Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ELECTRON GUN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High average current HVDC electron gun for EIC hadron cooling

A critical R&D initiative for the Electron Ion Collider (EIC) involves the design of an electron gun capable of gen erating a high average current and high-brightness electron beam for the hadron cooler. This is essential to preserve hadron beam quality and achieve the collider’s luminosity target of 1 × 10 34 s −1 cm −2 . For an energy recovery linac (ERL)-based hadron cooler, the gun must deliver a high average current of 98.5 mA, a normalized transverse emittance of less than 2 mm−mrad, and a bunch charge of up to 2.5 nC. This proceeding outlines the high-voltage design of a DC gun operating at 500 kV, with conditioning capability up to 600 kV. The design incorporates several unique fea tures, including the use of inverted ceramic at this voltage level, active cooling for the cathode, and large single-crystal multi-alkali cathodes grown on a silicon carbide substrate. High-brightness electron sources are also pivotal for other ad vanced applications, such as high-intensity gamma sources, future 𝑒 + 𝑒 − colliders, and ultra-deep UV sources for the semiconductor industry. Additionally, this paper provides an overview of the hadron cooling approaches planned or proposed for the EIC.

43 PARTICLE ACCELERATORS

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION

Delineation of the impact on temporal behaviors of off-axis photoemission in an ultrafast electron microscope

Efforts to push the spatiotemporal imaging-resolution limits of femtosecond laser-driven ultrafast electron microscopes (UEMs) to the combined angstrom–fs range will benefit from stable sources capable of generating high bunch charges. Recent demonstrations of unconventional off-axis photoemitting geometries are promising, but connections to the observed onset of structural dynamics are yet to be established. Here we use the in-situ photoexcitation of coherent phonons to quantify the relative time-of-flight (r-TOF) of photoelectron packets generated from the Ni Wehnelt aperture and from a Ta cathode set-back from the aperture plane. We further support the UEM experiments with particle-tracing simulations of the precise electron-gun architecture and photoemitting geometries. In this way, we measure discernible shifts in electron-packet TOF of tens of picoseconds for the two photoemitting surfaces. Furthermore, these shifts arise from the impact that the Wehnelt-aperture off-axis orientation has on the electron-momentum distribution, which modifies both the collection efficiency and the temporal-packet distribution relative to on-axis emission. Future needs are identified; we expect this and other developments in UEM electron-gun configuration to expand the range of material phenomena that can be directly imaged on scales commensurate with fundamental structural dynamics.

47 OTHER INSTRUMENTATION

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]

Optically Stimulated Luminescence Data Storage (Abstract)

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING

Towards advanced polarized electron sources

Polarized electrons play an important role in high-energy and nuclear physics, and their properties have also been exploited in ultrafast electron microscopy. Currently, gallium arsenide crystals illuminated by circular polarized infrared laser light are commonly used for generating polarized electrons. However, the achievable accelerating voltage and the gradient of these electrostatic sources limit the beam quality and quantity. A solution could be to combine gallium arsenide photocathodes with radio-frequency electron guns, which are capable of accelerating beams with significantly higher gradients and voltage. Here we report the successful operation of a gallium arsenide photocathode in a superconducting radio-frequency gun. Our findings are relevant for future sources of polarized electrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics

Stability and Viability of Off-Axis Photoemission Geometries in 4D Ultrafast Electron Microscopy

Femtosecond (fs) laser-based 4D ultrafast electron microscopy (UEM) commonly makes use of photoelectron emission from a source material in the electron gun region of an otherwise conventional TEM. For TEMs equipped with thermionic guns, the source material is often LaB 6 , the same as used for thermionic operation. Here, such thermionic-based UEMs have proven useful for applications requiring large electron fluxes (i.e., high beam currents) often at the expense of beam coherence and brightness, which is especially important for single-shot nanosecond applications. Importantly, for fs-based UEMs, beam currents can be controlled over a broad range of parameter space through the properties of the fs laser and the photon pulses produced therefrom.

Willis, Simon A. [University of Minnesota, Minneap

Beam results for the new super-conducting booster at Jefferson Lab

The performance results of a new super-conducting booster for the CEBAF injector at Jefferson Lab, could be of interest for other similar electron injectors. A recent addition of this new booster has provided us the ability to achieve a more adiabatic acceleration and therefore an improvement to the beam dynamics and beam brightness. It has also simplified the design and operation of the section of the injector responsible for accelerating the electron beam from a few hundred keV to several MeV (typically 6.7 MeV). The addition of the new booster was part of an upgrade to the CEBAF injector to improve the beam quality for future physics experiments with high sensitivity to beam quality. The booster consists of two cavities: a 2-cell cavity followed by a 7-cell cavity. This combination allows for a wide range of input electron beam energies, from 130 keV to more than 300 keV. In fact, during the last year, the booster was successfully operated with 140,180, and 200 keV input beam energies as the electron gun was being upgraded. This paper describes the new booster, presents beam optics data results from different beam studies, commissioning, and the physics quality beam operation.

