Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ELECTRON TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NOVEL METHODS FOR IN SITU HIGH DENSITY SURFACE CLEANING SCRUBBING OF ULTRAHIGH VAC LONG NARROW TUBES TO REDUCE SECONDARY ELECTRON YIELD AND OUT GASSING

This project developed new methods for cleaning the inside surfaces of very long, narrow vacuum tubes used in particle accelerators. Traditional cleaning approaches are expensive, slow, or difficult to implement in accelerator tunnels. We designed and tested a portable plasma discharge cleaning system that uses lower-cost microwave and magnetron technologies to reduce outgassing and secondary electron emission from stainless steel and copper surfaces. The system, called the Plasma Discharge Test System (PDTS), allows accelerator components to be scrubbed more efficiently, which can improve performance and reduce maintenance costs for research and industrial applications.

POOLE, JOE HENRY [PRESIDENT]

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Corrosion Resistance of an AlCeMg/Stainless-Steel Reactive Bond

A major issue for metal components in many industries is corrosion as it can substantially reduce their lifetime. This issue is especially problematic for materials used in heat exchanger applications. Al–Ce–Mg alloys, which exhibit corrosion resistance and can reactively bond with other metals, may be a viable solution to this problem. This investigation studied the corrosion behavior of Al–2Ce–6Mg (atomic percent)/stainless-steel (SS) reactive bond interfaces after full immersion in nitric, sulfuric, formic, and mixed acid for 267 h. This particular Al–Ce–Mg alloy was chosen due to its good castability. The results of scanning electron microscope characterization showed that reactive bond formations repeatedly occurred throughout the length of the casting in the as-cut samples and that these formations maintained a secure bonding between the alloy and the stainless-steel tubes. Transmission electron microscopy results showed that there was a clear compositional and microstructural transition across the reactive bond. The results of the immersion tests indicated that the nitric, sulfuric, and the mixed acid did not have an observably negative effect on the reactive bond structure. As for the sample exposed to formic acid only, noticable changes were seen in both the microstructural appearance and the elemental profile across the bond, suggesting that oxide formation occurred.

Brechtl, Jamieson [ORNL] (ORCID:0000000217394283)

Hot electron preheat effects in two-photon polymerization plastic lattice laser-driven shock-tube experiments on the OMEGA laser

We present simulations of Omega shock tube experiments designed to investigate hot electron preheat effects in 3D-printed, two-photon polymerization (2PP) plastic lattices. Preheat is inferred in the experiments from the expansion of a plastic witness disk embedded in the lattice. Using the Eulerian radiation-hydrodynamics code xRAGE, we model shock propagation and preheat from both radiative and hot electron energy sources to evaluate their relative impact. To simulate the transport of laser-generated hot electrons, the nonlocal electron heat transport model proposed by Schurtz, Nicolaï, and Busquet (SNB) is extended with a hot electron source term and an energy cascade algorithm. We explore how variations in ablator, lattice geometry, and laser drive affect the shock velocity and witness disk expansion. Simulations show that the inclusion of a 5 μm gold layer reduces shock pressure by 60% and shock speeds by 30%–40% but does not significantly reduce the hot electron preheat, and that different lattice geometries lead to enhanced shock velocities—up to 40% faster than in homogeneous foams. However, radiative and conductive preheat from classical mechanisms alone fail to match experiment. By including a hot electron source term, we reproduce experimental observables such as disk expansion rates and spatial radiographic features. We find that a hot electron population corresponding to 4%–8% of the incident laser energy with T hot = 50 keV produces expansion which agrees with the experimental data, suggesting hot electron preheat is the most plausible explanation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Ion-temperature- and density-gradient-driven instabilities and turbulence in Wendelstein 7-X close to the stability threshold

Electrostatic gyrokinetic instabilities and turbulence in the Wendelstein 7-X stellarator are studied. Particular attention is paid to the ion-temperature-gradient (ITG) instability and its character close to marginal stability [Floquet-type turbulence (Zocco et al., Phys. Rev. E, vol. 106, 2022, p. L013202) with no electron temperature gradient]. The flux tube version of the δƒ code stella (Barnes et al., J. Comput. Phys., vol. 391, 2019, pp. 365–380) is used to run linear and nonlinear gyrokinetic simulations with kinetic electrons. The nature of the dominant instability depends on the wavelength perpendicular to the magnetic field, and the results are conveniently displayed in stability diagrams that take this dependence into account. This approach highlights the presence of universal instabilities, which are less unstable but have longer wavelengths than other modes. A quasi-linear estimate of the heat flux suggests they are relevant for transport. Close to the stability threshold, the linear eigenmodes and turbulence form highly extended structures along the computational domain if the magnetic shear is small. Numerical experiments and diagnostics are undertaken to assess the resulting radial localisation of the turbulence, which affects the interaction of the latter with zonal flows. Increasing the amplitude of the magnetic shear (e.g.through current drive) has a stabilising effect on the turbulence and, thus, reduces the nonlinear energy transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION

