Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Dome-C”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Additional Characterization of Dome-C to Improve its Use as an Invariant Visible Calibration Target

Dome-C is a recommended CEOS invariant target that has been utilized by the calibration community for several decades for monitoring onboard sensor calibration systems as well radiometric inter-comparisons. Dome-C is a high-altitude Earth target located on the East Antarctic interior plateau, which has a permanent bright, flat, and homogeneous snow-covered surface with little aerosol, cloud cover, snowfall, and water vapor burden. This paper describes angular directional models for characterizing the Dome-C top-of-atmosphere (TOA)radiances as a function of cosine solar zenith angle for pre-solstice and post-solstice conditions. The 0.86-μm channel Dome-C reflectance decreases over the summer due to snow metamorphosisis not observed by the visible channels. Coinciding Terra and AquaMODIS Dome-C reflectance showed occasional inter-annual anomalies when compared against the deep convective cloud and Libya-4 invariant targets observations. Further characterization of the Dome-C reflectances with the Dome-C surface broadband albedo, Antarctic Oscillation(AAO) index, and ozone concentration values were evaluated. A strong correlation with ozone was found for the 0.55-μm and 0.65-μm MODIS channels. The monthly Dome-C reflectances were linearly regressed with ozone to derive the ozone correction coefficients. The uncertainty in the Aqua-and Terra-MODIS Dome-C trends was reduced by half after applying ozone corrections to both the 0.55-μm and 0.65-μm channelTOA observations.

David R Doelling

Evaluation of Aqua MODIS and S-NPP VIIRS Thermal Emissive Bands Calibration Stability Using Dome-C

Establishing the calibration consistency between satellite measurements is an essential step in the implementation of a long-term global monitoring plan, which often leads to sensor calibration improvements. The Suomi National Polar-Orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) is a polar-orbiting Earth remote sensing instrument built with a strong Moderate Resolution Imaging Spectroradiometer (MODIS) heritage. The center wavelengths of all VIIRS thermal emissive bands (TEBs) match well with those of MODIS with the exception of VIIRS TEB M15 (10.7μm). Previous work from the MODIS Characterization Support Team (MCST) at the NASA/GSFC used specific Earth surface targets to track the long-term consistency,stability, and relative bias between the two MODIS instruments onboard the Terra and Aqua satellites. Using similar methodologies, this paper evaluates the TEB calibration consistency between the MODIS instruments and S-NPP VIIRS over Dome Concordia (Dome-C). The Dome-C site is uniformly snow-covered and the atmospheric effects are small in the surrounding area. Near-surface air temperature measurements from an Automatic Weather Station (AWS) are used as a reference to track each sensor’s calibration stability and determine the relative bias between the MODIS and VIIRS instruments. The results of this study provide a quantitative assessment of the S-NPP VIIRS TEB mission-long performance.

MODIS

Improved Spectral and Angular Characterization of Libya-4 and Dome-C for consistent MODIS and VIIRS Radiometric Scaling

The NASA CERES observed SW and LW fluxes are utilized by the climate community for monitoring the Earth’s energy imbalance and for climate model validation. To facilitate seamless flux and cloud properties across MODIS, VIIRS, and geostationary (GEO) imagers the CERES project intercalibrates the imagers directly comparing the coincident ray-matched analogous channel radiances. For CERES edition 4 products, the MODIS, VIIRS and GEO imagers were radiometrically scaled to the Aqua-MODIS C5 calibration reference. There are no direct comparison opportunities between NPP and NOAA20 VIIRS, since they are positioned a half an orbit apart. The previous usage of Aqua-MODIS as a transfer radiometer is coming to an end, since the Aqua orbit is slowly drifting towards the terminator and will be deorbited in 2026. The CERES project will utilize the Libya-4 and Dome-C invariant targets to radiometrically scale between MODIS and VIIRS reflective solar bands. The Libya-4 and Dome-C Earth invariant targets will be characterized by the repeat cycle angular configuration. The target spectral band adjustment factors (SBAF) will be derived using EMIT and DESIS hyper-spectral observations onboard the ISS and will be compared with the existing SCIAMACHY, GOME-2, and Hyperion SBAFs. The DESIS and EMIT SBAF approach can incorporate the future CLARREO CPF SI traceable hyper-spectral measurements allowing the targets to be referenced to an absolute calibration reference. Utilizing the BRDF and atmospheric corrected characterization of one sensor with another will provide the scaling factors. Consistent scaling factors between the two invariant target validates the method.

