Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON IONIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electron ionization via dark matter-electron scattering and the Migdal effect

There are currently several existing and proposed experiments designed to probe sub-GeV dark matter (DM) using electron ionization in various materials. The projected signal rates for these experiments assume that this ionization yield arises only from DM scattering directly off electron targets, ignoring secondary ionization contributions from DM scattering off nuclear targets. We investigate the validity of this assumption and show that if sub-GeV DM couples with comparable strength to both protons and electrons, as would be the case for a dark photon mediator, the ionization signal from atomic scattering via the Migdal effect scales with the atomic number Z and 3-momentum transfer q as Z 2 q 2 . The result is that the Migdal effect is always subdominant to electron scattering when the mediator is light, but that Migdal-induced ionization can dominate over electron scattering for heavy mediators and DM masses in the hundreds of MeV range. We put these two ionization processes on identical theoretical footing, address some theoretical uncertainties in the choice of atomic wave functions used to compute rates, and discuss the implications for DM scenarios where the Migdal process dominates, including for XENON10, XENON100, and the recent XENON1T results on light DM scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron ionization of clusters containing the formamide molecule

Abstract Studies on electron interactions with formamide (FA) clusters promote scientific interest as a model system to understand phenomena relevant to astrophysical, prebiotic, and radiobiological processes. In this work, mass spectrometric detection of cationic species for both small bare and microhydrated formamide clusters was performed at an electron ionization of 70 eV. Furthermore, a comparative analysis of the cluster spectra with the literature-reported gas-phase spectra is presented and discussed, revealing different reaction channels affected by the cluster environment. This study is essential in developing our understanding of both low-energy electron phenomena in clusters that can bridge the complexity gap between gas and realistic systems and the effect of hydration on electron-induced processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tolerance of Perovskite Solar Cells to Targeted Proton Irradiation and Electronic Ionization Induced Healing

Mixed organic–inorganic halide perovskite solar cells (PSCs) are of interest for space photovoltaic applications due to their apparent tolerance to high-energy proton radiation. Here, the use of a more stable wide-bandgap FA0.8Cs0.2PbI2.4Br0.6Cl0.02 perovskite with thin encapsulation enables, for the first time, the detailed dependence of fluence and energy of energetic protons on device performance. Energies were chosen to provide the highest concentration of displacements within the active region, and therefore the highest amount of degradation. Not only are these devices tolerant when compared to conventional technologies, but an unexpected increase in open circuit voltage and power density is observed for increased electronic ionization when the proton energy is increased. This study aims to expand the description of the proton radiation tolerance to include not only nonionizing nuclear energy losses that are most detrimental to current technologies, but electronic ionization, which is shown to yield benefits in PSCs.

device performance↗

Trocylation of 3-quinuclidinol, a key marker for the chemical warfare agent 3-quinuclidinyl benzilate, for its enhanced detection at low levels in complex soil matrices by electron ionization gas chromatography–mass spectrometry

Detection of 3-quinuclidinol (3Q), a marker for the chemical warfare agent 3-quinuclidinyl benzilate, is very difficult by gas chromatography–mass spectrometry (GC/MS), providing low, broad signals even when analyzed in isolated form. Therefore, a method that can convert 3Q into a substrate with enhanced detectability by GC/MS would be an important tool for its analysis. 2,2,2-Trichloroethoxycarbonyl chloride (TrocCl) was used in the derivatization of 3Q in three different soils of varying composition and total organic content (Virginia type A soil, Nebraska EPA standard soil and Ottawa sand) when present at a 10 μg g -1 concentration in each. A direct derivatization protocol and one involving the pre-extraction of the analyte were evaluated for their individual efficiencies and subsequent analysis using electron ionization GC/MS. The practical derivatization of 3Q, when present at low levels (10 μg g -1 ) in three different soil matrices, was found to be rapid (1 h) and to take place smoothly at ambient temperature (and as low as 4°C). The method detection limit was determined to be 30 ng mL -1 for the Virginia type A soil, 49 ng mL -1 for the Nebraska EPA standard soil and 72 ng mL -1 for the Ottawa sand sample. An expedient and practical derivatization method for 3Q, a chemical warfare degradation product difficult to detect by GC/MS, has been realized using trichloroethyl chloroformate. The reaction provides 3Q-Troc, a derivative with better detectability than 3Q by electron ionization GC/MS such as peak sharpness and a unique mass spectrum for its unambiguous identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Internal Fragments Generated by Electron Ionization Dissociation Enhance Protein Top-Down Mass Spectrometry

