At least 19 records

The high intensity diffractometer for residual stress analysis (HIDRA), a third generation residual stress mapping neutron diffractometer at the high flux isotope reactor

This paper describes the hardware and software upgrades, operation, and performance of the high intensity diffractometer for residual stress analysis (HIDRA) instrument, a residual stress mapping neutron diffractometer located at the High Flux Isotope Reactor at Oak Ridge National Laboratory in Oak Ridge Tennessee, USA. Following a major upgrade in 2018, the new instrument has a single 3 He multiwire 2D 30 × 30 cm 2 position sensitive detector, yielding a field of view of 17° 2θ. Further, the increase in the field of view (from 4° 2θ) from the previous model instrument has contributed to the tremendous improvement in the out of plane solid angle such that the 3D count rate could be obtained easily. Accordingly, the hardware, software, Data Acquisition System (DAS), and so on have also been updated. Finally, all these enhanced features of HIDRA have been ably demonstrated by conducting multi directional diffraction measurements in the quenched 750-T74 aluminum, and the evolved and improved strain/stress mappings are presented.

3D printing↗

Quantitative texture analysis at the WAND 2 and HIDRA diffractometers

Data collection and analysis strategies have been developed for efficient and reliable crystallographic texture measurements at two recently upgraded neutron diffractometers: the Wide Angle Neutron Diffractometer Squared (WAND 2 ) and the High Intensity Diffractometer for Residual Stress Analysis (HIDRA) at the High Flux Isotope Reactor located at Oak Ridge National Laboratory. These methods are demonstrated using measurements on a variety of textured samples, including multi-phase steel composites and polycrystalline calcite (CaCO 3 ). Reference measurements were also made at VULCAN, the engineering diffractometer located at the Spallation Neutron Source. The texture data obtained on the different instruments are in agreement, and WAND 2 is more time efficient than HIDRA. Two analysis methods were investigated, single-peak fitting to obtain individual pole figures for inversion and Rietveld texture analysis using MAUD. Here, the impact of the differences between the various textures obtained was evaluated through the calculation of diffraction elastic constants, which is one application of the texture data collected. Both instruments were found to provide texture data that are suitable for complementing other analyses, such as residual stress mapping.

47 OTHER INSTRUMENTATION↗

Effect of Collimation on Diffraction Signal-to-Background Ratios at a Neutron Diffractometer

High diffraction signal-to-background ratios (SBRs), the ratios of diffraction peak integrated intensity over its background intensity, are desired for a neutron diffractometer to acquire good statistics for diffraction pattern measurements and subsequent data analysis. For a given detector, while the diffraction peak signals primarily depend on the characteristics of neutron beam and sample coherent scattering, the background largely originates from the sample incoherent scattering and the scattering from the instrument space. In this work, we investigated the effect of collimation on neutron diffraction SBRs of Si powder measurements using one high-angle area detector bank coupled with six different collimation configurations in a large and complex instrument space at the engineering materials diffractometer VULCAN, SNS, ORNL. The results revealed that the diffraction SBRs can be significantly improved by a proper coarse collimator that leaves no gap between the detector and the collimator, and the improvement of SBRs by a fine radial collimator was remarkable with a proper coarse collimator in place but not distinguishable without one. It was also found that the diffraction SBRs were not effectively improved by adding neutron absorbing element boron to the fine radial collimator body, which indicates that either the absorption of secondary scattered neutrons by the added boron is insignificant or the collimator base material (resin and ABS) alone attenuates background scattering sufficiently. These findings could serve as a useful reference for diffractometer developers and/or operators to optimize their collimation to achieve higher diffraction SBRs.

Yu, Dunji↗

EWALD: A macromolecular diffractometer for the second target station

Revealing the positions of all the atoms in large macromolecules is powerful but only possible with neutron macromolecular crystallography (NMC). Neutrons provide a sensitive and gentle probe for the direct detection of protonation states at near-physiological temperatures and clean of artifacts caused by x rays or electrons. Currently, NMC use is restricted by the requirement for large crystal volumes even at state-of-the-art instruments such as the macromolecular neutron diffractometer at the Spallation Neutron Source. EWALD’s design will break the crystal volume barrier and, thus, open the door for new types of experiments, the study of grand challenge systems, and the more routine use of NMC in biology. EWALD is a single crystal diffractometer capable of collecting data from macromolecular crystals on orders of magnitude smaller than what is currently feasible. The construction of EWALD at the Second Target Station will cause a revolution in NMC by enabling key discoveries in the biological, biomedical, and bioenergy sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VERDI: VERsatile DIffractometer with wide-angle polarization analysis for magnetic structure studies in powders and single crystals

The VERsatile DIffractometer will set a new standard for a world-class magnetic diffractometer with versatility for both powder and single crystal samples and capability for wide-angle polarization analysis. The instrument will utilize a large single-frame bandwidth and will offer high-resolution at low momentum transfers and excellent signal-to-noise ratio. A horizontal elliptical mirror concept with interchangeable guide pieces will provide high flexibility in beam divergence to allow for a high-resolution powder mode, a high-intensity single crystal mode, and a polarized beam option. A major science focus will be quantum materials that exhibit emergent properties arising from collective effects in condensed matter. The unique use of polarized neutrons to isolate the magnetic signature will provide optimal experimental input to state-of-the-art modeling approaches to access detailed insight into local magnetic ordering.

