator wires, vanadium dioxide and vanadium sesquioxide, were prepared on the piezoelectric LiNbO 3 substrates. Coupling of acoustic waves propagating in LiNbO 3 with free carriers in vanadium oxide gives rise to the acoustoelectric effect that manifests itself as the generation of direct electric current by the acoustic wave. According to a phenomenological model, the value of the effect strongly depends on the wires conductivity, which, for the vanadium-oxide films, changes by a few orders of magnitude. We demonstrated that this yields a significant enhancement of the direct current (DC) current generated in the wires at the metal–insulator transition temperatures. The sign of the generated DC voltage is different for excitations by surface and bulk acoustic wave modes, which may happen due to reverse wave propagation at the substrate surface. For each resonance mode, polarities of the generated DC signal are the same in both wires, despite the signs of charge carriers being different for these materials. It was shown that two complementary techniques (acoustoelectric and Hall effect measurements) yield opposite signs of charge carriers in VO 2 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent electrical control of a single high-spin nucleus in silicon

Nuclear spins are highly coherent quantum objects. In large ensembles, their control and detection via magnetic resonance is widely exploited, for example, in chemistry, medicine, materials science and mining. Nuclear spins also featured in early proposals for solid-state quantum computers and demonstrations of quantum search and factoring algorithms. Scaling up such concepts requires controlling individual nuclei, which can be detected when coupled to an electron. However, the need to address the nuclei via oscillating magnetic fields complicates their integration in multi-spin nanoscale devices, because the field cannot be localized or screened. Control via electric fields would resolve this problem, but previous methods relied on transducing electric signals into magnetic fields via the electron–nuclear hyperfine interaction, which severely affects nuclear coherence. In this work, we demonstrate the coherent quantum control of a single 123 Sb (spin-7/2) nucleus using localized electric fields produced within a silicon nanoelectronic device. The method exploits an idea proposed in 1961 but not previously realized experimentally with a single nucleus. Our results are quantitatively supported by a microscopic theoretical model that reveals how the purely electrical modulation of the nuclear electric quadrupole interaction results in coherent nuclear spin transitions that are uniquely addressable owing to lattice strain. The spin dephasing time, 0.1 seconds, is orders of magnitude longer than those obtained by methods that require a coupled electron spin to achieve electrical driving. These results show that high-spin quadrupolar nuclei could be deployed as chaotic models, strain sensors and hybrid spin-mechanical quantum systems using all-electrical controls. Integrating electrically controllable nuclei with quantum dots could pave the way to scalable, nuclear- and electron-spin-based quantum computers in silicon that operate without the need for oscillating magnetic fields.

42 ENGINEERING↗

Simplified feedback control system for scanning tunneling microscopy

A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between the tip and the sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here, we discuss another approach using a computer and data acquisition through the universal serial bus port. We find that it allows successful ultralow noise studies of surfaces at cryogenic temperatures. We show results on different compounds including a type II Weyl semimetal (WTe2), a quasi-two-dimensional dichalcogenide superconductor (2H–NbSe2), a magnetic Weyl semimetal (Co3Sn2S2), and an iron pnictide superconductor (FeSe).

Martín-Vega, Francisco (ORCID:0000000333177833)↗

Large Propagation-Direction-Dependent Circularly Polarized Emission and Scattering Anisotropies of a Chiral Organic-Inorganic Semiconductor

Chiral materials are important tools for transducing circularly polarized light within many emerging opto-electronic and spin-based technologies. Here, we demonstrate that thin films of a bismuth iodide-based 0D chiral hybrid organic-inorganic semiconductor (HOIS) exhibit large anisotropy values in circularly polarized light emission (CPLE) that approach 50%, with mirror-image responses from front- and back-side measurements. A comprehensive analysis of light-wave propagation, absorption, emission, and scattering is constructed on the basis of a symmetry-derived exciton fine structure model, which accurately describes the direction and polarization dependence of the observed excitonic circular dichroism and CPLE, including contributions from both photoluminescence and resonant Raman scattering. Our analysis indicates that molecular chirality drives preferential film alignment with respect to the out-of-plane lattice vector direction, producing the observed anisotropies. This first demonstration in an HOIS system provides a unique route for enhancing polarization-dependent emission, and circularly polarized light transduction more broadly, in self-assembled HOIS.

14 SOLAR ENERGY↗

From photosynthetic electron flow to gene regulation: redox signal transduction in cyanobacteria

In cyanobacteria, the free-living ancestors of chloroplasts, photosynthesis simultaneously sustains growth and generates reactive oxygen species (ROS) that damage proteins, lipids, and DNA when light capture outpaces carbon fixation. Maintaining redox balance, therefore, requires cells to read photosynthetic electron flow as a signal that continuously tunes gene expression and protein activity. This review traces how these redox signals are transduced to transcription machinery through three routes: membrane-localized sensors, cytoplasmic redox sensors downstream of photosystem I, and ROS generated when electron sinks are saturated. Membrane-bound histidine kinases (two-component systems) relay the redox state of the plastoquinone pool to control photosystem remodeling, pigment biosynthesis, and circadian timing. Cytoplasmic one-component regulators, by contrast, sense redox directly through thiol-disulfide switches, glutathionylation, iron-sulfur clusters, and metal-catalyzed oxidation to control photosystem-cofactor, electron-carrier, and transition-metal homeostasis. Because many of these regulators persist in algal and plant chloroplasts, cyanobacteria illuminate principles of redox control across photosynthetic eukaryotes. Post-transcriptional and translational control further shapes redox-dependent gene expression programs through transcript stability, ribosome assembly, and translation initiation, extending redox regulation beyond transcription to every step of protein synthesis and even activity modulation. Finally, we connect redox regulation to photosynthetic physiology, stress resilience, and the rational engineering of cyanobacteria for sustainable bioproduction.

59 BASIC BIOLOGICAL SCIENCES↗