A comparative analysis of available clinical EKG telemetry systems was conducted. Although present day electrocardiogram diagnosis requires a high degree of measurement accuracy, there exists wide variations in the performance characteristics of the various telemeters marketed today necessitating careful consideration of specifications prior to procurement. The authors have endeavored to provide the physicians with a clear understanding, in terms of the effects on the electrocardiogram, of the factors he must evaluate in order to ensure high fidelity EKG reproduction. A tabulation of comparative parameter values for each unit obtained from manufacturers' specifications and substantiated by standardized performance tests conducted in our laboratory is presented.

Firstenberg, A.

Electrocardiogram preprocessing unit.

Analog circuit for presenting fixed pulse output corresponding to each cardiac cycle of given electrocardiogram and highly unresponsive to noise interference

ELECTROCARDIOGRAM

Direct reading of electrocardiograms and respiration rates

Technique for reading heart and respiration rates is more accurate and direct than the previous method. Index of a plastic calibrated card is aligned with a point on the electrocardiogram. Complexes are counted as indicated on the card and heart or respiration rate is read directly from the appropriate scale.

Wise, J. P.

Contourograph display system for monitoring electrocardiograms

Electrocardiogram is displayed as a contourogram on the cathode ray tube of a variable-persistence oscilloscope. Each cycle is stacked below its predecessors giving a three dimensional effect. A major change in the signal is apparent as a change in the contourogram pattern.

Golden, D. P., Jr.

The development of insulated electrocardiogram electrodes

An integrated system was developed, consisting of an insulated electrode and an impedance transformer, which can be used for the acquisition of electrocardiographic data. The electrode consists of a thin layer of dielectric material deposited onto a silicon substrate. The impedance transformer is an operational amplifier used in the unity gain configuration. Both electrode and impedance transformer are contained in a plastic housing identical to that used with the NASA Apollo-type electrode. The lower cut off frequency of the electrode system is between 0.01 and 1.0 Hz, depending on the dielectric used and its thickness. Clinical quality electrocardiograms were obtained with these electrodes.

Portnoy, W. M.

Electrocardiogram signal analyzer

Algorithm based on Taylor series expansion of Fourier transform has been developed and used for detection of cardiac arrhythmias in real-time electrocardiogram signal.

Portnoy, W. M.

Simultaneous image reproduction on CRT screen: Moves ultrasonic sectional view and electrocardiogram curves

A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.

Source record

A new technique for simultaneous monitoring of electrocardiogram and walking cadence

A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary

High-frequency Electrocardiogram Analysis in the Ability to Predict Reversible Perfusion Defects during Adenosine Myocardial Perfusion Imaging

Background: A previous study has shown that analysis of high-frequency QRS components (HF-QRS) is highly sensitive and reasonably specific for detecting reversible perfusion defects on myocardial perfusion imaging (MPI) scans during adenosine. The purpose of the present study was to try to reproduce those findings. Methods: 12-lead high-resolution electrocardiogram recordings were obtained from 100 patients before (baseline) and during adenosine Tc-99m-tetrofosmin MPI tests. HF-QRS were analyzed regarding morphology and changes in root mean square (RMS) voltages from before the adenosine infusion to peak infusion. Results: The best area under the curve (AUC) was found in supine patients (AUC=0.736) in a combination of morphology and RMS changes. None of the measurements, however, were statistically better than tossing a coin (AUC=0.5). Conclusion: Analysis of HF-QRS was not significantly better than tossing a coin for determining reversible perfusion defects on MPI scans.

Tragardh, Elin

Device and Method for Digital-To-Analog Transformations and Reconstructions of Multi-Channel Electrocardiograms

The present invention includes a method and apparatus for digital to analog conversion and reconstruction of multichannel electrocardiograms. The method may include receiving digital information representative of a plurality of independent signals, producing a plurality of analog outputs from said digital information wherein a first analog output is designated as a common reference, and imposing a predetermined voltage on a second analog output with respect to said common reference, which provides for a substantial recreation of the original independent signals. The apparatus may comprise a processor operable for receiving digital information representative of independent lead signals from a first ECG machine and digital to analog circuitry for substantially reproducing the original lead signals for analysis on a second ECG machine for convenient and efficient second opinions of cardiac data.