36 MATERIALS SCIENCE↗

A compact in situ polarized 3He neutron spin filter for the diffractometer VULCAN at the Spallation Neutron Source

We have built and commissioned a compact in situ 3He polarizer based on spin-exchange optical pumping for the engineering materials diffractometer, named VULCAN, at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The system achieved 78% 3He polarization with a short pump-up time constant of 2.2 h. Its first deployment in an in situ half-polarized neutron diffraction experiment on a magnetic shape memory alloy, Ni–Mn–Ga, revealed changes in magnetization coupled to deformation twinning under compression. With this new capability, VULCAN has become the first diffractometer at SNS capable of performing polarized neutron experiments, opening new opportunities to study a wider range of magnetism-related material behaviors under varied thermal, mechanical, electrical, and/or magnetic fields.

Fu, Sichao [ORNL] (ORCID:0009000846771640)↗

Design and Optimization of the IMAGINE-X Diffractometer at NB1

An upgraded protein crystal diffractometer with Dynamic Nuclear Polarization (DNP) is proposed for installation during the next HFIR Beryllium Reflector Replacement. The diffractometer will replace the IMAGINE protein crystal diffraction instrument currently located at CG4D. The simulation design meets the needs as requested in the science requirements document.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Magnetic pair distribution function and half polarized neutron powder diffraction at the HB-2A powder diffractometer

Local magnetic order and anisotropy are often central for understanding fundamental behavior and emergent functional properties in quantum materials and beyond. Advances in neutron powder diffraction experiments and analysis tools now allow for quantitative determination. Here, we demonstrate this here with complementary total neutron scattering and polarized neutron measurements on the HB-2A neutron powder diffractometer at the High Flux Isotope Reactor (HFIR). In recent years, magnetic pair distribution function (mPDF) analysis has emerged as a powerful technique for probing local magnetic spin ordering of magnetic materials. This method can be broadly applied to any magnetic material but is particularly effective for studying systems with short-range magnetic order, such as materials with reduced dimensionality, geometrically frustrated magnets, thermoelectrics, multiferroics, and correlated paramagnets. Magnetic anisotropy often underpins the short-range order adopted. Half-polarized neutron powder diffraction (pNPD) can be used to determine the local susceptibility tensor on the magnetic sites to quantify the magnetic anisotropy. Combining the techniques of mPDF and pNPD can therefore provide valuable insights into local magnetic behavior. A series of measurements optimized for these techniques are presented as exemplar cases focused on frustrated materials where short-range order dominates, these include measurements to ultra-low temperature (<100 mK) not typically accessible for such experiments.

Half polarized neutron scattering↗

Investigating Quantum Materials with Half-Polarized Diffraction and magnetic PDF analysis at the HB-2A Neutron Powder Diffractometer

Local magnetic ordering and anisotropy is often central to the emergent behavior and subsequent functional properties in quantum materials and beyond. Neutron powder diffraction provides a straightforward yet extremely powerful technique for quantitative measurements of microscopic magnetic properties. The HB-2A powder diffractometer located at the High Flux Isotope Reactor in ORNL is traditionally utilized for long-range magnetic structure determination. Recently these capabilities have been extended to include methods aimed at accessing local magnetism: Half- polarized neutron powder diffraction (pNPD) and magnetic pair distribution function (mPDF) analysis. These two distinct techniques are possible on HB-2A due to the versatility of the instrument’s reciprocal space coverage, resolution and novel ultra-low temperature multi-sample changers that operate down to dilution refrigerator temperatures. This provides unique capabilities not found on any powder diffraction instrument and is particularly well suited to investigations of magnetic quantum materials. The development and implementation of these techniques will be discussed with a series of science case examples ranging from geometric frustrated magnets to magnetic metal-organic frameworks. Data reduction and analysis tools will be presented that enable the extraction of the local site susceptibility tensor and local spin-spin correlations in real space. Finally, potential combinations of these techniques in the form of half-polarized magnetic pair distribution function (pmPDF) analysis will be considered. Looking forward, HB-2A is undergoing a detector upgrade that will be in the user program by 2026. This will offer an order of magnitude increase in count rates to further aid the development of these often low signal measurements and provide new scientific capabilities.

Neutron Scattering↗

Optical design for the single crystal neutron diffractometer Pioneer

Pioneer is a single-crystal neutron diffractometer optimized for small-volume samples and weak signals at the Second Target Station at Oak Ridge National Laboratory. This paper presents the preliminary optical design progress, focusing on the rationale behind key design choices. It covers the T 0 and bandwidth disk choppers, guide and beam control system, incident-beam polarizer, scattering beam collimators, and additional strategies. The chopper locations are selected to maximize neutron transport while taking advantage of standardized shielding structures. To accommodate the maintenance shield, operational shutter, and polarizing V-cavity, the guide design includes significant gaps. When these optical components are moved out of the beam path, oversized collimators, rather than guides, will be translated in. Pioneer will utilize slit packages to control beam size and divergence and a translatable polarizing V-cavity. Absorbing panels are strategically placed near the end station to minimize background. An oscillating radial collimator, operating in a shift mode, will be used with the vertical cylindrical detector, while a fixed multi-cone collimator will be used with the bottom flat detector. In conclusion, these collimators will enable the detection of weak signals when complex sample environments are used.

47 OTHER INSTRUMENTATION↗

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Detector pixel calibration of time-of-flight neutron diffractometers accelerated by machine learning

Modern time-of-flight neutron diffractometers at spallation neutron source are equipped with two dimensional detectors with fine pixelations. The flight path of neutrons from the moderator to the sample and to the detector needs to be precisely calibrated at detector pixel level using standard powders so the diffraction data from all the detector pixels can be correctly time-focused to produce high resolution diffraction peaks. The number of pixels can reach to millions which makes a single-pixel calibration process time-consuming, or even impossible, with conventional fitting routine. Here we presented a machine learning aided calibration process via a “training and predict” process by training machine learning models with the relations between the individual pixel time-of-flight diffraction pattern and fitted diffraction constant. The training models take a portion of the available pixels to predict the diffraction constants precisely and rapidly for massive pixel diffraction patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