Accelerator Physics

The Electron Spectro-Microscopy (ESM) Beamline at NSLS-II

Photoelectron spectroscopy is a primary tool for the study of the electronic structure of materials and the chemical composition of surfaces. High-resolution angle-resolved photoemission spectroscopy (ARPES) has the unique ability to map the energy bands in momentum space. Furthermore, going beyond the single particle picture, the self-energy corrections caused by correlations in solids can be extracted from the analysis of the emission line shape. The current level of refinement, in terms of energy and angular resolution (ΔE < 1 meV, Δθ < 0.1°), makes the technique sensitive to the lowest energy excitations and the dynamics of electrons, which in turn virtually determine all the macroscopic properties of any system and govern the chemical, electrical, magnetic, and physical processes. Similarly important, X-ray photoelectron microscopy (XPEEM), combined with the low-energy electron microscopy (LEEM), is indispensable in probing the complexity of chemical, structural, electronic and magnetic properties of surfaces and shallow interfaces, with the spatial resolution of few tens of nanometer (nm). The Electron-Spectro-Microscopy beamline (ESM) has been recently commissioned at NSLS-II and is now in operation. The primary spectroscopic technique is photoemission, performed over a wide energy range with control of light polarization and in a variety of flux/resolution conditions. The beamline has two experimental end stations that allow to perform ARPES and XPEEM/LEEM, separately. The ARPES end station focuses on high energy-resolution work, with spot-size of a few microns. The XPEEM/LEEM end station is a full-field microscope (XPEEM) operating either with the synchrotron generated X-rays (XPEEM), or with an internal electron gun (LEEM). Spatial resolution is crucial in studies of newly synthesized complex materials since they are often initially available only as small specimens (typically micron size). Furthermore, chemical inhomogeneities on surfaces are often an integral part of surface chemical processes. Finally, the ESM beamline with X-ray spots of few microns is optimized to study the electronic structure of novel materials with microscopy capabilities.

47 OTHER INSTRUMENTATION

Accelerators for the Future: R&D at the Fermilab FAST Facility

High energy physics in the U.S. has ambitious plans requiring new and improved accelerator technologies, including an upgraded complex at Fermilab for DUNE, next-generation light sources, and the potential of a future collider to be built on U.S. soil. To address these requirements, Fermilab operates the Fermilab Accelerator Science and Technology (FAST) facility, dedicated to accelerator R&D. FAST includes an electron gun and superconducting RF linac (up to 300 MeV), a storage ring, and an upcoming proton source and injector line (up to 2.5 MeV). In addition to the future of Fermilab accelerators, the broad physics program includes general R&D with potential impact across the DOE science program. This colloquium will provide a basic introduction to accelerator technologies and describe the principles of proton and electron accelerators, including the challenges associated with next-generation operations. We will discuss the exciting R&D ongoing at FAST to address the required technological advancements, focusing on Non-Linear Integrable Optics (NIO) for improved beam intensity and Optical Stochastic Cooling (OSC) for improved beam quality, and touching on a wide range of additional ongoing research. I intend to make the content interesting and accessible to those who have never taken any formal courses in accelerator physics.

43 PARTICLE ACCELERATORS

Novel Concepts for High Gradient Acceleration (Final Technical Report)

We have conducted an intensive, pioneering program to demonstrate novel concepts for achieving high gradient acceleration at frequencies from the conventional microwave bands up to the millimeter wave /THz bands. High gradient accelerators hold the promise of smaller and less costly accelerators for applications ranging from the largest scale accelerators used for discovery science down to the smallest accelerators used for industrial, homeland security and medical applications. The research consisted of two major research thrusts: 1.) Structure-based wakefield accelerator (SWFA) research in collaboration with the Argonne Wakefield Accelerator research group and 2.) Millimeter Wave / THz high gradient acceleration in collaboration with SLAC. The specific goals of the research program were: Design novel metallic metamaterial structures that increase the beam-wave coupling for the accelerator mode and reduce the effect of high order modes; test novel metamaterial structures to achieve higher output power, > 1 GW at X-Band (11.7 GHz), in test at the Argonne Wakefield Accelerator (AWA); determine the experimental breakdown threshold for nanosecond-scale pulses at X-Band in testing at the AWA; test a 110 GHz accelerator structure with a field emission electron gun, built at SLAC, using pulses from a 1 MW, 110 GHz gyrotron; design, build and test a 110 GHz quasi-optical, resonant-ring pulse compressor to compress microsecond pulses from the 1 MW gyrotron into > 20 MW, 5 ns output pulses for accelerator structure testing. The proposed research program built on our successes in our research program including: Generation of 510 MW, 2.1 ns (FWHM) pulses at 11.7 GHz from a metallic metamaterial structure in test at the Argonne Wakefield Accelerator using a train of eight 65 MeV electron bunches spaced at 1.3 GHz with a total charge of 280 nC. The metamaterial structure consisted of 100 copper unit cells each consisting of a “wagon-wheel” plate and a spacer plate with a total structure length of 0.2 m. The 510 MW pulse generated an on-axis wakefield of 130 MV/m that could be used to accelerate a trailing witness bunch. Demonstration of coupling of an unprecedented rf power level of 575kW into a 110 GHz accelerator structure using a quasi-optical setup. The standing structure consisted of a central copper cavity located between two matching cavities fed by a TM01 mode. The 6 ns input pulses were sliced from 3 microsecond pulses from the gyrotron using a laser-driven silicon switch. We obtained an unprecedented high gradient up to 230MV/m corresponding to a peak surface electric field of more than 520 MV/m.