Validation of a comprehensive first-principles-based framework for predicting the performance of future stellarators

This paper presents the validation of the GENE-KNOSOS-Tango framework for recovering both the steady-state plasma profiles in the considered radial domain and selected turbulence trends in a stellarator. This framework couples the gyrokinetic turbulence code GENE, the neoclassical transport code KNOSOS, and the transport solver Tango in a multi-timescale simulation feedback loop. Ion-scale kinetic-electron and electron-scale adiabatic-ion flux-tube simulations were performed to evolve the density and temperature profiles for four OP1.2b W7-X scenarios. The simulated density and temperature profiles showed good agreement with the experimental data using a reasonable set of boundary conditions. Equally important was the reproduction of observed trends for several turbulence properties, such as density fluctuations and turbulent heat diffusivities. Key effects were also touched upon, such as electron-scale turbulence and the neoclassical radial electric field shear. The validation of the GENE-KNOSOS-Tango framework enables credible predictions of physical phenomena in stellarators and reactor performance based on a given set of edge parameters.

Gyrokinetic simulations

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, currently under construction at the Fermi National Accelerator Laboratory (FNAL) in Batavia, Illinois, is a particle physics experiment designed to detect Charged Lepton Flavor Violation (CLFV) via muon-to-electron conversion, a process beyond the Standard Model (BSM). One of the primary Mu2e detectors is the Straw Tracker, whose purpose is to measure the momentum of the electron, identify the signal, and reject background. The straw tubes are being read out by a total of 20,736 preamplifiers (preamps) within 36 planes that make up the Tracker. In this presentation, the installation of electronics into the Tracker, the implementation of anti-oscillation copper clips, and the process of installing fully constructed planes into the frame will be discussed in depth.

Lynch, Alec [UC, Berkeley]

Analysis of the elliptic integrable non-linear system in IOTA using tracking of a single electron

Integrable nonlinear lattices that can be realized in practical accelerators are of great interest, as they offer the potential to support high-intensity beams via Landau damping of collective instabilities. One such system, based on an elliptic potential, has been extensively studied at the IOTA storage ring at Fermilab. The analysis of strongly nonlinear dynamics with multi-particle bunches is challenging due to the rapid decoherence of kicked beams. IOTA has the capability to track single electrons using linear multi-anode photomultiplier tubes for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology enables the full reconstruction of turn-by-turn positions and momenta in all three planes for a single particle. Using this apparatus, we measured the dependence of small-amplitude tunes on the strength of the nonlinear magnet, as well as tunes dependence on oscillations amplitudes.

Romanov, A. [Fermilab]

Analysis of the Elliptic Integrable Non-Linear System in IOTA Using Tracking of a Single Electron

Integrable nonlinear lattices that can be realized in practical accelerators are of great interest, as they offer the potential to support high-intensity beams via Landau damping of collective instabilities. One such system, based on an elliptic potential, has been extensively studied at the IOTA storage ring at Fermilab. The analysis of strongly nonlinear dynamics with multi-particle bunches is challenging due to the rapid decoherence of kicked beams. IOTA has the capability to track single electrons using linear multi-anode photomultiplier tubes for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology enables the full reconstruction of turn-by-turn positions and momenta in all three planes for a single particle. Using this apparatus, we measured the dependence of small-amplitude tunes on the strength of the nonlinear magnet, as well as tunes dependence on oscillations amplitudes.

Romanov, Aleksandr Leonidovich [Fermilab] (ORCID:0

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING

A subgrid model for electron-scale turbulent transport in global ion-scale gyrokinetic simulations of tokamak plasmas

A subgrid electron–temperature–gradient (ETG) model is demonstrated here which averages local electron-scale turbulence over intermediate scales in space and time to include in global ion–temperature–gradient (ITG) simulations. This approach results in ion-scale equations, which incorporate the electron heat transport from ETG turbulence and the effects of electron-scale turbulence on the ion scale. Flux-tube ETG Cyclone Base Case simulations are performed at different radial locations and a kinetic form of the flux is added to global ion-scale (IS) simulations as a source term. Analytic radial profiles of ETG heat flux are constructed and compared to flux-tube results at multiple radial locations. Different ratios of ITG to ETG heat flux levels are considered and the results of capturing ETG heat transport in global ion-scale simulations are discussed. The potential coupling of the ETG streamer potential and intermediate-scale zonal flows to the ion scale is further addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Forced 3D Reconnection in an Exponentially Separating Magnetic Field

