Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dust removal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An experimental study on the characterization of electric charge in electrostatic dust removal

Automatic dust removal using the electrostatic forces of electrodynamic screen (EDS) is an emerging method for mitigation of energy yield losses caused by dust accumulation on solar collectors. Both electric field distribution and dust particles' charge acquired during the removal process play pivotal roles in thorough evaluation of EDS performance. Previous studies have comprehensively analyzed the electric field distribution in EDS. In this paper we have conducted a number of experiments to examine how two EDS design parameters, electrode width and inter-electrode spacing, and two operational parameters, applied voltage and relative humidity, affect dust particles' charge. Sixteen EDS prototypes in two sets were developed and tested in a laboratory environment to study the acquired charge by dust particles via charge-to-mass ratio measurements. It has been shown that the charge-to-mass ratio is directly affected by the electric field intensity on an EDS surface. Furthermore, we have shown the detrimental impact of relative humidity on EDS performance. Here, the results are advantageous in the evaluation of EDS design and its optimization to attain maximum dust removal efficiency.

14 SOLAR ENERGY↗

Evaluation of an Electrostatic Dust Removal System with Potential Application in Next-Step Fusion Devices

The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 mm3 volume of carbon and tungsten particles were moved in under 5 seconds. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon, and the change in particle distribution over short timescales (<1 s).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of an electrostatic dust removal system with potential application in next-step fusion devices

The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass, and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 mm{sup 3} volume of carbon and tungsten particles were moved in under 5 s. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon and the change in particle distribution over short timescales (<1 s).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an Electrostatic Dust Removal System with Potential Application in Next-Step Fusion Devices

The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 mm3 volume of carbon and tungsten particles were moved in under 5 seconds. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon, and the change in particle distribution over short timescales (<1 s).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dust removal in radio-frequency plasmas by a traveling potential modulation

The dust contamination in plasma deposition processes plays a crucial role in the quality and the yield of the products. To improve the quality and the yield of plasma processing, a favorable way is to remove the dust particles actively from the plasma reactors.Our recent experiments in the striped electrode device show that a traveling plasma modulation allows for a systematic particle removal independent of the reactor size. Besides the rf powered electrode, the striped electrode device includes a segmented electrode that consists of 100 electrically insulated narrow stripes. A traveling potential profile is produced by the modulation of the voltage signals applied on the stripes. The dust particles are trapped in the potential wells and transported with the traveling of the potential profile.The particle-in-cell (PIC) simulation on the potential above the segmented electrode indicates that the traveling potential profile can be realized either by applying low-frequency (0.1-10 Hz) voltage signals with a fixed phase shift between adjacent stripes or high-frequency (10 kHz a circumflex AS 100 MHz) signals with the amplitudes modulated by a low-frequency envelope. The transportation of the dust particles is simulated with a two-dimensional molecular dynamics (MD) code with the potential profile obtained from the PIC simulation. The MD results reproduce the experimental observations successfully.This technology allows for an active removal of the contaminating particles in processing plasmas and it is independent of the reactor size. The removal velocity is controllable by adjusting the parameters for the modulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lithium wall conditioning and surface dust detection on NSTX, and dust removal

Lithium evaporation onto National Spherical Torus Experiment (NSTX) plasma-facing components (PFCs) has resulted in improved energy confinement, and reductions in the number and amplitude of edge-localized modes (ELMs) up to the point of complete ELM suppression. The associated PFC surface chemistry has been investigated with a novel plasma-material interface probe connected to an in-vacuo surface analysis station. Analysis has demonstrated that the binding of D atoms to the polycrystalline graphite material of PFCs is fundamentally changed by lithium-in particular, deuterium atoms become weakly bonded near lithium atoms themselves bound to either oxygen or the carbon from the underlying material. Surface dust inside NSTX has been detected in real time using a highly sensitive electrostatic dust detector. In a separate experiment, electrostatic removal of dust via three concentric spiral-shaped electrodes covered by a dielectric and driven by a high-voltage three-phase waveform was evaluated for its potential application to fusion reactors.

