SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over 30 patients with pacemakers without complications, including 3 cardiac MR exams.

60 APPLIED LIFE SCIENCES↗

Relationships between electrical and mechanical dyssynchrony in patients with left bundle branch block and healthy controls

Background: Abnormal electrical activation may cause dyssynchronous left ventricular (LV) contraction. In this study, we characterized and analyzed electrical and mechanical dyssynchrony in patient with left bundle branch block (LBBB) and healthy controls. Methods: Myocardial perfusion imaging (MPI) data from 994 patients were analyzed. Forty-three patient fulfilled criteria for LBBB and 24 for controls. Electrical activation was characterized with vector electrocardiography (VECG) and LV function including mechanical dyssynchrony with ECG-gated MPI phase analysis. Results: QRS duration (QRSd; r = 0.69, P < .001) and a few other VECG parameters correlated significantly with phase bandwidth (phaseBW) representing mechanical dyssynchrony. End-diastolic volume (EDV; r = 0.59, P < .001), ejection fraction and end-systolic volume correlated also with phaseBW. QRSd (β = 0.47, P < .001) and EDV (β = 0.36, P = .001) were independently associated with phaseBW explaining 55% of its variation. Sixty percent of patients with LBBB had significant mechanical dyssynchrony. Those patients had wider QRSd (159 vs 147 ms, P = .013) and larger EDV (144 vs 94 mL, P = .008) than those with synchronous LV contraction. Cut-off values for mechanical dyssynchrony seen in patients with LBBB were QRSd ≥ 165 ms and EDV ≥ 109 mL. Conclusions: Despite obvious conduction abnormality, LBBB is not always accompanied by mechanical dyssynchrony. QRSd and EDV explained 55% of variation seen in phaseBW. These two parameters were statistically different between LBBB cases with and without mechanical dyssynchrony.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The human skin as a sub-THz receiver – Does 5G pose a danger to it or not?

Highlights: • The sweat duct is regarded as a helical antenna in the sub-THz band, reflectance depends on perspiration. • We outline the background for non-thermal effects based on the structure of sweat ducts. • We have introduced a realistic skin EM model and found the expected SAR for the 5G standard. In the interaction of microwave radiation and human beings, the skin is traditionally considered as just an absorbing sponge stratum filled with water. In previous works, we showed that this view is flawed when we demonstrated that the coiled portion of the sweat duct in upper skin layer is regarded as a helical antenna in the sub-THz band. Experimentally we showed that the reflectance of the human skin in the sub-THz region depends on the intensity of perspiration, i.e. sweat duct's conductivity, and correlates with levels of human stress (physical, mental and emotional). Later on, we detected circular dichroism in the reflectance from the skin, a signature of the axial mode of a helical antenna. The full ramifications of what these findings represent in the human condition are still unclear. We also revealed correlation of electrocardiography (ECG) parameters to the sub-THz reflection coefficient of human skin. In a recent work, we developed a unique simulation tool of human skin, taking into account the skin multi-layer structure together with the helical segment of the sweat duct embedded in it. The presence of the sweat duct led to a high specific absorption rate (SAR) of the skin in extremely high frequency band. In this paper, we summarize the physical evidence for this phenomenon and consider its implication for the future exploitation of the electromagnetic spectrum by wireless communication. Starting from July 2016 the US Federal Communications Commission (FCC) has adopted new rules for wireless broadband operations above 24 GHz (5 G). This trend of exploitation is predicted to expand to higher frequencies in the sub-THz region. One must consider the implications of human immersion in the electromagnetic noise, caused by devices working at the very same frequencies as those, to which the sweat duct (as a helical antenna) is most attuned. We are raising a warning flag against the unrestricted use of sub-THz technologies for communication, before the possible consequences for public health are explored.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

An implantable instrument for studying the long-term flight biology of migratory birds