David R. Doelling

Normalization Method and Application for MODIS TEB Assessments using Earth Scene Measurements

Selected Earth targets are commonly used for satellite sensor calibration assessments (e.g. sensor stability and inter-comparisons). Moreover, typical scenes used for the calibration assessment of the thermal emissive bands (TEBs) includeDome Concordia (Dome-C), ocean, desert, and deep convective clouds (DCC). Reference data used for these calibration assessments can come from another band, another instrument, or ground measurements. The Dome-C site, covered with uniformly-distributed permanent snow, is normally used for the assessment of the TEBsat cold temperatures. Furthermore, ocean and desert measurements prove useful for scenes with higher temperatures. The DCC, one of the most consistent and coldest targets, can be used for the TEBs calibration and product stability assessments. MODIS band 31 (~ 11 m) can be used as a reference for these scenes. However, measurements over these scenes have seasonal variations, and the DCC brightness temperatures (BTs) have asymmetrical distributions. These features can introduce additional uncertainty to the stability assessments. A normalization method is applied by using an empirical model to derive reference-dependent BTs. Using the developed empirical model, measurements can be normalized to a reference BT in order to enhance the calibration assessment’s accuracy. This method is evaluated using all four scene types (i.e. ocean, desert, snow (Dome-C), and DCC) and applied to all the Terra and Aqua MODIS TEBs. Stability assessments over the instruments’ entire data records are presented and discussed. The technique can be applied in future efforts to support MODIS TEBs calibration assessments.

MODIS TEB

Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality.

Chang, Tiejun

An Evaluation of Antarctica as a Calibration Target for Passive Microwave Satellite Missions with Climate Data Record Applications

Passive microwave remote sensing at L-band (1.4 GHz) is sensitive to soil moisture and sea surface salinity, both important climate variables. Science studies involving these variables can now take advantage of new satellite L-band observations. The first mission with regular global passive microwave observations at L-band is the European Space Agency's Soil Moisture and Ocean Salinity (SMOS), launched November, 2009. A second mission, NASA's Aquarius, was launched June, 201 I. A third mission, NASA's Soil Moisture Active Passive (SMAP) is scheduled to launch in 2014. Together, these three missions may provide a decade-long data record-provided that they are intercalibrated. The intercalibration is best performed at the radiance (brightness temperature) level, and Antarctica is proving to be a key calibration target. However, Antarctica has thus far not been fully characterized as a potential target. This paper will present evaluations of Antarctica as a microwave calibration target for the above satellite missions. Preliminary analyses have identified likely target areas, such as the vicinity of Dome-C and larger areas within East Antarctica. Physical sources of temporal and spatial variability of polar firn are key to assessing calibration uncertainty. These sources include spatial variability of accumulation rate, compaction, surface characteristics (dunes, micro-topography), wind patterns, and vertical profiles of density and temperature. Using primarily SMOS data, variability is being empirically characterized and attempts are being made to attribute observed variability to physical sources. One expected outcome of these studies is the potential discovery of techniques for remotely sensing--over all of Antarctica-parameters such as surface temperature.