Top-down proteomics by mass spectrometry (MS) involves the mass measurement of an intact protein followed by subsequent activation of the protein to generate product ions. Electron-based fragmentation methods like electron capture dissociation and electron transfer dissociation are widely used for these types of analyses. Recently, electron ionization dissociation (EID), which utilizes higher energy electrons (>20 eV) has been suggested to be more efficient for top-down protein fragmentation compared to other electron-based dissociation methods. In this paper, we demonstrate that the use of EID enhances protein fragmentation and subsequent detection of protein fragments. Protein product ions can form by either single cleavage events, resulting in terminal fragments containing the C-terminus or N-terminus of the protein, or by multiple cleavage events to give rise to internal fragments that include neither the C-terminus nor the N-terminus of the protein. Conventionally, internal fragments have been disregarded, as reliable assignments of these fragments were limited. Here, we demonstrate that internal fragments generated by EID can account for ~20–40% of the mass spectral signals detected by top-down EID-MS experiments. By including internal fragments, the extent of the protein sequence that can be explained from a single tandem mass spectrum increases from ~50 to ~99% for 29 kDa carbonic anhydrase II and 8.6 kDa ubiquitin. When searching for internal fragments during data analysis, previously unassigned peaks can be readily and accurately assigned to confirm a given protein sequence and to enhance the utility of top-down protein sequencing experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Synthetic Opioids Belonging to the Fentanyl Class in Silt Using Electron Ionization Gas Chromatography-Mass Spectrometry (GC-MS).

An extraction protocol from silt sediment of fentanyl and three analogs: acetylfentanyl, thiofentanyl and acetylthiofentanyl, spiked at two concentrations each and separately (at ~1 and ~10 µg/g), is described. In addition, the identity of the fentanyls preliminarily identified by electron ionization gas chromatography-mass spectrometry (EI-GC-MS) analysis, can be corroborated by reacting each opioid in the silt’s extract with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl). Further, reaction between Troc-Cl and each opioid generates two unique products that can be used to retrospectively identify the original opioid therefore serving as a corroborating tool for known opioids as well as new, unknown fentanyl analogs.

60 APPLIED LIFE SCIENCES↗

Array-Based Machine Learning for Functional Group Detection in Electron Ionization Mass Spectrometry

Mass spectrometry is a ubiquitous technique capable of complex chemical analysis. The fragmentation patterns that appear in mass spectrometry are an excellent target for artificial intelligence methods to automate and expedite the analysis of data to identify targets such as functional groups. To develop this approach, we trained models on electron ionization (a reproducible hard fragmentation technique) mass spectra so that not only the final model accuracies but also the reasoning behind model assignments could be evaluated. The convolutional neural network (CNN) models were trained on 2D images of the spectra using transfer learning of Inception V3, and the logistic regression models were trained using array-based data and Scikit Learn implementation in Python. Our training dataset consisted of 21,166 mass spectra from the United States’ National Institute of Standards and Technology (NIST) Webbook. The data was used to train models to identify functional groups, both specific (e.g., amines, esters) and generalized classifications (aromatics, oxygen-containing functional groups, and nitrogen-containing functional groups). We found that the highest final accuracies on identifying new data were observed using logistic regression rather than transfer learning on CNN models. It was also determined that the mass range most beneficial for functional group analysis is 0–100 m/z. We also found success in correctly identifying functional groups of example molecules selected from both the NIST database and experimental data. Beyond functional group analysis, we also have developed a methodology to identify impactful fragments for the accurate detection of the models’ targets. The results demonstrate a potential pathway for analyzing and screening substantial amounts of mass spectral data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection and confirmation of fentanyls in high clay‐content soil by electron ionization gas chromatography‐mass spectrometry

Abstract Detection of illicit drugs in the environment, particularly in soils, often suggests the present or past location of a clandestine production center for these substances. Thus, development of efficient methods for the analysis and detection of these chemicals is of paramount importance in the field of chemical forensics. In this work, a method involving the extraction and retrospective confirmation of fentanyl, acetylfentanyl, thiofentanyl, and acetylthiofentanyl using trichloroethoxycarbonylation chemistry in a high clay‐content soil is presented. The soil was spiked separately with each fentanyl at two concentrations (1 and 10 μg/g) and their extraction accomplished using ethyl acetate and aqueous NH 4 OH (pH ~ 11.4) with extraction recoveries ranging from ~56% to 82% for the high‐concentration (10 μg/g) samples while ranging from ~68% to 83% for the low‐concentration (1 μg/g) samples. After their extraction, residues containing each fentanyl were reacted with 2,2,2‐trichloroethoxycarbonyl chloride (Troc‐Cl) to generate two unique and predictable products from each opioid that can be used to retrospectively confirm their presence and identity using EI‐GC‐MS. The method's limit of detection (MDL/LOD) for Troc‐norfentanyl and Troc‐noracetylfentanyl were estimated to be 29.4 and 31.8 ng/mL in the organic extracts. In addition, the method's limit of quantitation for Troc‐norfentanyl and Troc‐noracetylfentanyl were determined to be 88.2 and 95.5 ng/mL, respectively. Collectively, the results presented herein strengthen the use of chloroformate chemistry as an additional chemical tool to confirm the presence of these highly toxic and lethal substances in the environment.