The design of an instrument deployed in a project studying the high altitude Himalayan migrations of bar-headed geese (Anser indicus) is described. The electronics of this archival datalogger measured 22 × 14 × 6.5 mm, weighed 3 g, was powered by a ½AA-sized battery weighing 10 g and housed in a transparent biocompatible tube sealed with titanium electrodes for electrocardiography (ECG). The combined weight of 32 g represented less than 2% of the typical bodyweight of the geese. The primary tasks of the instrument were to continuously record a digitised ECG signal for heart-rate determination and store 12-bit triaxial accelerations sampled at 100 Hz with 15% coverage over each 2 min period. Measurement of atmospheric pressure provided an indication of altitude and rate of ascent or descent during flight. Geomagnetic field readings allowed for latitude estimation. These parameters were logged twice per minute along with body temperature. Data were stored to a memory card of 8 GB capacity. Instruments were implanted in geese captured on Mongolian lakes during the breeding season when the birds are temporarily flightless due to moulting. The goal was to collect data over a ten month period, covering both southward and northward migrations. This imposed extreme constraints on the design's power consumption. Raw ECG can be post-processed to obtain heart-rate, allowing improved rejection of signal interference due to strenuous activity of locomotory muscles during flight. Accelerometry can be used to monitor wing-beat frequency and body kinematics, and since the geese continued to flap their wings continuously even during rather steep descents, act as a proxy for biomechanical power. The instrument enables detailed investigation of the challenges faced by the geese during these arduous migrations which typically involve flying at extreme altitudes through cold, low density air where oxygen availability is significantly reduced compared to sea level.

60 APPLIED LIFE SCIENCES↗

Can nontriggered thoracic CT be used for coronary artery calcium scoring? A phantom study

Purpose: Coronary artery calcium score, traditionally based on electrocardiography (ECG)-triggered computed tomography (CT), predicts cardiovascular risk. However, nontriggered CT is extensively utilized. The study-purpose is to evaluate the in vitro agreement in coronary calcium score between nontriggered thoracic CT and ECG-triggered cardiac CT.Methods: Three artificial coronary arteries containing calcifications of different densities (high, medium, and low), and sizes (large, medium, and small), were studied in a moving cardiac phantom. Two 64-detector CT systems were used. The phantom moved at 0–90 mm/s in nontriggered low-dose CT as index test, and at 0–30 mm/s in ECG-triggered CT as reference. Differences in calcium scores between nontriggered and ECG-triggered CT were analyzed by t-test and 95% confidence interval. The sensitivity to detect calcification was calculated as the percentage of positive calcium scores.Results: Overall, calcium scores in nontriggered CT were not significantly different to those in ECG-triggered CT (p > 0.05). Calcium scores in nontriggered CT were within the 95% confidence interval of calcium scores in ECG-triggered CT, except predominantly at higher velocities (≥50 mm/s) for the high-density and large-size calcifications. The sensitivity for a nonzero calcium score was 100% for large calcifications, but 46%± 11% for small calcifications in nontriggered CT.Conclusions: When performing multiple measurements, good agreement in positive calcium scores is found between nontriggered thoracic and ECG-triggered cardiac CT. Agreement decreases with increasing coronary velocity. From this phantom study, it can be concluded that a high calcium score can be detected by nontriggered CT, and thus, that nontriggered CT likely can identify individuals at high risk of cardiovascular disease. On the other hand, a zero calcium score in nontriggered CT does not reliably exclude coronary calcification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Workload Response to Soft Controls Presented on Two Interfaces - 382

Most operational Nuclear Power Plants (NPP) in the United States are primarily outfitted with physical (analog) Instruments and Controls (I and C). However, as parts wear out in legacy plants, these I and Cs are being replaced by digital interfaces. Furthermore, new plants are being proposed and built domestically and throughout the world that are composed primarily of soft controls in the main control room. To that end, it is important to understand if and how various types of interfaces affect performance. The present effort sought to compare a desktop and touchscreen interface. The Instantaneous Self-Assessment, the NASA-Task Load Index, and electrocardiography were used to assess workload response while performing three main control room task types on each interface. Results have implications for interface selection and assessment of new NPP main control room designs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transfer Learning-Based Independent Component Analysis