Kim, Edward

An Evaluation of Antarctica as a Calibration Target for Passive Microwave Satellite Missions

Passive microwave remote sensing at L-band (1.4 GHz) is sensitive to soil moisture and sea surface salinity, both important climate variables. Science studies involving these variables can now take advantage of new satellite L-band observations. The first mission with regular global passive microwave observations at L-band is the European Space Agency's Soil Moisture and Ocean Salinity (SMOS), launched November, 2009. A second mission, NASA's Aquarius, was launched June, 201l. A third mission, NASA's Soil Moisture Active Passive (SMAP) is scheduled to launch in 2014. Together, these three missions may provide a decade-long data record -- provided that they are intercalibrated. The intercalibration is best performed at the radiance (brightness temperature) level, and Antarctica is proving to be a key calibration target. However, Antarctica has thus far not been fully characterized as a potential target. This paper will present evaluations of Antarctica as a microwave calibration target for the above satellite missions. Preliminary analyses have identified likely target areas, such as the vicinity of Dome-C and larger areas within East Antarctica. Physical sources of temporal and spatial variability of polar firn are key to assessing calibration uncertainty. These sources include spatial variability of accumulation rate, compaction, surface characteristics (dunes, micro-topography), wind patterns, and vertical profiles of density and temperature. Using primarily SMOS data, variability is being empirically characterized and attempts are being made to attribute observed variability to physical sources. One expected outcome of these studies is the potential discovery of techniques for remotely sensing--over all of Antarctica--parameters such as surface temperature.

Kim, Edward

Model Development for MODIS Thermal Band Electronic Crosstalk

MODerate-resolution Imaging Spectroradiometer (MODIS) has 36 bands. Among them, 16 thermal emissive bands covering a wavelength range from 3.8 to 14.4 m. After 16 years on-orbit operation, the electronic crosstalk of a few Terra MODIS thermal emissive bands developed substantial issues that cause biases in the EV brightness temperature measurements and surface feature contamination. The crosstalk effects on band 27 with center wavelength at 6.7 m and band 29 at 8.5 m increased significantly in recent years, affecting downstream products such as water vapor and cloud mask. The crosstalk effect is evident in the near-monthly scheduled lunar measurements, from which the crosstalk coefficients can be derived. The development of an alternative approach is very helpful for independent verification.In this work, a physical model was developed to assess the crosstalk impact on calibration as well as in Earth view brightness temperature retrieval. This model was applied to Terra MODIS band 29 empirically to correct the Earth brightness temperature measurements. In the model development, the detectors nonlinear response is considered. The impact of the electronic crosstalk is assessed in two steps. The first step consists of determining the impact on calibration using the on-board blackbody (BB). Due to the detectors nonlinear response and large background signal, both linear and nonlinear coefficients are affected by the crosstalk from sending bands. The second step is to calculate the effects on the Earth view brightness temperature retrieval. The effects include those from affected calibration coefficients and the contamination of Earth view measurements. This model links the measurement bias with crosstalk coefficients, detector non-linearity, and the ratio of Earth measurements between the sending and receiving bands. The correction of the electronic cross talk can be implemented empirically from the processed bias at different brightness temperature. The implementation can be done through two approaches. As routine calibration assessment for thermal infrared bands, the trending over select Earth scenes is processed for all the detectors in a band and the band averaged bias is derived at a certain time. In this case, the correction of an affected band can be made using the regression of the model with band averaged bias and then corrections of detector differences are applied. The second approach requires the trending for individual detectors and the bias for each detector is used for regression with the model. A test using the first approach was made for Terra MODIS band 29 with the biases derived from long-term trending of brightness temperature over ocean and Dome-C.

