Magnetic display devices
Magnetic display devices covering magneto-optical displays, magnetic-electrostatic technique combinations and ferromagnetography
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Magnetic display devices covering magneto-optical displays, magnetic-electrostatic technique combinations and ferromagnetography
CRT display devices and R and D, discussing electron generation, luminescent materials, resolution, brightness, etc
Behavior displayed by europium doped AZrO{sub 3} phosphor which was synthesized by solid state reaction method. For synthesis of BaZrO{sub 3}, SrZrO{sub 3} and CaZrO{sub 3} phosphor with fixed concentration of europium ion was calcination at 1000°C and sintered at 1300°C following intermediate grinding. Synthesized sample was characterized by X-ray diffraction analysis and crystallite sized was calculated by Scherer’s formula. From PL spectra of prepared phosphors shows intense emission centred at 612nm (red emission) with high intensity for SrZrO{sub 3}:Eu{sup 3+}. For europium doped BaZrO{sub 3} and CaZrO{sub 3} (613nm) phosphor shows less intense PL spectra as compared to SrZrO{sub 3}:Eu{sup 3+}. The strong emission peak of AZrO{sub 3}:Eu{sup 3+} phosphor is due to forced electric dipole transition of {sup 5}D{sub 0} to {sup 7}F{sub 2} centered at 612 and 613nm. It is characteristic red emission for europium ion. The excitation spectra of AZrO{sub 3}:Eu{sup 3+} phosphor mainly consists of the charge transfer and (CTB) of Eu{sup 3+} located in 200–350 nm centred at 254nm. The present phosphors can act as single host for red light emission in display devices. The CIE coordinates were calculated by Spectrophotometric method using the spectral energy distribution of the AZrO{sub 3}:Eu{sup 3+} sample.
Many different types of stereoscopic display devices are used for commercial and research applications. Stereoscopic displays offer the potential to improve performance in detection tasks for medical imaging diagnostic systems. Due to the variety of stereoscopic display technologies, it remains unclear how these compare with each other for detection and estimation tasks. Different stereo device shave different performance trade-offs due to their display characteristics. Among them, crosstalk is known to affect observer perception of 3D content and might affect detection performance. We measured and report the detailed luminance output and crosstalk characteristics for three different types of stereoscopic display devices. We recorded the effect of other issues on recorded luminance profiles such as viewing angle, use of different eye wear, and screen location. Our results show that the crosstalk signature for viewing 3D content can vary considerably when using different types of 3D glasses for active stereo dis-plays. We also show that significant differences are present in crosstalk signatures when varying the viewing angle from 0 degrees to 20 degrees for a stereo mirror 3D display device. Our detailed characterization can help emulate the effect of crosstalk in conducting computational observer image quality assessment evaluations that minimize costly and time-consuming human reader studies.
Fluidic decoder and display device has low-power requirements for temperature control of thermochromic materials. An electro-to-fluid converter translates incoming electrical signals into pneumatics signal of sufficient power to operate the fluidic logic elements.
An illuminated display device with a base member with a plurality of cavities therein. Illumination devices illuminate the cavities and emit light through an opening of the cavities in a pattern, and a speaker can emit sounds in synchronization with the pattern. A panel with translucent portions can overly the base member and the cavities. An animated talking character can have an animated mouth cavity complex with multiple predetermined mouth lighting configurations simulative of human utterances. The cavities can be open, or optical waveguide material or positive members can be disposed therein. Reflective material can enhance internal reflectance and light emission.
Thermochromic materials application in display devices
Liquid-crystal displays (LCDs) are the most frequently used display technology worldwide these days. Due to the rather complex manufacturing process and purity requirements for the chemicals used, quality control and display failure analysis are important analytical tasks. Currently, the state-of-the-art techniques (e.g., high-performance liquid chromatography (HPLC), gas chromatography (GC) coupled to mass spectrometry (MS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), or high-resolution microscopy) are costly and time-consuming. Hence, a new pathway to precisely analyze liquid-crystalline materials and LCDs in their native state is reported. A new approach for direct analysis via plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) offers an inexpensive and faster alternative. In this study, direct analysis in real time (DART), the low-temperature plasma (LTP) probe, and flowing atmospheric-pressure afterglow (FAPA) ADI sources coupled to high-resolution mass spectrometry (HR-MS) are compared based on their capabilities and performance for liquid-crystal analysis. These sources enable direct analyte desorption from a sample surface at ambient conditions and ionize the vaporized analyte molecules in a subsequent step. Primarily, the ionization capabilities of the three ADI sources are compared for individual liquid-crystal standards, mixtures of liquid crystals (LCs), and complex liquid crystal/additive mixtures applied in commercially available LCDs. Furthermore, direct surface analysis from a glass substrate is also performed with ADI-MS to compare their applicability to this type of sample matrix. .
A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.
Research and development in cathode ray tube display devices and components
Graphical abstract: Concentration dependence of UC emission intensity for (a) Pr{sup 3+} ions and (b) Yb{sup 3+} ions in doped/codoped Y{sub 2}O{sub 3} phosphors. - Highlights: • Upconversion emission bands with their enhanced emission intensity have been observed on codoping of Yb{sup 3+} ions. • By using Scherrer’s formula and Hall–Williamson plot, the presence of nano-structured crystallites have been identified. • The decay curve analysis for the emitting level has been performed. • The codoped phosphor proves its suitability in making the visible upconverter and display devices. - Abstract: Efficient green colour emitting Pr{sup 3+}–Yb{sup 3+} codoped Y{sub 2}O{sub 3} phosphor prepared by low temperature solution combustion process has been investigated under the excitation with a 980 nm diode laser. Several upconversion emission bands from Pr{sup 3+} ions with their enhanced upconversion emission intensity have been observed on codoping of Yb{sup 3+} ions in the Y{sub 2}O{sub 3}:Pr{sup 3+} system. To identify the phase formation, size of crystallites and strain present in synthesized sample, X-ray diffraction pattern has been recorded. The decay curve analysis for the emitting level has also been performed along with power dependence study to clear the upconversion process. The tunability of colour emitted from the codoped phosphor has been examined which proves its suitability for display devices.
Feasibility and advantages of spacecraft fluidic decoder and display device
A transformation method has been developed that is very successful in simulating composite imagery and shows that, in general, 8-bit simulated composite images are almost indistinguishable from true composite imagery. This technique was designed to facilitate the display and interpretation of composite satellite imagery on display devices with only 256 displayable colors. The method is suitable for the combination of two 8-bit images into a single 8-bit composite image.
Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2x10 -5 mm 2 at 1 mm -1 , while handheld displays have values lower than 3.7x10 -6 mm 2 . Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices.
Digital and analog large system data displays, considering CRT, laser, hybrid types, contrast control, etc
Explore the source record for details and available documents.