Understanding the underlying component structure is crucial for multivariate signal analysis. Among all the techniques that try to learn the latent structure, independent component analysis (ICA) is one of the most important and popular methods, which aims to extract independent components from multivariate signals and enables further analysis. For example, in electroencephalogram (EEG) analysis, artifacts filtering and disease detection are conducted based on the independent components of the signals. One critical challenge in existing ICA approaches is that the component extraction accuracy may degrade when the available data of a unit are limited. To address this issue, this paper proposes a transfer learning-based ICA method by innovatively transferring component distribution from a source domain, so that accurate component extraction results can be achieved even when only limited data are available in the target domain. To the best of our knowledge, this is the first work that leverages transfer learning to improve ICA accuracy with limited available data. In particular, we first extract all the independent components from the source domain by maximizing the log-likelihood function with a Newton-like method on a smooth manifold. Then for the target domain, the component with the largest negentropy is extracted in each round. To effectively leverage the knowledge from the source domain and to prevent the negative transfer, we try to find a component in the source domain that matches the component we are extracting. The probability density function of the matched component will then be used to improve the component extraction accuracy if such matched component can be found; otherwise, no knowledge will be transferred. Finally, numerical simulations and a case study with electrocardiogram (ECG) data are conducted, showing the effectiveness of the proposed method in transferring knowledge and reducing negative transfer.

42 ENGINEERING↗

SigTime: Learning and Visually Explaining Time Series Signatures

Understanding and distinguishing temporal patterns in time series data is essential for scientific discovery and decision-making. For example, in biomedical research, uncovering meaningful patterns in physiological signals can improve diagnosis, risk assessment, and patient outcomes. However, existing methods for time series pattern discovery face major challenges, including high computational complexity, limited interpretability, and difficulty in capturing meaningful temporal structures. Here, to address these gaps, we introduce a novel learning framework that jointly trains two Transformer models using complementary time series representations: shapelet-based representations to capture localized temporal structures and traditional feature engineering to encode statistical properties. The learned shapelets serve as interpretable signatures that differentiate time series across classification labels. Additionally, we develop a visual analytics system—SigTime—with coordinated views to facilitate exploration of time series signatures from multiple perspectives, aiding in useful insights generation. We quantitatively evaluate our learning framework on eight publicly available datasets and one proprietary clinical dataset. Additionally, we demonstrate the effectiveness of our system through two usage scenarios along with the domain experts: one involving public ECG data and the other focused on preterm labor analysis.

97 MATHEMATICS AND COMPUTING↗

A prospective study of the incidence of myocarditis/pericarditis and new onset cardiac symptoms following smallpox and influenza vaccination

Although myocarditis/pericarditis (MP) has been identified as an adverse event following smallpox vaccine (SPX), the prospective incidence of this reaction and new onset cardiac symptoms, including possible subclinical injury, has not been prospectively defined. The study's primary objective was to determine the prospective incidence of new onset cardiac symptoms, clinical and possible subclinical MP in temporal association with immunization. New onset cardiac symptoms, clinical MP and cardiac specific troponin T (cTnT) elevations following SPX (above individual baseline values) were measured in a multi-center prospective, active surveillance cohort study of healthy subjects receiving either smallpox vaccine or trivalent influenza vaccine (TIV). Results New onset chest pain, dyspnea, and/or palpitations occurred in 10.6% of SPX-vaccinees and 2.6% of TIV-vaccinees within 30 days of immunization (relative risk (RR) 4.0, 95% CI: 1.7-9.3). Among the 1081 SPX-vaccinees with complete follow-up, 4 Caucasian males were diagnosed with probable myocarditis and 1 female with suspected pericarditis. This indicates a post-SPX incidence rate more than 200-times higher than the pre-SPX background population surveillance rate of myocarditis/pericarditis (RR 214, 95% CI 65-558). Additionally, 31 SPX-vaccinees without specific cardiac symptoms were found to have over 2-fold increases in cTnT (>99th percentile) from baseline (pre-SPX) during the window of risk for clinical myocarditis/pericarditis and meeting a proposed case definition for possible subclinical myocarditis. This rate is 60-times higher than the incidence rate of overt clinical cases. No clinical or possible subclinical myocarditis cases were identified in the TIV-vaccinated group. In conclusion, passive surveillance significantly underestimates the true incidence of myocarditis/pericarditis after smallpox immunization. Evidence of subclinical transient cardiac muscle injury post-vaccinia immunization is a finding that requires further study to include long-term outcomes surveillance. Active safety surveillance is needed to identify adverse events that are not well understood or previously recognized.

59 BASIC BIOLOGICAL SCIENCES↗

Electrocardiographic Biomarkers for Detection of Drug-Induced Late Sodium Current Block

Drugs that prolong the heart rate corrected QT interval (QTc) on the electrocardiogram (ECG) by blocking the hERG potassium channel and also block inward currents (late sodium or L-type calcium) are not associated with torsade de pointes (e.g. ranolazine and verapamil). Furthermore, identifying ECG signs of late sodium current block could aid in the determination of proarrhythmic risk for new drugs. A new cardiac safety paradigm for drug development (the "CiPA" initiative) will involve the preclinical assessment of multiple human cardiac ion channels and ECG biomarkers are needed to determine if there are unexpected ion channel effects in humans.

60 APPLIED LIFE SCIENCES↗

Comparison of heart rate obtained from shorter duration Holter recordings to 24-hour mean heart rate in dogs with atrial fibrillation

The objective of this study was to evaluate the accuracy of short duration electrocardiographic (ECG) recordings extracted from ambulatory continuous ECG (Holter) to assess 24-hour mean heart rate in dogs with atrial fibrillation. In this retrospective study, Holter recordings obtained from 20 dogs with atrial fibrillation were selected for analysis. Ten out of 20 dogs were receiving drugs to control heart rate at the time of Holter evaluation. From the Holter recordings, heart rate averages were calculated for various sample durations (fiveminutes, 30 minutes, one-hour, two-hours, and three-hours) for each dog. Percentage of these shorter duration ECG obtained HR averages that fell within ±10%, ±15% and ± 20% of 24-hour mean heart rate was determined for each sample duration and for each dog. Seventy five percent of heart rate averages obtained from three-hour ECG recordings fell within ±10% of 24-hour mean HR. All the heart rate averages obtained from two-hour ECG recordings fell within ±20% of 24-hour mean heart rate. Based on the results of this study it can be concluded that the duration of the ECG recording affects the prediction accuracy for 24-hour Holter mean HR. Only two and three hours of Holter recordings provided all heart rate averages within ±20% of 24-hour mean heart rate. No significant differences were noted in the prediction accuracy of shorter duration ECG recordings based on rate control therapy status. Further prospective studies are needed to assess the accuracy of HR obtained at home using various ECG recording devices to predict 24-hour mean heart rate in dogs with atrial fibrillation.

59 BASIC BIOLOGICAL SCIENCES↗

Intracardiac Electrical Imaging using the 12-lead ECG: A Machine Learning Approach using Synthetic Data

Current state-of-the-art techniques for non-invasive imaging of cardiac electrical phenomena require voltage recordings from dozens of different torso locations and anatomical models built from expensive medical diagnostic imaging procedures. Here this study aimed to assess if recent machine learning advances could alternatively reconstruct electroanatomical maps at clinically relevant resolutions using only the standard 12-lead electrocardiogram (ECG) as input. To that end, a computational study was conducted to generate a dataset of over 16000 detailed cardiac simulations, which was then used to train neural network (NN) architectures designed to exploit both spatial and temporal correlations in the ECG signal. Analysis over a validation set showed average errors in activation map reconstruction below 1.7 msec over 75 intracardiac locations. Furthermore, phenotypical patterns of activation and the morphology of the activation potential were correctly reconstructed. The approach offers opportunities to stratify patients non-invasively, both retrospectively and prospectively, using metrics otherwise only available through invasive clinical procedures.

59 BASIC BIOLOGICAL SCIENCES↗

Feature Selection Techniques for a Machine Learning Model to Detect Autonomic Dysreflexia

Feature selection plays a crucial role in the development of machine learning algorithms. Understanding the impact of the features on a model, and their physiological relevance can improve the performance. This is particularly helpful in the healthcare domain wherein disease states need to be identified with relatively small quantities of data. Autonomic Dysreflexia (AD) is one such example, wherein mismanagement of this neurological condition could lead to severe consequences for individuals with spinal cord injuries. We explore different methods of feature selection needed to improve the performance of a machine learning model in the detection of the onset of AD. We present different techniques used as well as the ideal metrics using a dataset of thirty-six features extracted from electrocardiograms, skin nerve activity, blood pressure and temperature. The best performing algorithm was a 5-layer neural network with five relevant features, which resulted in 93.4% accuracy in the detection of AD. The techniques in this paper can be applied to a myriad of healthcare datasets allowing forays into deeper exploration and improved machine learning model development. Through critical feature selection, it is possible to design better machine learning algorithms for detection of niche disease states using smaller datasets.

electrocardiography↗