Chang, Tiejun

Optimization of a Deep Convective Cloud Technique in Evaluating the Long-Term Radiometric Stability of MODIS Reflective Solar Bands

MODIS reflective solar bands are calibrated on-orbit using a solar diffuser and near-monthly lunar observations. To monitor the performance and effectiveness of the on-orbit calibrations, pseudo-invariant targets such as deep convective clouds (DCCs), Libya-4, and Dome-C are used to track the long-term stability of MODIS Level 1B product. However, the current MODIS operational DCC technique (DCCT) simply uses the criteria set for the 0.65- m band. We optimize several critical DCCT parameters including the 11- micrometer IR-band Brightness Temperature (BT11) threshold for DCC identification, DCC core size and uniformity to help locate DCCs at convection centers, data collection time interval, and probability distribution function (PDF) bin increment for each channel. The mode reflectances corresponding to the PDF peaks are utilized as the DCC reflectances. Results show that the BT11 threshold and time interval are most critical for the Short Wave Infrared (SWIR) bands. The Bidirectional Reflectance Distribution Function model is most effective in reducing the DCC anisotropy for the visible channels. The uniformity filters and PDF bin size have minimal impacts on the visible channels and a larger impact on the SWIR bands. The newly optimized DCCT will be used for future evaluation of MODIS on-orbit calibration by MODIS Characterization Support Team.

Mu, Qiaozhen

Evaluation of Aqua MODIS Thermal Emissive Bands Stability through Radiative Transfer Modeling

Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been inoperation providing continuous global observations for science research and applications since2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitoredthrough inter-comparisons with measurements by hyperspectral or multi-spectral infraredsensors or through vicarious monitoring over cold targets such as Dome-C and deep convectiveclouds. The radiative transfer modeling (RTM)-based simulation models are developed to per-form the long-term monitoring of the stability of Aqua MODIS TEBs. Long-term EuropeanCentre for Medium-Range Weather Forecasts global atmospheric reanalysis data are used asinputs to the RTM simulation. By confining ocean in low to middle latitudes as the area ofinterest, the long-term stabilities of Aqua MODIS TEBs are monitored through observationminus background (O-B) brightness temperature (BT) bias between MODIS measurements andsimulations from the RTM. In general, the RTM-based O-B analysis shows that the long-termstability of Aqua MODIS TEBs are maintained well. It is shown that Aqua MODIS surfacebands are all radiometrically stable with yearly BT bias drifts <0.005 K∕yearfor B20, B22,and B23 and∼0.01 K∕yearfor B31 and B32. The carbon dioxide (CO2) absorption channelsof Aqua MODIS, e.g., B33 to B36, are stable with a BT bias drift <0.005 K∕year. It is also foundthat after accounting for the long-term growth of greenhouse gasN2O, the O-B bias trends forB24 and B25 are quite stable with yearly BT bias drifts around 0.0002 and0.0055 K∕year,respectively. The stabilities of the moisture-sensitive channels B27 to B29 and the ozone channelB30 of Aqua MODIS are also evaluated and the remnant small variations in the O-B bias trend-ing of these channels are further discussed. The RTM-based inter-comparison of MODIS TEBmeasurements with global atmospheric and climate re-analysis data provides validation of thelong-term radiometric stability of Aqua MODIS TEBs. The analysis in this paper also demon-strates that the comparison of well-calibrated MODIS TEB measurements with RTM simulationhelps quantify the long-term impacts of global greenhouse gas concentration growth on the BTdecreases in the MODIS greenhouse gas-sensitive channels.

MODIS

MODIS Thermal Emissive Bands Calibration Improvements for Collection 7

The MODIS thermal emissive bands (TEB) radiometric calibration uses a quadratic function for the instrument response, and the calibration coefficients look-up tables (LUTs) are updated using the response of an on-board blackbody (BB). After more than 21 and 19 years on-orbit, the TEB performances for Terra and Aqua MODIS have been generally stable. However, contamination from electronic crosstalk, a known issue since prelaunch, has affected the L1B image quality and measurement accuracy. In addition to the photovoltaic (PV) longwave infrared (LWIR) bands crosstalk correction included in Terra MODIS Collection 6.1 (C6.1), a crosstalk correction for select detectors in the Terra and Aqua mid-wave infrared (MWIR) and Aqua PV LWIR bands are applied in C7. The mission-long crosstalk coefficients for the selected detectors are derived and populated in the form of LUTs. The crosstalk correction is applied to both on-orbit calibration and the algorithm used to generate Earth-view L1B products. Among these detectors, the Aqua MODIS band 24 detector 1 crosstalk has the largest impact on image quality, with striping observed over cold scenes for both Terra and Aqua MODIS. The images of C7 L1B and C6.1 are compared to assess the impact of the correction. Additional assessments using Earthview measurements and inter-comparison also revealed the need for improvement of calibration stability and consistence for select bands. Additional improvements for long-term stability and mirror side consistence were developed using quasideep convective clouds (qDCC), Dome-C, ocean, desert, and inter-comparison with other instruments.

