Demonstration and Validation of a Virtual Energy Audit Tool for DoD Buildings

Electricity consumption has been in the spotlight as part of the battle for sustainability resulting in legislative measures to try and reduce the amount of energy used. EISA 432 and the Energy Act of 2020 are two examples that require federal facilities to investigate buildings and find saving opportunities through energy audits. EDIFES solves this problem by providing fully virtual audits. Only five inputs are needed (15-minute interval electricity consumption, location, square footage, number of stories, and building end use) to produce complete energy audits. The virtual audit is automated, making them inexpensive and the small number of inputs allows a large number of buildings to be entered quickly. During this project, EDIFES performed energy audits on hundreds of buildings to ensure proper functionality and workflow. Over 250 DoD buildings received energy audits that then had their results posted to an interactive dashboard with portfolio rankings. Several validation methods were employed. All confirmed that EDIFES's methods worked as expected and with a high degree of accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Voltage, Intermediate-Temperature, Fe- and Al-Mixed Metal Halide Molten Salt for Molten Sodium Battery Energy Storage

An inorganic Fe and Al halide-based, low-temperature molten salt catholyte is described, which, when paired with a molten sodium anode, has high operating potentials rivaling those of Li ion batteries. The newly developed catholyte consists of metal halides FeCl 3 /FeCl 2 –AlCl 3 –NaCl and is intended to cycle between Fe 3+ /Fe 2+ redox couples in the molten salt. The multicomponent molten salt was initially evaluated for phase behavior and basic electrochemical behavior before full battery testing. The assembled battery, utilizing a 20:35:45 (FeCl 3 :AlCl 3 :NaCl) composition, with a 50.83 Ah/kg theoretical gravimetric capacity and a specific energy of 176.95 Wh/kg, was cycled at variable depths of discharge (DoD) and current densities to determine its cycling efficiencies and limitations. In conclusion, preliminary cycling tests showed two operational potential regimes, with higher potential, 3.91 V (vs Na/Na + ), at low DoD and lower potential, 3.39 V (vs Na/Na + ), at high DoD with excellent energy efficiencies and cycling behavior under both regimes.

Aluminum↗

Fallout Cloud Regimes

The U.S. Department of Defense (DOD), Department of Energy (DOE), and other organizations maintain operational nuclear explosion and atmospheric dispersion models to provide critical guidance on the expected effects of an accidental or deliberate explosion of a nuclear weapon (in this paper simply referred to as “device”). To be effective, these models must represent, as accurately as possible, the complex interactions of the blast, fire, and residual radiological hazards with the environment and population. One hundred atmospheric nuclear tests that form the basis for many models were conducted at the Nevada Test Site (NTS) (now referred to as the Nevada Nuclear Security Site, NNSS) in a dry desert environment. Other environments should be studied, but have less data available and are beyond the scope of the work presented in this paper. The debris clouds produced by the NTS tests, frequently called “mushroom clouds,” are familiar, with common structural elements such as a buoyant cap connected to a skirt of raised dust at the desert surface by a thin, dirt-filled stem. The film scanning project at LLNL has investigated historical film records of nuclear weapons tests. Here, we summarize findings showing that the mushroom cloud behavior for historic U.S. tests conducted in Nevada, has similar characteristics based on the distance of the device from the ground surface or Height of Burst (HOB), scaled by the energy release, or yield, of the device. This scaled height is referred to as the scaled-height-of-burst (SHOB). The findings discussed below show that mushroom clouds look and behave similarly when detonated at the same SHOB. The amount of residual radiation that is produced by a nuclear detonation is proportional to the yield. But, the amount of that residual radiation that actually becomes local fallout is strongly dependent on the SHOB and the type of surface over which the detonation occurs. In order to develop a more comprehensive model that predicts the fraction of the residual radiation that becomes local fallout, it is convenient to define a series of regimes based on SHOB values in which all detonations that occur within a given regime can be modeled using the same algorithms. The purpose of this paper is to provide a framework for defining different regimes, and, in a qualitative way, a basic understanding of the fundamental characteristics of each of these regimes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Microgrids for Energy Resilience: A Guide to Conceptual Design and Lessons from Defense Projects

The U.S. Department of Defense (DoD) has long recognized the strategic value of energy to its missions, and the energy resilience of DoD installations has become of increasing concern. Department of Defense Instruction 4170 requires installations to be more energy resilient, and as a result, many installations are pursuing microgrids to meet their energy resiliency goals and requirements. This report provides a resource for stakeholders involved in analyzing and developing microgrid projects at DoD installations. It builds on experience and lessons from the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) in supporting numerous DoD projects, including the microgrid at Marine Corps Air Station Miramar.(1)The report is structured following NREL's microgrid design process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation

Advanced district thermal energy systems, also known as thermal microgrids, can meet the energy needs of urban districts in a highly efficient way, but adoption of such systems, especially in the United States, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degrees F; 15-25 degrees C) temperatures, and water-source heat pumps at connected buildings are used to boost or lower the temperature for space conditioning and service hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to accelerating their adoption. This paper aims to contribute to that by reporting preliminary results from a feasibility study of a thermal microgrid at a U.S. Department of Defense installation and illustrating the process of conceptual design to seek the best possible performance within the many constraints of existing buildings. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for resilience and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategies for Enhancing Battery Life Under Fast Charging: Insights from NMC-Based Cell Cycling

Fast charging improves the usability of consumer electronics and electric vehicles (EVs) by reducing range anxiety and downtime but accelerates battery degradation and raises safety concerns. Optimizing operational conditions during fast-charging is critical to mitigating aging and ensuring safety. This study evaluated multilayer Gr/NMC811 cells under various conditions, including depths of discharge (DODs of 68%, 84%, and 100%), upper charge cutoff voltages (4.1–4.2 V), and post-charge rest periods (2–30 min), using a 20 min fast charging protocol for up to 500 cycles (up to 150,000 miles of EV use assuming 3.3 mi/kWh vehicle level energy efficiency). Surprisingly, higher DODs under fast charging improved battery life and performance compared to lower DODs. Reducing the upper charge cut-off voltage helped mitigate degradation. A brief 2 min rest period after charging further reduced aging effects. The primary aging modes were loss of lithium inventory and cathode active material. Although minor lithium plating was observed within 500 cycles, it did not affect performance significantly. These findings suggest that, with optimized conditions, cells can sustain hundreds of fast charge cycles—equivalent to over 100,000 miles of EV use—without significant adverse effects on performance or longevity.

25 - ENERGY STORAGE↗

High Depth‐of‐Discharge Zinc Rechargeability Enabled by a Self‐Assembled Polymeric Coating

Abstract Zinc has the potential for widespread use as an environmentally friendly and cost‐effective anode material pending the resolution of rechargeability issues caused by active material loss and shape change. Here, a self‐assembled Nafion‐coated Celgard 3501 (NC‐Celgard) separator is shown to enable unprecedented cycle life of a Zn anode in alkaline electrolyte at high depth‐of‐discharge (DOD Zn ). Using commercially relevant energy‐dense electrodes with high areal capacities of 60 mAh cm –2 , Zn–Ni cells tested at 20% DOD Zn cells achieve over 200 cycles while 50% DOD Zn cells achieve over 100 cycles before failure. The 20% and 50% DOD cells deliver an average of 132 and 180 Wh L –1 per cycle over their lifetime respectively. Rechargeability is attributed to the highly selective diffusion properties of the 300 nm thick negatively charged Nafion coating on the separator which prevents shorting by dendrites and inhibits redistribution of the active material. Crossover experiments show that the NC‐Celgard separator is practically impermeable to zincate ([Zn(OH) 4 ] 2– ), outperforming commercial Celgard, cellophane, Nafion 211 and 212 separators while still allowing hydroxide transport. This work demonstrates the efficacy of selective separators for increasing the cycle life of energy‐dense Zn electrodes without adding significant volume or complexity to the system.

Arnot, David J.↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗

Defense Resilience Technical Assistance Options - Initial Overview

The Defense Resilience Technical Assistance (TA) project, a collaboration between the DOE Grid Deployment Office and the DoD, aims to enhance energy infrastructure at military installations and utilities and the surrounding community. It focuses on improving energy system performance, addressing power infrastructure inadequacies, enhancing power quality, reducing cyber sabotage impacts, and strengthening digital supply chains. Defense Resilience Technical Assistance Options - Initial Overview. Intend to tailor to the pilot installation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Cultural Resource Survey of 110.55 Acres at the Coyote Test Field, Sandia National Laboratories, Kirtland Air Force Base, Bernalillo County, Albuquerque, New Mexico

This report presents the results of a Section 110 cultural resource survey of Sandia National Laboratories’ (Sandia) 9930 and 9939 Complexes, in the Coyote Test Field (CTF), located on lands permitted to the Department of Energy (DOE) by the Department of Defense (DOD), Kirtland Air Force Base (KAFB), Bernalillo County, Albuquerque, New Mexico. The Department of Energy, National Nuclear Security Administration Sandia Field Office (DOE/NNSA SFO) and National Technology and Engineering Solutions of Sandia, LLC, in accordance with Section 110 and Section 106 of the National Historic Preservation Act (NHPA) and its implementing regulations 36 C.F.R. Part 800, states that every federal agency must establish their own historic preservation program for the identification, evaluation, and protection of historic properties and to ensure that historic preservation is fully integrated into the ongoing programs of federal agencies. Sandia’s Cultural Resources Program (CRP) establishes areas of potential effects based upon projected Sandia mission needs. Some of these areas have no immediate undertakings planned but are in areas where undertakings can happen at a future date.