43 PARTICLE ACCELERATORS

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS

Space Charge Effects on Spin Polarization in High-Intensity Preinjector

This analytical study investigates the space charge impact on electron beam polarization within the low-energy range, spanning from the polarized electron gun up to the linac. The research study three sections: the gun-to-Wien filter interface, the Wien filter section, and the bunching section. We will comprehensively assess polarization degradation mechanisms in each region characterized by space charge effects. We are planning to simulate the spin tracking through the entire low-energy transmission system using Generalized Particle Tracer (GPT) to validate our analytical findings and includes the higher order components.

43 PARTICLE ACCELERATORS

Accuracy and Resolution Evaluation of the E-Beam Profile Scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges. For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a phosphor screen and an optical transition radiation (OTR) screen. The capabilities of the Kimball Physics electron gun (eGun) will be considered for accuracy. Additionally, the Zemax software will be utilized to characterize the optical elements.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057

Recent developments and operation of polarized photocathodes at Jefferson Lab

Spin-polarized electron sources are critical to a wide range of accelerator-based applications for nuclear and particle physics. At Thomas Jefferson National Accelerator Facility, they play a central role in delivering high-quality polarized beams for precision nuclear physics experiments and next-generation parity-violation measurements, where stringent control of systematic uncertainties is essential. These sources are also expected to be key components of other initiatives, including the Electron-Ion Collider and the potential future positron capabilities at Jefferson Lab. In this talk, I will present ongoing research and development efforts at Jefferson Lab focused on the design, fabrication and optimization of spin-polarized photocathodes. This includes growth using molecular beam epitaxy (MBE) or metal-organic chemical vapor deposition (MOCVD), along with detailed characterization of their performance metrics, such as quantum efficiency (QE), electron spin polarization and QE anisotropy, all of which are increasingly important metrics for polarized electron sources at Jefferson Lab and the Electron-Ion Collider. Strategies to mitigate QE anisotropy, which is critical for reducing helicity-correlated beam asymmetries in precision experiments such as MOLLER will be highlighted. Finally, I will present recent efforts aimed at improving the operational lifetime of spin-polarized photocathodes in injector environments, particularly under high-voltage conditions in DC electron guns. These developments are essential for enabling reliable, high-performance operation of polarized sources for current and future accelerator programs.

Kachwala, Alimohammed [Thomas Jefferson National A

Electron-induced chemical transformation of vapor-phase synthesized hybrid resist materials for EUV and beyond EUV lithography

Here, in this study, we utilize an in situ Fourier transform infrared (FTIR) spectroscopy chamber equipped with an electron flood gun to comprehensively investigate the electron-induced chemical transformations in advanced inorganic–organic hybrid resist thin films. The characteristics of the electron gun were assessed, showing a detectable current decrease with increasing Faraday cup bias voltage, confirming that the electron energies impacting the sample were within the expected range. This unique FTIR system was applied to study two hybrid resist thin-film systems, Al–HQ and Zn–HQ, both exhibiting saturation growth characteristics at 150 °C. Results revealed that Al–HQ demonstrated superior electron sensitivity compared to Zn–HQ at energies ≤ 100 eV. Chemical changes observed were consistent with previous findings, underscoring the potential of this methodology to elucidate exposure mechanisms. This research contributes to the fundamental understanding necessary for the development of advanced resist materials for the next-generation nanolithography applications.

36 MATERIALS SCIENCE

Measurement of the Cathode Recess

The 113 MHz SRF gun for the coherent electron cooling is designed with adjustable position of the cathode vs. the nose piece of the quarter wave gun as it is shown in Fig. 1. By changing the cathode position we modify the profile of the accelerating field. By retracting the cathode, we reduce the surface field but increase the focusing component as it shown in Fig. 2. The optimal position is defined by the beam dynamics and is found based on simulations.

43 PARTICLE ACCELERATORS