MODIS

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra and Aqua CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS imagers to determine cloud properties that are used in the angular distribution model scene selection required to convert the CERES observed radiances into flux values. Once the Terra and Aqua orbits start drifting outside of their 15-minute window, the CERES project will rely solely on the NOAA-20 CERES observations. A seamless transition of fluxes and clouds can only occur if the analogous MODIS and VIIRS channels are properly inter-calibrated. The visible band (0.65 µm) in MODIS (band 1) and VIIRS (M5 or I1) is critical for retrieving the cloud mask and optical depth. The spectral response functions (SRF) of these bands differ noticeably and will require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Fortunately, the VIIRS I1 and M5 bands are calibrated using the same solar diffuser as a reference, which implies that band reflectance differences must be due to the spectral disparity. The coincident I1 and M5 TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, Hyperion, and radiative transfer model-based scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study will evaluate the SCIAMACHY, GOME-2, Hyperion, and RTM based SBAFs over tropical ocean targets used in SNO inter-calibration of MODIS and VIIRS, including clear-sky ocean, deep convective clouds (DCC), and liquid cloud targets in terms of their applicability to absolute intercomparison of visible imagers. The large SCIAMACHY and GOME-2 footprints and the lack of Hyperion cloudy scenes will impact the resulting SBAFs and necessitates the need for future CLARREO hyper-spectral reflectances to decrease SBAF uncertainties Preliminary results indicate that the SCIAMACHY and GOME-2 based SBAFs for the VIIRS I1 and M5 band pairs may differ by 1.5% for some ATO scene types. Because most of the modern GEOs visible band SRFs encompass the VIIRS I1 band SRF, these evaluations are critical to ensure that the MODIS, VIIRS, and GEO clouds and fluxes are consistent. SBAFs for Libya-4, Dome-C and other Earth invariant target will also be evaluated.

D. R. Doelling

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The NASA CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra, Aqua, and NOAA20 CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS or VIIRS imagers to determine cloud properties used for angular distribution model scene selection, which is required to convert the CERES observed radiances into flux values. Furthermore, CERES utilizes geostationary imager (GEO) hourly fluxes and clouds to infer the regional averaged daily flux in the SYN1deg product. A seamless transition of fluxes and clouds can only occur if the analogous MODIS, VIIRS, and GEO channels are properly inter-calibrated. The analogous band SRFs differ noticeably and require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Given their disparate but overlapping SRFs, the coincident VIIRS I1 and M5 band TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, and Hyperion scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study highlights the SCIAMACHY, GOME-2, and Hyperion based SBAFs for different MODIS, VIIRS, and GEO inter-calibration targets, including all-sky tropical ocean (ATO), Libya-4, Dome-C, and deep convective clouds. To mitigate the observed sensor radiance fluctuations due to atmospheric absorption and aerosol variations, the Earth target observed radiances are correlated with multiple atmospheric parameters, such as precipitable water and ozone. The remaining M5 and I1 mean spectral band radiance difference should be resolved by the SBAF correction. The formulation of hyper-spectral sensor based SBAFs and validation methods can be verified in future utilizing high-accuracy, SI-traceable hyper-spectral measurements from CLARREO Pathfinder.

David R Doelling

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS