Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRIC CONDUCTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Single-Step Shear-Based Deformation Processing of Electrical Conductor Wires

Commercial electrical conductor wires are currently produced from aluminum alloys by multi-step deformation processing involving rolling and drawing. These processes typically require 10 to 20 steps of deformation, since the plastic strain or reduction that can be imposed in a single step is limited by material workability and process mechanics. Here, we demonstrate a fundamentally different, single-step approach to produce flat wire aluminum products using machining-based deformation that also ensures adequate material workability in the formed product. Two process routes are proposed: (1) chip formation by free-machining (FM), with a post-machining, light drawing reduction (<20%) to achieve desired finish and (2) constrained chip formation by large strain extrusion machining (LSEM). Using commercially pure aluminum conductor alloys (Al 1100 and EC1350) as representative material systems, we demonstrate key features of the machining-based processing, including (a) single-step processing to achieve flat wire geometries, (b) surface finish (Ra = 0.2 to 1.0 μm) comparable to that of commercial wire products made by drawing/rolling, (c) deformation control independent of wire size, and (d) hardness increases of 50–150% over that of annealed wires, while retaining high electrical conductivity (>56% IACS). Here, the wire microstructure, which can also be varied via the large-strain deformation parameters, is correlated with mechanical and electrical properties. Implications for commercial manufacture of flat wire products are discussed.

36 MATERIALS SCIENCE↗

Platinum nanometal interconnection of copper–carbon nanotube hybrid electrical conductors

This study demonstrates the versatility of Joule heating driven chemical vapor deposition to deposit nanometal interconnections into porous CNT roving with application in the production of high electrical conductivity copper-carbon nanotube (Cu-CNT) hybrids. Modifications of vapor deposition parameters allow for deposited nanometal masses from less than 5% w/w to over 85% w/w and distributions that can be controlled towards either hot-spot site-specificity or overall uniformity. Here, depositions of copper, platinum, nickel, palladium, ruthenium, rhodium, and iridium are demonstrated from acetylacetonate precursors. In particular, platinum acetylacetonate [Pt(acac) 2 ] deposits nanometal seeds that adhere tightly to the CNT roving, producing improvements in resistance and specific conductivity. The properties of the platinum deposition compared to the copper deposition motivate an investigation into its use as an interfacial layer for Cu-CNT hybrids. CNT conductors with ~30% w/w platinum are electroplated with copper, densified, and annealed to produce Cu-CNT hybrid conductors with specific conductivities as high as 5772 S m 2 /kg and TCR (from 300 to 600 K) as low as 3.12 × 10 –3 K –1 , indicating good interconnection of the metal and CNT portions. Room temperature conductivities of 29.8 MS/m are achieved, comparable to metallic conductors. Thus, Pt(acac) 2 seeded Cu-CNT hybrids offer abundant promise in high conductivity applications.

42 ENGINEERING↗

Eddy Current Model of a Coil Over An Infinite Perfectly Electrical Conductor (PEC) Half-Plane

Eddy current sensors measure the lift-off or distance between the sensor and a conducting surface. They operate on the principle of an alternating current in a conduction coil inducing a magnetic field within the surface. An eddy current is set up in the surface to counter the incident magnetic field which, in turn, sets up a magnetic field which counters that of the coil. This changes the coil impedance which is a function of the lift-off. As the lift-off increases, the effect of the eddy current magnetic field on the coil magnetic field weakens, resulting in a higher inductance and lower resistance. Thus, the lift-off may be derived from an impedance measurement. Dodd and Deeds developed an analytic model for an eddy current sensor coil impedance with an air core which has been implemented in MATLAB. LLNL assembled an eddy current sensor with a mu-metal core for which there is no analytic model. Rather than derive an analytic model which includes the mu-metal core, analytic empirically based functions are derived to map the Dodd and Deeds model to measured inductance and resistance.

42 ENGINEERING↗

Electrical conductor insulation system and method of fabrication

An insulation system includes a number of mica hard-boards joinable to form a free-standing slot-liner for insulating a conductor when placed therein and accommodating an expansion of the conductor. In another embodiment, an electromagnetic pump includes a stator of the electromagnetic pump including a number of laminations, a slot-liner positioned within a gap formed by the laminations, an annular wound copper conductor coil positioned within the slot-liner. The slot-liner includes a number of mica hard-boards joined to form an annular volume for insulating the conductor coil and accommodating an expansion of the conductor coil.

42 ENGINEERING↗

Temperature limited heater utilizing non-ferromagnetic conductor

A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

47 OTHER INSTRUMENTATION↗

Temperature limited heaters using phase transformation of ferromagnetic material

Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.

47 OTHER INSTRUMENTATION↗

Downhole transmission system

A transmission system in a downhole component comprises a data transmission element in both ends of the downhole component. Each data transmission element houses an electrically conducting coil in a MCEI circular trough. An electrical conductor connects both the transmission elements. The electrical conductor comprises at least three electrically conductive elements insulated from each other. In the preferred embodiment the electrical conductor comprises an electrically conducting outer shield, an electrically conducting inner shield and an electrical conducting core. In some embodiments of the present invention, the electrical conductor comprises an electrically insulating jacket. In other embodiments, the electrical conductor comprises a pair of twisted wires. In some embodiments, the electrical conductor comprises semi-conductive material.

47 OTHER INSTRUMENTATION↗

Temperature limited heater with a conduit substantially electrically isolated from the formation

A system for heating a hydrocarbon containing formation is described. A conduit may be located in an opening in the formation. The conduit includes ferromagnetic material. An electrical conductor is positioned inside the conduit, and is electrically coupled to the conduit at or near an end portion of the conduit so that the electrical conductor and the conduit are electrically coupled in series. Electrical current flows in the electrical conductor in a substantially opposite direction to electrical current flow in the conduit during application of electrical current to the system. The flow of electrons is substantially confined to the inside of the conduit by the electromagnetic field generated from electrical current flow in the electrical conductor so that the outside surface of the conduit is at or near substantially zero potential at 25.degree. C. The conduit may generate heat and heat the formation during application of electrical current.

47 OTHER INSTRUMENTATION↗

Induction heaters used to heat subsurface formations

A heating system for a subsurface formation includes an elongated electrical conductor located in the subsurface formation. The electrical conductor extends between at least a first electrical contact and a second electrical contact. A ferromagnetic conductor at least partially surrounds and at least partially extends lengthwise around the electrical conductor. The electrical conductor, when energized with time-varying electrical current, induces sufficient electrical current flow in the ferromagnetic conductor such that the ferromagnetic conductor resistively heats to a temperature of at least about 300.degree. C.

47 OTHER INSTRUMENTATION↗

Partial discharge sensor

An approach to detecting partial discharge events involves retrofitting an electrical system to include a capacitive sensor configured to capacitively sense partial discharge events of a component of the electrical system. The capacitive sensor has a first electrical conductor that forms a first terminal of the capacitive sensor, a second electrical conductor that forms a second terminal of the capacitive sensor, and a dielectric that separates the first electrical conductor and the second electrical conductor. The capacitive sensor generates an electrical sensor signal at an output of the capacitive sensor in response to the partial discharge event. The electrical sensor signal is converted to an optical signal and the optical signal is processed to detect an occurrence of the partial discharge event.

Karin, Todd↗

Floating insulated conductors for heating subsurface formations

A heating system for a subsurface formation includes a conduit located in a first opening in the subsurface formation. Three electrical conductors are located in the conduit. A return conductor is located inside the conduit. The return conductor is electrically coupled to the ends of the electrical conductors distal from the surface of the formation. Insulation is located inside the conduit. The insulation electrically insulates the three electrical conductors, the return conductor, and the conduit from each other.

42 ENGINEERING↗

Analysis of LH Launcher Arrays (Like the ITER One) Using the TOPLHA Code

TOPLHA (Torino Polytechnic Lower Hybrid Antenna) code is an innovative tool for the 3D/1D simulation of Lower Hybrid (LH) antennas, i.e. accounting for realistic 3D waveguides geometry and for accurate 1D plasma models, and without restrictions on waveguide shape, including curvature. This tool provides a detailed performances prediction of any LH launcher, by computing the antenna scattering parameters, the current distribution, electric field maps and power spectra for any user-specified waveguide excitation. In addition, a fully parallelized and multi-cavity version of TOPLHA permits the analysis of large and complex waveguide arrays in a reasonable simulation time. A detailed analysis of the performances of the proposed ITER LH antenna geometry has been carried out, underlining the strong dependence of the antenna input parameters with respect to plasma conditions. A preliminary optimization of the antenna dimensions has also been accomplished. Electric current distribution on conductors, electric field distribution at the interface with plasma, and power spectra have been calculated as well. The analysis shows the strong capabilities of the TOPLHA code as a predictive tool and its usefulness to LH launcher arrays detailed design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for enabling monitoring of power consumption

Power consumption at a site is monitored. An electrical load is connected to a power source by an electrical conductor. A fuel-less energy producing device is electrically connected to a junction along the electrical conductor. A current sensor is electromagnetically coupled to the electrical conductor at a sensing position between the power source and the junction to create a current sensor signal. Sensed current and voltage signals are produced from the current sensor signal. A sensed phase relationship between the sensed signals is determined and compared to a baseline phase relationship to determine the direction of current flow through the conductor. A power source signal, based on the current flowing through the conductor at the sensing position, is created. With some examples a Rogowski type differential current sensor is used. In some examples a single current sensor is used.

14 SOLAR ENERGY↗

Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration

A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

Vinegar, Harold J↗

Methods and apparatuses for operating nuclear reactors and for determining power levels in the nuclear reactors

An apparatus may include two or more electrical conductors, one or more signal devices, and an analyzer. The one or more signal devices may be adapted to apply one or more signals to the two or more electrical conductors and receive one or more signals from the two or more electrical conductors. The analyzer may be adapted to determine power level in the nuclear reactor using at least one of the applied signals and at least one of the received signals. A method of determining power level in a nuclear reactor may include: measuring impedance values of two or more electrical conductors disposed in the nuclear reactor and using the measured impedance values to determine the power level. A method of operating a nuclear reactor may include: measuring the impedance values and using the measured impedance values to determine parameters of the nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