Valdez, Carlos A.↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studying the SBND Cathode Structure

The Short-Baseline Near Detector (SBND) is a Liquid Argon Time Projection Chamber (LArTPC) located at Fermilab. It utilizes electrons ionized by passing particles inside the detector to create 3D reconstructions of interactions. This is achieved by drifting ionized electrons towards the instrumented wire planes. Structurally, the cathode can be mapped using cosmic ray muons by using information of their trajectories and their timing. This study shows that the cathode has rich structure. Though preliminary, this work shows evidence of non-negligible effects and warrants further investigation of these structures which could lead to improved detector simulations and more reliable event reconstructions.

Cataldo, Aedan [Notre Dame U.]↗

Electron-impact ionization of the Pb atom

Electron-impact ionization cross sections are calculated for the ground configuration of the Pb atom. Time-dependent close-coupling cross sections for the direct ionization of the 6 s and 6 p subshells leading to single ionization are calculated with and without a polarization potential. Configuration-average distorted-wave cross sections for the direct ionization of the 6 s and 6 p subshells leading to single ionization are also calculated with and without a polarization potential. We find the time-dependent close-coupling cross sections using a polarization potential to be in good agreement with convergent-close-coupling cross sections using a polarization potential. The total direct ionization cross sections are compared to two sets of experimental measurements. The differences between the direct ionization cross sections and the experimental measurements are mainly due to indirect ionization cross sections coming from the 6 s 2 6 p 2 → 6 s 6 p 3 excitation followed by autoionization..

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron impact ionization in dense plasmas

Here, the distorted-wave with exchange (DWE) method is employed to evaluate electron impact ionization cross sections in dense electron–ion plasmas. Bound and continuum electron wave functions are obtained from a non-relativistic average-atom code. Plots of DWE cross sections are presented for 1s electrons in Li and Be plasmas and 2p electrons in Na and Mg plasmas. For each of these elements, cross sections are evaluated at metallic density in a range of temperatures from 10 to 100 eV and at their respective melting points. Resonances in the cross sections appear near the incident energy threshold at high temperatures. The origin of these resonances is discussed. In general, the distorted wave (DW) method without exchange is found to be a good approximation to the DWE method for electron impact ionization calculations. In the resonance region, however, exchange effects are found to be very important and cannot be neglected.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of space charge effects in the MicroBooNE LArTPC using cosmic muons

Large liquid argon time projection chambers (LArTPCs), especially those operating near the surface, are susceptible to space charge effects. In the context of LArTPCs, the space charge effect is the build-up of slow-moving positive ions in the detector primarily due to ionization from cosmic rays, leading to a distortion of the electric field within the detector. This effect leads to a displacement in the reconstructed position of signal ionization electrons in LArTPC detectors ("spatial distortions"), as well as to variations in the amount of electron-ion recombination experienced by ionization throughout the volume of the TPC. We present techniques that can be used to measure and correct for space charge effects in large LArTPCs by making use of cosmic muons, including the use of track pairs to unambiguously pin down spatial distortions in three dimensions. Finally, the performance of these calibration techniques are studied using both Monte Carlo simulation and MicroBooNE data, utilizing a UV laser system as a means to estimate the systematic bias associated with the calibration methodology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulating Electron Impact Ionization using a General Particle Tracer (GPT) Custom Element

A new C++ custom element has been developed with the framework of General Particle Tracer (GPT) to simulate electron impact ionization of residual gas molecules. The custom element uses Monte-Carlo routines to determine both the ion production rate and the secondary electron kinetic energy based on user-defined gas densities and theoretical values for the ionization cross section and the secondary electron differential cross section. It then uses relativistic kinematics to track the secondary electron, the scattered electron, and the newly formed ion after ionization. The ion production rate and the secondary electron energy distribution determined by the custom element have been benchmarked against theoretical calculations and against simulations made using the simulation package IBSimu. While the custom element was originally built for particle accelerator simulations, it is readily extensible to other applications. The custom element will be described in detail and examples of applications at the Thomas Jefferson National Accelerator Facility will be presented for ion production in a DC high voltage photo-gun.

Yoskowitz, J. T.↗