Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dual-mode sorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

New Insights into Physical Aging-Induced Structure Evolution in Carbon Molecular Sieve Membranes

Carbon molecular sieve (CMS) membranes offer the best available combination of scalable economical processability with excellent separation performance. Physical aging of CMS membranes causes pore structure changes over time that affect CMS membrane performance. To provide fundamental insights into the structure evolution in CMS membranes during physical aging, a combined dual-mode sorption and transport model is used in this study to characterize the diffusion coefficients of gas molecules in fresh and 7-day vacuum aged CMS membranes. Further, the results show physical aging of CMS membrane is primarily “diffusion related” and such aging behavior simultaneously causes ultramicropore changes in the continuous phase and Langmuir phase of CMS membrane. The new insights offered in this study suggest strategies to control the physical aging of CMS membranes and even use it as a valuable tool to tune the separation performance of CMS membranes for demanding gas separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pure- and mixed-gas transport properties of a microporous Tröger's Base polymer (PIM-EA-TB)

Polymers of intrinsic microporosity (PIMs) offer tantalizing combinations of high selectivity and permeability in initial gas permeation measurements. Here, we report characterization of pure- and mixed-gas permeation properties of a thick (~80 μm) PIM consisting of Tröger's Base (TB) and Ethanoanthracene (EA) films. The effects of feed pressure and temperature on pure-gas permeabilities of CH 4 , N 2 , O 2 , H 2 , and CO 2 were investigated. The physical aging behavior of the thick film was tracked via pure-gas O 2 , N 2 , and CH 4 permeability at 35 °C. Gas permeability decreased noticeably and selectivity increased as aging time increased. Particular attention was given to mixed-gas measurements of CO 2 and CH 4 (50/50) permeabilities at 35 °C and fugacities ranging from 2 to 18 atm to explore whether the rigid, bridged, bicyclic TB and EA units could resist CO 2 -induced plasticization. These results are presented along with pure-gas CO 2 and CH 4 results for membrane samples aged at different times. PIM-EA-TB aged for ~24 h did not show signs of plasticization across the fugacity range considered. Furthermore, dual-mode competitive sorption presumably caused the CO 2 /CH 4 mixed-gas selectivity to be slightly higher than its corresponding pure-gas selectivity. However, as aging time increased, aged films underwent progressively more rapid and extensive CO 2 -induced plasticization with increasing fugacity, suggesting a systematic relationship between physical aging and plasticization in PIMs. Consequently, physical aging caused less improvement in mixed-gas CO 2 /CH 4 selectivity than it did in pure-gas selectivity, due mainly to plasticization effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UNESE Data Analysis-Disko Elm Gas Transport Characteristics (NA-22 Quarterly Report)

Recently published papers have demonstrated the impact of sorption mechanisms on gas transport in the subsurface following an underground nuclear explosion. To include sorption processes in the multi-physics models of noble gas production and transport, researchers have conducted experiments of gas sorption in geologic materials and calibrated a linear (Henry’s law) sorption model for all gases in various geologic materials. As a part of Task #4, we requested the experimental data from Sandia Laboratories and derived a dual-mode (Henry’s absorption and Langmuir adsorption) sorption model. The derived model better describes the nonlinear sorption mechanism with much higher fitness with the experimental data. When gas concentrations are relatively low (in the conditions of field experiments or underground nuclear explosions) compared to those used sorption experiments, the nonlinear sorption model can be approximated as a linear sorption model. The equivalent Henry’s constant, which equals the product of Langmuir capacity and affinity, is systematically higher than the literature values. Further analyses and comparison of sorption models are planned in FY2020 Q4 and the sorption model will be coupled in models of nonisothermal multiphase transport for studying noble gas detectability.

58 GEOSCIENCES↗

Permeation of CO 2 and N 2 through glassy poly(dimethyl phenylene) oxide under steady- and presteady-state conditions

Glassy polymers are often used for gas separations because of their high selectivity. Although the dual-mode permeation model correctly fits their sorption and permeation isotherms, its physical interpretation is disputed, and it does not describe permeation far from steady state, a condition expected when separations involve intermittent renewable energy sources. To develop a more comprehensive permeation model, we combine experiment, molecular dynamics, and multiscale reaction–diffusion modeling to characterize the time-dependent permeation of N 2 and CO 2 through a glassy poly(dimethyl phenylene oxide) membrane, a model system. Simulations of experimental time-dependent permeation data for both gases in the presteady-state and steady-state regimes show that both single- and dual-mode reaction–diffusion models reproduce the experimental observations, and that sorbed gas concentrations lag the external pressure rise. The results point to environment-sensitive diffusion coefficients as a vital characteristic of transport in glassy polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