36 MATERIALS SCIENCE↗

ADVANCES IN DUST DETECTION AND REMOVAL FOR TOKAMAKS

Dust diagnostics and removal techniques are vital for the safe operation of next step fusion devices such as ITER. In the tokamak environment, large particles or fi bers can fall on the electrostatic detector potentially causing a permanent short. An electrostatic dust detector developed in the laboratory is being applied to the National Spherical Torus Experiment (NSTX). We report on the development of a gas puff system that uses helium to clear such particles from the detector. Experiments at atmospheric pressure with varying nozzle designs, backing pressures, puff durations and exit fl ow orientations have given an optimal confi guration that effectively removes particles from a 25 cm² area. Similar removal effi ciencies were observed under a vacuum base pressure of 1 mTorr. Dust removal from next step tokamaks will be required to meet regulatory dust limits. A tri-polar grid of fi ne interdigitated traces has been designed that generates an electrostatic traveling wave for conveying dust particles to a “drain.” First trials with only two working electrodes have shown particle motion in optical microscope images.

Campos, A↗

Electrostatic force distribution on an electrodynamic screen

The enormous potential of solar energy harvesting plants to provide clean energy is severely limited by dust accumulation on their optical surfaces. In lieu of the most commonly-practiced manual cleaning method of using high-pressure water jets, electrodynamic screen (EDS) technology offers an attractive solution for removing dust particles from optical surfaces using electrostatic forces. In this paper, the impacts of different EDS design parameters in the electric field distribution on an EDS have been studied. Furthermore, based on electric field expressions, closed-form solutions for multipolar dielectrophoretic (DEP) forces in the EDS application are provided. Detailed evaluation of the EDS performance necessi- tates investigation of different forces involved in the dust removal process. Different comparisons are made between repelling and attracting forces exerted on dust particles deposited on an EDS surface. These comparisons elucidate EDS performance in the removal of a given size range of dust particles. The significant detrimental impact of relative humidity upon the dust removal process is quantitatively addressed. As a result, it is shown how just a 10 percent increase in relative humidity can make the repelling force ineffective in the dust removal process.

14 SOLAR ENERGY↗

On the impact of large angle CMB polarization data on cosmological parameters

We study the impact of the large-angle CMB polarization datasets publicly released by the WMAP and Planck satellites on the estimation of cosmological parameters of the ΛCDM model. To complement large-angle polarization, we consider the high resolution (or "high-ℓ") CMB datasets from either WMAP or Planck as well as CMB lensing as traced by Planck's measured four point correlation function. In the case of WMAP, we compute the large-angle polarization likelihood starting over from low resolution frequency maps and their covariance matrices, and perform our own foreground mitigation technique, which includes as a possible alternative Planck 353 GHz data to trace polarized dust. We find that the latter choice induces a downward shift in the optical depth τ, roughly of order 2σ, robust to the choice of the complementary high resolution dataset. When the Planck 353 GHz is consistently used to minimize polarized dust emission, WMAP and Planck 70 GHz large-angle polarization data are in remarkable agreement: by combining them we find τ = 0.066 +0.012-0.013, again very stable against the particular choice for high-ℓ data. We find that the amplitude of primordial fluctuations As, notoriously degenerate with τ, is the parameter second most affected by the assumptions on polarized dust removal, but the other parameters are also affected, typically between 0.5 and 1σ. In particular, cleaning dust with Planck's 353 GHz data imposes a 1σ downward shift in the value of the Hubble constant H0, significantly contributing to the tension reported between CMB based and direct measurements of the present expansion rate. On the other hand, we find that the appearance of the so-called low ℓ anomaly, a well-known tension between the high- and low-resolution CMB anisotropy amplitude, is not significantly affected by the details of large-angle polarization, or by the particular high-ℓ dataset employed.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrostatic dust remediation for future exploration of the Moon

Dust accumulation is one of the critical issues that must be mitigated on in-situ lunar explorations because an in-situ probe is exposed to small dust particles, which are easily attached to it, during its operations. The Lunar Dust Science Definition Team is organized by the Jet Propulsion Lab/California Institute of Technology through NASA’s Biological and Physical Sciences Division to define key science questions and assess dust remediation techniques. Here, we assess three electrostatic remediation technology concepts: electrostatic dust shield; surface electrostatically collecting dust, later called attractive surface; and electron beam — plasma jet inducing electrostatic dust lofting from a surface. We qualitatively investigate their maturity by defining six operational factors: Time and location; Amount of dust removal; Contamination of target surfaces; Operation duration; Installation; and Safety. In addition to these techniques, we discuss a supporting system that loads dust particles onto a test article to examine dust removal efficiency. Here, the results show that further development increases the maturity of all the technologies. While laboratory and theoretical demonstrations reported whether each technology robustly work on the Moon, which hosts a complex, heterogeneous dust environment, we find that it is still uncertain if this is the case because none has been tested in the lunar environment. Particularly, operation duration and safety are critical to be addressed further on both laboratory and spaceflight scales.