We present a solvable scenario for 3D reconnection in a sheared magnetic field. We consider a localized external force that is applied slowly to a flux tube and then maintained, generating an Alfvénic perturbation that spreads along the field lines. Separation of the sheared field lines reduces the scale of the perturbation across the field, enhancing magnetic diffusion. For a fusion-motivated equilibrium with exponential field-line separation, we find a reconnection timescale proportional to 𝒮/ ln⁡ 𝒮 under magnetohydrodynamics (MHD) and to 𝒮 1/3 for semicollisional electron-only reconnection, where 𝒮 is the Lundquist number of the perturbed flux tube. We generalize these results to arbitrary magnetic geometries, showing that the semicollisional case is geometry independent. Interestingly, we find that slower field-line separation yields an increased reconnection rate in MHD.

Magnetic confinement fusion

Dynamics of HCN, HNC, and HNCO Formation in the 193 nm Photodissociation of Formamide

Formamide (NH 2 CHO) is the simplest molecule containing a peptide linkage [-NH-C($=$O)-], and it plays an essential role in the study of prebiotic chemistry. Exposure to UV irradiation allows formamide to decompose and act as a prebiotic feedstock in the formation of nucleobases and other necessary starting materials. The photodissociation mechanism of gaseous formamide at 193 nm is studied using (a) chirped-pulse Fourier transform millimeter-wave spectroscopy in the 260-290 GHz spectral region in a room-temperature flow-tube reactor at 1 mu bar pressure, (b) a combination of electronic structure theory, transition state theory, and quasiclassical trajectories, and (c) the Active Thermochemical Tables. The HCN and HNC photoproducts of hydrogenated (NH 2 CHO) and deuterated (NH 2 CDO and ND 2 CHO) formamide precursors are examined to gain insight into the photodissociation mechanism. Here, the theoretical investigation has characterized the main pathway leading to each of the HCN/HNC isomers from the precursor isotopologues. The theoretical branching ratio [HNC]/[HCN] = 2.1 for nascent photofragments agrees with the experiment. The effect of the postphotolysis HNC ↔ HCN isomerization on the [HNC]/[HCN] ratio is predicted. We report the experimental branching ratio [HNCO]: ([HNC] + [HCN]) = 12 ± 3 and propose that most of HNCO originates from dissociation on the S-1 electronic state of formamide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Timing reconstruction utilising multiple detection subsystems at the Short-Baseline Near Detector experiment

The Short-Baseline Near Detector (SBND) is the near detector of the Short-Baseline Neutrino Program, located only 110 m away from the Booster Neutrino Beam (BNB) target at Fermilab (Illinois, USA). SBND employs key detection technologies: a 112-ton Liquid Argon Time Projection Chamber for ionisation electrons, an advanced Photon Detection System (PDS) made up of photomultiplier tubes and X-ARAPUCAs for scintillation light, and a 4π coverage of Cosmic Ray Taggers (CRTs) for cosmic muons. This setup offers an exceptional energy, spatial and timing reconstruction of neutrino interactions. In this poster, we present ongoing timing reconstruction efforts of the PDS and CRTs, as well as combining complementary information across multiple detection subsystems to improve the timing resolution. This results in nanosecond level timing information that can be leveraged as an analysis tool, including the reconstruction of the BNB substructure to accept or reject signals detected in-between neutrino bunches as well as a timing-based discrimination for cosmic rejection.

Corallo, Annalea [INFN, Ferrara]

Fabrication of thin-walled tubes from alloy 602 CA using shear assisted processing and extrusion

Thin-walled tube is usually produced seamlessly via an expensive multi-step process or via welding of thin sheets but at reduced performance. To overcome the current process and performance inefficiencies, advanced manufacturing methods need to be investigated. In this investigation, shear assisted processing and extrusion (ShAPE) was used to fabricate thin-walled Inconel 602 tube in a single-step. Tubes measuring 0.83 m length with a 12 mm outer diameter and 1 mm wall thickness were fabricated with an average surface roughness, Ra of 1.6 µm and Rz of 15 µm. Tensile testing of tubes in the as-fabricated condition showed strength increases of 4-35% over current offerings while maintaining or improving elongation. Electron microscopy analysis revealed the recrystallized microstructure with refined inter- and intra-granular carbides. Preliminary results obtained in this investigation shows the feasibility of producing thin-wall high temperature tube in single-step via ShAPE. This achievement marks a significant step towards manufacturing larger diameter nickel alloy tubes for the U.S. Department of Energy’s Waste Treatment and Immobilization Plant.

36 MATERIALS SCIENCE

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING