Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

As a Matter of Dynamical Range – Scale Dependent Energy Dynamics in MHD Turbulence

Abstract Magnetized turbulence is ubiquitous in many astrophysical and terrestrial plasmas but no universal theory exists. Even the detailed energy dynamics in magnetohydrodynamic (MHD) turbulence are still not well understood. We present a suite of subsonic, super-Alfvénic, high plasma beta MHD turbulence simulations that only vary in their dynamical range, i.e., in their separation between the large-scale forcing and dissipation scales, and their dissipation mechanism (implicit large eddy simulation, ILES, and direct numerical simulation (DNS)). Using an energy transfer analysis framework we calculate the effective numerical viscosities and resistivities, and demonstrate that all ILES calculations of MHD turbulence are resolved and correspond to an equivalent visco-resistive MHD turbulence calculation. Increasing the number of grid points used in an ILES corresponds to lowering the dissipation coefficients, i.e., larger (kinetic and magnetic) Reynolds numbers for a constant forcing scale. Independently, we use this same framework to demonstrate that—contrary to hydrodynamic turbulence—the cross-scale energy fluxes are not constant in MHD turbulence. This applies both to different mediators (such as cascade processes or magnetic tension) for a given dynamical range as well as to a dependence on the dynamical range itself, which determines the physical properties of the flow. We do not observe any indication of convergence even at the highest resolution (largest Reynolds numbers) simulation at 2048 3 cells, calling into question whether an asymptotic regime in MHD turbulence exists, and, if so, what it looks like.

79 ASTRONOMY AND ASTROPHYSICS↗

Pre-commissioning of the wide-dynamic range halo monitor to be installed in the Fermilab MI-8 line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, initial testing of equipment, and ray tracing simulations for the Offner optics and the targets used in the monitor.

Babacan, Betiay [IIT, Chicago; Fermilab]↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

High-dynamic-range quantum sensing of magnons and their dynamics using a superconducting qubit

Magnons, the quanta of collective spin excitations in magnetic materials, may enable functionalities, such as nonreciprocity and transduction in hybrid quantum devices. To assess the potential of such applications, it is necessary to understand magnon dynamics beyond the simple harmonic oscillator regime, where theory predicts effects like population-dependent damping and quantum fluctuations in the form of magnon shot noise. Probing these phenomena requires sensors with high sensitivity and the ability to resolve magnon properties across different excitation regimes. Here, we demonstrate accurate and sensitive detection of magnon population and decay over a wide range of occupation numbers. We use a superconducting qubit to probe magnons in a ferrimagnet over approximately 2000 excitations. Using qubit control and parametrically induced qubit-magnon interactions, we demonstrate few-excitation sensitive detection of magnons with a dynamic range of approximately 30 dB, and are able to accurately resolve their decay with few-ns sensitivity. These capabilities offer a powerful and practical technique for probing magnon dynamics in or beyond the linear regime over a wide range of excitations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Burn mode signatures enabled by high dynamic range fusion reaction history

The evolution of the fusion burn of a compressed inertial confinement fusion (ICF) implosion gives information about the evolution of the temperature, mass, and volume of the hot spot. Currently, the fusion reaction history has been measured with about a decade of dynamic range, giving information about just the peak of the fusion burn. There are proposals for extending the dynamic range to 1000×, measuring the rising edge of the burn earlier in time. Using fusion hot spot theory and a set of ICF simulations, we identify and categorize different stages of fusion burn and what signatures could be measured. For ice layered implosions, the details, conditions, and dynamics of the fusion burn propagation could be observed. For double shell and OMEGA scale implosions, the evolution of the final compression and rebounding shock before ignition could be observed. Higher dynamic range expands investigation into the logarithmic derivative, α, as a signature of various mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapidly Changing Range Limits in a Warming World: Critical Data Limitations and Knowledge Gaps for Advancing Understanding of Mangrove Range Dynamics in the Southeastern USA

