Multi-channel electronically scanned cryogenic pressure sensor

A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multielement array. These dies are bonded at specific sites on a glass, prepatterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

Chapman, John J.↗

Use of open-structure channel electron multipliers in sounding rocket experiments.

The performance of open-structure channel electron multipliers has been investigated in a laboratory simulation of the ascent pressure profile for a typical sounding rocket. The results of this test demonstrate that evacuation of the payload prior to launch is necessary for experiments where stability of response is an essential parameter.

Timothy, J. G.↗

Cleaning of contaminated channel electron multiplier arrays.

Polymerized organic materials found in vacuum systems frequently contaminate the individual channels (which can be as small as 15 microns) of an oil-pumped channel electron multiplier array used as a vacuum UV- to visible-radiation conversion device. It is shown that exposure to an oxygen plasma is an effective means of decontaminating the channels, thereby restoring the sensitivity of the device.

Harlow, F. E.↗

Quantum efficiency of a channel electron multiplier in the far ultraviolet

Variation of the quantum efficiency of a channel electron multiplier (CEM) in the wavelength range from 1200 to 2536 A is studied. Emphasis is on measurement of CEM sensitivity longward of 1500 A. Results indicate an overall rapid decrease in quantum efficiency with increasing wavelength, with little evidence for a possible change in slope in the range from 2000 to 2500 A. The lowest efficiency measured is 4.5 + or -2.5 times 10 to the minus ninth count/photon at 2536 A. These efficiencies should ensure that unwanted radiation longward of 1500 A can be effectively removed from the bandpass of the instrument.

Paresce, F.↗

Multi-Channel Electronically Scanned Cryogenic Pressure Sensor And Method For Making Same

A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multi-element array. These dies are bonded at specific sites on a glass, pre-patterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

Chapman, John J.↗

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.↗

Mass-dependent channel electron multiplier operation

The absolute counting efficiency and pulse height distributions of a continuous-channel electron multiplier used in the detection of hydrogen, argon and xenon ions are assessed. The assessment technique, which involves the post-acceleration of 8-eV ion beams to energies from 100 to 4000 eV, provides information on counting efficiency versus post-acceleration voltage characteristics over a wide range of ion mass. The charge pulse height distributions for H2 (+), A (+) and Xe (+) were measured by operating the experimental apparatus in a marginally gain-saturated mode. It was found that gain saturation occurs at lower channel multiplier operating voltages for light ions such as H2 (+) than for the heavier ions A (+) and Xe (+), suggesting that the technique may be used to discriminate between these two classes of ions in electrostatic analyzers.

Fields, S. A.↗