54 ENVIRONMENTAL SCIENCES↗

Closure Report for the Project Shoal Area: Subsurface Corrective Action Unit 447 Shoal,Nevada, Site

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) has prepared this Closure Report for subsurface Corrective Action Unit (CAU) 447 at the Shoal, Nevada, Site, which was formerly called the Project Shoal Area. The Shoal site was the location of an underground nuclear test in 1963 that resulted in residual radionuclide contamination at the detonation depth of 1211 feet (ft) (DOE 2015a). The environmental restoration process and Corrective Action strategy are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO) (FFACO 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) statues and regulations. Responsibility for the environmental site restoration was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The Shoal site is south of U.S. Highway 50, approximately 30 miles southeast of Fallon, in Churchill County, Nevada (Figure 1). The site was selected for underground nuclear testing in 1961, as part of the Vela Uniform Program. Vela was a research and development program directed toward locating, detecting, and identifying underground and high-altitude nuclear detonations. The Vela Uniform program was specific to underground detonations (AEC 1964). The objective of Project Shoal was to detonate a nuclear device underground in an active seismic area to improve the United States’ ability to detect, identify, and locate underground nuclear detonations. The underground nuclear test at Shoal was a joint effort between the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC), which was the predecessor agency to DOE. Figure 1 is a map showing the site location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emergency Diesel Generator Reliability and Installation Energy Security

The U.S. Department of Defense’s (DoD’s) fixed installations - or military bases - are a critical element of national security. Military bases support the maintenance and deployment of weapons systems, training and mobilization of combat forces, and provide direct support to combat operations. Fixed installations do not operate without energy and they rely largely on electricity to support critical missions and functions. Installations are dependent on a commercial grid that is vulnerable to disruption due to severe weather, physical attacks, and cyberattacks. This report looks at the impact on the highest priority critical loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Camp Lejeune Federal Fleet Tiger Team EVSE Site Assessment

The National Renewable Energy Laboratory (NREL) was contracted by the Department of Defense (DOD) Environmental Security Technology Certification Program (ESTCP) and the Department of Energy (DOE) Federal Energy Management Program (FEMP) to develop a web tool and complete pilot assessments for the installation of Electric Vehicle Supply Equipment (EVSE). NREL has deployed Tiger Teams comprising engineers and fleet experts to support DOD and DOE on several EVSE site assessments since 2015. However, the advancements developed in support of this report, including a cost-estimation tool and geospatial mapping tool, will enable a user-driven path to assess EVSE needs. This report details the site design recommendations for Camp Lejeune, North Carolina.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Deciphering the Evolution of Current Distribution in Hybrid Silver Vanadium Oxide / Carbon Monofluoride Cathodes within Lithium Primary Batteries

For batteries to function effectively all active material must be accessible requiring both electron and ion transport to each particle. A common approach to generating the needed conductive network is the addition of carbon to create a composite electrode. An alternative approach is the electrochemically induced formation of conductive reaction products where the electrochemically generated materials are in intimate contact with the active material contributing to effective connection of each active particle. Furthermore, this study probes silver vanadium oxide (Ag 2 V 4 O 11 , SVO), carbon monofluoride (CF x ), and hybrid SVO/CF x electrodes in lithium batteries. Ex situ XRD identifies Ag 0 as a reduction product from SVO and LiF from CF x that can be followed as a function of depth-of-discharge (DOD). Spatially-resolved operando energy dispersive x-ray diffraction reveals that the presence of SVO alleviates reaction heterogeneity in the electrodes which are electron transfer limited in the absence of sufficient Ag 0 . Synchrotron X-ray tomography on discharged cathodes reveals the distribution of silver particles where the particles are more closely spaced near the current collector indicating multiple nucleation sites for their formation. Finally, operando isothermal microcalorimetry is used to determine the heat dissipation of the parent and hybrid battery types. Using material enthalpy potentials, we determine the current distribution between the two active materials for the discharging hybrid cathode adding further insight to the diffraction analysis. Taken together, these results provide a comprehensive understanding of hybrid SVO/CF x cathodes and give guidance on optimal compositions that balance power and energy density considerations.

36 MATERIALS SCIENCE↗

Energy Resilience for Mission Assurance: Case Study Scoping Document

The Energy Resilience for Mission Assurance (ERMA) project—a Department of Energy Grid Modernization Lab Consortium effort carried out via a partnership among five national laboratories— seeks to develop metrics to quantify how improvements to energy system resilience translate to improved Department of Defense (DoD) mission assurance (MA) during wide-scale, long-duration outages of the bulk power system. DoD missions are integral to national security and highly dependent on electric power. However, energy system planners—both civilian and military—lack a clear and quantifiable mapping between electric power system resilience and MA, leaving a gap in their ability to understand and consider national security outcomes within their planning efforts. The ERMA project seeks to fill this gap, providing stakeholders with new capabilities to understand the impact of electric power system resilience on MA during hazard scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