Climate change is altering species’ range limits and transforming ecosystems. For example, warming temperatures are leading to the range expansion of tropical, cold-sensitive species at the expense of their cold-tolerant counterparts. In some temperate and subtropical coastal wetlands, warming winters are enabling mangrove forest encroachment into salt marsh, which is a major regime shift that has significant ecological and societal ramifications. Here, we synthesized existing data and expert knowledge to assess the distribution of mangroves near rapidly changing range limits in the southeastern USA. We used expert elicitation to identify data limitations and highlight knowledge gaps for advancing understanding of past, current, and future range dynamics. Mangroves near poleward range limits are often shorter, wider, and more shrublike compared to their tropical counterparts that grow as tall forests in freeze-free, resource-rich environments. The northern range limits of mangroves in the southeastern USA are particularly dynamic and climate sensitive due to abundance of suitable coastal wetland habitat and the exposure of mangroves to winter temperature extremes that are much colder than comparable range limits on other continents. Thus, there is need for methodological refinements and improved spatiotemporal data regarding changes in mangrove structure and abundance near northern range limits in the southeastern USA. Advancing understanding of rapidly changing range limits is critical for foundation plant species such as mangroves, as it provides a basis for anticipating and preparing for the cascading effects of climate-induced species redistribution on ecosystems and the human communities that depend on their ecosystem services.

54 ENVIRONMENTAL SCIENCES↗

Systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data

In accordance with some embodiments, systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data are provided. In some embodiments, the system comprises: first detectors configured to detect a level of photons proportional to incident photon flux; second detectors configured to detect arrival of individual photons; a processor programmed to: receive, from the first detectors, first values indicative of photon flux from a scene with a first resolution; receive, from the second detectors, second values indicative of photon flux from the scene with a lower resolution; provide a first encoder of a trained machine learning model first flux values based on the first values, provide the second encoder of the model second flux values; receive, as output, values indicative of photon flux from the scene; and generate a high dynamic range image based on the third plurality of values.

Gutierrez Barragan, Felipe↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of inoculation with prion dilutions within the dynamic range of ELISA absorbance on prion incubation period

This study examines the effect of various infectious prion titers within the dynamic range as measured by ELISA on incubation period. We inoculated ovinized transgenic mice with seven decreasing dilutions of a fast-incubating scrapie strain. The highest inoculum group was a 20% w/v brain homogenate from a sheep with scrapie. The subsequent six inoculum dilutions ranged from the highest ELISA optical density reading of 4.000 to a dilution where scrapie prions were not detectable by ELISA. Multiple comparison analysis demonstrated variation in the incubation periods between some inoculum groups. Incubation periods were similar between inoculum groups unless their optical density differed by more than ≈2 units of absorbance. These data will inform the interpretation of future studies that compare incubation periods in experimentally inoculated animals for TSE research.

60 APPLIED LIFE SCIENCES↗

Apparatus and method for high dynamic range counting by pixelated detectors

The present disclosure relates to an apparatus and methods for generating a hybrid image by high-dynamic-range counting. In an embodiment, the apparatus includes a processing circuitry configured to acquire an image from a pixelated detector, obtain a sparsity map of the acquired image, the sparsity map indicating low-flux regions of the acquired image and high-flux regions of the acquired image, generate a low-flux image and a high-flux image based on the sparsity map, perform event analysis of the acquired image based on the low-flux image and the high-flux image, the event analysis including detecting, within the low-flux image, incident events by an event counting mode, multiply, by a normalization constant, resulting intensities of the high-flux image and the detected incident events of the low-flux image, and generate the hybrid image by merging the low-flux image and the high-flux image.

Bammes, Benjamin↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Large dynamic range digital delay with sub-picosecond precision

Abstract We report on the development and performance of a digitally controlled phase delay with a step of 280 femtoseconds and a dynamic range of 230 picoseconds. Details of the device design and the simulations as well as comparisons with laboratory measurements will be discussed. We describe how we have used this ASIC to stabilize a digital clock to a precision of less than one picosecond.

Instruments & Instrumentation↗

High framerate and high dynamic range electron microscopy

Methods and systems for acquiring transmission electron microscope video data on a rolling-shutter detector at an enhanced frame rate and without temporal distortions are described. Also described are methods to enhance the dynamic range of image and diffraction data acquired using a transmission electron microscope. The disclosed methods and systems may also be applicable to photon detection and imaging systems.

Bloom, Ruth↗

NucD-25 Nuclear Diagnostics Development: NIS capability, Maximizing gamma ray dynamic range, (n,γ) measurements for carbon ρR [Slides]

The LANL Neutron Imaging team is preparing for NIS upgrades and novel capabilities with the advent of consistently higher yields at NIF. Novel scintillators, solid-state detectors, multiplexed imaging detectors, upgraded data acquisition systems, and camera testing are all areas in need of experimental study to further develop imaging capabilities and dynamic range at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