42 ENGINEERING↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Electrostatic Dust Detection and Removal for ITER

We present some recent results on two innovative applications of microelectronics technology to dust inventory measurement and dust removal in ITER. A novel device to detect the settling of dust particles on a remote surface has been developed in the laboratory. A circuit board with a grid of two interlocking conductive traces with 25 μm spacing is biased to 30 – 50 V. Carbon particles landing on the energized grid create a transient short circuit. The current flowing through the short circuit creates a voltage pulse that is recorded by standard nuclear counting electronics and the total number of counts is related to the mass of dust impinging on the grid. The particles typically vaporize in a few seconds restoring the previous voltage standoff. Experience on NSTX however, showed that in a tokamak environment it was still possible for large particles or fibers to remain on the grid causing a long term short circuit. We report on the development of a gas puff system that uses helium to clear such particles. Experiments with varying nozzle designs, backing pressures, puff durations, and exit flow orientations have given an optimal configuration that effectively removes particles from an area up to 25 cm² with a single nozzle. In a separate experiment we are developing an advanced circuit grid of three interlocking traces that can generate a miniature electrostatic traveling wave for transporting dust to a suitable exit port. We have fabricated such a 3-pole circuit board with 25 micron insulated traces that operates with voltages up to 200 V. Recent results showed motion of dust particles with the application of only 50 V bias voltage. Such a device could potentially remove dust continuously without dedicated interventions and without loss of machine availability for plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatic Dust Detector with Improved Sensitivity

Methods to measure the inventory of dust particles and to remove dust if it approaches safety limits will be required in next-step tokamaks such as ITER. An electrostatic dust detector, based on a fine grid of interlocking circuit traces, biased to 30 or 50 V, has been developed for the detection of dust on remote surfaces in air and vacuum environments. Gaining operational experience of dust detection on surfaces in tokamaks is important, however the level of dust generated in contemporary short-pulse tokamaks is comparatively low and high sensitivity is necessary to measure dust on a shot-by-shot basis. We report on modifications in the detection electronics that have increased the sensitivity of the electrostatic dust detector by a factor of up to 120, - a level suitable for measurements on contemporary tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comprehensive analysis of the electric field distribution in an electrodynamic screen

The electrodynamic screen, or EDS, has shown promising results in mitigation of dust accumulation losses in solar energy harvesting systems. In this paper, the electric field distributions in two EDS con- figurations have been thoroughly investigated. The analytical solutions for the electric potential and electric field distribution in the first EDS configuration have been provided and corroborated numerically using finite element analysis (FEA) software. The electrostatic model of second EDS configuration has been developed in the FEA software and its electric field distribution has been analyzed numerically. Here, a comparison has been made between the two configurations regarding dust removal efficiency.

14 SOLAR ENERGY↗

DISCOVERY OF 'WARM DUST' GALAXIES IN CLUSTERS AT z {approx} 0.3: EVIDENCE FOR STRIPPING OF COOL DUST IN THE DENSE ENVIRONMENT?

Using far-infrared imaging from the 'Herschel Lensing Survey', we derive dust properties of spectroscopically confirmed cluster member galaxies within two massive systems at z {approx} 0.3: the merging Bullet Cluster and the more relaxed MS2137.3-2353. Most star-forming cluster sources ({approx}90%) have characteristic dust temperatures similar to local field galaxies of comparable infrared (IR) luminosity (T{sub dust} {approx} 30 K). Several sub-luminous infrared galaxy (LIRG; L{sub IR} < 10{sup 11} L{sub Sun }) Bullet Cluster members are much warmer (T{sub dust} > 37 K) with far-infrared spectral energy distribution (SED) shapes resembling LIRG-type local templates. X-ray and mid-infrared data suggest that obscured active galactic nuclei do not contribute significantly to the infrared flux of these 'warm dust' galaxies. Sources of comparable IR luminosity and dust temperature are not observed in the relaxed cluster MS2137, although the significance is too low to speculate on an origin involving recent cluster merging. 'Warm dust' galaxies are, however, statistically rarer in field samples (>3{sigma}), indicating that the responsible mechanism may relate to the dense environment. The spatial distribution of these sources is similar to the whole far-infrared bright population, i.e., preferentially located in the cluster periphery, although the galaxy hosts tend toward lower stellar masses (M{sub *} < 10{sup 10} M{sub Sun }). We propose dust stripping and heating processes which could be responsible for the unusually warm characteristic dust temperatures. A normal star-forming galaxy would need 30%-50% of its dust removed (preferentially stripped from the outer reaches, where dust is typically cooler) to recover an SED similar to a 'warm dust' galaxy. These progenitors would not require a higher IR luminosity or dust mass than the currently observed normal star-forming population.

79 ASTRONOMY AND ASTROPHYSICS↗

DEBRIS DISKS IN KEPLER EXOPLANET SYSTEMS

The Kepler mission recently identified 997 systems hosting candidate extrasolar planets, many of which are super-Earths. Realizing these planetary systems are candidates to host extrasolar asteroid belts, we use mid-infrared data from the Wide-field Infrared Survey Explorer (WISE) to search for emission from dust in these systems. We find excesses around eight stars, indicating the presence of warm to hot dust ({approx}100-500 K), corresponding to orbital distances of 0.1-10 AU for these solar-type stars. The strongest detection, KOI 1099, demands {approx}500 K dust interior to the orbit of its exoplanet candidate. One star, KOI 904, may host very hot dust ({approx}1200 K, corresponding to 0.02 AU). Although the fraction of these exoplanet-bearing stars with detectable warm excesses ({approx}3%) is similar to that found by Spitzer surveys of solar-type field stars, the excesses detectable in the WISE data have much higher fractional luminosities (L{sub dust}/L{sub *}) than most known debris disks, implying that the fraction with debris disks of comparable luminosity may actually be significantly higher. It is difficult to explain the presence of dust so close to the host stars, generally corresponding to dust rings at radii <0.3 AU; both the collisional and Poynting-Robertson drag timescales to remove dust from the system are hundreds of years or less at these distances. Assuming a steady state for these systems implies large mass consumption rates with these short removal timescales, meaning that the dust production mechanism in these systems must almost certainly be episodic in nature.

79 ASTRONOMY AND ASTROPHYSICS↗

CANDELS: THE EVOLUTION OF GALAXY REST-FRAME ULTRAVIOLET COLORS FROM z = 8 TO 4

We study the evolution of galaxy rest-frame ultraviolet (UV) colors in the epoch 4 {approx}< z {approx}< 8. We use new wide-field near-infrared data in the Great Observatories Origins Deep Survey-South field from the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey, Hubble Ultra Deep Field (HUDF) 2009, and Early Release Science programs to select galaxies via photometric redshift measurements. Our sample consists of 2812 candidate galaxies at z {approx}> 3.5, including 113 at z {approx_equal} 7-8. We fit the observed spectral energy distribution to a suite of synthetic stellar population models and measure the value of the UV spectral slope ({beta}) from the best-fit model spectrum. We run simulations to show that this measurement technique results in a smaller scatter on {beta} than other methods, as well as a reduced number of galaxies with catastrophically incorrect {beta} measurements (i.e., {Delta}{beta} > 1). We find that the median value of {beta} evolves significantly from -1.82{sup +0.00}{sub -0.04} at z = 4 to -2.37{sup +0.26}{sub -0.06} at z = 7. Additionally, we find that faint galaxies at z = 7 have {beta} -2.68{sup +0.39}{sub -0.24} ({approx} -2.4 after correcting for observational bias); this is redder than previous claims in the literature and does not require 'exotic' stellar populations (e.g., very low metallicities or top-heavy initial mass functions) to explain their colors. This evolution can be explained by an increase in dust extinction, from low amounts at z = 7 to A{sub V} {approx} 0.5 mag at z = 4. The timescale for this increase is consistent with low-mass asymptotic giant branch stars forming the bulk of the dust. We find no significant (<2{sigma}) correlation between {beta} and M{sub UV} when measuring M{sub UV} at a consistent rest-frame wavelength of 1500 A. This is particularly true at bright magnitudes, though our results do show evidence for a weak correlation at faint magnitudes when galaxies in the HUDF are considered separately, hinting that dynamic range in sample luminosities may play a role. We do find a strong correlation between {beta} and the stellar mass at all redshifts, in that more massive galaxies exhibit redder colors. The most massive galaxies in our sample have similarly red colors at each redshift, implying that dust can build up quickly in massive galaxies and that feedback is likely removing dust from low-mass galaxies at z {>=} 7. Thus, the stellar-mass-metallicity relation, previously observed up to z {approx} 3, may extend out to z = 7-8.

79 ASTRONOMY AND ASTROPHYSICS↗